首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   115篇
  免费   5篇
化学   58篇
力学   6篇
数学   1篇
物理学   55篇
  2023年   1篇
  2022年   2篇
  2021年   5篇
  2020年   1篇
  2018年   1篇
  2017年   4篇
  2016年   9篇
  2015年   5篇
  2014年   7篇
  2013年   10篇
  2012年   4篇
  2011年   6篇
  2010年   5篇
  2009年   10篇
  2008年   6篇
  2007年   10篇
  2006年   7篇
  2005年   8篇
  2004年   6篇
  2002年   1篇
  2000年   1篇
  1997年   3篇
  1996年   2篇
  1995年   1篇
  1991年   1篇
  1988年   1篇
  1986年   1篇
  1981年   1篇
  1973年   1篇
排序方式: 共有120条查询结果,搜索用时 187 毫秒
1.
Air monitoring is the quantitative-qualitative assessment of the extent of pollutants. It is performed to ensure compliance with legislation and to evaluate control measures and mitigation solutions. There are numerous approaches to measure airborne formaldehyde (FA), ranging from passive sampling techniques to remote sensing devices. Research of sampling procedures and analytical methods was performed in a scientific database and on the web to offer a scenario of the devices and techniques that can be used to assess FA exposure. Moreover, in the design of FA assessment, some crucial aspects were considered, such as standard atmosphere generation for devices calibration. This review summarizes the tools and basics used in FA air monitoring, useful to organize a functional monitoring strategy for assessment of FA concentration levels. An insight into the sampling and analysis of FA is provided. Recent advances in solid sorbent technology allow analysts to use these devices coupled to chromatographic instruments. A comparison of the strengths and weaknesses of analytical methods (gas-/liquid-chromatography coupled with mass spectrometry or UV detection, chromogenic, colorimetric, electrochemical determination) and sampling devices (impregnated papers, solid sorbents, liquid sorbents, bubblers, impingers, micro-impingers, denuder samplers, sealed bags, canisters) methods are illustrated. This survey found that a monitoring strategy should be planned considering the most appropriate methodology in terms of costs and practicability. Therefore, it is necessary to know the aspects that can make the chosen strategy suitable and valid for the exposure scenario under investigation.  相似文献   
2.
Since the outbreak of the COVID-19 pandemic, most countries have recommended their citizens to adopt social distance, hand hygiene, and face mask wearing. However, wearing face masks has not been well adopted by many citizens. While the reasons are complex, there is a general perception that the evidence to support face mask wearing is lacking, especially for the general public in a community setting. Face mask wearing can block or filter airborne virus-carrying particles through the working of colloid and interface science. This paper assesses current knowledge behind the design and functioning of face masks by reviewing the selection of materials, mask specifications, relevant laboratory tests, and respiratory virus transmission trials, with an overview of future development of reusable masks for the general public. This review highlights the effectiveness of face mask wearing in the prevention of COVID-19 infection.  相似文献   
3.
曹阳  荣健  张红民  包明  王培容  郭靖 《光子学报》2014,43(8):806002
为避免经典固定模型集合中多模型算法造成的模型间竞争并减小计算量,基于有向图切换的变结构方法,建立有向图切换规则和较完备的模型集合.通过模糊逻辑推理得到模型集合中各模型的匹配度,以此代替传统多模型算法中的模式概率来计算,降低了计算的复杂度.采用核粒子滤波克服了标准粒子滤波没有考虑到的量测信息问题,即粒子能够通过核密度估计后朝着状态的后验概率密度的模型移动,使真实和估计模型之间的均方误差最小.仿真结果表明,基于模糊理论的变结构核粒子滤波算法能较大地提高跟踪准确度和减少计算量.  相似文献   
4.
根据机载激光通信的环境和链路距离,采用光电粗精复合轴结构,提出一种双探测器、双光轴机载激光通信复合轴捕获跟踪瞄准系统方案.对整个系统的光路结构进行了分析和优化设计,使粗跟踪精度达120 μrad,精跟踪系统带宽大于300 Hz,执行动态范围达5 mrad,跟踪精度达3 μrad,并成功实现通信距离17.5 km、通信速率1.5 Gbps,误码率达1E-7的飞机对地面激光通信实验.  相似文献   
5.
为了解决机载铂电阻测温系统机上校准工作量大、实施难等问题,根据机载铂电阻测温原理和校准方法,分析了对于单个测温通道在实验室与机载环境下测量结果之间的差异,提出了一种对实验室校准曲线进行修正而替代机上校准曲线的方法,并通过实验对该方法进行验证;设计了根据机载测试系统的数据文件、系统配置文件,批量修正实验室校准曲线的软件;任意选择的8个参数进行工程验证,采用原方法和本文方法进行校准得到的两组校准曲线,分别对测试数据进行处理,得到测量结果的最大偏差与量程比不超过0.27%,证明修正后实验室校准曲线与机上校准曲线基本一致,可以用作数据处理;结果证明,改进后校准方法方便、高效,校准结果满足机载测试要求,为机载参数校准提供了新思路。  相似文献   
6.
