首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 218 毫秒
1.
An electrospray ionization tandem mass spectrometry (ESI-MS/MS) system with an online dual-loop cleanup device was developed for simultaneous quantitation of the urinary benzene exposure biomarkers trans,trans-muconic acid (ttMA) and S-phenylmercapturic acid (SPMA). The cleanup device was constructed from an autosampler, two electrically operated two-position switching valves, a reversed-phase C18 trap cartridge, a 200-microL loop, and two solvent-delivery pumps. The device was interfaced directly with a triple-quadrupole mass spectrometer and fully controlled by computer software and hardware. Because isotope dilution by introducing 13C-labeled ttMA and SPMA as internal standards was employed, the precision of the analytical system was high (for ttMA, intra- and inter-day CV values ranged from 3.82-4.53%; for SPMA, 2.13-7.06%). The calibration curves obtained using human urine spiked with ttMA were linear from 15.6-4000 microg/L (R = 0.9998) and SPMA at concentrations from 0.78-200 microg/L (R = 0.9993). The method detection limit (MDL) for SPMA was 0.23 microg/L. The MDL of ttMA could not be determined accurately because of unavailability of an appropriate blank urine matrix, but was estimated to be lower than 7.43 microg/L. Without tedious manual sample cleanup procedures the analytical system is fully automated and is therefore useful for high-throughput simultaneous determination of urinary ttMA and SPMA. The sample throughput is roughly 100 samples per day. With the selectivity and the sensitivity provided by MS/MS detection, the analytical system can be used for large-scale monitoring of environmental or occupational exposure of humans to benzene.  相似文献   

2.
The aim of this study is to validate isotope-dilution electrospray ionization tandem mass spectrometry (ESI-MS-MS) method with a dual-loop cleanup device for simultaneous quantitation of two benzene metabolites, trans, trans-muconic acid (ttMA) and S-phenylmercapturic acid (SPMA), in human urine. In this study, a pooled blank urine matrix from rural residents was adopted for validation of the analytical method. The calibration curve, detection limit, recovery, precision, accuracy and the stability of sample storage for the system have been characterized. Calibration plots of ttMA and SPMA standards spiked into two kinds of urine matrixes over a wide concentration range, 1/32-8-fold biological exposure indices (BEIs) values, showed good linearity (R > 0.9992). The detection limits in pooled urine matrix for ttMA and SPMA were 1.27 and 0.042 μg g−1 creatinine, respectively. For both of ttMA and SPMA, the intra- and inter-day precision values were considered acceptable well below 25% at the various spiked concentrations. The intra- and inter-day apparent recovery values were also considered acceptable (apparent recovery >90%). The ttMA accuracy was estimated by urinary standard reference material (SRM). The accuracy reported in terms of relative error (RE) was 5.0 ± 2.0% (n = 3). The stability of sample storage at 4 or −20 °C were assessed. Urinary ttMA and SPMA were found to be stable for at least 8 weeks when stored at 4 or −20 °C. In addition, urine samples from different benzene exposure groups were collected and measured in this system. Without tedious manual sample preparation procedure, the analytical system was able to quantify simultaneously ttMA and SPMA in less than 20 min.  相似文献   

3.
The potential of liquid chromatography combined with tandem mass spectrometry (LC/MS/MS) for the determination of pesticide metabolites in human urine at the sub-ppb level is explored. Metabolites from two organophosphorous pesticides, 4-nitrophenol (from parathion and parathion-methyl) and 3-methyl-4-nitrophenol (from fenitrothion), are taken as model analytes to conduct this study. After direct injection of the urine sample (10 microL), different approaches were evaluated in order to achieve correct quantitation of analytes using an electrospray ionisation (ESI) interface. Thus, the feasibility of using external calibration was checked versus the use of different isotope-labeled internal standards. The advantages of applying coupled-column liquid chromatography (LC/LC) as an efficient clean-up without any type of sample manipulation are also discussed. The combination of LC/LC with ESI-MS/MS allows the direct analysis of free metabolites in urine, as the automated clean-up performed by the coupled-column technique is sufficient for the removal of interferences that suppress the ionisation of analytes in the ESI source. Using this procedure with external calibration, good precision and recoveries, and detection limits below 1 ng/mL are reached with analysis run times of around 8 min. The hyphenated technique LC/LC/ESI-MS/MS is proved to be a powerful analytical tool, allowing the rapid, sensitive and selective determination of 4-nitrophenol and 3-methyl-4-nitrophenol in human urine without any sample treatment.  相似文献   

