Optics and Spectroscopy - The transmission of intrinsic, antimony-doped, and gallium-doped Ge single crystals in the THz spectral range have been experimentally investigated. It is shown that the... 相似文献
Silver-mediated α-dC–Ag+–β-dC hybrid base pairs decorated with 5-iodo- or 5-octadiynyl residues are well accommodated in duplex DNA. A strong Tm increase and favorable thermodynamic data for duplex DNA were observed after addition of silver ions. The phenomenon is particularly obvious when both nucleobases of the base pairs are functionalized. Neither the position of the base pair, nor the type of 5-substituent had a negative influence. On the contrary, functionalization of conventional silver-mediated β-dC–Ag+–β-dC homo base pairs showed a negative impact induced by the bulky substituents. To this end, cytosine modified 12-mer oligodeoxynucleotides were prepared by solid-phase synthesis employing new α-anomeric 2′-deoxycytidine phosphoramidites. A multigram scale synthesis was developed for 5-iodo-α-d -2′-deoxycytidine ( 1 ) employing the direct glycosylation of cytosine with Hoffer's α-d -halogenose followed by separation of anomeric DMT nucleosides. Regarding base-pair stability and functionalization silver-mediated α/β-dC hybrid base pairs were found to be superior to β/β-dC homo pairs. According to their extraordinary properties, they might find applications in DNA diagnostics, material science, or nanotechnology. 相似文献
Droplet evaporation characterization, although of great significance, is still challenging. The recently developed phase rainbow refractometry (PRR) is proposed as an approach to measuring the droplet temperature, size as well as evaporation rate simultaneously, and is applied to a single flowing n-heptane droplet produced by a droplet-on-demand generator. The changes of droplet temperature and evaporation rate after a transient spark heating are reflected in the time-resolved PRR image. Results show that droplet evaporation rate increases with temperature, from ?1.28 m2/s at atmospheric 293 K to a range of (?1.5, ?8) m2/s when heated to (294, 315) K, agreeing well with the Maxwell and Stefan–Fuchs model predictions. Uncertainty analysis suggests that the main source is the indeterminate gradient inside droplet, resulting in an underestimation of droplet temperature and evaporation rate. With the demonstration on simultaneous measurements of droplet refractive index as well as droplet transient and local evaporation rate in this work, PRR is a promising tool to investigate single droplet evaporation in real engine conditions. 相似文献
The diffusive behavior of nanoparticles inside porous materials is attracting a lot of interest in the context of understanding, modeling, and optimization of many technical processes. A very powerful technique for characterizing the diffusive behavior of particles in free media is dynamic light scattering (DLS). The applicability of the method in porous media is considered, however, to be rather difficult due to the presence of multiple sources of scattering. In contrast to most of the previous approaches, the DLS method was applied without ensuring matching refractive indices of solvent and porous matrix in the present study. To test the capabilities of the method, the diffusion of spherical gold nanoparticles within the interconnected, periodic nanopores of inverse opals was analyzed. Despite the complexity of this system, which involves many interfaces and different refractive indices, a clear signal related to the motion of particles inside the porous media was obtained. As expected, the diffusive process inside the porous sample slowed down compared to the particle diffusion in free media. The obtained effective diffusion coefficients were found to be wave vector-dependent. They increased linearly with increasing spatial extension of the probed particle concentration fluctuations. On average, the slowing-down factor measured in this work agrees within combined uncertainties with literature data.
This review summarizes the different tools and concepts that are commonly applied in air quality monitoring. The monitoring of atmosphere is extremely important as the air quality is an important problem for large communities. Main requirements for analytical devices used for monitoring include a long period of autonomic operation and portability. These instruments, however, are often characterized by poor analytical performance. Monitoring networks are the most common tools used for monitoring, so large-scale monitoring programmes are summarized here. Biomonitoring, as a cheap and convenient alternative to traditional sample collection, is becoming more and more popular, although its main drawback is the lack of standard procedures. Telemonitoring is another approach to air monitoring, which offers some interesting opportunities, such as ease of coverage of large or remote areas, constituting a complementary approach to traditional strategies; however, it requires huge costs. 相似文献