全文获取类型
收费全文 | 870篇 |
免费 | 68篇 |
国内免费 | 65篇 |
专业分类
化学 | 983篇 |
力学 | 1篇 |
综合类 | 2篇 |
物理学 | 17篇 |
出版年
2023年 | 6篇 |
2022年 | 16篇 |
2021年 | 6篇 |
2020年 | 16篇 |
2019年 | 30篇 |
2018年 | 14篇 |
2017年 | 23篇 |
2016年 | 31篇 |
2015年 | 49篇 |
2014年 | 46篇 |
2013年 | 56篇 |
2012年 | 69篇 |
2011年 | 61篇 |
2010年 | 49篇 |
2009年 | 75篇 |
2008年 | 57篇 |
2007年 | 63篇 |
2006年 | 56篇 |
2005年 | 66篇 |
2004年 | 66篇 |
2003年 | 69篇 |
2002年 | 49篇 |
2001年 | 12篇 |
2000年 | 11篇 |
1999年 | 3篇 |
1998年 | 1篇 |
1997年 | 1篇 |
1996年 | 1篇 |
1995年 | 1篇 |
排序方式: 共有1003条查询结果,搜索用时 34 毫秒
1.
The analysis of vitamin D status, with special emphasis on 25-hydroxyvitamin D and 1,25-dihydroxyvitamin D, is gaining interest in clinical studies due to the classical and non-classical effects attributed to this prohormone. In this research, the influence of the two steps preceding determination (viz. sample collection and preparation) on the quantitative analysis of vitamin D and its more important metabolites has been studied. Two preparation approaches, deproteination and solid-phase extraction (SPE), have been evaluated in terms of sensitivity to delimit their application, thus establishing that detection of 1,25-dihydroxyvitamin D cannot be addressed by protein precipitation. Concerning sample collection, serum and plasma reported high accuracy (above 83.3%) for vitamin D and metabolites, while precision, expressed as relative standard deviation, was below 12.9% for all analytes in both samples. Statistical analysis revealed that serum and plasma provided similar physiological levels for vitamin D3, 24,25-dihydroxyvitamin D3 and 25-hydroxyvitamin D3, while significantly different levels were obtained for 1,25-dihydroxyvitamin D3, always higher in plasma than in serum. Sample collection and treatment have proved to be significant in the analysis of vitamin D and its relevant metabolites. 相似文献
2.
Dr. Dmitry B. Eremin Ekaterina A. Denisova Dr. Alexander Yu. Kostyukovich Dr. Jonathan Martens Dr. Giel Berden Prof. Dr. Jos Oomens Prof. Dr. Victor N. Khrustalev Prof. Dr. Victor M. Chernyshev Prof. Dr. Valentine P. Ananikov 《Chemistry (Weinheim an der Bergstrasse, Germany)》2019,25(72):16564-16572
N-Heterocyclic carbene (NHC) ligands are ubiquitously utilized in catalysis. A common catalyst design model assumes strong M–NHC binding in this metal–ligand framework. In contrast to this common assumption, we demonstrate here that lability and controlled cleavage of the M−NHC bond (rather than its stabilization) could be more important for high-performance catalysis at low catalyst concentrations. The present study reveals a dynamic stabilization mechanism with labile metal–NHC binding and [PdX3]−[NHC-R]+ ion pair formation. Access to reactive anionic palladium intermediates formed by dissociation of the NHC ligands and plausible stabilization of the molecular catalyst in solution by interaction with the [NHC-R]+ azolium ion is of particular importance for an efficient and recyclable catalyst. These ionic Pd/NHC complexes allowed for the first time the recycling of the complex in a well-defined form with isolation at each cycle. Computational investigation of the reaction mechanism confirms a facile formation of NHC-free anionic Pd in polar media through either Ph–NHC coupling or reversible H–NHC coupling. The present study formulates novel ideas for M/NHC catalyst design. 相似文献
3.
Xiaoli Liu Michelle M. T. Jansman Peter W. Thulstrup Ana C. Mendes Ioannis S. Chronakis Leticia Hosta‐Rigau 《Macromolecular bioscience》2020,20(2)
Despite all the attempts to create advanced hemoglobin (Hb)‐based oxygen carriers (HBOCs) employing an encapsulation platform, major challenges including attaining a high Hb loading and long circulation times still need to be overcome. Herein, the fabrication, for the first time, of nanoparticles fully made of Hb (Hb‐NPs) employing the electrospray technique is reported. The Hb‐NPs are then coated by antioxidant and self‐polymerized poly(dopamine) (PDA) to minimize the conversion of Hb into nonfunctional methemoglobin (metHb). The PDA shell is further functionalized with poly(ethylene glycol) (PEG) to achieve stealth properties. The results demonstrate that the as‐prepared Hb‐NPs are hemo‐ and biocompatible while offering antioxidant protection and decreasing the formation of metHb. Additionally, decoration with PEG results in decreased protein adsorption onto the Hb‐NPs surface, suggesting a prolonged retention time within the body. Finally, the Hb‐NPs also preserve the reversible oxygen‐binding and releasing properties of Hb. All in all, within this study, a novel HBOCs with high Hb content is fabricated and its potential as an artificial blood substitute is evaluated. 相似文献
4.
