首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   18篇
  免费   2篇
化学   20篇
  2020年   1篇
  2018年   2篇
  2017年   1篇
  2016年   2篇
  2015年   1篇
  2014年   4篇
  2013年   5篇
  2012年   1篇
  2011年   3篇
排序方式: 共有20条查询结果,搜索用时 46 毫秒
1.
We describe a novel magnetic metal-organic framework (MOF) for the preconcentration of Cd(II) and Pb(II) ions. The MOF was prepared from the Fe3O4-pyridine conjugate and the copper(II) complex of trimesic acid. The MOF was characterized by IR spectroscopy, elemental analysis, SEM and XRD. A Box-Behnken design through response surface methodology and experimental design was used to identify the optimal parameters for preconcentration. Extraction time, amount of magnetic MOF and pH value were found to be critical factors for uptake, while type, volume, concentration of eluent, and elution time are critical in the elution step. The ions were then determined by FAAS. The limits of detection are 0.2 and 1.1 μg?L?1 for Cd(II), and Pb(II) ions, respectively, relative standard deviations are <4.5% (for five replicates at 50 μg?L?1 of Cd(II) and Pb(II) ions), and the enrichment capacity of the MOF is at around 190 mg?g?1 for both ions which is higher than the conventional Fe3O4-pyridine material. The magnetic MOF was successfully applied to the rapid extraction of trace quantities of Cd(II) and Pb(II) ions in fish, sediment, and water samples.
Figure
Schematic illustration of synthesized magnetic MOF-pyridine nanocomposite  相似文献   
2.

This work describes a novel polyaniline-magnetite nanocomposite and its application to the preconcentration of Cr(VI) anions. The material was obtained by oxidative polymerization of aniline in the presence of magnetite nanoparticles. The parameters affecting preconcentration were optimized by a Box-Behnken design through response surface methodology. Extraction time, amount of magnetic sorbent and pH value were selected as the main factors affecting sorption. The sorption capacity of the sorbent for Cr(VI) is 54 mg g−1. The type, volume and concentration of the eluents, and the elution time were selected as main factors in the optimization study of the elution step. Following sorption and elution, the Cr(VI) ions were reacted with diphenylcarbazide, and the resulting dye was quantified by HPLC with optical detection at 546 nm. The limit of detection is 0.1 μg L−1, and all the relative standard deviations are <6.3 %. The nanocomposite was successfully applied to the rapid extraction and determination of trace quantities of Cr(VI) ions in spiked water samples.

A schematic procedure of magnetic solid phase extraction

  相似文献   
3.
This work describes a novel polyaniline-magnetite nanocomposite and its application to the preconcentration of Cr(VI) anions. The material was obtained by oxidative polymerization of aniline in the presence of magnetite nanoparticles. The parameters affecting preconcentration were optimized by a Box-Behnken design through response surface methodology. Extraction time, amount of magnetic sorbent and pH value were selected as the main factors affecting sorption. The sorption capacity of the sorbent for Cr(VI) is 54 mg g?1. The type, volume and concentration of the eluents, and the elution time were selected as main factors in the optimization study of the elution step. Following sorption and elution, the Cr(VI) ions were reacted with diphenylcarbazide, and the resulting dye was quantified by HPLC with optical detection at 546 nm. The limit of detection is 0.1 μg L?1, and all the relative standard deviations are <6.3 %. The nanocomposite was successfully applied to the rapid extraction and determination of trace quantities of Cr(VI) ions in spiked water samples. Figure
A schematic procedure of magnetic solid phase extraction  相似文献   
4.
