首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   118篇
  免费   3篇
化学   117篇
物理学   4篇
  2021年   1篇
  2016年   2篇
  2015年   4篇
  2014年   6篇
  2013年   9篇
  2012年   11篇
  2011年   10篇
  2010年   1篇
  2009年   9篇
  2008年   6篇
  2007年   5篇
  2006年   4篇
  2005年   5篇
  2004年   10篇
  2003年   4篇
  2002年   5篇
  2001年   2篇
  2000年   5篇
  1999年   6篇
  1998年   7篇
  1997年   4篇
  1994年   3篇
  1992年   1篇
  1985年   1篇
排序方式: 共有121条查询结果,搜索用时 34 毫秒
61.
The lack of reliable, certified calibrant solutions for the Fusarium mycotoxins deoxynivalenol (DON), 3-acetyl-DON (3-Ac-DON), 15-acetyl-DON (15-Ac-DON) and nivalenol (NIV) is a serious drawback in the already problematic area of trichothecene analysis. For this reason, purified DON, 3-Ac-DON, 15-Ac-DON and NIV standards were processed, the conditions required for their isolation and purification were optimised, and the crystalline toxins were thoroughly characterised. Several complimentary analytical methods were used to evaluate the identities of the mycotoxins and the types and amounts of impurities; results obtained from 1 H and 13 C NMR spectra, as well as from IR-spectra, were in agreement with the literature. Elemental analysis revealed that the isolated NIV occurs as monohydrate. If this is not known it results in a weighing error of approximately 5%. Differential scanning calorimetry (DSC) was only successful for 15-Ac-DON, as the other trichothecenes decomposed during measurements. No traces of chloride, nitrate and sulphate were found by means of ion chromatography (IC). As expected UV absorption spectra for DON, NIV, 3-Ac-DON and 15-Ac-DON yielded max values of 216, 217, 217 and 219 nm, respectively. Minor peaks due to impurities were observed by high performance liquid chromatography (HPLC) with UV detection. The main impurity peak in the DON sample was identified by LC-tandem mass spectroscopy (LC-MS/MS) as 4,7-dideoxy-NIV (7-deoxy-DON), which occurs at levels of approximately 1.4%. Gas chromatography (GC) was performed, coupled with either an electron capture detector (ECD), a flame ionisation detector (FID), or a mass spectrometric detector (MS); however, derivatisation prior to GC analysis makes the estimation of impurities difficult. LC-MS/MS was found to be unsuitable for quantifying levels of impurities. It can be concluded that high-purity (>97%) B-trichothecene standards were successfully processed and fully characterised for the first time.Dedicated to the memory of Wilhelm Fresenius  相似文献   
62.
A rapid analytical method for sensitive determination of 1,3-dichloro-2-propanol (1,3-DCP) in river water has been developed. 1,3-DCP is extracted from water with ethyl acetate. After filtration through sodium sulfate the ethyl acetate phase is analyzed by gas chromatography–mass spectrometry. The method uses 1,3-DCP-d5 as internal standard. Different extraction solvents, concentrations of ammonium sulfate in the water samples, and the effect of humic acid were tested and their influence on the recovery of DCP has been evaluated. The method quantification limit was 0.1 g L–1. For spiked water samples (0–5.2 g L–1, n=21) a repeatability coefficient of variation of 5.4% was obtained. The average recovery rate of 1,3-DCP was 105±3% (n=21). Stability tests, which were carried out with Danube river water, led to an estimated 1,3-DCP degradation rate of 0.008±0.0008 day–1 at 6°C.  相似文献   
63.
64.
An indirect competitive enzyme linked immunoassay (ELISA) for the detection of the Fusarium mycotoxin deoxynivalenol (DON) in wheat was developed. Instead of the much more common antibody isolation from mammal serum, DON specific antibodies were, for the first time, isolated from the eggs of previously immunized hens. The limit of detection was 2 μg/L for standard curves and spiked wheat extracts. Recoveries for naturally contaminated samples (200–525 μg/kg) were between 80 and 125% compared with GC-ECD data. Concentrations for naturally contaminated samples were chosen with regard to current Austrian guidelines concerning DON levels in produce intended for human consumption, recommending a maximum of 500 μg DON/kg.  相似文献   
65.
66.
67.
