首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   48篇
  免费   0篇
化学   23篇
力学   1篇
数学   2篇
物理学   22篇
  2019年   4篇
  2013年   2篇
  2011年   3篇
  2009年   1篇
  2007年   1篇
  2004年   1篇
  2003年   1篇
  2002年   1篇
  1999年   6篇
  1998年   3篇
  1996年   1篇
  1995年   3篇
  1994年   2篇
  1993年   5篇
  1992年   3篇
  1991年   2篇
  1990年   1篇
  1989年   1篇
  1988年   2篇
  1986年   3篇
  1982年   2篇
排序方式: 共有48条查询结果,搜索用时 421 毫秒
1.
A systematic study of the efficiency of protons, Ni, Pd and Th as chemical modifiers for the determination of cadmium by electrothermal atomic absorption spectrometry (ETAAS) using fast temperature programs was made for platform atomization. A comparison was made in terms of the salt type, absorbance-time profiles and elimination of the sodium chloride interference. The results were adapted to develop a method for the ETAAS determination of cadmium in biological and environmental samples. The highest sensitivity to determine cadmium in biological and environmental samples was obtained using nickel (together with protons) as a chemical modifier. The accuracy of the method was tested by the determination of cadmium in different certified reference materials. The best detection limit and the characteristic mass of Cd were found to be 0.03 ng mL(-1) and 0.35 pg, respectively.  相似文献   
2.
3.
4.
5.
Robles LC  Aller AJ 《Talanta》1995,42(11):1731-1744
The retention of cadmium by the bacteria Escherichia coli and Pseudomonas putida was optimized in order to develop a rapid and selective preconcentration method for cadmium from biological and environmental samples prior to determination by electrothermal atomic absorption spectrometry. Living and lyophilized cells for both bacteria were used, but the method using dead cells shows better analytical capabilities. Cadmium from aqueous solutions is easily retained on the outer membrane of both bacteria in the pH range 4-10, although the selected working pHs for E. coli and P. putida were 5 and 9, respectively. Cadmium retained by the bacteria was dispersed in 3.5 M nitric acid and the slurry was introduced directly into the graphite tube. The best sensitivity and detection limit were obtained for E. coli (0.03 ng ml(-1) and 0.04 ng ml(-1) respectively, in the absence of any chemical modifier). A strong spectral interference from nickel chloride was found and methods to overcome it were developed. The proposed extraction procedure was tested by the determination of cadmium in different standard biological and environmental samples.  相似文献   
6.
Phosphogypsum discharges by phosphate-ore processing industries pollute sediments of the Rotterdam harbour area with226Ra. Direct measurement of this radionuclide in sediments does not provide a reliable indication of the elevation of the levels, since226Ra levels in sediments depend on the particle size. To eliminate the size effect, the226Ra/Ba ratio in sediments was tested as a possible indicator for the226Ra in the discharges. The results indicate almost a doubling of the226Ra levels in sediment samples due to phosphogypsum discharges. The contribution of phosphogypsum to the sediment mass was calculated in the order of a few percent equivalent.  相似文献   
7.
8.
Fast atom bombardment, combined with high-energy collision-induced tandem mass spectrometry, has been used to investigate gas-phase metal-ion interactions with captopril, enalaprilat and lisinopril, all angiotensin-converting enzyme inhibitors.Suggestions for the location of metal-binding sites are presented. For captopril, metal binding occurs most likely at both the sulphur and the nitrogen atom. For enalaprilat and lisinopril, binding preferably occurs at the amine nitrogen. Copyright 1999 John Wiley & Sons, Ltd.  相似文献   
9.
Electrothermal atomization of beryllium from graphite and tungsten surfaces was compared with and without the use of various chemical modifiers. Tungsten proved to be the best substrate, giving the more sensitive integrated atomic absorption signals of beryllium. Tungsten platform atomization with zirconium as a chemical modifier was used for the determination of beryllium in several NIST SRM certified reference samples, with good agreement obtained between the results found and the certified values. The precision of the measurements (at 10 μg L−1), the limit of detection (3σ), and the characteristic mass of beryllium were 2.50%, 0.009 μg L−1 and 0.42 pg, respectively.  相似文献   
10.
Applications of DCEMS or ICEMS for UHV studies of surfaces and interfaces are often severely limited by long recording times. To clarify the practical means to shorten this time, we introduce the “statistical utility rate” α characterizing the statistical quality of a given measurement. By improving detection efficiency and reducing background contribution simultaneously, we have developed an extremely low-noise scintillation detector (Hamamatsu R1635-02 or R2557 photomultiplier with P-47 thin-layer phosphor). Performance comparison with a channeltron by57Fe-DCEMS measurements on an 90% enriched57Fe foil with 7.2 keV electrons reveals a measuring time gain over an order of magnitude in favour of the scintillation e-detector. Improvements achievable for samples with normal isotope abundance are higher than for enriched ones.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号