全文获取类型
收费全文 | 462篇 |
免费 | 39篇 |
国内免费 | 2篇 |
专业分类
化学 | 354篇 |
晶体学 | 1篇 |
力学 | 21篇 |
数学 | 43篇 |
物理学 | 84篇 |
出版年
2023年 | 2篇 |
2022年 | 3篇 |
2021年 | 18篇 |
2020年 | 22篇 |
2019年 | 25篇 |
2018年 | 31篇 |
2017年 | 19篇 |
2016年 | 36篇 |
2015年 | 28篇 |
2014年 | 32篇 |
2013年 | 45篇 |
2012年 | 42篇 |
2011年 | 51篇 |
2010年 | 37篇 |
2009年 | 29篇 |
2008年 | 22篇 |
2007年 | 17篇 |
2006年 | 10篇 |
2005年 | 5篇 |
2004年 | 11篇 |
2003年 | 6篇 |
2002年 | 2篇 |
2001年 | 3篇 |
2000年 | 1篇 |
1998年 | 2篇 |
1997年 | 2篇 |
1994年 | 1篇 |
1993年 | 1篇 |
排序方式: 共有503条查询结果,搜索用时 15 毫秒
1.
Zinc polyoxometalate on activated carbon: an efficient catalyst for selective oxidation of alcohols with hydrogen peroxide 下载免费PDF全文
[PW11ZnO39]5? was immobilized on activated carbon and characterized using Fourier transform infrared, X‐ray diffraction, Brunauer–Emmett–Teller and elemental analysis techniques. Effective oxidation of various alcohols with hydrogen peroxide was performed in the presence of this catalyst. Easy separation of the catalyst from the reaction mixture, cheapness, high activity and selectivity, stability as well as retained activity in subsequent catalytic cycles make this supported catalyst suitable for small‐scale synthesis. Copyright © 2015 John Wiley & Sons, Ltd. 相似文献
2.
Valiollah Mirkhani Majid Moghadam Shahram Tangestaninejad 《Tetrahedron letters》2006,47(13):2129-2132
Rapid and efficient preparation of 2-imidazolines and bis-imidazolines by reaction of ethylenediamine with nitriles in the presence of catalytic amounts of sulfur under ultrasonic irradiation is reported. The advantages of this system are short reaction times, high yields and the ability to carry out large scale reactions. 相似文献
3.
The oxidation kinetics of ethanol with 3,4-lutindine chromium(VI) peroxide (LCP) were investigated by monitoring the absorbance change at 565 nm in dichloromethane solution. The reaction had a first-order dependence on oxidant and a fractional (one half) dependence on reactant. The stoichiometric ratio between LCP and ethanol was 1 : 2. The activation parameters were determined from temperature dependence of the reaction rate. It was found that the cleavage of the peroxide groups of LCP is primarily responsible for the oxidant of ethanol to acetaldehyde. Based on the kinetic results obtained (including deuterium isotope effect) a plausible mechanism is proposed. © 1994 John Wiley & Sons, Inc. 相似文献
4.
A supported liquid and a poly(vinyl chloride) (PVC)-based membrane selective for dodecylsulfate (DS−) ion are described. The active element is a membrane containing a dissolved ion association complex of DS− with cetylpyridinium (CP+) cation. The supported liquid membrane electrode (acetophenone as solvent) showed a Nernstian response towards the DS− anion over the concentration range of sodium dodecylsulfate (SDS) from 8.3×10−3 to 1.0×10−6 mol dm−3 at 25 °C. The proposed electrode also showed a super-Nernstian potential response (108±2 mV decade−1) at low concentrations (1.0×10−9 to 1.0×10−6 mol dm−3). Moreover, this electrode showed good selectivity and precision (R.S.D.?2.0%), and was usable within the pH range 4.0-6.8. The proposed electrode revealed a lower limit of detection of 6.3×10−7 mol dm−3 and improved selectivity in comparison with the some previously reported DS− ion selective electrodes. The isothermal temperature coefficient of this electrode amounted to −0.001 V °C−1. The liquid membrane electrode may find application in the direct determination of SDS by the standard addition method at pH 5.0, and in the physicochemical studies of surfactant solutions. 相似文献
5.
