排序方式: 共有59条查询结果,搜索用时 31 毫秒
1.
2.
3.
4.
5.
6.
7.
A microfluidic biosensor with electrochemical detection for the quantification of nucleic acid sequences was developed. In contrast to most microbiosensors that are based on fluorescence for signal generation, it takes advantage of the simplicity and high sensitivity provided by an amperometric and coulorimetric detection system. An interdigitated ultramicroelectrode array (IDUA) was fabricated in a glass chip and integrated directly with microchannels made of poly(dimethylsiloxane) (PDMS). The assembly was packaged into a Plexiglas housing providing fluid and electrical connections. IDUAs were characterized amperometrically and using cyclic voltammetry with respect to static and dynamic responses for the presence of a reversible redox couple-potassium hexacyanoferrate (ii)/hexacyanoferrate (iii) (ferri/ferrocyanide). A combined concentration of 0.5 microM of ferro/ferricyanide was determined as lower limit of detection with a dynamic range of 5 orders of magnitude. Background signals were negligible and the IDUA responded in a highly reversible manner to the injection of various volumes and various concentrations of the electrochemical marker. For the detection of nucleic acid sequences, liposomes entrapping the electrochemical marker were tagged with a DNA probe, and superparamagnetic beads were coated with a second DNA probe. A single stranded DNA target sequence hybridized with both probes. The sandwich was captured in the microfluidic channel just upstream of the IDUA via a magnet located in the outside housing. Liposomes were lysed using a detergent and the amount of released ferro/ferricyanide was quantified while passing by the IDUA. Optimal location of the magnet with respect to the IDUA was investigated, the effect of dextran sulfate on the hybridization reaction was studied and the amount of magnetic beads used in the assay was optimized. A dose response curve using varying concentrations of target DNA molecules was carried out demonstrating a limit of detection at 1 fmol assay(-1) and a dynamic range between 1 and 50 fmol. The overall assay took 6 min to complete, plus 15-20 min of pre-incubation and required only a simple potentiostat for signal recording and interpretation. 相似文献
8.
A novel protocol for the synthesis of dye-encapsulating liposomes tagged with DNA oligonucleotides at their outer surface
was developed. These liposomes were optimized for use as signal enhancement agents in lateral-flow sandwich-hybridization
assays for the detection of single-stranded RNA and DNA sequences. Liposomes were synthesized using the reverse-phase evaporation
method and tagged with oligonucleotides by adding cholesteryl-modified DNA probes to the initial lipid mixture. This resulted
in a greatly simplified protocol that provided excellent control of the probe coverage on the liposomes and cut the preparation
time from 16 hours to just 6 hours. Liposomes were prepared using probe concentrations ranging from 0.00077 to 0.152 mol%
of the total lipid, several hydrophobic and polyethylene glycol-based spacers between the cholesteryl anchor and the probe,
and liposome diameters ranging from 208 nm to 365 nm. The liposomes were characterized by dynamic light scattering, visible
spectroscopy, and fluorescence spectroscopy. Their signal enhancement functionality was compared by using them in lateral-flow
optical biosensors for the detection of single-stranded DNA sequences. In these assays, an optimal reporter probe concentration
of 0.013 mol%, liposome diameter of 315 nm, and liposome optical density of 0.4–0.6 at 532 nm were found. The spacer length
between the cholesteryl anchor and the probe showed no significant effect on the signals in the lateral-flow assays. The results
presented here provide important data for the general use of liposomes as labels in analytical assays, with specific emphasis
on nucleic acid detection via lateral flow assays. 相似文献
9.
Dye-encapsulating unilamellar DNA oligonucleotide-tagged liposomes were prepared and characterized for use as signal-enhancing
reagents in a microtiter plate sandwich-hybridization analyses of single-stranded RNA or DNA sequences. The liposomes were
synthesized using the reversed-phase evaporation method and tagged with DNA oligonucleotides by adding cholesteryl-modified
DNA reporter probes to the initial lipid mixture. Liposomes were prepared using probe coverages of 0.0013–0.103 mol% of the
total lipid input, several hydrophobic and poly(ethylene glycol)-based spacers between the cholesteryl anchor and the probe,
and liposome diameters ranging from 200 nm to 335 nm. Their signal enhancement functionality was compared by using them in
microtiter plate sandwich-hybridization assays for the detection of single-stranded DNA sequences. In these assays, an optimal
reporter probe concentration of 0.103 mol%, a liposome diameter of 274 nm, and a phospholipid concentration of 0.3 mM were
found. The length between the cholesteryl anchor and the probe was optimal when a spacer composed of TEG+(CH2O)3 was used. Under optimal conditions, a detection limit of 0.5 nM for a truncated synthetic DNA sequence was found with a coefficient
of variation of 4.4%. A 500-fold lower limit of detection using fluorescence was found using lysed dye-encapsulating liposomes
versus a single fluorescein-labeled probe. Finally, when this method was applied to the detection of atxA RNA extracted from E.coli SG12036-pIu121 and amplified using NASBA, a minimum extracted concentration of RNA of 1.1×10−7 μg/μL was found. 相似文献
10.