首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 156 毫秒
1.
The measurement of the gas permeability coefficient as a function of the mean pressure across a membrane can be used to determine a mean pore radius of the membrane. This method has been applied by several authors to characterize microporous and asymmetric ultrafiltration or hyperfiltration membranes. This paper shows how the data acquisition and handling are improved. Experiments are performed on microporous Millipore membranes with a nominal pore radius of 50 nm and on ultrafiltration merebranes of poly(2,6-dimethyl-1,4-phenyleneoxide) with an expectedly sharp pore-size distribution around 2 nm. For the Millipore membrane an unexpected dependence of the calculated pore radius on the type of gas used in the experiment has been found. Measurements on the ultrafiltration membranes indicate that the viscous flow contribution to the permeability coefficient cannot be determined with sufficient accuracy. It is concluded that application of the gas permeation method has some limitations which were not previously recognized.  相似文献   

2.
Dense membranes of Hyflon AD 60X were prepared by the solvent evaporation method and by melt pressing. The diffusion coefficient, solubility and permeability of the membranes were measured for six permanent gases using time lag and steady state permeation measurements. The thermal properties were determined by Differential Scanning Calorimetry (DSC) and the solvent content was measured gravimetrically and was estimated by the Fox equation. It was found that unusually strong solvent retention in the solution-cast membrane leads to considerable plasticization of the polymer, to possible foam formation upon drying and, most important, to significant changes in the permeation properties. The residual solvent increases the diffusion coefficient and permeability of the larger gas species up to almost one order of magnitude, and it reduces the permselectivity. For most gas species the solubility is about two times higher in the solvent-free melt-pressed film than in the solution-cast film. The relation between the residual solvent and the membrane properties is discussed.  相似文献   

3.
Experimental and theoretical results of studying gas permeation through porous membranes are presented. In order to mimic an asymmetric membrane two porous ceramic disks with different pore radii were arranged in series. Besides the possibility to perform conventional permeation measurements, the applied experimental setup permits the determination of the pressure at the interface between the two discs. To predict the performance of the asymmetric structure, in preliminary experiments structure parameters were determined for both membranes separately. For the same total pressure difference across the two-disk arrangement, different interlayer pressures and fluxes were predicted and detected experimentally depending on the flow direction.  相似文献   

4.
5.
Summary: The aim of the study was to investigate the variation in total surface area, porosity, pore size, Knudsen and surface diffusion coefficients, gas permeability and selectivity before and after the application of sol-gel process to porous ceramic membrane in order to determine the effect of pore modification. In this study, three different sol-gel process were applied to the ceramic support separately; one was the silica sol-gel process which was applied to increase porosity, others were silica-sol dip coating and silica-sol processing methods which were applied to decrease pore size. As a result of this, total surface area, pore size and porosity of ceramic support and membranes were determined by using BET instrument. In addition to this, Knudsen and surface diffusion coefficients were also calculated. After then, ceramic support and membranes were exposed to gas permeation experiments by using the CO2 gas with different flow rates. Gas permeability and selectivity of those membranes were measured according to the data obtained. Thus, pore surface area, porosity, pore size and Knudsen diffusion coefficient of membrane treated with silica sol-gel process increased while total surface area was decreasing. Therefore, permeability of ceramic support and membrane treated with silica sol-gel process increased, and selectivity decreased with increasing the gas flow rate. Also, surface area, porosity, pore size, permeability, selectivity, Knudsen and surface diffusion coefficients of membranes treated with silica-sol dip coating and silica-sol processing methods were determined. As a result of this, porosity, pore size, Knudsen and surface diffusion coefficients decreased, total surface area increased in both methods. However, viscous flow and Knudsen flow permeability were detected as a consequence of gas permeability test and Knudsen flow was found to be a dominant transport mechanism in addition to surface diffusive flow owing to the small pore diameter in both methods. It was observed that silica-sol processing method had lower pore diameter and higher surface diffusion coefficient than silica-sol dip coating method.  相似文献   

6.
A new method for determining the membrane transport parameters (diffusivity, permeability and solubility) of gases through nonporous polymeric membranes is described. The method employs a continuous permeation chamber containing a flat membrane. The most important feature of this method is that, instead of a step concentration change, a rectangular pulse or impulse is sent to the upstream side of the membrane. Consequently, no steady state is approached but a signal peak of typical form can be recorded. The permeability and the diffusivity can be estimated from the height and half-width of the peak, respectively. The method was applied to measure the permeability of hydrocarbons through a polyethylene membrane, the permeation rate being measured by a flame ionization detector. The method and the derived relations are valid for other detectors and gas—membrane combinations as well. The advantages of this novel method are that all the membrane transport parameters can be directly evaluated from data of the response peak, whilst approaching the steady state is not necessary and thus the measuring time can be shortened. Finally, the known and new differential permeation rate methods are compared by generalization of the relationship between the input and output (response) functions.  相似文献   