4.
S-phenylmercapturic acid is widely accepted as a specific biomarker for the evaluation of benzene exposure. Here, we describe a fast, specific and sensitive high-performance liquid achromatography coupled with tandem mass spectrometry (LC-MS/MS) method that has been developed and validated for the determination of S-phenylmercapturic acid in human urine. Isotope-labeled S-phenylmercapturic acid-d5 was used as internal standard to improve the method ruggedness. The fully automated solid-phase extraction method on a 96-well Oasis MAX (mix-mode anion exchange) plate was employed to clean up the urine samples before analysis. The rapid LC-MS/MS analysis of extracted samples was achieved on a Genesis C18 column with a run time of only 3 min. Negative electrospray ionization with multiple reaction monitoring (ESI-MRM) mode was used to detect S-phenylmercapturic acid (m/z 238 --> 109) and S-phenylmercapturic acid -d5 (m/z 243 --> 114). The method fulfils all the standard requirements of method validation. The calibration curve was linear within the concentration range 0.400-200 ng/mL. The method performed accurately and precisely in validation with <7.5% relative error and <6.5% relative standard deviation of quality control samples. The method efficacy was also verified by the analysis of urine samples from 12 smokers and 12 non-smokers. With the fully automated sample cleanup procedure and the fast LC-MS/MS analysis, a sample analysis throughput of 384 samples per day could be achieved.  相似文献   

5.
Anabolic androgenic steroids (AAS) are metabolized extensively in the human body, resulting mainly in the formation of glucuronide conjugates. Current detection methods for AAS are based on gas chromatographic/mass spectrometric (GC/MS) analysis of the hydrolyzed steroid aglycones. These analyses require laborious sample preparation steps and are therefore time consuming. Our interest was to develop a rapid and straightforward method for intact steroid glucuronides in biological samples, using liquid-phase microextraction (LPME) sample clean-up and concentration method combined with liquid chromatographic/tandem mass spectrometric (LC/MS/MS) analysis. The applicability of LPME was optimized for 13 steroid glucuronides, and compared with conventional liquid-liquid extraction (LLE) and solid-phase extraction (SPE) procedures. An LC/MS/MS method was developed for the quantitative detection of AAS glucuronides, using a deuterium-labeled steroid glucuronide as the internal standard. LPME, owing to its high specificity, was shown to be better suited than conventional LLE and SPE for the clean-up of urinary AAS glucuronides. The LPME/LC/MS/MS method was fast and reliable, offering acceptable reproducibility and linearity with detection limits in the range 2-20 ng ml(-1) for most of the selected AAS glucuronides. The method was successfully applied to in vitro metabolic studies, and also tested with an authentic forensic urine sample. For a urine matrix the method still has some unsolved problems with specificity, which should be overcome before the method can be reliably used for doping analysis, but still offering additional and complementary data for current GC/MS analyses.  相似文献   

6.
Acrylamide has been reported to be present in high-temperature processed foods and normal processed food intake could lead to significant acrylamide exposure. Acrylamide in vivo can be conjugated with glutathione in the presence of glutathione transferase. This conjugation product is further metabolized and excreted as N-acetyl-S-(propionamide)cysteine (NASPC) in the urine. NASPC could be considered a biomarker for acrylamide exposure. The objective of this study was to develop a highly specific, rapid and sensitive method to quantify urinary NASPC, serving as a biomarker for acrylamide exposure assessment. Isotope-labeled [13C3]NASPC was successfully synthesized and used as an internal standard. This urine mixture was directly analyzed using a newly developed liquid chromatographic/tandem mass spectrometric method coupled with an on-line clean-up system. The detection limit for this method was estimated as < 5 microg l(-1)(0.4 pmol) on-column. The method was applied to measure the urinary level of NASPC in 70 apparently health subjects. The results showed that the NASPC urinary level was highly associated with smoking. Smokers had a significantly higher urinary NASPC level (135 +/- 88 microg g(-1) creatinine) than non-smokers (76 +/- 30 microg g(-1) creatinine). A highly sensitive and selective LC/MS/MS isotope dilution method was successfully established. With an on-line clean-up system, this system is capable of routine high-throughput analysis and accurate quantitation of NASPC in urine. This could be a useful tool for health surveillance for acrylamide exposure in a population for future study.  相似文献   

