首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Samplers for VOCs in air based on cyclodextrin-silica hybrid microporous solid phases are proposed. The solid phase preparation is very easy and inexpensive. Proposed samplers compared with other solid phases present the advantages of a wider range of operative conditions for VOCs desorption. Samplers are tested based on results for the determination of benzene, toluene, ethylbenzene and o-xylene, m-xylene and p-xylene (BTEX) in air. Operational parameters are optimized and quantitative recovery is obtained using a solid phase from 2-hydroxypropyl-β-cyclodextrin and acetonitrile as the extraction solvent. The recoveries obtained are 89 ± 4%, 90 ± 6%, 91 ± 2%, 87.0 ± 0.9%, 88 ± 4%, and 88 ± 4% for benzene, toluene, ethylbenzene, o-xylene, m-xylene and p-xylene, respectively. Moreover results indicate a good reproducibility with a coefficient of variation below 6% and no significant difference between the reproducibility intra-synthesis and inter-synthesis. The proposed procedure has been applied to the determination of BTEX in several contaminated air samples and compared with results provided by a reference method.  相似文献   

2.
In this paper solid phase microextraction (SPME) and needle trap device (NTD) as two in-progress air monitoring techniques was applied with silylated composite of carbon nanotubes for sampling and analysis of perchloroethylene in air. Application of SPME and NTD with proposed nano-structured sorbent was investigated under different laboratory and experimental parameters and compared to the SPME and NTD with CAR/PDMS. Finally the two samplers contained nano-sorbent used as a field sampler for sampling and analysis of perchloroethylene in dry cleaning. Results revealed that silica composite form of CNTs showed better performance for adsorbent of perchloroethylene. SPME and NTD with proposed sorbent was demonstrated better responses in lower levels of temperature and relative humidity. For 5 days from sampling the relative responses were more than 97% and 94% for NTD and SPME, respectively. LOD were 0.023 and 0.014 ng mL−1 for SPME coated CNTs/SC and CAR/PDMS, and 0.014 and 0.011 ng mL−1 for NTD packed with CNTs/SC and CAR/PDMS, respectively. And for consecutive analysis RSD were 3.9–6.7% in laboratory and 4.43–6.4% in the field. In the field study, NTD was successfully applied for determining of the PCE in dry cleaning. The results show that the NTD packed with nanomaterial is a reliable and effective approach for the sampling and analysis of volatile compounds in air.  相似文献   

3.
A new cryogenic integrative air sampler (patent application number 08/00669), able to overcome many of the limitations in current volatile organic compounds and odour sampling methodologies is presented. The sample is spontaneously collected in a universal way at 15 mL/min, selectively dried (reaching up to 95% of moisture removal) and stored under cryogenic conditions. The sampler performance was tested under time weighted average (TWA) conditions, sampling 100 L of air over 5 days for determination of NH3, H2S, and benzene, toluene, ethylbenzene and xylenes (BTEX) in the ppmv range. Recovery was 100% (statistically) for all compounds, with a concentration factor of 5.5. Furthermore, an in-field evaluation was done by monitoring the TWA inmission levels of BTEX and dimethylethylamine (ppbv range) in an urban area with the developed technology and comparing the results with those monitored with a commercial graphitised charcoal diffusive sampler. The results obtained showed a good statistical agreement between the two techniques.  相似文献   

4.
Radiello® diffusive samplers filled with a thermally desorbable adsorbent (graphitised charcoal Carbograph 4) have been tested for the monitoring of BTEX. The sampling rates have been estimated under various controlled atmospheres in order to evaluate the effects of two factors (exposure time, concentration levels and their interaction) on the performances of the Radiello® sampler. Experiments have been carried out under various atmospheres in exposure chamber. A total of 174 Radiello® samplers were exposed while varying two conditions: exposure time (1, 3, 7 and 14 days) and BTEX concentrations (low, medium and high levels). The results show that the sampling rates of benzene and toluene decrease for exposure of 14 days and especially for high concentration levels: decrease of 30% at 10 μg m−3 for benzene and 14% at 30 μg m−3 for toluene.

