首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   14篇
  免费   0篇
化学   7篇
数学   2篇
物理学   5篇
  2017年   1篇
  2014年   1篇
  2012年   1篇
  2011年   2篇
  2010年   2篇
  2006年   1篇
  2005年   1篇
  2004年   1篇
  2000年   2篇
  1999年   1篇
  1974年   1篇
排序方式: 共有14条查询结果,搜索用时 312 毫秒
1.
The time delay experiment proposed by I.I. Shapiro in 1964 and conducted in the seventies was the most precise experiment of general relativity until that time. Further experimentation has improved the accuracy level of both the time delay and the light deflection experiments. A simulation model is proposed that involves only a simple mass and time transformation factor involving velocity of light. The light deflection and the time delay experiments are numerically simulated using this model that does not use the general relativistic equations. The computed values presented in this paper compare well with recent levels of accuracy of their respective experimental results.  相似文献   
2.
A procedure for the determination of As, Cd, Cr, Ni, Pb, and V in phytotherapy medicines by inductively coupled plasma–tandem mass spectrometry is reported. The use of tandem mass spectrometry with oxygen into an octopole reaction system at various gas flow rates and the combination of on-mass and mass-shift modes was evaluated. Cadmium, Cr, Ni, and Pb were determined as free atomic ions while As and V were determined as the oxides AsO+ and VO+ in the same run. Samples were prepared by microwave-assisted digestion with dilute nitric acid and hydrogen peroxide. Two plant-certified reference materials (apple leaves and tomato leaves) were used to check the accuracy. For tandem mass spectrometry with 0.5?mL min?1 O2, recoveries in the 85–113% were typically obtained and no statistical differences were observed at the 95% confidence level (t-test) in comparison with the certified values. Using these conditions, the limits of detection for the method were 0.01, 0.0002, 0.008, 0.008, 0.003, and 0.002?µg g?1 for As, Cd, Cr, Ni, Pb, and V, respectively. The procedure was used for the analysis of four phytotherapic drugs and the determined concentrations were up to 0.168?µg g?1 As, 0.03?µg g?1 Cd, 0.82?µg g?1 Cr, 1.18?µg g?1 Ni, 0.52?µg g?1 Pb, and 2.4?µg g?1 V with average precision values of 8% as the relative standard deviation. The found concentrations were compared with limits proposed in official guidelines and, in most cases, the values were below the maximum limits allowed.  相似文献   
3.
An analytical procedure for direct introduction of biodiesel samples into an inductively coupled plasma mass spectrometer (ICP-MS) by using microemulsion for sample preparation was developed here. Cadmium, Co, Cu, Mn, Ni, Pb, Ti, and Zn were determined in biodiesel microemulsified samples prepared from different oleaginous sources (African palm, castor beans, palm, soybeans and an unknown oleaginous). Microemulsions were prepared using 0.25 mL Triton X-100, 0.25 mL 20% v v− 1 HNO3, 0.50 mL biodiesel sample and 4.0 mL n-propanol. Argon-oxygen mixture was added to the plasma as auxiliary gas for correcting matrix effects caused by the high carbon load due to biodiesel microemulsions. The oxygen gas flow rate was set in 37.5 mL min− 1. The accuracy of the developed procedure was evaluated by applying addition-recovery experiments for biodiesel samples from different sources. Recoveries varied from 76.5 to 116.2% for all analytes but Zn in castor beans biodiesel sample (65.0 to 76.2%). Recoveries lower than 86.6% were obtained for palm biodiesel sample, probably due to matrix effects. Detection limits calculated by using oxygen in the composition of the auxiliary gas added to the plasma were higher than those calculated without using it, probably due to the highest formation of oxides. Despite oxides formation, best analytical performance was reached by using oxygen as auxiliary gas and by proper correction of transport interferences. The developed procedure based on microemulsion formation was suitable for direct introduction of biodiesel samples in ICP-MS.  相似文献   
4.
A method is described for quantification of sulfur at low concentrations on the order of mg kg−1 in biodiesel and diesel fuels using isotope dilution and sector field inductively coupled plasma mass spectrometry (ID-SF-ICP-MS). Closed vessel microwave-assisted digestion was employed using a diluted nitric acid and hydrogen peroxide decomposition medium to reduce sample dilution volumes. Medium resolution mode was employed to eliminate isobaric interferences at 32S and 34S related to polyatomic phosphorus and oxygen species, and sulfur hydride species. The method outlined yielded respective limits of detection (LOD) and limits of quantification (LOQ) of 0.7 mg kg−1 S and 2.5 mg kg−1 S (in the sample). The LOD was constrained by instrument background counts at 32S but was sufficient to facilitate value assignment of total S mass fraction in NIST SRM 2723b Sulfur in Diesel Fuel Oil at 9.06 ± 0.13 mg kg−1. No statistically significant difference at a 95% confidence level was observed between the measured and certified values for certified reference materials NIST SRM 2773 B100 Biodiesel (Animal-Based), CENAM DRM 272b and NIST SRM 2723a Sulfur in Diesel Fuel Oil, validating method accuracy.  相似文献   
5.
