排序方式: 共有71条查询结果,搜索用时 125 毫秒
1.
F. Trandafir P. Heerdt M. Fittipaldi E. Vinck S. Dewilde L. Moens S. Van Doorslaer 《Applied magnetic resonance》2007,31(3-4):553-572
In this work, the high-spin ferric form of the E7Q mutant of human neuroglobin (E7Q-NGB) is studied by X-band continuous-wave electron paramagnetic resonance (CW EPR) and hyperfine sublevel correlation (HYSCORE) spectroscopy. It is shown that the use of matched pulses in the HYSCORE experiment is essential to observe the nitrogen spectral contributions. The validity of approximating the high-spin Fe(III) system (S=5/2) as an effectiveS=1/2 system is tested and the consequences for the HYSCORE simulations are highlighted. Comparative HYSCORE experiments combined with deuterium exchange experiments for aquometmyoglobin and ferric E7Q-NGB clearly show that the heme iron of the latter protein is pentacoordinated, lacking the distal water. Furthermore, CW EPR experiments show that, at high pH, the E10K residue is coordinating to the heme iron in this globin. These observations are corroborated by resonance Raman experiments and could also be reproduced for other E7 mutants of human and mouse neuroglobin. Finally, the proton and nitrogen hyperfine and nuclear quadrupole parameters obtained for ferric E7Q-NGB are discussed in detail. 相似文献
2.
Budrugeac P. Trandafir Viorica Albu Madalina Georgiana 《Journal of Thermal Analysis and Calorimetry》2003,72(2):581-585
The methods of the thermal analysis (TG, DTG and DTA) were used in order to investigate the effect of the hydration degree
on the thermal behaviour of some collageneous matrices. It was pointed out that the degradation of hydrated collagen in the
temperature range 20-400°C occurs through two successive processes accompanied by mass losses. The first process, consisting
in the collagen dehydration, is endothermic and takes place in the temperature range ≈25 - ≈125°C. The second process is exothermic
and consists in the decomposition and/or thermo-oxidation of dry collagen. The thermal parameters of both processes depend
on the hydration degree of collagen. The observed dependencies show that the hydrothermal and thermo-oxidative stability of
collagen are strongly correlated with its water content.
This revised version was published online in July 2006 with corrections to the Cover Date. 相似文献
3.
Belz J Cousins RD Diwan MV Eckhause M Ecklund KM Hancock AD Highland VL Hoff C Hoffmann GW Irwin GM Kane JR Kettell SH Klein JR Kuang Y Lang K Martin R May M McDonough J Molzon WR Riley PJ Ritchie JL Schwartz AJ Trandafir A Ware B Welsh RE White SN Witkowski MT Wojcicki SG Worm S 《Physical review letters》1996,76(18):3277-3280
4.
Tiberiu-M. Gianga Edwige Audibert Anamaria Trandafir Gabriele Kociok-Khn G. Dan Panto 《Chemical science》2020,11(35):9685
We report herein the first all-donor aromatic [2]catenane formed through dynamic combinatorial chemistry, using single component libraries. The building block is a benzo[1,2-b:4,5-b′]dithiophene derivative, a π-donor molecule, with cysteine appendages that allow for disulfide exchange. The hydrophobic effect plays an essential role in the formation of the all-donor [2]catenane. The design of the building block allows the formation of a quasi-fused pentacyclic core, which enhances the stacking interactions between the cores. The [2]catenane has chiro-optical and fluorescent properties, being also the first known DCC-disulphide-based interlocked molecule to be fluorescent.An all-donor [2]catenane has been synthesised via dynamic combinatorial chemistry. It features stacked benzodithiophenes which are quasi-pentacyclic through hydrogen bonding. 相似文献
5.
6.