Carrier-mediated three-phase hollow fiber microextraction combined with high-performance liquid chromatography-ultra violet detection (HPLC-UV) was applied for the extraction and determination of propylthiouracil in biological samples. Propylthiouracil (PTU) was extracted from 7.5 mL of the basic solution (the source phase) with pH 12 into an organic phase (n-octanol containing 6% (w/v) of Aliquat 336 as the carrier) impregnated in the pores of a hollow fiber, and finally was back extracted into 24 μL of the acidic solution located inside the lumen of the hollow fiber (the receiving phase). The extraction was performed through the gradient of counter ion from the source to the receiving phase. The effects of different variables on the extraction efficiency were studied simultaneously using an experimental design. A half-fractional factorial design was employed for screening to determine the variables significantly affecting the extraction efficiency. Then, the factors with significant effect were optimized using a central composite design (CCD) and the response surface equations were developed. The optimal experimental conditions obtained from this statistical evaluation included: source phase, pH 12; temperature, 25 °C; extraction time, 40 min; counter ion concentration, 2 mol L−1 of NaClO4; organic solvent 6% of Aliquat in octanol and without salt addition in the source phase. Under the optimized conditions, the preconcentration factors were between 125 and 198 and also the limit of detections (LODs) ranged from 0.1 μg L−1 to 0.4 μg L−1 in different biological samples. The calibration curve was linear (r2 = 0.998) in the concentration range of 0.5-1000 μg L−1. Finally, the feasibility of the proposed method was successfully confirmed by extraction and determination of PTU in human plasma and urine as well as the bovine milk and meat samples in microgram per liter, and suitable results were obtained (RSDs < 6.3%).  相似文献   
5.
In this work, surfactant-coated Fe3O4@decanoic acid nanoparticles was synthesized as a viable nanosorbent for coextraction of drugs with different polarities (hydrophobic, hydrophilic). To reach desirable enrichment factors, efficient clean-up and low limits of detection (LODs), the method was combined with dispersive liquid–liquid microextraction (DLLME). The coupling of these extraction methods with GC-FID detection was applied to simultaneous extraction and quantification of venlafaxine (VLF) as a hydrophilic model drug and desipramine (DESI) and clomipramine (CLO) as hydrophobic model drugs in urine samples. The effect of sample pH, nanosorbent amount, sorption time, surfactant concentration, eluent type, eluent volume, salt content, elution time in magnetic solid phase extraction step and extraction solvent and its volume along with sample pH in DLLME step were optimized. Under the selected conditions, linearity was achieved within the range of 5–5000 µg L?1. The LOD values were obtained in the range of 1.5–3.0 µg L?1 for DESI, 1.2–2.5 µg L?1 for VLF and 2.0–4.0 µg L?1 for CLO, respectively. The percent of extraction recoveries and relative standard deviations (n?=?5) were in the range of 82.4–95.9 and 6.1 for DESI, 60.5–92.8 and 6.9 for VLF and 57.2–58.0 and 5.5 for CLO, respectively. Ultimately, the applicability of the new method was successfully confirmed by the extraction and quantification of DESI, VLF and CLO from human urine samples.  相似文献   
6.
In this study, diverse types of Fe3O4 nanocomposites modified by polyaniline, polypyrrole, and aniline–pyrrole copolymer were synthesized through chemical oxidative polymerization process for dispersive-μ-solid phase extraction (D-μ-SPE) in the presence of various dopants. The results showed that the nanocomposite modified by polyaniline with p-toluene sulfonic acid as a dopant demonstrated higher extraction efficiency for lorazepam (LRZ) and nitrazepam (NRZ). Also the synthesized magnetic sorbents were characterized. The nanocomposite sorbent in combination with high performance liquid chromatography–UV detection was applied for the extraction, preconcentration and determination of lorazepam and nitrazepam in urine and plasma samples. Different parameters influencing the extraction efficiency including: sample pH, amount of sorbent, sorption time, elution solvent and its volume, salt content, and elution time were optimized. The obtained optimal conditions were: sample pH, 6; amount of sorbent, 5 mg; sorption time, 5.0 min; elution solvent and its volume, 0.5 mM cethyltrimethyl ammonium bromide in acetonitrile, 150 μL; elution time, 2.0 min and without addition of NaCl. The calibration curves were linear in the concentration range of 1–2000 μg L−1. The limits of detection (LODs) were achieved in the range of 0.5–1.8 μg L−1 for NRZ and 0.2–2.0 μg L−1 for LRZ, respectively. The percent of extraction recoveries and relative standard deviations (n = 5) were in the range of 84.0–99.0, 6.1–7.8 for NRZ and 90.0–99.0, 4.1–7.0 for LRZ, respectively. Ultimately, the applicability of the method was successfully confirmed by the extraction and determination of NRZ and LRZ in human urine and plasma samples.  相似文献   
7.