7.
田心宇  姚英  肖佳伟 《应用声学》2016,24(6):185-188
机载计算机是无人机的核心部件,其可靠性高低直接决定了系统的安全。余度技术作为机载计算机可靠性设计的一项重要手段,对提高系统的应变能力,实现故障隐蔽以消除故障,改善系统性能有十分重要的作用。但是在余度技术中不同通道之间会存在一定的时钟误差,如果不进行处理将会使其无法达到无缝切换,从而影响系统的安全。在对机载计算机内部通道间不同步的原因进行详细分析的基础上,提出了一种软、硬件相结合的同步算法,并以三余度机载计算机为例进行了实际测试。测试结果证明该策略实现简单、同步效果好,异步度完全满足系统要求且付出的软、硬件代价小,显著提高了全系统的可靠性及可维护性。  相似文献   
8.
In this study, ultrasound either as a pretreatment technique or as an integrated technique was employed to enhance fluidized bed drying of Ascophyllum nodosum, and drying kinetics and dried product quality were assessed. In order to compare technology efficiency and dried product qualities, oven drying and fluidized bed drying (FBD) were employed. The novel drying methods included airborne ultrasound-assisted fluidized bed drying (AUA), ultrasound pre-treatment followed by FBD (USP), and hot water blanching pre-treatment followed byFBD (HWB). Six drying kinetics models were used to describe the drying curves, among which the Page model was the best in fitting USP and AUA. Model by Millidi et al. was employed to describe HWB. Airborne ultrasound in AUA did not reduce energy consumption or drying time, but retained total phenolic content (TPC) as well as colour, and exhibited the highest yield among the novel drying methods. USP and HWB showed lower energy consumption and drying time considerably, but the TPC was the lowest among the studied methods. At the same time, USP dried product exhibited the lowest aw, followed by HWB and then AUA. This studyalso demonstrated that FBD could be a very practical drying method on Irish brown seaweed, and ultrasound-assisted drying methods may have potential developments in Irish brown seaweed drying process.  相似文献   
9.
A detailed statistical examination of replicated data used to certify platinum-group elements (PGEs) in environmental reference material BCR-723 is presented. Certification of Pt, Pd, and Rh concentrations in BCR-723 was based on 16, eight, and nine accepted data sets, respectively. Each accepted data set contained six replicated measurements for each PGE, and the statistical properties of these concentration data were examined, i.e. 96 for Pt, 48 for Pd, and 54 for Rh. This level of investigation has received limited attention but is critical in furthering our understanding of PGE variability and representativeness. Concentrations of Pt, Pd, and Rh were shown to differ significantly between accepted data sets. Palladium and Pt differed in their quantification between detection techniques. Additionally, Pd and Pt concentrations varied significantly between laboratories using a similar definitive method (inductively coupled plasma-isotope dilution mass spectrometry). The distribution of Pd concentrations was found to be bimodal, with a secondary population exhibiting a contamination signal of about 15%. The secondary population, not previously reported in BCR-723, is likely a measurement artifact and not due to a nugget effect. Comparisons of BCR-723 with other environmental media from Europe, i.e. airborne particulate matter, tunnel dust, and road-deposited sediment, indicated that Pd is uncommonly low in BCR-723 (6.0?ng?g?1) and is generally not representative in terms of its distribution relative to Pt and Rh. Serious consideration should be given to developing a new PGE certified environmental reference material.  相似文献   
10.
Hexavalent chromium Cr(VI) is a well-established carcinogen associated with lung, nasal, and sinus cancer. Cr(VI) threshold limit values in workroom air have been recently lowered. Consequently, the currently available analytical methods are insufficiently sensitive or high cost. In this paper, a simple, cost-effective, sensitive, and reproducible method using solid-phase extraction with electrothermal atomic absorption spectrometry for determination of hexavalent chromium in airborne samples is reported. The method validation included selectivity, linearity, accuracy, and precision. Interferences from other ions likely to be present in airborne samples, including trivalent chromium, were tested and selectivity was demonstrated. The detection and quantification limits were, respectively, as low as 0.1 and 0.4?µg?L?1. The linearity ranged from 0.5 to 50.0?µg?L?1, with a regression coefficients exceeding 0.998. The extraction recovery exceeded 98%. The developed method was successfully compared with a reference spectrophotometric method. The performances achieved were similar to ion chromatography and high-performance liquid chromatography approaches. The novel method was tested on airborne samples collected from the workplace. The method’s performance suggests that it may be an alternative to high-cost techniques for monitoring occupational exposure to hexavalent chromium.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号