To try to explain the variations of these sampling rates, the breakthrough volumes (VB) of BTEX on Carbograph 4 have been determined at different temperature and concentration conditions in order to evaluate the Langmuir parameters and their adsorption enthalpy (−ΔHads) using the Van’t Hoff equation. With regard to these adsorption characteristics, the dependence of sampling rates with concentration level and exposure time were analysed and discussed.  相似文献   


5.
This paper presents the results of atmospheric air quality research in Tczew (adjacent to the Vistula River) on the content of BTEX compounds. procedure applied during the sampling of the analytes from the air used the passive sampling technique (diffusive passive sampler, Radiello®). For determination of BTEX compounds in atmospheric air, two-stage thermal desorption technique combined with gas chromatography (TD-GC-FID) was applied.

Research was conducted from March to December 2011. The annual average concentration of benzene, toluene, ethylbenzene and total xylenes determined in atmospheric air for the monitoring period were: 0.87 μg m–3, 2.9 μg m–3, 1.3 μg m–3 and 5.9 μg m–3, respectively. In order to pre-identify potential sources of emissions of BTEX compounds, statistical analysis was carried out. This determined interactions between specified concentration levels of BTEX compounds in atmospheric air for the monitored area.  相似文献   

6.
A passive air sampler, using 4-amino-3-hydrazino-5-mercapto-1,2,4-triazole, was evaluated for the determination of formaldehyde in indoor environments. Chromatography paper cleaned using a 3% hydrogen peroxide solution was experimentally determined as being the optimum absorption filter for the collection of formaldehyde (0.05 microg cm(-2) formaldehyde). From a linear-regression analysis between the mass of formaldehyde time-collected on a passive air sampler and the formaldehyde concentration measured by an active sampler, the sampling rate of the passive air sampler was 1.52 L h(-1). The sampling rate, determined for the passive air sampler in relation to the temperature (19 - 28 degrees C) and the relative humidity (30 - 90%), were 1.56 +/- 0.04 and 1.58 +/- 0.07 L h(-1), respectively. The relationship between the sampling rate and the air velocity was a linear-regression within the observed range. In the case of exposed samplers, the stability of the collected formaldehyde decreased with increasing storage time (decrease of ca. 25% after 22 days); but with the unexposed samplers the stability of the blank remained relatively unchanged for 7 days (decrease of ca. 37% after 22 days). The detection limits for the passive air sampler with an exposure time of 1 day and 7 days were 10.4 and 1.48 microg m(-3), respectively.  相似文献   

7.
Gaseous benzene, toluene, ethylbenzene and o‐xylene (BTEX) were extracted by using the divinylbenzene (DVB) particles (mesh sizes 60–80, 80–100 and 100–120) as sorbents packed in passive needle trap samplers (NTS). This study performed feasibility tests of these self‐designed DVB‐NTS as diffusive time‐weighted average (TWA) samplers and compared extraction efficiency with that of 100 mm polydimethylsiloxane‐solid phase microextration (PDMS‐SPME) fiber for sampling gaseous and particle‐bound volatile organic compounds (VOCs) from burning mosquito coils. Experimental results indicated that extraction rate of NTS is a reliable index in extracting VOCs. Additionally, comparisons of the NTS in extracting BTEX mass showed the NTS packed with the smallest diameters of adsorbent particles (100–120 mesh DVB) were the most effective. The mass of gaseous BTEX extracted by 100 μm PDMS‐SPME fiber were substantially lower than that extracted by DVB‐NTS of all meshes for the 30‐min TWA sampling of burning mosquito coils, and NTS packed with 100–120 mesh DVB adsorbed BTEX 50–120 ng BTEX. Particles clogging inside the packed phase of NTS inhibited VOC extraction performance after 3–5 samplings of burning particles, especially NTS packed with small‐diameter adsorbents.  相似文献   

8.
This paper examines the results of experiments carried out in an exposure chamber to determine the wind effects on the performance of various diffusive sampler types commonly used for measuring gaseous pollutants in air. The resistance to wind of six diffusive samplers, two Palmes tubes, a badge with diffusion membrane, the EMD sampler and two radial diffusive samplers for different pollutants was compared in a range of velocities from 0 to 300?cm?s?1. For all diffusive samplers tested, an increase in uptake rate was observed with increased air velocity usually following a logarithmic function. The consequences are an underestimation in the concentration measured by the diffusive samplers for low wind velocities below 30?cm?s?1 and conversely an overestimation from 60?cm?s?1. The magnitude of wind effects depends on diffusive sampler type and exceeds an uptake rate variation of ±20% for the axial diffusion tubes and the EMD sampler. With regard to the characteristics of each diffusive sampler, the dependence of uptake rate on wind velocity was analysed and discussed. The radial diffusive samplers for benzene and particularly the ones having a large and thick porous membrane appear to be the most effective design to minimise the influence of air velocity on passive sampling.  相似文献   