7.
The patterns and levels of urinary excreted ribonucleosides which reflect RNA turnover and metabolism in humans offer the potential for early detection of disease and monitoring of therapeutic intervention. A liquid chromatography/tandem mass spectrometry (LC/MS/MS) method employing constant neutral loss (CNL) scanning for the loss of the ribose moiety (132 u) was used to detect ribonucleosides in human urine and to evaluate this analytical platform for biomarker research in clinical trials. Ribonucleosides were stable and not influenced by the time spent at room temperature prior to freezing or long-term storage at -80 °C. Matrix effects caused variation in the mass spectrometer response which was dependent on the concentration of the analysed urine sample. For the use of urinary ribonucleoside profiling in clinical biomarker studies, adjustment of the urine samples to a common concentration prior to sample preparation is therefore advocated. Changes in the mass spectrometer response should be accounted for by the use of an internal standard added after sample preparation. Diurnal variation exceeded inter-day variation of an individual's ribonucleoside profile, but inter-person differences were predominant and allowed the separation of individuals against each other in a multivariate space. Due to considerable diurnal variation the use of spot urine samples would introduce unnecessary variation and should be replaced by the collection of multiple spot urine samples across the day, where possible. Should such a protocol not be feasible, biological intra-day and inter-day variation must be considered and accounted for in the data interpretation.  相似文献   

8.
A new automated, high-throughput method for the determination of ochratoxin A (OTA) in human urine samples has been optimized and validated using solid-phase microextraction coupled to liquid chromatography-tandem mass spectrometry (SPME-LC-MS/MS). High-throughput was achieved by simultaneous preparation of up to 96 samples using multi-fiber SPME device and multi-well plates. A carbon-tape coating was chosen for the first time as the best extracting phase for this contaminant. The proposed method required only minimal sample pre-treatment to adjust sample pH to 3.0 using a dilution (1:1) with 0.5M phosphate-buffered saline. A simple gradient guaranteed a good chromatographic separation from matrix interferences in only 8min. Relative recovery (%), precision and linearity validation results met Food and Drug Administration acceptance criteria at three concentration levels (1, 10, and 50ng/mL), indicating excellent performance of the proposed method. Limits of detection and quantitation were 0.3 and 0.7ng/mL in urine, respectively. OTA determination in urine is a good marker for human exposure to this mycotoxin. It is also less invasive than blood analysis. This method is fully automated and the SPME technique is simpler, less time-consuming and cheaper compared with most widely adopted clean-up procedures for OTA extraction from urine.  相似文献   

9.
8-Hydroxy-2'-deoxyguanosine (8OHdG), one of the major oxidative DNA lesions induced by radical agents, is commonly used as a biomarker for oxidative stress, nowadays preferably in urine. In the absence of a commercially available internal standard a micro-high-performance liquid chromatography/electrospray ionization tandem mass spectrometry (micro-HPLC/ESI-MS/MS) method, suitable for routine analysis of 8OHdG in human urine using external calibration, was developed. Evaluation of the matrix effect showed that the method allows highly sensitive and accurate quantitation despite the absence of an internal standard. HPLC analysis was performed using gradient elution at a flow rate of 10 microL min(-1) using a capillary reversed-phase column and an injection volume of 0.5 microL, with detection of 8OHdG in positive multiple reaction monitoring (MRM) mode. The absolute limit of detection was 0.35 fmol using m/z 168 as a quantifier (fragment) ion. A linear (R2> 0.999) calibration curve in urine was obtained over a range 0.2-10 ng mL(-1). This method is about 20 times more sensitive than previously described procedures, and is characterized by high accuracy (mean 90%) and good reproducibility (RSD <10%). The optimized method was applied to determination of 8OHdG in 18 urinary samples derived from three healthy volunteers. 8OHdG urinary excretion ranged from 3.0-7.9 microg/day, and a large intra-individual variation was found. This method, which effectively circumvents the need for isotopically labeled 8OHdG (internal standard), is suitable for routine monitoring of exposure to DNA-damaging factors in a large number of subjects.  相似文献   