Nitrogen doped nano porous graphene as a sorbent for separation and preconcentration trace amounts of Pb,Cd and Cr by Ultrasonic assisted in‐syringe dispersive micro solid phase extraction 下载免费PDF全文
Nitrogen doped nano porous graphene was used as an efficient sorbent in solid‐phase extraction process for simultaneous separation and pre‐concentration of metal ions lead (II), cadmium(II), and chromium(III)) in biological samples. Ultrasonic assisted in‐syringe dispersive micro solid phase extraction coupled with micro sampling atomic absorption spectrometry was utilized for the determination of metal ions. Nitrogen doped nano porous graphene was synthesized as a nano sorbent by chemical vapour deposition method. Methane and aniline were used as carbon and nitrogen sources. The characterization of sorbent was performed by field emission scanning electron microscope, transmission electron microscopy, atomic force microscope, fourier transform infrared, chemical element analysis and raman analysis. Effective parameters on the extraction efficiency such as pH, sorbent dosage, eluent volume and eluent concentration were optimized by central composite design and desirability function. Experimental results indicate that the optimal conditions for this extraction were pH = 6.4, 1.42 mg of sorbent, 100 μL of eluent, and 0.84 mol L‐1 of eluent concentration. The detection limits are as low as 1.5, 0.3 and 0.9 μg L‐1 for lead, cadmium, and chromium, respectively. The intra‐day precisions were 3.6, 4.38 and 2.94 and Inter‐day precision were 4.83, 5.26 and 4.52 for lead, cadmium, and chromium, respectively. Method performance was investigated by determination of mentioned heavy metals in complicated biological matrixes such as human plasma, urine and saliva samples with good recoveries. 相似文献
6.
Behnam Vahdani S. Meysam Mousavi R. Tavakkoli-Moghaddam H. Hashemi 《Applied Mathematical Modelling》2013
The purpose of this paper is to design a new extension of the ELECTRE, known as the elimination and choice translating reality method, for multi-criteria group decision-making problems based on intuitionistic fuzzy sets. This method is widely utilized when a set of alternatives should be identified and evaluated with respect to a set of conflicting criteria by reflecting decision makers’ (DMs’) preferences. However, handling the exact data and numerical measure is difficult to be precisely focused because the DMs’ judgments are often vague in real-life decision problems and applications. A more realistic and practical approach can be to use linguistic variables expressed in intuitionistic fuzzy numbers instead of numerical data to model DMs’ judgments and to describe the inputs in the ELECTRE method. The proposed intuitionsitic fuzzy ELECTRE utilizes the truth-membership function and non-truth-membership function to indicate the degrees of satisfiability and non-satisfiability of each alternative with respect to each criterion and the relative importance of each criterion, respectively. Then, a new discordance intuitionistic index is introduced, which is extended from the concept of the fuzzy distance measure. Outranking relations are defined by pairwise comparisons and a decision graph is depicted to determine which alternative is preferable, incomparable or indifferent in the intuitionistic fuzzy environment. Finally, a comprehensive sensitivity analysis is employed to further study regarding the impact of threshold values on the final evaluation, and a comparative analysis is demonstrated with an application example in flexible manufacturing systems between the proposed ELECTRE method and the existing intuitionistic fuzzy technique for order preference by similarity to ideal solution (IF-TOPSIS) method. 相似文献
7.
Microchimica Acta - Graphene oxide nanosheets were modified with magnetite nanoparticles, and a hyperbranched polyamidoamine dendrimer was then covalently attached to their surface. The resulting... 相似文献
8.
9.
The separation of Cd(II) and Ni(II) ions was studied in an aqueous sulphate medium using supported liquid membrane (SLM). D2EHPA/M2EHPA was used as a mobile carrier, microporous hydrophobic PTFE film was used as a solid support for the liquid membrane, and the strip phase was sulphuric acid. The effects of different parameters such as feed concentration, carrier concentration, feed phase pH, and strip phase pH on the separation factor and flux of Cd(II) and Ni(II) ions were studied. The optimum values obtained to achieve the maximum flux were 5.0 for feed pH, 40 vol. % for D2EHPA/M2EHPA concentration in the membrane phase, 0.5 for strip pH, and 0.012 mass % for feed concentration. Under these optimum conditions, the flux values of Cd(II) and Ni(II) were 15.7 × 10?7 kg m?2 s?1 and 2.6 × 10?7 kg m?2 s?1, respectively. The separation factors of Cd(II) over Ni(II) were studied under different experimental conditions. At a carrier concentration of 10 vol. % and feed concentration of 0.012 mass %, the maximum value of 185.1 was obtained for the separation factor of Cd(II) over Ni(II). After 24 h, the percentages of the extracted Cd(II) and Ni(II) were 83.3 % and 0.45 %, respectively. 相似文献
10.