9.
Summary A diffusive sampler for the large scale routine determination of airborne formaldehyde was developed. Formaldehyde is sampled in a badge-type passive sampler containing a 2,4-dinitrophenylhydrazine-coated filter paper as sampling layer. Formaldehyde is immediately converted to the corresponding hydrazone, which, after desorption with acetonitrile, is separated and quantified by gradient HPLC using UV detection at 345 nm. Calibration was done via an active sampling method and showed an excellent, time- and concentration-independent linear performance of the diffusive samplers. A detection limit of about 0.05 ml/m3·h (ppm·h) and a relative standard deviation of about 10% ensured a good analytical reliability. By testing the influence of air movements at the sampler surface, a minimum air velocity of 10 cm/s was found necessary to ensure representative sampling.  相似文献   

10.
The aim of the study was to analyse BTEX compounds (benzene, toluene, ethylbenzene, xylenes) in air by solid phase micro-extraction/gas chromatography/mass spectrometry (SPME/GC/MS), and this article presents the features of the calibration method proposed. Examples of real-world air analysis are given. Standard gaseous mixtures of BTEX in air were generated by dynamic dilution. SPME sampling was carried out under non-equilibrium conditions using a Carboxen/PDMS fibre exposed for 30 min to standard gas mixtures or to ambient air. The behaviour of the analytical response was studied from 0 to 65 g/m3 by adding increasing amounts of BTEX to the air matrix. Detection limits range from 0.05 to 0.1 g/m3 for benzene, depending on the fibre. Inter-fibre relative standard deviations (reproducibility) are larger than 18%, although the repeatability for an individual fibre is better than 10%. Therefore, each fibre should be considered to be a particular sampling device, and characterised individually depending on the required accuracy. Sampling indoor and outdoor air by SPME appears to be a suitable short-delay diagnostic method for volatile organic compounds, taking advantage of short sampling time and simplicity.  相似文献   

11.
We have investigated the ability of an integrative sampler for polar organic chemicals to sequestrate a group of common and highly hazardous cyanobacterial toxins—microcystins. In a pilot experiment, commercially available passive samplers were shown to effectively accumulate microcystins after 7 days’ exposure in the field. To find the most efficient configuration for sequestration of microcystins, four different porous membranes (polycarbonate, polyester, polyethersulfone and nylon) and two sorbents (Oasis HLB and Bondesil-LMS) were evaluated in the laboratory experiments, where samplers of different configuration were exposed to microcystins (microcystin-RR and microcystin-LR) for 14 days under steady conditions. We observed differences in sampling rates and amounts of accumulated microcystins depending on the sampler configurations. The samplers constructed with the polycarbonate membrane and Oasis HLB sorbent (2.75 mg/cm2) provided the highest sampling rates (0.022 L/day for microcystin-RR and 0.017 L/day for microcystin-LR). To the best of our knowledge, the present study is the first reporting application of passive samplers for microcystins, and our results demonstrate the suitability of this tool for monitoring cyanotoxins in water.  相似文献   

12.
A novel diffusive sampler that combines radial and axial diffusion has been developed that improves upon existing commercially available designs. The POcket Diffusive (POD) sampler has been validated under laboratory and field conditions for the measurements of VOCs in ambient air. Laboratory tests varied sampling conditions of temperature (−30–40 C), humidity (10–80%), wind velocity (0.1–4 m s−1), and concentration (0.5–50 μg m−3) for a number of specific VOCs. An overall uncertainty of circa 9% for the measurement of benzene is calculated for the validation tests, in compliance with the data quality objectives of the EU air quality directive 2008/50/EC. A semi-empirical diffusion model has been developed to estimate sampling rates for compounds that were not tested, and for conditions outside of tested ranges during validation. The diffusion model (and validation tests) shows a low influence of environmental conditions on the sampling rate for the POD sampler. Average reproducibility values of circa 3% are reported with overall sampling uncertainties ranging from 9% to 15%, for the whole range of tested conditions, depending on the compound. The adsorbent cartridge is compatible with existing thermal desorption systems in the market. The diffusive sampler can modify the sampling rate by changing the diffusive body within a range of different porosities. Field tests, conducted in parallel with independent quality controlled canister sampling, confirmed the ease of use and quality of VOC measurements with the POD sampler, for compounds that were, and were not, evaluated during laboratory tests.  相似文献   