10.
This article presents an analytical approach that used chemical derivatization to enhance mass spectrometric (MS) response in electrospray ionization (ESI) mode of 1-hydroxypyrene (1-OHP), a commonly used biomarker to monitor human exposure to polycyclic aromatic hydrocarbons (PAHs). The enhancement successfully enabled the desired detection of 50 pg/mL in human urine. The introduction of an MS-friendly dansyl group to 1-OHP enhanced both ionization efficiency in the ESI source and collision-activated dissociation (CAD) in the collision cell. The response increase was estimated to be at least 200-fold, and enabled the reduction of sample size to only 100 microL. The selective MS detection also facilitated a fast (run time 3 min) liquid chromatography (LC) method which successfully resolved the analyte and interferences. The sample processing procedure included enzymatic hydrolysis of glucuronide and sulfate conjugates, liquid-liquid extraction, derivatization with dansyl chloride and a final liquid-liquid extraction to generate clean extracts for LC/MS/MS analysis. This approach has been validated as sensitive, linear (50-1000 pg/mL), accurate and precise for the quantitation of 1-OHP in human urine. This is the first report of using chemical derivatization to enhance MS/MS detection with fast chromatography in the determination of 1-OHP in human urine.  相似文献   

11.
An automated high-performance liquid chromatographic assay for the determination of an aldosterone antagonist (I) is described using column switching for direct injection of urine samples. After dilution with buffered internal standard solution, the sample was injected onto a clean-up column (17 X 4.6 mm I.D.), dry-packed with C18 reversed-phase material (particle size 30 micron). Polar urine components were removed by flushing the clean-up column with water. Retained substances, including I and the internal standard, were desorbed by backflush elution onto a 5-micron ODS-silica analytical column (125 X 4 mm I.D.), separated with water-methanol-tetrahydrofuran, and detected at 295 nm. After backflushing the analytical column and re-equilibrating the clean-up column, the system was ready for the next injection. The limit of quantification was ca. 100 ng/ml, using a 100-microliter specimen of diluted urine. The mean inter-assay precision of the method up to 25.6 micrograms/ml was 2%. Practicability and accuracy of the new method were demonstrated by the application to excretion studies performed with human volunteers.  相似文献   

12.
Analysis of urinary N7-(benzo[a]pyren-6-yl)guanine (BP-6-N7Gua), a DNA adduct induced by benzo[a]pyrene, may serve as a risk-associated biomarker for exposure to polyaromatic hydrocarbons (PAHs). In this study a highly sensitive and specific analytical method, incorporating on-line sample preparation coupled with isotope-dilution liquid chromatography and tandem mass spectrometry (LC/MS/MS), was developed to quantitate this adduct in human urine. In order to achieve accurate quantitation, 15N5-labeled BP-6-N7Gua was synthesized to serve as the internal standard, and a two-step solid-phase extraction (SPE) procedure using C8 and SCX cartridges was used for sample cleanup. BP-6-7-N7Gua was analyzed using positive ion LC/MS/MS operated in multiple reaction monitoring (MRM) mode. The [M+H]+ ions at m/z 402 and 407 and the common fragment ion of [M+H]+ at m/z 252 were monitored for quantification. The recovery of this analyte after two-step SPE was 90%, and the limit of detection was 2.5 fmol/mL in 10 mL of urine. This highly specific and sensitive method for BP-6-N7Gua in urine may be applied to assess exposure to PAHs in coke-oven workers for future molecular epidemiology studies on health effects of PAHs.  相似文献   

13.
For the detection of anabolic steroid residues in bovine urine, a highly sensitive liquid chromatographic/electrospray ionization tandem mass spectrometric (LC/ESI-MS/MS) method was developed using both positive and negative ionization. For four compounds the ESI mode was not sensitive enough and gas chromatographic/mass spectrometric GC/MS detection was therefore still necessary as a complementary method. The sample clean-up consisted of solid-phase extraction (SPE) on a C(18) column followed by enzymatic hydrolysis and a second solid-phase extraction on a combination of a C(18) and a NH(2) column. After this last SPE clean-up, the eluate was split into two equal aliquots. One aliquot was further purified and after derivatization used for GC/MS analysis. The other aliquot was analyzed with LC/MS/MS in both ESI+ and ESI- modes. The method was validated according to the European Commission Decision 2002/657/EC. Decision limits (CCalpha) were between 0.16 and 1 ng ml(-1) for the compounds detected with the LC/MS/MS method. The developed method is used in routine analysis in our laboratory.  相似文献   