7.
Erythrocyte membrane permeability coefficients for a series of diols have been defined by the method developed. The method is based on the physical and mathematical modeling of hypotonic hemolysis process. There have been also determined membrane permeability coefficients for erythrocytes treated with p-chloromercuribenzenesulfonic acid monosodium salt (pCMBS), which is known to block aqueous protein channels. Permeating process is shown to be conditioned both by hydrophilic/hydrophobic properties of the molecules and their geometrical parameters. The obtained results propose that, when exceeding the molecules diameter over a value of 4 A, the permeability coefficient reduces due to decreasing of flow through the aqueous protein pores of a constant size. Permeability coefficients for comparatively hydrophobic molecules are almost directly proportional to the coefficients of partition between hydrophobic and hydrophilic phases, by pointing to a lipid way of permeation of these molecules through erythrocyte membranes.  相似文献   

8.
Accuracy of the gas permeability parameters (GPPs), i.e. solubility, diffusivity and permeability deduced from permeation measurements, is investigated for the case of homogeneous polymer sheet samples. The widely used time-lag method (TLM) and the recently introduced full curve-fitting method (FCFM) are compared on simulated and on measured permeation curves artificially distorted in various ways in order to mimic potential deficiencies of permeation measurements. Accuracy of the methods is defined as the relative deviation of the calculated from the real GPPs, i.e. those which are deduced from the distorted and the original, non-distorted curves, respectively. The following distortions have been applied: temporal truncation of the permeation curves, increasing the noise level of the measurement and shifting the permeation curve either along the concentration or the time axis. (The latter two transformations correspond to an unnoticed background shift in the readings of the concentration detection unit and an uncertainty in the actual inception of the permeation process, respectively). While all these distortions mimic realistic deficiencies of permeation measurements, the last one is relevant only in case of fast permeation processes through highly permeable membranes. For all but the last transformation, FCFM has been found to yield more accurate GPPs than TLM.  相似文献   

9.
The dusty gas model (DGM) is used to describe transport of binary gas mixtures through porous membrane supports to quantify the resistance towards permeation. The model equations account for three different transport mechanisms for the permeating components: conventional viscous pore flow, Knudsen diffusion, and binary diffusion. Experimental data obtained with the uncoated membrane supports are used to determine the morphological parameters needed in the DGM equations. Flat sheet and hollow fiber membrane supports are characterized by the permeation of a TCE/nitrogen vapor. The DGM shows an excellent fit to experimental data when the asymmetric structure of the membrane supports is taken into account, but the morphological parameters cannot necessarily be related to precise physical structure parameters such as pore size, porosity, and tortuosity. The DGM works well even when the membrane supports are modeled as a single homogenous structure. The membrane supports exhibit different resistances towards the various transport mechanisms that occur within the porous support and the resistances vary with process conditions so that support optimization is not straightforward. With the analysis presented in this paper and transport equations specific to the dense coating and module geometries, the influence of the support layer on gas or vapor separation can be quantified.  相似文献   

10.
The epoxidation of styrene–butadiene–styrene triblock copolymer (SBS) by an in situ generated peracid method is discussed. The presence of an acid acting as catalyst led to side reaction. The reactivities of internal double bonds (the 1, 4-structure) were higher than those of the vinyl bonds (the 1, 2-structure). In the 1, 4-structure, the reactivities of cis-structure were higher than those of trans-structure. The oxirane weight content and total oxygen weight content were determined by titration and element analysis, respectively. The cohesive energy, solubility parameter, and the glass transition temperature of epoxidized SBS increased with increasing total oxygen weight content. But the molecular weight between crosslinking points decreased resulting in an increase of crosslinking density with increasing total oxygen weight content. The changes of properties of epoxidized SBS reduced the gas permeability of oxygen and nitrogen through epoxidized SBS membrane, but increased the gas selectivity between oxygen and nitrogen. When the operating temperature of gas permeation was increased, the permeability of oxygen and nitrogen increased but the selectivity decreased. For epoxidized SBS containing 7.35 wt % oxygen content, the activation energy was 9 and 12.2 kcal/mol for oxygen and nitrogen, respectively.  相似文献   

