首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   38篇
  免费   0篇
化学   38篇
  2017年   1篇
  2014年   1篇
  2012年   5篇
  2011年   1篇
  2010年   1篇
  2008年   2篇
  2007年   3篇
  2006年   1篇
  2005年   1篇
  2004年   5篇
  2003年   2篇
  2002年   2篇
  2001年   2篇
  1997年   2篇
  1996年   1篇
  1995年   2篇
  1994年   1篇
  1993年   2篇
  1992年   1篇
  1991年   1篇
  1989年   1篇
排序方式: 共有38条查询结果,搜索用时 46 毫秒
1.
催化光度返滴定法测定微量锰的研究   总被引:1,自引:0,他引:1  
本文研究了催化光度反滴定法测定微量锰的原理,找到最佳实验条件,确立了实验方法,测定波长622nm;反应时间1min40s;活化剂NTA用量0.60mL,KIO4与孔雀石绿用量比为1.00:0.35,室温下滴定;用pH=5.4的乙酸-乙酸钠缓冲溶液控制溶液酸度;测定Mn^2+的浓度范围为1×10^-7~1×10^-5mol/L,Co^2+,Bi^3+,Ca^2+,Al^3+,Pb^2+,Cu^2+,  相似文献   
2.
The advantages of using diodes as thermal sensors in solution thermochemistry are discussed and a simple, low-cost circuit for the use of diodes as temperature sensors is reported. In preliminary studies, the titration of TRIS and hydrochloric acid is used to compare the precision of thermistors and diodes in thermometric titrimetry. Several systems are assayed at various temperatures by enthalpimetric methods to illustrate the advantages of diodes as sensors for monitoring thermal methods capable of being used in quality control system.  相似文献   
3.
Multiwalled carbon nanotubes were modified by carboxy groups. Four independent methods for the determination of the degree of functionalization of the surface were proposed: 13C NMR spectroscopy, thermogravimetry, titrimetry, and fluorimetry. The first two methods show the total content of carboxy groups in the sample, and the latter two methods give information about the content of the surface groups only. Published in Russian in Izvestiya Akademii Nauk. Seriya Khimicheskaya, No. 2, pp. 291–295, February, 2008.  相似文献   
4.
影响混合酸中各组分含量测定的因素及条件   总被引:1,自引:1,他引:0  
李汉洙 《分析化学》1995,23(7):801-804
作者曾提出,两种一元弱酸混合酸以及强酸与一元弱酸混合酸中,第一终点pH〉3.7的情况下,测定各组分酸含量的方法。在此基础上,本文在理论上推导出第一终点pH值测量误差ΔpH与分析结果的误差ΔVe2/Ve^T之间的关系式,从而明确了影响误差的因素,并提出误差ΔVe2/Ve^T≤1.0%时的测定条件以及第一终点pH〈3.7时的测定方法。实验结果表明,如果能满足本文提出的条件,可以获得满意的结果。  相似文献   
5.
The present work addresses the protolytic charge of montmorillonite, which occurs on the broken-bond sites at the particle edges. The purpose is to overcome the general difficulty arising in potentiometric titration due to coupled side reactions, which severely impede the titrant budget (partial dissolution of the clay and of secondary phases, hydrolysis and readsorption of dissolved species, cation exchange). Batch potentiometric titrations were carried out on the montmorillonite fractions extracted from two bentonites (MX80 and SWy2) to quantify their protolytic charge. The effects of equilibration time (24 h and 7 days), pH from 4 to 10, and ionic strength (0.1 and 0.01 mol L(-1)) were extensively studied for the MX80 sample. Quantification of dissolution was achieved by analysis of the equilibrium solutions for dissolved species and by La(3+) exchange of the readsorbed species. The results clearly show that secondary phases such as iron- or silica-rich minerals contribute to the dissolved species, according to the nature of the raw bentonite. Furthermore, readsorption affects significant amounts of dissolved species. The overconsumption of proton/hydroxide due to dissolution, readsorption, and hydrolysis of dissolved species was evaluated using a self-consistent thermodynamic calculation. The ability of such calculation to correct the raw titration curves in order to extract the titrable surface charge of montmorillonite was evaluated by comparison with the continuous titration procedure. Especially in the alkaline domain, correcting the raw batch titration curves for the measured side reactions failed to reproduce the continuous titration curves. These observations demonstrate the limitations of the batch titration method and the superiority of fast, continuous methods for quantifying the dissociable surface charge of clays.  相似文献   
6.
钛铁矿中钛的测定   总被引:1,自引:0,他引:1  
利用钛铁矿能显著吸收微波的介电特性,采用家用微波炉,在微波辐照下,用浓磷酸消解矿样,并用氧化还原滴定法测定钛的含量,试验结果表明,该方法能快速分解矿样,测定结果准确,与传统分析方法比较,该法具有简便、快速、低耗、适应大批量样品分析等优点。还对钛铁矿的结构作了X-射线衍射分析。  相似文献   
7.
杨建男  张燕华 《分析化学》1993,21(2):228-230
用具有流通池的分光光度计作测定装置,建立了由平衡移动法测定络合反应中质子释放数的新方法。方法简单、快速,仅用一个标准溶液,适于在变更pH值范围内金属离子不发生水解和没有其他副反应的体系。  相似文献   
8.
张云  谭超 《分析试验室》2004,23(1):9-12
导出了沉淀单点滴定法与双点滴定法计算式。以银电极为指示电极 ,Ag 标准溶液为滴定剂 ,对Cl-、Br-、I-及SCN-等离子的测定进行了研究 ;对影响测定结果准确度的因素进行了讨论。实验发现 ,在α =1 .0~ 1 .1的条件下 ,单点滴定法有较高的准确度 ;在α1 ≈ 1 .0~ 1 .1、ΔV =0 .5~ 1 .0mL的条件下 ,双点滴定法有较高的准确度  相似文献   
9.
综述了从1986-2012年间电位滴定法在药物分析中的应用,主要涉及在此领域中的研究工作,不同电位滴定方法在不同类型药物分析中的应用以及对未来发展的展望(引用文献48篇)。  相似文献   
10.
滴定计算分析法同时测定Fe(Ⅲ)与Fe(Ⅱ)的研究   总被引:1,自引:0,他引:1  
以铂电极为指示电极,Ce^4 标准溶液为滴定剂,对氧化还原滴定计算分析法同时测定Fe(Ⅲ)与Fe(Ⅱ)进行了研究。导出了同时测定Fe(Ⅲ)与Fe(Ⅱ)的滴定计算式。结果表明,电极的系统误差是影响测定结果准确度的主要因素,而且系统误差对Fe(Ⅲ)的影响比较大,对Fe(Ⅱ)的影响比较小。用刚开始滴定的实验数据,Fe(Ⅲ)的误差比较小;用接近化学计量点的实验数据,Fe(Ⅱ)的误差比较小。  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号