14.
A high-performance liquid chromatography-tandem mass spectrometric (HPLC-MS-MS) method is presented and evaluated for the determination of S-benzylmercapturic acid (S-BMA) and S-phenylmercapturic acid (S-PMA) in human urine. Both of these compounds are important for occupational health owing to their use as biomarkers of exposure to toluene and benzene, respectively. Toluene is used extensively as a solvent, and the health hazards of benzene have been well established. The optimized urine sample preparation scheme consists of solid-phase extraction (SPE) followed by an acetone wash. The chromatographic analysis consists of a reversed-phase gradient system, which uses electrospray ionization in negative-ion mode with a triple-quadrupole mass spectrometric detector. Accuracy and precision of this method are demonstrated by a series of recovery studies of spiked human urine and synthetic urine substitute. Spike levels at 1, 2, 6, 8, and 30 ng/mL for both analytes demonstrate average recoveries (accuracy) ranging from 99 to 110%. Precision as measured by the relative standard deviation (%RSD) of multiple samples (n=9) at each concentration level was 5.3% or less for both analytes in urine. The limit of detection (LOD) is approximately 0.2 ng/mL for S-BMA and S-PMA. This data, other figures of merit and other factors, such as ion suppression of the electrospray ionization source, are discussed.  相似文献   

15.
The aim of this work was to develop a method for the characterization and determination of diuretics in human urine samples by liquid chromatography (LC) coupled to pneumatically assisted electrospray ionization (ES) mass spectrometry (MS). The diuretics studied were substances forbidden by the IOC such as trichlormethiazide, furosemide, canrenoic acid, benzthiazide, bendroflumethiazide, bumetanide, etacrynic acid and spironolactone. For this purpose, the operational parameters of electrospray, such as counter electrode voltage, capillary voltage, sample cone voltage and source temperature, were optimized in order to obtain the best signal stability and the highest sensitivity for the greatest number of diuretic agents. The optimized separation method was successfully coupled with the MS system to analyze the above-mentioned diuretics extracted from spiked urine samples by a liquid extraction and clean-up procedure at basic pH, using ethyl acetate as solvent and the salting-out effect (NaCl). The mass spectra obtained provide adequate information for identification purposes. Positive urine samples obtained from athletes were also analyzed. The presence of these substances in human urine was confirmed by this method, making LC/ES-MS an analytical tool to be considered in the area of antidoping control.  相似文献   

16.
Electrospray ionization (ESI) mass spectra of 19 common beta(2)-agonists were investigated in terms of fragmentation pattern and dissociation behavior of the analytes, proving the origin of fragment ions and indicating mechanisms of charge-driven and charge-remote fragmentation. Based on these data, liquid chromatographic/ESI tandem mass spectrometric (LC/ESI-MS/MS) screening and confirmation methods were developed for doping control purposes. These procedures employ established sample preparation steps including either acidic or enzymatic hydrolysis, alkaline extraction and, in the case of equine urine specimens, acidic re-extraction of the analytes. In addition, a degradation product of formoterol caused by acidic hydrolysis during sample preparation could be identified and utilized as target compound in screening and also confirmation methods. The screening procedures cover 18 or 19beta(2)-agonists, the estimated limits of detection of which for equine and human urine samples vary between 2 and 100 ng ml(-1) and between 2 and 50 ng ml(-1), respectively. A single LC/MS/MS analysis can be performed in 9 min.  相似文献   

17.
A new liquid chromatography/atmospheric pressure chemical ionization-tandem mass spectrometry (LC/APCI-MS/MS) method with on-line sample clean-up for the determination of telmisartan in human blood plasma is presented. This technique is compared to a previously introduced enzyme-linked immunosorbent assay (ELISA), where fluorescence is used as detection method. For the LC/MS method applying an internal calibration via a deuterated internal standard, the limit of detection was 0.3 ng/mL, the limit of quantification was 0.9 ng/mL and the linear range extended from 0.9 to 1000 ng/mL. Forty-eight plasma samples from four healthy volunteers were analyzed in a pharmacokinetic study to obtain data for the method comparison. As a result, these two new and independent analytical methods for the determination of telmisartan in human blood plasma proved to yield comparable results for the amount of analyte.  相似文献   

