首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   17篇
  免费   2篇
  国内免费   2篇
化学   17篇
物理学   4篇
  2019年   1篇
  2018年   2篇
  2017年   2篇
  2016年   3篇
  2014年   2篇
  2013年   1篇
  2012年   5篇
  2011年   1篇
  2009年   1篇
  2008年   1篇
  2007年   1篇
  2004年   1篇
排序方式: 共有21条查询结果,搜索用时 657 毫秒
1.
Levofloxacin, pefloxacin, ciprofloxacin and moxifloxacin are four fluoroquinolones used in the treatment of serious bacterial infections. The antibacterial activity of fluoroquinolones is concentration dependent. Therefore, therapeutic drug monitoring in daily clinical practice is warranted to ensure the therapy's efficacy and prevent bacterial resistance. The purpose of the present study was to develop a method using high‐pressure liquid chromatography with an ultraviolet detector for simultaneous quantification of these four fluoroquinolones in human plasma. A 50 μL aliquot of plasma was precipitated by 200 μL of methanol using gatifloxacin as internal standard. The chromatographic separation was performed on a Kinetex XB‐C18 column using a mobile phase composed of a mixture of orthophosphoric acid 0.4% (v/v), acetonitrile and methanol at a flow rate of 1.2 mL/min. Dual UV wavelength mode was used, with levofloxacin and moxifloxacin monitored at 293 nm, and pefloxacin and ciprofloxacin monitored at 280 nm. The calibration was linear over the ranges of 0.125–25 mg/L for levofloxacin, 0.1–20mg/L for moxifloxacin and 0.05‐10 mg/L for both pefloxacin and ciprofloxacin. Inter‐ and intra‐day trueness and precision were <13% for all the compounds under study. The proposed method was simple, reliable, cost‐effective and suitable for therapeutic drug monitoring or pharmacokinetics studies.  相似文献   
2.
Moxifloxacin is a representative of the fourth generation of fluoroquinolones. It possesses bacteriostatic activity against Gram-positive and Gram-negative bacteria. A simple and fast high performance liquid chromatography-ultraviolet detection (HPLC-UV) method was developed for moxifloxacin analysis. The separation was performed on C18 column. The mobile phase was a mixture of acetonitrile and 0.4% triethylamine solution. The regression curve was linear over the range 0.2–10.0?µg/mL. The validation parameters obey the European Medicine Agency limits. The in vivo study confirmed the practical application of the method.  相似文献   
3.
The interaction between moxifloxacin (MXFX) and Bovine Hemoglobin (BHb) was investigated at different temperatures by fluorescence spectroscopy. Results showed that the quenching mechanism of MXFX on BHb was a static quenching process with Förester spectroscopy energy transfer. The primary binding for MXFX was located at β-37 Tryptophan residue in hydrophobic cavity of BHb. Besides, weak negative cooperativity was found in drug's binding with BHb. Synchronous spectra revealed that the microenvironment and the conformation of serum albumin were changed during the reaction. Most antibiotics had no effect on the system of BHb-MXFX, except quinolone antibiotics. The system had good stability.  相似文献   
4.
The widespread occurrence of antibiotics as contaminants in the aquatic environment has increased attention in the last years. The concern over the release of antibiotics into the environment is related primarily to the potential for the development of antimicrobial resistance among microorganisms. This article presents an overview of analytical methodologies for the determination of quinolone (Qs) and fluoroquinolone (FQs), macrolide (MLs), tetracycline (TCs), sulfonamide (SAs) antibiotics and trimethoprim (TMP) in different environmental waters. The analysis of these antibiotics has usually been carried out by high-performance liquid chromatography (HPLC) coupled to mass spectrometry (MS) or tandem mass spectrometry (MS/MS) and to a lesser extent by ultraviolet (UV) or fluorescence detection (FD). A very important step before LC analysis is sample preparation and extraction leading to elimination of interferences and prevention of matrix effect and preconcentration of target analytes.  相似文献   
5.
A highly sensitive, selective and rapid liquid chromatography–electrospray ionization mass spectrometry (LC‐MS) method has been developed and validated for simultaneous determination of moxifloxacin (MFX) and ketorolac (KTC) in rat plasma. Gemifloxacin (GFX) was used as an internal standard (IS). A simple protein precipitation method was used for the extraction of analytes from rat plasma. Effective chromatographic separation of MFX, KTC and GFX was achieved on a Kromasil C18 column (100 × 4.6 mm, 5 µm) using a mobile phase consisting of acetonitrile–10 mm ammonium acetate (pH 2.5)–0.1% formic acid (50:25:25) in an isocratic elution, followed by detection with positive ion electrospray ionization mass spectrometry using target ions of [M + H]+ at m/z 402 for MFX, m/z 256 for KTC and m/z 390 for GFX in selective ion recording mode. The method was validated over the calibration range of 5–100 ng/mL for MFX and 10–6000 ng/mL for KTC. The method demonstrated good performances in terms of intra‐ and inter‐day precision (0.97–5.33%) and accuracy (93.91–101.58%) for both MFX and KTC, including lower and upper limits of quantification. The recoveries from spiked control samples were >75% for MFX and >79% for KTC. The matrix effect was found to be negligible and the stability data were within acceptable limits. Further, the method was also successfully applied to a single‐dose pharmacokinetic study in rats. This method can be extended to measure plasma concentrations of both drugs in human to understand drug interaction and adverse effects. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   
6.