13.
The applicability of a tube-type diffusive sampler as an environmental monitor for benzene, toluene, ethylbenzene and xylene (BTEX) is reported. Uptake rates have been experimentally determined for a novel type adsorbent, Tenax GR, and compared to theoretical values. It is shown, that the uptake rates are virtually independent of environmental parameters within the experimental conditions studied. The response of the sampler to transient changes in concentrations has been determined in the laboratory. It is found that the sampler is capable of following an extreme concentration profile. Field comparisons with pumped samplers have been performed and good agreement is observed between the results of the two independent methods. The samplers have also been applied as environmental monitors at different locations.  相似文献   

14.
A tetraquinoxaline cavitand functionalized with methylenoxy bridges at the upper rim is proposed as selective solid-phase microextraction (SPME) coating for the determination of BTEX at trace levels in air. The SPME fibers were characterized in terms of film thickness, morphology, thermal stability and extraction capabilities. An average coating thickness of 35 (±4) μm, a thermal stability up to 350 °C and a good fiber-to-fiber and batch-to-batch repeatability with RSD lower than 15% were obtained. Excellent enrichment factors ranging from 360–700 × 103 were obtained for the investigated compounds. Finally, method validation proved the capabilities of the developed coating for the selective sampling of BTEX, achieving LOD values in the 0.4–1.2 ng m−3 range.  相似文献   

15.
A simple and cost effective permeation passive sampler equipped with a polydimethylsiloxane (PDMS) membrane was designed for the determination of time-weighted average (TWA) concentrations of volatile organic compounds (VOCs) in air. Permeation passive samplers have significant advantages over diffusive passive samplers, including insensitivity to moisture and high face velocities of air across the surface of the sampler. Calibration constants of the sampler towards 41 analytes belonging to alkane, aromatic hydrocarbon, chlorinated hydrocarbon, ester and alcohol groups were determined. The calibration constants allowed for the determination of the permeability of PDMS towards the selected analytes. They ranged from 0.026 cm2 min−1 for 1,1-dichloroethylene to 0.605 cm2 min−1 for n-octanol. Further, the mechanism of analyte transport across PDMS membranes allowed for the calibration constants of the sampler to be estimated from the linear temperature programmed retention indices (LTPRI) of the analytes, determined using GC columns coated with pure PDMS stationary phases. Statistical analysis using Student's t test indicated that there was no significant difference at the 95% probability level between the experimentally obtained calibration constants and those estimated using LTPRI for most analyte groups studied. This correlation allows the estimation of the calibration constants of compounds not known to be present at the time of sampler deployment, which makes it possible to determine parameters like total petroleum hydrocarbons in the vapor phase.  相似文献   

16.
Summary A useful method of sampling and measurement of toluene diisocyanate concentration in atmosphere is described. The sampler consists of glass-fibre filters impregnated with the reagent 1-(2-methoxyphenyl)piperazine1 so that the 2,4 and 2,6 isomers of TDI react to form urea derivatives which are analysed by high performance liquid chromatography in isocratic mode on cyan-amino and C18 bonded phases. A dynamic system was used to generate standard atmospheres of TDI and to validate the sampling method within the humidity range of 0% to 75%. A coated filter, a bubbling solution and an impregnated silica gel were compared as samplers requiring the piperazine reagent in performance experiments.  相似文献   