18.
Serena P  Tapparo A  Bombi GG 《The Analyst》2000,125(4):689-692
The accurate determination of E,E-2,4-hexadiendioic acid (t,t-muconic acid), an important urinary biomarker of benzene exposure, is directly performed in human urine by a new two-dimensional liquid chromatographic method. After a first partial separation of urine components by a reversed-phase mechanism and the focalisation of the anionic analytes on a small anion-chromatographic column, a conventional ion-chromatographic analysis with UV detection is carried out. The analytical procedure is fully controlled by the HPLC instrumentation software using an eight-port switch valve. If compared with conventional one-dimensional procedures, the new method produces chromatograms containing a limited number of well resolved peaks and consequently allows better analytical performances: no interfering peaks, absence of bias, repeatability better than 5% in the concentration range 0.09-5 mg dm-3 and a detection limit of 4.0 micrograms dm-3 (alpha = beta = 0.05) for the analysis of real samples.  相似文献   

19.
Chuang JC  Emon JM  Durnford J  Thomas K 《Talanta》2005,67(3):658-666
An enzyme-linked immunosorbent assay (ELISA) method was developed to quantitatively measure 2,4-dichlorophenoxyacetic acid (2,4-D) in human urine. Samples were diluted (1:5) with phosphate-buffered saline containing 0.05% Tween and 0.02% sodium azide, with analysis by a 96-microwell plate immunoassay format. No clean up was required as dilution step minimized sample interferences. Fifty urine samples were received without identifiers from a subset of pesticide applicators and their spouses in an EPA pesticide exposure study (PES) and analyzed by the ELISA method and a conventional gas chromatography/mass spectrometry (GC/MS) procedure. For the GC/MS analysis, urine samples were extracted with acidic dichloromethane (DCM); methylated by diazomethane and fractionated by a Florisil solid phase extraction (SPE) column prior to GC/MS detection. The percent relative standard deviation (%R.S.D.) of the 96-microwell plate triplicate assays ranged from 1.2 to 22% for the urine samples. Day-to-day variation of the assay results was within ±20%. Quantitative recoveries (>70%) of 2,4-D were obtained for the spiked urine samples by the ELISA method. Quantitative recoveries (>80%) of 2,4-D were also obtained for these samples by the GC/MS procedure. The overall method precision of these samples was within ±20% for both the ELISA and GC/MS methods. The estimated quantification limit for 2,4-D in urine was 30 ng/mL by ELISA and 0.2 ng/mL by GC/MS. A higher quantification limit for the ELISA method is partly due to the requirement of a 1:5 dilution to remove the urine sample matrix effect. The GC/MS method can accommodate a 10:1 concentration factor (10 mL of urine converted into 1 mL organic solvent for analysis) but requires extraction, methylation and clean up on a solid phase column. The immunoassay and GC/MS data were highly correlated, with a correlation coefficient of 0.94 and a slope of 1.00. Favorable results between the two methods were achieved despite the vast differences in sample preparation. Results indicated that the ELISA method could be used as a high throughput, quantitative monitoring tool for human urine samples to identify individuals with exposure to 2,4-D above the typical background levels.  相似文献   

20.
A novel high-performance liquid chromatography tandem mass spectrometry (LC/MS/MS) method is described for the determination of vancomycin in serum and urine. After the addition of internal standard (teicoplanin), serum and urine samples were directly injected onto an HPLC system consisting of an extraction column and dual analytical columns. The columns are plumbed through two switching valves. A six-port valve directs extraction column effluent either to waste or to an analytical column. A ten-port valve simultaneously permits equilibration of one analytical column while the other is used for sample analysis. Thus, off-line analytical column equilibration time does not require mass spectrometer time, freeing the detector for increased sample throughput. The on-line sample extraction step takes 15 seconds followed by gradient chromatography taking another 90 seconds. Having minimal sample pretreatment the method is both simple and fast. This system has been used to successfully develop a validated positive-ion electrospray bioanalytical method for the quantitation of vancomycin. Detection of vancomycin was accurate and precise, with a limit of detection of 1 ng/mL in serum and urine. The calibration curves for vancomycin in rat, dog and primate were linear in a concentration range of 0.001-10 microg/mL for serum and urine. This method has been successfully applied to determine the concentration of vancomycin in rat, dog and primate serum and urine samples from pharmacokinetic and urinary excretion studies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号