11.
This work deals with water-swollen hydrogel membranes for potential CO2 separation applications, with an emphasis on elucidating the role of water in the membrane for gas permeation. A series of hydrogel membranes with a wide range of water contents (0.9–10 g water/g polymer) were prepared from poly(vinyl alcohol), chitosan, carboxyl methyl cellulose, alginic acid and poly(vinylamine), and the permeation of CO2, H2, He and N2 through the membranes at different pressures (200–800 kPa) was studied. The gas permeabilities through the dry dense membranes were measured as well to evaluate the resistance of the polymer matrix in the hydrogel membranes. It was shown that the gas permeability in water-swollen membrane is lower than the gas permeability in water, and the selectivity of the water-swollen membranes to a pair of gases is close to the ratios of their permeabilities in water. The permeability of the water-swollen membranes increases with an increase in the swelling degree of the membrane, and the membrane permeability tends to level off when the water content is sufficiently high. A resistance model was proposed to describe gas permeation through the hydrogel membranes, where the immobilized water retained in the polymer matrix was considered to form transport passageways for gas permeation through the membrane. It was shown that the permeability of hydrogel membranes was primarily determined by the water content in the membrane. The model predictions were consistent with the experimental data for various hydrogel membranes with a wide range of water contents (0.4–10 g water/g polymer).  相似文献   

12.
Separation of benzene from cyclohexane was performed using two types of liquid membranes, i.e., a supported liquid membrane and a flowing liquid membrane. Silver nitrate was used as the carrier of benzene. The permeation rate of benzene increased with increasing carrier concentration, and the separation factor, which is defined as the ratio of permeability of benzene to that of cyclohexane, was about 630 when the supported liquid membrane prepared by immobilizing 4 mol/L aqueous silver nitrate solution in cellulose filter paper was used. Compared with the supported liquid membrane, the flowing liquid membrane, where a liquid membrane solution was forced to flow in a thin compartment between two microporous membranes, showed one order of magnitude higher permeation rate at high flow rate of the membrane solution. The flowing liquid membrane was very stable and no noticeable decrease in both the flux and the selectivity was observed during 11 days operation. The mechanisms of the facilitated transport of benzene through both types of liquid membrane were proposed. The permeation rate and the selectivity were quantitatively simulated by the proposed model.  相似文献   

13.
This paper studies the diffusive and sorption steps of several gases across membranes cast from poly(N-phenyl-exo,endo-norbornene-5,6-dicarboximide) chloroform solutions. Chains packing effects on gas transport was investigated by conducting a parallel study on the permeation characteristics of membranes cast from hydrogenated poly(N-phenyl-exo,endo-norbornene-5,6-dicarboximide) chloroform solutions. The permeability coefficients of several gases in the two membranes were measured finding that hydrogenation of the norbornene moieties decreases gas permeability. The transition states approach was used to determine the trajectories of the gases in the two types of membranes from which the diffusion coefficients were obtained. Monte Carlo techniques based on the Widom method were used to simulate gas sorption process as a function of pressure. The values of the solubility coefficients thus obtained undergo a relatively sharp drop at low pressures approaching to a constant value as pressure increases. With the exception of carbon dioxide, pretty good agreement between the experimental and simulated values of the permeability coefficient is found for the gases studied.  相似文献   

14.
The development of a gas sampler for a miniaturized ambient ammonia detector is described. A micromachined channel system is realized in glass and silicon using powder blasting and anodic bonding. The analyte gas is directly mixed with purified water, dissolving the ammonia that will dissociate into ammonium ions. Carrier gas bubbles are subsequently removed from the liquid stream through a venting hole sealed with a microporous water repellent PTFE membrane. A flow restrictor is placed at the outlet of the sampler to create a small overpressure underneath the membrane, enabling the gas to leave through the membrane. Experiments with a gas flow of 1 ml min(-1), containing ammonia concentrations ranging from 9.4 ppm to 0.6 ppm in a nitrogen carrier flow have been carried out, at a water flow of 20 microl min(-1). The ammonium concentration in the sample solution is measured with an electrolyte conductivity detector. The measured values correspond with the concentration calculated from the initial ammonia concentration in the analyte gas, the fifty times concentration enhancement due to the gas-liquid volume difference and the theoretical dissociation equilibrium as a function of the resulting pH.  相似文献   

15.
Polymer/liquid crystal composite membranes were cast from a 1,2-dichloroethane solution of polycarbonate (PC) and N-(4-ethoxybenzylidene-4'-n- butylaniline) (EBBA). The mixing state of the polymer/liquid crystal composite membrane was investigated on the basis of differential scanning calorimetry, x-ray, density, sorption isotherm and sorption—desorption studies and also by electron microscopic observations. EBBA molecules in the composite membrane exist in an almost molecularly dispersed state up to an EBBA fraction of 30 wt%, and in the case of EBBA fractions above 30 wt% form a crystal domain as the mutual continuous phase among the network of polycarbonate fibrils. The composite membrane containing EBBA of 60 wt% can be handled as a homogeneous medium when considering gas permeation.The diffusive permeability coefficient to water reveals a distinct jump in the vicinity of the crystal—liquid crystal phase transition temperature of EBBA. The permeability coefficients, P, to hydrocarbon gases increases 100-200 times over several degrees in the phase transition temperature range. P for hydrocarbon gases decreases with increasing number of carbon atoms below the phase transition temperature, but increases with increasing number of carbon atoms above it. These results suggest that the permeation process is predominantly controlled by diffusion mechanism below the transition temperature of EBBA, while the solubility factor significantly affects gas permeation above it.  相似文献   