Anneli Kruve Riin Rebane Karin Kipper Maarja-Liisa Oldekop Hanno Evard Koit Herodes Pekka Ravio Ivo Leito 《Analytica chimica acta》2015
This is the part II of a tutorial review intending to give an overview of the state of the art of method validation in liquid chromatography mass spectrometry (LC–MS) and discuss specific issues that arise with MS (and MS–MS) detection in LC (as opposed to the “conventional” detectors). The Part II starts with briefly introducing the main quantitation methods and then addresses the performance related to quantification: linearity of signal, sensitivity, precision, trueness, accuracy, stability and measurement uncertainty. The last section is devoted to practical considerations in validation. With every performance characteristic its essence and terminology are addressed, the current status of treating it is reviewed and recommendations are given, how to handle it, specifically in the case of LC–MS methods. 相似文献
5.
Shibdas Banerjee Prof. Richard N. Zare 《Angewandte Chemie (International ed. in English)》2015,54(49):14795-14799
A Pomeranz–Fritsch synthesis of isoquinoline and Friedländer and Combes syntheses of substituted quinolines were conducted in charged microdroplets produced by an electrospray process at ambient temperature and atmospheric pressure. In the bulk phase, all of these reactions are known to take a long time ranging from several minutes to a few days and to require very high acid concentrations. In sharp contrast, the present report provides clear evidence that all of these reactions occur on the millisecond timescale in the charged microdroplets without the addition of any external acid. Decreasing the droplet size and increasing the charge of the droplet both strongly contribute to reaction rate acceleration, suggesting that the reaction occurs in a confined environment on the charged surface of the droplet. 相似文献
6.
7.
Anneli Kruve Riin Rebane Karin Kipper Maarja-Liisa Oldekop Hanno Evard Koit Herodes Pekka Ravio Ivo Leito 《Analytica chimica acta》2015
This is the part I of a tutorial review intending to give an overview of the state of the art of method validation in liquid chromatography mass spectrometry (LC–MS) and discuss specific issues that arise with MS (and MS/MS) detection in LC (as opposed to the “conventional” detectors). The Part I briefly introduces the principles of operation of LC–MS (emphasizing the aspects important from the validation point of view, in particular the ionization process and ionization suppression/enhancement); reviews the main validation guideline documents and discusses in detail the following performance parameters: selectivity/specificity/identity, ruggedness/robustness, limit of detection, limit of quantification, decision limit and detection capability. With every method performance characteristic its essence and terminology are addressed, the current status of treating it is reviewed and recommendations are given, how to determine it, specifically in the case of LC–MS methods. 相似文献
8.
Yuanzhong Yang Reinhard I. BoysenJamil Chowdhury Asif AlamMilton T.W. Hearn 《Analytica chimica acta》2015
In this study, the advantages of carrying out the analysis of peptides and tryptic digests of proteins under gradient elution conditions at pH 6.5 by reversed-phase liquid chromatography (RP-HPLC) and in-line electrospray ionisation mass spectrometry (ESI-MS) are documented. For these RP separations, a double endcapped, bidentate anchored n-octadecyl wide pore silica adsorbent was employed in a capillary column format. Compared to the corresponding analysis of the same peptides and protein tryptic digests using low pH elution conditions for their RP-HPLC separation, this alternative approach provides improved selectivity and more efficient separation of these analytes, thus allowing a more sensitive identification of proteins at different abundance levels, i.e. more tryptic peptides from the same protein could be confidently identified, enabling higher sequence coverage of the protein to be obtained. This approach was further evaluated with very complex tryptic digests derived from a human plasma protein sample using an online two-dimensional (2D) strong cation-exchange (SCX)-RP-HPLC-ESI-MS/MS system. Again, at pH 6.5, with mobile phases of different compositions, improved chromatographic selectivities were obtained, concomitant with more sensitive on-line electrospray ionisation tandem mass spectrometric (ESI-MS/MS) analysis. As a consequence, more plasma proteins could be confidently identified, highlighting the potential of these RP-HPLC methods with elution at pH 6.5 to extend further the scope of proteomic investigations. 相似文献
9.
以固相法合成的三乙四胺钴配合物为研究体系,采用正离子电喷雾串联质谱、紫外-可见吸收光谱、拉曼共振光谱和红外光谱等表征手段,研究了配合物与氧分子的相互作用过程及配合物在吸氧过程中的结构变化。结果表明,三乙四胺钴配合物的吸氧过程是一个动态的变化过程,氧合产物由双氧双桥联的氧合配合物CoⅢL-(O2)2-CoⅢL形式向双羟基桥联的老化配合物CoⅢL-(OH)2-CoⅢL形式转变;18O2同位素标记实验验证了Co-O-O-Co的存在。酸解实验说明OH桥联配合物的形成是造成可逆性差的根本原因。这些结果为探知多胺钴配合物的氧合结构和老化机理提供了新的研究方法和实验依据。 相似文献
10.
Solution or Gas Phase? Oxidation and Radical Formation in Electrospray Ionization Mass Spectrometry (ESI MS) 下载免费PDF全文
The relationship between one‐electron (e?) oxidation processes and the formation of radical cations of endogenous and exogenous compounds in vivo is of considerable interest. This paper reports on the experiments that allow FTICR mass spectrometric (MS) detection of ion signals that are consistent with the formation of radical cations of caffeine (CA) and theophylline (TP) during electrospray ionization (ESI) in ESI FTICR MS and in on‐line electrochemistry (EC)/ESI FTICR MS in positive mode. Significantly, the signals of the radicals of CA?+ and TP?+can be enhanced by simple modifications of the operating conditions in ESI MS, facilitating investigations of radical formation and related reactions. 相似文献