全文获取类型
收费全文 | 155篇 |
免费 | 3篇 |
国内免费 | 6篇 |
专业分类
化学 | 40篇 |
晶体学 | 1篇 |
力学 | 51篇 |
数学 | 41篇 |
物理学 | 31篇 |
出版年
2023年 | 2篇 |
2022年 | 1篇 |
2021年 | 2篇 |
2020年 | 6篇 |
2019年 | 5篇 |
2018年 | 5篇 |
2017年 | 3篇 |
2016年 | 5篇 |
2015年 | 5篇 |
2014年 | 13篇 |
2013年 | 3篇 |
2012年 | 4篇 |
2011年 | 19篇 |
2010年 | 6篇 |
2009年 | 11篇 |
2008年 | 15篇 |
2007年 | 16篇 |
2006年 | 11篇 |
2005年 | 3篇 |
2004年 | 5篇 |
2003年 | 7篇 |
2002年 | 3篇 |
2001年 | 1篇 |
2000年 | 1篇 |
1999年 | 2篇 |
1998年 | 4篇 |
1997年 | 2篇 |
1995年 | 1篇 |
1994年 | 2篇 |
1989年 | 1篇 |
排序方式: 共有164条查询结果,搜索用时 15 毫秒
161.
162.
John M. Zielinski Gerhard Heuberger Ulrich Wiesner Yuanming Zhang 《Journal of Polymer Science.Polymer Physics》1998,36(10):1739-1746
Forced Rayleigh scattering was used to investigate the diffusion of a photoreactive dye molecule in two homogeneous poly(styrene-b-isoprene) (SI) diblock copolymers with overall molecular weights of approximately 2000. Although diffusion rates were intermediate to TTI transport in homopolymer polystyrene (PS) and polyisoprene (PI), system dynamics appear to be largely dictated in each case by the PI block. The size of the polymer jumping unit, on the other hand, is evaluated from a free-volume analysis of the data, and is found to be governed predominantly by the PS component of the copolymer. The mechanism for tracer diffusion in low-molecular-weight block copolymers appears analogous to transport in a high molecular weight SI diblock copolymer (Mn = 13,600) that has been solvated sufficiently in toluene to be microstructurally disordered. © 1998 John Wiley & Sons, Inc. J Polym Sci B: Polym Phys 36: 1739–1746, 1998 相似文献
163.
164.
《印度化学会志》2023,100(9):101060
Monobenzone, a mono benzyl ether of hydroquinone, is used as a topical drug for skin depigmentation. It increases the excretion of melanin from melanocytes. A novel stability-indicating high performance liquid chromatographic approach has been established in the current study to identify related compounds and assay of Monobenzone. The Agilent 1260 system was used for the HPLC analysis, and a gradient method using 0.1% orthophosphoric acid in water and acetonitrile as the eluent was used to separate Monobenzone from known contaminants and degradation products on a Zorbax SB-phenyl (250 mm x 4.6 mm) 5 μm column. The flow rate was set at 0.8 mL/min, the column oven temperature was 30 °C, and the detector wavelength was maintained at 215 nm. The relative retention times for Hydroquinone and Monobenzone dimer were around 0.35 and 1.86 respectively, while the Monobenzone retention time was approximately 10.4 min. The total run time was 30 min. For all known analytes spanning the concentration range from LOQ to 200% of the specification level, the calibration plot revealed a linear relationship (minimum r=0.999). All known analytes' LOD and LOQ were found to be within 0.06–0.10 μg/mL and 0.15–0.24 μg/mL, respectively. A recovery study determined the accuracy of the proposed method. For Hydroquinone and Monobenzone dimer, mean recovery was found to be in the range of 95.86%–99.89% and 93.02%–99.84% respectively. The repeatability study showed that the method is precise enough within acceptable limits. Studies on solution stability and robustness produced results that fell within acceptable bounds. The proposed method shows excellent linearity, accuracy, precision, specificity, robustness, LOD, LOQ and system suitability findings. Additionally, the forced degradation study showed that the approach was stability indicating in nature. 相似文献