Anamaria Hosu 《液相色谱法及相关技术杂志》2020,43(9-10):305-318
AbstractOver the last years, thin layer chromatography (TLC) has become an increasingly important tool in the analysis of natural compounds, being used not only as a simple method of separation, identification, and quantitative determination of natural constituents, but also as a method for evaluating the potential applications of the separated compounds, different bioassays being compatible with TLC. This is due to the TLC advantages, of which could be mentioned: the possibility to simply, quickly, and flexibly analyze many samples in parallel, without the need for special steps of sample purification, obtaining visual results, and the possibility of multiple detections, all of these being achieved at very low costs. Considering these, the aim of this study is to give an overview on the application of TLC in evaluation of different biological activities of natural compounds, focusing on antioxidant, enzymatic, antimicrobial, and hormonal activities. 相似文献
7.
Anamaria Durdureanu-Angheluta Lucia Pricop Catalina-Anisoara Peptu Narcisa Marangoci Horia Chiriac Bogdan C. Simionescu 《Journal of magnetism and magnetic materials》2010,322(19):2956-2968
New silicon magnetite ferrofluids were prepared by dispersing siloxane-coated magnetite particles in polydimethylsiloxane with low or high molecular weights. Ferrofluids are stable colloidal dispersions of ultra fine covered magnetite particles, which may be selected for a specific application. We demonstrated new methods of stabilizing the magnetic particles by reacting the hydroxyl groups on the surface of magnetite particles with terminal ethoxy groups of polydimethylsiloxane, followed by their dispersion in silicon fluids. The new silicon ferrofluids were tested from the morphology, magnetic properties/losses, and rheological properties point of view. 相似文献
8.
Cimpoiu C Hosu A Seserman L Sandru M Miclaus V 《Journal of separation science》2010,33(23-24):3794-3799
The aim of this paper is to develop a new simple, fast and economical method for simultaneous quantitative determination of methylxanthine compounds based on TLC combined with image analysis. To obtain certain results, both extraction and chromatographic separation were optimized. The optimum extraction conditions were maceration in ethanol-water 8:2, v/v. The chromatographic separations were done on the silica gel F(254) TLC plates developed with chloroform-dichloromethane-isopropanol, 4:2:1 v/v/v. Detection was performed under UV lamp at 254?nm and the evaluation of the chromatographic plate was based on digital processing of chromatographic images. The developed TLC method was validated for parameters such as specificity, linearity and range, LOD and LOQ, precision, robustness and accuracy. This method was then applied for determination of caffeine, theobromine and theophylline in different types of tea, commercially available. Moreover, the content of methylxanthines detected and determined in commercial tea samples can be used as chemical marker in quality control. 相似文献
9.
Raluca Dumitru Florica Manea Lavinia Lupa Cornelia Păcurariu Adelina Ianculescu Anamaria Baciu Sorina Negrea 《Journal of Thermal Analysis and Calorimetry》2017,128(3):1305-1312
Nanosized cobalt aluminate (CoAl2O4) was prepared by thermolysis of heteronuclear coordination compound, namely [Al2Co(C2O4)4(OH2)6]. The synthesized precursor was characterized by chemical analysis, vibrational spectra and thermal analysis. The cobalt aluminate obtained after a heating treatment of the precursor at 700 °C was characterized by IR, XRD, TEM coupled with SAED measurements. Two types of carbon-based electrodes, glassy carbon and boron-doped diamond electrodes were decorated with the obtained cobalt aluminate in order to enhance the electroanalytical performance for the tetracycline (TC) detection in the aqueous solutions. Cyclic voltammetry technique was used to determine the effect of the nanosized CoAl2O4 on the electrochemical oxidation of TC and as consequence, for TC detection at both carbon-based electrodes. The obtained cobalt aluminate exhibited the electrocatalytic activity toward TC detection in direct relation with the type of the carbon substrate, which allowed enhancing the electroanalytical parameters of TC detection in the aqueous solution. 相似文献
10.
Alexandru C. Razus Liviu Birzan Mihaela Cristea Eugenia Andreea Dragu Anamaria Hanganu 《Monatshefte für Chemie / Chemical Monthly》2011,40(9):1271-1282