Dispersive liquid-liquid microextraction based on solidification of floating organic droplet (DLLME-SFO) with simultaneous derivatization followed by high-performance liquid chromatography-diode array detection (HPLC-DAD) was applied for preconcentration and determination of primary and secondary aliphatic amines in environmental water samples. A ternary mixture consisting of a disperser, an extractant and a derivatization reagent was used for the simultaneous derivatization and extraction of aliphatic amines in different water samples. The effects of various experimental parameters on derivatization and extraction efficiency were studied simultaneously using experimental design. A Plackett-Burman design was performed for screening of variables in order to determine the significant variables affecting the extraction efficiency. Then, the significant factors were optimized by using a Box-Behnken design (BBD) and the response surface equations were derived. Under optimal conditions, the preconcentration factors were between 210 and 290. The limit of detections (LODs) ranged from 0.005 to 0.02 μg/L and dynamic linear ranges (DLRs) of 0.05-500 and 0.1-500 μg/L were obtained for most of analytes. The performance of the method was evaluated for extraction and determination of primary and secondary aliphatic amines in environmental water samples in micrograms per liter and satisfactory results were obtained (RSDs <12.5%).  相似文献   
8.
A rapid and simple quantitative method for preconcentration and determination of haloperidol in biological samples was developed using ultrasound‐assisted emulsification microextraction, based on the solidification of floating organic droplet combined with HPLC‐DAD. The effects of several factors were investigated. A total of 30 μL of 1‐undecanol as an extraction solvent was injected slowly into a glass‐centrifuge tube containing 4 mL alkaline sample solution that was located inside the ultrasonic water bath. The formed emulsion was centrifuged and the fine droplets of solvent were floated at the top of the test tube, then it was cooled in an ice bath and the solidified solvent was transferred into a conical vial, after melt, the analysis of the extract was carried out by HPLC. Under the optimal conditions, the extraction efficiencies were more than 90% and the preconcentration factors were obtained between 119–122. The LOQs were obtained between 4–8 μg/L and the calibration curves were linear within the range of 4–1000 μg/L. Finally this method was applied to the determination of haloperidol in plasma and urine samples in the range of μg/L and satisfactory results were achieved (RSDs <7%).  相似文献   
9.
In this work, a novel procedure based on surfactant‐assisted directly suspended droplet microextraction for the determination of tramadol prior to GC with flame ionization detection is proposed. In this technique, a free microdroplet of solvent is transferred to the surface of an immiscible aqueous sample containing Triton X‐100 and tramadol while being agitated by a stirring bar placed on the bottom of the sample vial. After the predetermined time, the microdroplet of solvent is withdrawn by a syringe and analyzed. The effective parameters such as the type of organic solvent, extraction time, microdroplet volume, salt content of the donor phase, stirring speed, the source phase pH, concentration of Triton X‐100, and extraction temperature were optimized. For this purpose, a multivariate strategy was applied based on an experimental design in order to screen and optimize the significant factors. This method requires minimal sample preparation, analysis time, solvent consumption, and represents significant advantages over customary analytical methods. The linearity ranged from 10 to 2000 μg/L with RSDs (n = 5) of 7.3–10. Preconcentration factors and the LODs were 391–466 and 2.5–6.5 μg/L, respectively. Finally, this method was applied to the analysis of biological samples and satisfactory results were obtained.  相似文献   
10.
Ion-pair based hollow fiber liquid phase microextraction (IP-HFLPME) coupled with high performance liquid chromatography-ultraviolet detection was applied for the preconcentration and determination of methimazole in biological samples and animal feed. Optimization of the conditions for the high extraction efficiency was studied simultaneously using the experimental design. For the first step, the Plackett-Burman design was applied to screen the significant factors on the extraction efficiency. Central composite design (CCD) was then used for the optimization of important factors and the response surface equations were obtained. The optimum experimental conditions were donor phase pH, 12.2; extraction temperature, 45°C; extraction time, 50 min; sodium perchlorate concentration, 1.5 M; cetyltrimethylammonium bromide concentration, 0.65 mM, and without salt addition in donor phase. The limit of detection and the dynamic linear range were in the range of 0.1-0.7 μg L(-1) and 0.5-1000 μg L(-1) , respectively. Preconcentration factors were obtained in the range of 93-155 in different matrices. Finally, the performance of the proposed method was tested for the determination of trace amounts of methimazole in plasma, urine, bovine milk, and animal feed samples, and satisfactory results were obtained (RSDs < 7.1%).  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号