17.
In this work cobalt oxide nanoparticles were introduced for preparation of a novel solid phase microextraction (SPME) fiber coating. Chemical bath deposition (CBD) technique was used in order for synthesis and immobilization of the Co3O4 nanomaterials on a Pt wire for fabrication of SPME fiber. The prepared cobalt oxide coating was characterized by scanning electron microscopy (SEM) and X-ray diffraction (XRD) analysis. The fiber was evaluated for the extraction of benzene, toluene, ethylbenzene and xylene (BTEX) in combination with GC–MS. A simplex optimization method was used to optimize the factors affecting the extraction efficiency. Under optimized conditions, the proposed fiber showed extraction efficiencies comparable to those of a commercial polydimethylsiloxane (PDMS) fiber toward the BTEX compounds. The repeatability of the fiber and its reproducibility, expressed as relative standard deviation (RSD), were lower than about 11%. No significant change was observed in the extraction efficiency of the new SPME fiber after over 50 extractions. The fiber was successfully applied to the determination of BTEX compounds in real samples. The proposed nanostructure cobalt oxide fiber is a promising alternative to the commercial fibers as it is robust, inexpensive and easily prepared.  相似文献   

18.
Welding fume samples were collected in two Hungarian welding plants, where different types of steels were welded with metal active gas (MAG) welding. Welding fumes were sampled with “fixed point” and personal sampling techniques applying different sampling heads: Institute of Occupational Medicine (IOM) sampler and conical inhalable sampler (CIS) for the inhalable aerosol fraction and the Higgins-Dewell (HD) cyclone for the respirable fraction. When sampled, the welding fume samples were digested with the mixture of nitric acid and hydrogen peroxide in a closed vessel microwave digestion system. The Cr, Mn, Ni and Co contents of the solutions were determined by inductively coupled plasma atomic emission spectrometry (ICP-AES) and inductively coupled plasma mass spectrometry (ICP-MS). Iron was analysed only by the ICP-AES method. Metal concentrations of the workplace air were calculated for the three samplers, and the results were compared to each other. The differences of the metal concentrations determined by the different inhalable sampling heads, which were paired during the sampling, proved not to be significant. Therefore, the IOM and CIS heads can be equally used for the sampling of welding fume. Finally, the distributions of metals were determined between the inhalable and respirable fractions. Metal concentrations in the respirable aerosol fraction were 57-98% of the concentrations in the inhalable fraction. These high rates of metals in the respirable aerosol call the attention to the increased health risk of the welding fume.  相似文献   

19.
Capillary extractors are proposed as samplers-preconcentrators to overcome losses of volatile organic compounds found using "classical" solid-phase microextraction fiber-holder samplers. A set of equal-size extractors was used to extract in-tube an aqueous solution of benzene, toluene, ethylbenzene and xylenes (BTEX) at 146 ppb. After storage for 6-30 days at 0-4 degrees C (or -15 degrees C) GC analyses were carried out to study BTEX recovery. Results demonstrated that sample preservation was very good: recovery was higher than 98% after 6 days, and more than 95% after 30 days. Capillary extractors, due to their high performance in preserving sample integrity, represent a real breakthrough for on-site sampling of volatile compounds by solid-phase pre-concentration techniques.  相似文献   

20.
Two types of passive samplers differing in their geometry (OVM 3500 by 3M, ORSA 5 by Dräger) were compared with respect to their suitability for typical environmental indoor and outdoor VOC concentrations. Benzene, toluene, o-, m-, p-xylene, ethylbenzene, tetrachloroethene, trichloroethene, nonane and ethyl acetate were representatively analyzed by dual-column capillary gas chromatography with tandem ECD-FID detection. There was a good correlation between the results obtained with OVM 3500 and ORSA 5 monitors indicating that both monitors can be used for this kind of application. The ratio between the results for indoor air sampling with OVM 3500 and ORSA 5 monitors was between 0.89 and 1.14 showing no systematic variation. For outdoor air sampling the ratio was between 1.06 and 1.26 indicating that the results obtained with OVM 3500 monitors were slightly higher. Reproducibility was slightly better when using ORSA 5 monitors. But, due to the higher sampling rates which are a result of the larger cross-sectional area, signal-to-noise ratios obtained with OVM 3500 monitors were between six to nine times higher than those of ORSA 5 samplers. Blank values of the unexposed samplers were comparable for both sampler types. As a consequence, detection limits were by a factor of 1.5 to 4 better for OVM 3500 monitors.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号