16.
 The preparation of calibration gas mixtures for air pollution measurements by the dynamic-gravimetric method was investigated using sulphur dioxide in nitrogen as a model. The target mole fraction was 200×10–9 mol/mol, with the option of also getting smaller mole fractions. Thermal mass flow meters calibrated with reference mass flows were used to measure the dilution gas flow (nitrogen). The relative standard uncertainty of the dilution gas flows between 10 mg/s (approx. 500 ml/min) and 40 mg/s (approx. 2000 ml/min) was 0.15%. The mass flow of the target component measured as the permeation rate was determined via the quasi-continuous observation of the loss in the permeation tube mass during the measuring time. A magnetic coupling system and an adapted microbalance were used for this purpose. The results presented show permeation rates measured over the lifetime of a tubular permeation source. The measurement cycles took between 3 days and 7 h at least. The relative standard uncertainty of the mixture composition did not exceed 2%. First comparisons with gas mixtures prepared by the static-gravimetric method show compatibility. The applicability of the system is not restricted to the SO2/N2 mixture. It can also be used for preparing other gas mixtures in this field of application. Received: 26 April 2000 / Accepted: 12 September 2000  相似文献   

17.
Summary A new sample focusing technique for capillary gas chromatography is described. The system is designed as a focusing inlet for thermally desorbed gas samples. A solid-sorbent trapped sample is thermally released from the sample tube, transferred to a palladium/silver membrane chamber by a hydrogen carrier gas stream and retained there by the gas separation membrane, which is highly permeable to the carrier gas. After focusing in the membrane chamber the sample is injected onto the separation column. This technique allows focusing and injection of highly volatile compounds in capillary gas chromatography without using any coolant. The injection performance for n-alkanes is shown to be comparable to the cryofocusing technique.  相似文献   

18.
Pure gas permeation and sorption experiments were carried out for the gases ethylene, ethane, propylene and propane using polyimides based on 4,4′-(hexafluoroisopropylidene) diphthalic anhydride (6FDA). Composite membranes and free films were used. Experiments were performed at 308 K and feed pressures up to 17 atm for ethylene and ethane and 9 atm for propylene and propane. Mixed gas permeation experiments were carried out with 50 : 50 olefin/paraffin feed mixtures. For all investigated polyimides, the ideal ethylene/ethane separation factor ranged between 3.3 and 4.4 and the ideal propylene/propane separation factor ranged between 10 and 16 at a feed pressure of 3.8 atm and 308 K. In mixed gas permeation experiments, up to 20% lower selectivity was found for the ethylene/ethane separation and up to 50% reduced selectivity for the propylene/propane separation compared to the ideal selectivity. The influence of feed temperature on separation and permeation properties will be discussed based on pure gas permeability data at 298 and 308 K.  相似文献   

19.
    
Summary Investigations on two commercially available permeation tubes for preparation of test gas mixtures for calibration purposes in trace gas analysis have shown that, depending on the type of permeation membrane, variations of carrier gas pressure may strongly affect the outcoming test gas concentrations. At constant atmospheric pressure both devices work with concentration fluctuations of about 3 to 5%. With carrier gas overpressures up to 2000 mbar the behaviour of permeation tubes with a rigid PTFE-membrane remains almost unchanged whereas test gas generators with soft membranes, e.g. silicon rubber, give a very strong decrease of permeation rate down to 17% of the value at atmospheric pressure. Consequently, the selection of permeation devices demands high carefulness with regard to the ambient pressure at the site of application.  相似文献   

20.
A dynamic method for investigating the mechanism of permeation and diffusion through polymers has been explored. The permeation cell consists of two compartments separated by the membrane. The permeant (gas, vapor, or liquid) is introduced into one compartment; a carrier gas (helium) flows at constant rate through the other and sweeps the permeant which diffuses through the membrane to the thermal conductivity detector. Both compartments are at atmospheric pressure; thus no or little membrane support is required, and leakage problems are minimal. Moreover, the same membrane can be used over a wide temperature range and for diverse permeants. The detector signal is at any instant proportional to the permeation rate. A simple mathematical formalism for deriving the diffusion coefficient from the transient permeation rates has been developed. The measured diffusion and permeability coefficients of CO2, O2, and N2 through low-density polyethylene closely agree with literature values. Permeation of hexane and benzene through polyethylene follows a complex diffusion law, and the rate depends on the thermal history of the system. The dynamic method is particularly suited to the study of transitions in polymers. Changes in permeation rates, usually occurring at transition points, can easily be discovered by slow temperature scanning of the system.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号