首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   118篇
  免费   3篇
化学   117篇
物理学   4篇
  2021年   1篇
  2016年   2篇
  2015年   4篇
  2014年   6篇
  2013年   9篇
  2012年   11篇
  2011年   10篇
  2010年   1篇
  2009年   9篇
  2008年   6篇
  2007年   5篇
  2006年   4篇
  2005年   5篇
  2004年   10篇
  2003年   4篇
  2002年   5篇
  2001年   2篇
  2000年   5篇
  1999年   6篇
  1998年   7篇
  1997年   4篇
  1994年   3篇
  1992年   1篇
  1985年   1篇
排序方式: 共有121条查询结果,搜索用时 812 毫秒
101.
102.
103.
Commercially available solid zearalenone (ZON) to be used as a certified liquid calibrant (BCR-699) in a project funded by the European Commission within the Standard Measurement and Testing program was characterized and its purity determined. The degree of purity of the ZON was examined by UV spectrophotometer, liquid chromatography (LC) with diode array and fluorescence detection, 1H and 13C-NMR spectrometry, LC-mass spectrometry (LC/MS/MS), ion chromatography (IC), and differential scanning calorimetry (DSC). The diagrams obtained from DSC analysis and the UV spectrum showed no detectable impurities. Likewise, no impurities were observed by LC analysis with both diode array and fluorescence detection. IC determination revealed negligible contamination of ZON with chloride of 0.020 +/- 0.005% and nitrate of 0.016 +/- 0.006%. Zearalanone (ZAN) was identified as one of 2 minor (0.2%) impurities by LC/MS/MS. The 1H-NMR measurements revealed an additional peak, which has not been previously reported in the literature. It could be identified as part of the ZON spectrum as the signal arising from the phenolic proton attached to C4'. The manufacturer states an additional contamination with 0.2% methylene chloride, which could be confirmed to an extent of 0.1% by 1H-NMR. Minor impurities, whose structures remain unknown, were discovered at 3.5 and < 1 ppm. Total percentage of impurities based on NMR measurement was estimated not to exceed 1%. A purity of 99.5% with a tolerance of +/- 0.5% was finally attributed to the ZON studied in this project.  相似文献   
104.
The state-of-the-art in the analysis of estrogenic mycotoxins in cereals   总被引:1,自引:0,他引:1  
The increasing public awareness of chemicals that mimic or otherwise interfere with the activity of natural hormones - so-called endocrine disrupters - has also led to greater study of mycotoxins with estrogenic potential. The purpose of this paper is to introduce the topic of estrogenic mycotoxins and to discuss the state-of-the-art in the analysis of these substances in cereals, with special emphasis on zearalenone (ZON) as its most relevant representative. Because the use of immunoaffinity columns (IAC) followed by high-performance liquid chromatography with fluorescence detection (HPLC-FLD) and immunoassays are currently the most frequently used methods for the determination of ZON and its metabolites, these techniques are discussed in more detail. Recent papers, which have revealed the great potential of HPLC-MS(MS) for the simultaneous detection and identification of several estrogenic mycotoxins, are discussed. The performances of the state-of-the-art methods are finally compared by study of the results obtained in recent international intercomparison studies. On the one hand, these studies revealed the good performance of both chromatographic and antibody-based methods. On the other hand, the need for better means of external quality assurance measures, especially the availability of certified reference materials and certified standards, has clearly been demonstrated.  相似文献   
105.
 A simulation and optimization software program (Pro ezGC? by Analytical Innovations, Inc., Kettering, OH, USA) for GC temperature programs was applied to the analysis of organochlorine pesticides in sediments. By means of this software, the run time of a conventional temperature program derived from trial and error experiments could be reduced to less than a third, achieving at the same time an increased separation efficiency. Finally, 17 organochlorine pesticides could be baseline-resolved on a capillary column in less than 12 min. In addition, a two-fold sensitivity enhancement was achieved. Received: 31 January 1997/Accepted: 10 April 1997  相似文献   
106.
Deoxynivalenol (DON) obtained from 2 commercial sources was characterized, and its purity was determined. The structural identity of DON was confirmed by 1H and 13C-nuclear magnetic resonance (NMR) spectroscopy, gas chromatography with mass spectrometric (GC/MS) detection, and infrared/attenuated total reflectance (IR/ATR) spectroscopy. NMR spectra showed shifts that varied from previously published data. However, we established a complete, unambiguous assignment for all signals. Chromatograms obtained by GC/MS were almost identical for both investigated samples and confirmed the structure of DON. Likewise, IR/ATR spectra verified the identity of DON. The degree of purity was determined by liquid chromatography (LC) with a variable wavelength detector, LC/MS/MS, GC with electron-capture detection (GC-ECD), and ultraviolet (UV) spectrophotometry. The purity check using LC showed a single peak in both chromatograms. With LC/MS/MS measurements, we could detect small amounts of impurities in the crystalline DON from both sources. In data obtained by GC-ECD, no differences in purity were observed. The UV measurements showed an absorption maximum at 217 nm. The mean epsilon(m) of the extinction coefficients was calculated as 6727 (L/cm/mol) for DON (Sigma) and 6825 (L/cm/mol) for DON (Biopure). Finally, the purity of DON from the 2 commercial sources was calculated as >96 and >98%, respectively. Although the DON produced by both providers can be considered sufficiently pure for routine analysis of trichothecenes in food and feed, this work again demonstrated that the impurity of the solid mycotoxin constitutes the greatest contribution to the overall uncertainty of a mycotoxin calibrant.  相似文献   
107.
An indirect competitive enzyme linked immunoassay (ELISA) for the detection of the Fusarium mycotoxin deoxynivalenol (DON) in wheat was developed. Instead of the much more common antibody isolation from mammal serum, DON specific antibodies were, for the first time, isolated from the eggs of previously immunized hens. The limit of detection was 2 microg/L for standard curves and spiked wheat extracts. Recoveries for naturally contaminated samples (200-525 microg/kg) were between 80 and 125% compared with GC-ECD data. Concentrations for naturally contaminated samples were chosen with regard to current Austrian guidelines concerning DON levels in produce intended for human consumption, recommending a maximum of 500 microg DON/kg.  相似文献   
108.
This is the first publication which describes the evaluation of the analytical performance and state-of-the-art of the determination of methyl tert-butyl ether (MTBE) in water at ng L–1 concentrations. An interlaboratory comparison study for the determination of MTBE in water was carried out. Twenty-eight laboratories from seven European countries participated in the study. Twenty of those finally transmitted results to the organiser. Italian spring water, containing no detectable amounts of MTBE was fortified to yield two samples with MTBE concentrations of 0.074±0.004 µg L–1 and 0.256±0.010 µg L–1. The laboratories applied their regular in-house methods to analyse the water samples. Static headspace, Purge & Trap, solid-phase microextraction (SPME) or direct aqueous injection were used as sample preparation techniques. Subsequent separation and detection of MTBE were performed by gas chromatography/mass spectrometry (GC/MS) or gas chromatography/flame ionisation detection (GC/FID). After rejection of outliers, the overall arithmetic mean of laboratory results corresponded to recoveries of 78±20% (Sample A) and 88±20% (Sample B) of the reference concentrations. The between laboratory coefficients of variation (CV) were 32% and 31%, respectively. The organisation of the study and quality assurance measures at the organiser's laboratory are described. Moreover, the measurement results of the participants and the analytical methods used for the determination of MTBE are presented and the correlation between selected method parameters and data quality is discussed.  相似文献   
109.
110.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号