Thirteen European laboratories experienced in the analysis of mycotoxins participated in an intercomparison study within a European Commission-funded project. Goals of the study were to check the fitness for purpose of a small batch of gravimetrically prepared calibrants; to compare individually prepared calibrants with common calibrants; to check the feasibility of toxin mixtures as calibrant solutions; and to give recommendations on the production of future certified reference materials (CRMs) with regard to the nature of the calibrant and the means of certification. Each laboratory received ampules of each common calibrant containing single toxins [solution containing either deoxynivalenol (DON), 3-acetyl-DON (3-Ac-DON), nivalenol (NIV), or 15-acetyl-DON (15-Ac-DON)] and 3 ampules of toxin-mixture (solutions of DON + 3-Ac-DON + NIV in acetonitrile) of known concentrations (about 20 microg/mL). Ampules with single toxins (solution containing either DON, 3-Ac-DON, NIV, or 15-Ac-DON) and a toxin-mixture (solutions of DON + 3-Ac-DON + NIV in acetonitrile) of unknown concentrations were distributed to the participants for quantification. The participating laboratories used mainly high-performance liquid chromatography (HPLC)-diode array detection UV for DON, 3-Ac-DON, NIV, and 15-Ac-DON; gas chromatography-electron capture detection (GC-ECD) and GC-mass spectrometry methods were used sparingly. Linear calibration curves were achieved by >90% of the participants. Relative between-day variation (RSDr) of 26% of the laboratories was greater than the target value of 5% for HPLC, and RSDr of 32% of the laboratories was greater than the desired value of 10% for GC. Relative between-laboratory variation (RSDR) of the GC results obtained with single common calibrants was greater than the target value of 16% for all laboratories. RSDR of the HPLC results for the common unknown single toxin solutions was less than the target value of 8% except for 15-Ac-DON. Generally, better recoveries were observed from common calibrants (102% for mix calibrants and 98% for single calibrants) than from individually prepared calibrants (95%). This international comparison study clearly showed the high scattering of results in the analysis of type-B trichothecenes, particularly when GC was used. Obviously, this intercomparison study was not suited for the certification of B-trichothecenes. A certification of the proposed calibrant material was therefore recommended on the basis of its gravimetrical preparation.  相似文献   
68.
The study of changes of nutritional value of fruit during the ripening process can help estimate the optimal date for fruit harvesting to achieve the best quality for direct consumption and further utilization. The aim of this study was to monitor the changes of chemical composition of medlar fruit (Mespilus germanica L.) measured at five various ripening stages including 134, 144, 154, 164 and 174 days after full bloom (DAFB). Fruits were analyzed and ascorbic acid (AA) and total phenolic compound content with respect to the total antioxidant activity were determined. In addition, selected micronutrients and macronutrients were monitored. The results of our experiments demonstrate that ascorbic acid, total phenolic compound content and total antioxidant activity decreased significantly with increasing time of ripeness. The decreasing tendency in potassium, calcium and magnesium contents during the ripening stages was also determined. During the ripening period, the content of all micronutrients as well as phosphorus and sodium was balanced, with no statistically significant differences between the monitored ripening stages, which can be considered as a positive fact with respect to ideal consumption quality of fruit.  相似文献   
69.
A rapid fluorescence polarization (FP) immunoassay has been developed for the simultaneous determination of T-2 and HT-2 toxins in naturally contaminated wheat samples. Syntheses of four fluorescein-labelled T-2 or HT-2 toxin tracers were carried out and their binding response with seven monoclonal antibodies was evaluated. The most sensitive antibody-tracer combination was obtained by using an HT-2-specific antibody and a fluorescein-HT-2 tracer. The developed competitive FP immunoassay in solution showed high cross-reactivity for T-2 toxin (CR% = 100%) while a very low CR% for neosolaniol (0.12%) and no cross-reactivity with other mycotoxins frequently occurring in wheat. A rapid extraction procedure using 90% methanol was applied to wheat samples prior to FP immunoassay. The average recovery from spiked wheat samples (50 to 200 μg kg−1) was 96% with relative standard deviation generally lower than 8%. A limit of detection of 8 μg kg−1 for the combined toxins was determined. Comparative analyses of 45 naturally contaminated and spiked wheat samples by both the FP immunoassay and high-performance liquid chromatography/immunoaffinity clean-up showed a good correlation (r = 0.964). These results, combined with the rapidity (10 min) and simplicity of the assay, show that this method is suitable for high throughput screening as well as for quantitative determination of T-2 and HT-2 toxins in wheat.  相似文献   
70.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号