目的探究成人支原体肺炎治疗中采用莫西沙星进行治疗的临床治疗效果。方法选择广州市南沙区第二人民医院在2013年5月至2015年5月期间收治的成人支原体肺炎患者220例,采用随机数字法将其分为对照组和实验组,每110例为1组,对照组采用阿奇霉素进行治疗,而实验组则采用莫西沙星进行治疗,将两组患者的治疗效果进行对比分析。结果与对照组相比,实验组患者的治疗总有效率明显较高,而不良反应发生率明显较低,两项差异对比均P0.05,存在统计学意义。结论在成人支原体肺炎治疗中采用莫西沙星有显著的效果,值得在临床上应用推广。  相似文献   
7.
A highly selective, sensitive and accurate HPLC method has been developed and validated for the estimation of three fluoroquinolones (FQs) viz., gatifloxacin (GFC), sparfloxacin (SFC) and moxifloxacin (MFC) with 500 microL human plasma using levofloxacin (LFC) as an internal standard (IS). The sample preparation involved simple liquid-liquid extraction of GFC, SFC, MFC and IS from human plasma with ethyl acetate. The resolution of peaks was achieved with phosphate buffer (pH 2.5)-acetonitrile (80:20, v/v) at a flow rate of 1 mL/min on a Kromasil C(18) column. The total chromatographic run time was 18.0 min and the simultaneous elution of GFC, SFC, MFC and IS occurred at approximately 10.8, 12.8, 17.0 and 6.0 min, respectively. The method proved to be accurate and precise at linearity range of 100-10,000 ng/mL with a correlation coefficient (r) of > or =0.999. The limit of quantitation for each of the FQs studied was 100 ng/mL. The intra- and inter-day precision and accuracy values found to be within the assay variability limits as per the FDA guidelines. The developed assay method was applied to a pharmacokinetic study in human volunteers following oral administration of 400 mg GFC tablet.  相似文献   
8.
《Analytical letters》2012,45(18):2882-2890
The fragmentation of patterns of moxifloxacin, 2-N-methylated moxifloxacin (analog 1), and 1-cyclopropyl-6,7-difluoro-8-methoxy-4-oxo-3-quinolinecarboxylic acid (analog 2) were investigated by electrospray ionization quadrupole time-of-flight tandem mass spectrometry in the positive-ion mode. Many unusual ions were detected in the tandem mass spectra of moxifloxacin. Although the structures of moxifloxacin and analog 1 were similar, the relative abundances of products varied greatly. Comparison of the relative abundances of the product ions that lost CO2 or H2O and complementary product ions resulting from sequential four-membered hydrogen rearrangement showed that the differences were related to the protonation sites. The loss of HF, probably though the formation of an ion/neutral complex, is of scientific interest. The identities of the major product ions were confirmed by deuterium-labeling experiments that demonstrated an unusual loss of a deuterium atom. The major differences in fragmentation patterns were compared to previous reports in the literature.  相似文献   
9.
A flow injection method including chemiluminescence detection has been developed and applied to the determination of fluoroquinolones levofloxacin, moxifloxacin and trovafloxacin in tablets. The proposed method is based on the luminescent properties of the system Ce(IV)–sulphite–fluoroquinolone and the addition of a trivalent lanthanide ion as emission-sensitizer. The optimum conditions for chemiluminescence emission were investigated for each fluoroquinolone. The best results were achieved when employing Eu(III) as lanthanide cation for levofloxacin and moxifloxacin, and Tb(III) for trovafloxacin. These fluoroquinolones were determined over the concentration range of 0.5–3.5µgmL–1, 0.2–3.0µgmL–1 and 0.008–0.400µgmL–1, with detection limits of 0.100, 0.035 and 0.008µgmL–1, respectively. The relative standard deviations were in the range of 1.0–2.5% for all three cases. The method was applied to the determination of three fluoroquinolones in their respective pharmaceutical preparations and compared with an independent UV-spectrophotometric method. The results were satisfactory.  相似文献   
10.
目的比较莫西沙星与左氧氟沙星治疗下呼吸道感染的临床效果。方法选取94例下呼吸道感染患者,随机分为对照组(47例)与观察组(47例),分别采取左氧氟沙星和莫西沙星治疗。统计两组患者喘息、发热、咳嗽等症状消失时间及住院天数,观察治疗效果。结果对照组与观察组治疗总有效率分别为91.5%和95.7%,比较无统计学意义(P0.05)。较对照组,观察组喘息消失时间、发热消失时间、咳嗽消失时间及住院天数[(3.6±1.8)、(4.2±1.6)、(2.6±2.2)、(7.5±1.8)]d明显更优(P0.05)。结论莫西沙星与左氧氟沙星治疗下呼吸道感染疗效相当,莫西沙星在迅速改善临床症状、促进患者康复方面更具优势。  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号