We present two new variants of Schur complement domain decompositionpreconditioners suitable for 2D anisotropic problems. Thesevariants are based on adaptations of the probing idea, describedby Chan et al (1992 Fifth Int. Symp. on Domain DecompositionMethods for Partial Differential Equations, Philadelphia: SIAM,pp 236-249), used in conjunction with a coarse grid approximationas introduced by Bramble et al (1986 Math. Comput. 47, 103-134).The new methods are specifically designed for situations wherethe coupling between neighbouring interfaces is stronger thanthe coupling within an interface. Taking into account this strongcoupling, one variant uses a multicolour probing technique toavoid distortion in the probe approximations that appear whenusing the method proposed by Chan et al. The second techniqueuses additional probe matrices to approximate not only the couplingwithin the interfaces but also the coupling between interfacepoints across the subdomains. This latter procedure looks somewhatlike an alternating line relaxation method for anisotropic problems,see Brandt (1977 Math. Comput.. 31, 333-390). To assess therelevance of the new preconditioners, we compare their numericalbehaviour with well known robust preconditioners such as thebalanced Neumann-Neumann method proposed by Mandel (1993 Commun.Numer. Methods Eng.. 9, 233-241).  相似文献   
6.
The ‘anomalous perihelion precession’ of Mercury, announced by Le Verrier in 1859, was a highly controversial topic for more than half a century and invoked many alternative theories until 1916, when Einstein presented his theory of general relativity as an alternative theory of gravitation and showed perihelion precession to be one of its potential manifestations. As perihelion precession was a directly derived result of the full General Theory and not just the Equivalence Principle, Einstein viewed it as the most critical test of his theory. This paper presents the computed value of the anomalous perihelion precession of Mercury's orbit using a new relativistic simulation model that employs a simple transformation factor for mass and time, proposed in an earlier paper. This computed value compares well with the prediction of general relativity and is, also, in complete agreement with the observed value within its range of uncertainty. No general relativistic equations have been used for computing the results presented in this paper.  相似文献   
7.
A method for the determination of sulfur in biodiesel samples by inductively coupled plasma optical emission spectrometry which uses microemulsion for sample preparation and the summation of the intensities of multiple emission lines has been developed. Microemulsions were prepared using 0.5 mL of 20% v/v HNO3, 0.5 mL of Triton X-100, 2-3 mL of biodiesel sample, and diluted with n-propanol to a final volume of 10 mL. Summation of the emission intensities of multiple sulfur lines allowed for increased accuracy and sensitivity. The amounts of sulfur determined experimentally were between 2 and 7 mg L−1, well below legislative standards for many countries. Recoveries obtained ranged from 72 to 119%, and recoveries obtained for the 182.562 nm line were slightly lower. This is most likely due to its lower sensitivity. Using microemulsion for sample preparation and the summation of the intensities of multiple emission lines for the successful determination of sulfur in biodiesel has been demonstrated.  相似文献   
8.
Singh  RS 《数学理论与应用》2000,20(1):128-128
(《马氏决策过程》,侯振挺、郭先平著,长沙,湖南科技出版社,1997,中文版,386页,定价:28元)马尔可夫决策过程是概率论的运筹学的理论研究和实际应用中极其重要的领域之一.随着中国和国际上对马尔可夫决策过程(MarkovDecisionProcesses,简记为MDP)研究的新进展,许  相似文献   
9.
A sensitive and reliable high‐performance liquid chromatography–mass spectrometry (LC–MS/MS) was developed and validated for simultaneous quantification IC87114, roflumilast (RFM), and its active metabolite roflumilast N‐oxide (RFN) using tolbutamide as an internal standard. The analytes were extracted by using liquid–liquid extraction and separated on a reverse phase C18 column (50 mm × 3 mm i.d., 4.6 µ) using methanol: 2 mM ammonium acetate buffer, pH 4.0 as mobile phase at a flow rate 1 mL/min in gradient mode. Selective reaction monitoring was performed using the transitions m/z 398.3 > 145.9, 403.1 >186.9, 419.1 > 187.0 and 271.1 > 155.0 to quantify quantification IC87114, RFM, RFN and tolbutamide, respectively. The method was validated over the concentration range of 0.1–60 ng.mL?1 for RFM and RFN and 6 to 2980 ng.mL?1 for IC87114. Intra‐ and inter‐day accuracy and precision of validated method were within the acceptable limits of <15% at all concentrations. Coefficients of correlation (r2) for the calibration curves were >0.99 for all analytes. The quantitation method was successfully applied for simultaneous estimation of IC87114, RFM and RFN in a pharmacokinetic drug–drug interaction study in Wistar rats. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   
10.
This is the report of Heavy Ion Physics and Quark-Gluon Plasma at WHEPP-09 which was part of Working Group-4. Discussion and work on some aspects of quark-gluon plasma believed to have created in heavy-ion collisions and in early Universe are reported.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号