首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A new method has been developed for in-situ separation of Pd from a Pt matrix and determination of trace Pd based on different vaporization temperatures by electrothermal vaporization (ETV) inductively coupled plasma optical emission spectrometry (ICP-OES) with the use of polythioether backbone modified with a diaminoisopropylmercaptane chelating group (YPA4), both as solid phase extractant and chemical modifier. In 0.5M HNO3, Pd and Pt can be adsorbed by YPA4. The resin loaded with Pd and Pt was then prepared to form a slurry that can be directly introduced into the graphite furnace without any pretreatment. The factors affecting in-situ separation of Pd from the Pt matrix were investigated in detail. It was found that, in the presence of YPA4, Pd could be quantitatively vaporized at lower vaporization temperatures (1800°C–1900°C), while Pt could not be vaporized from the graphite furnace at the same temperature, its quantitative vaporization temperature being 2600°C. Based on the different vaporization temperatures, in-situ separation of Pd from the Pt matrix and determination of trace Pd by ETV-ICP-OES was achieved in the temperature range of 1800°C–1900°C. Under the optimized conditions, the detection limit (3) of Pd is 60pg, and the relative standard deviation (RSD) is 5.6% (n=9, C=0.2µgmL–1). The method has been applied to the determination of trace Pd in anode slime and Auto Catalyst NIST SRM 2557 reference material, and the determined values coincide with the certified values.  相似文献   

2.
A new approach, based on non-aqueous capillary electrophoresis separation and indirect photometric detection, was established for the determination of the transition metal ions Pb2+, Zn2+ and Cd2+. Under optimized conditions, the method produced baseline separation of these three metal ions. The linear range and detection limits were 1050µM, 1.9µM for Cd2+; 1050µM, 2.1µM for Zn2+; and 20100µM, 3.8µM for Pb2+, respectively.  相似文献   

3.
The fabrication and electrochemical characteristics of a penicillamine (PCA) self-assembled monolayer modified gold electrode were investigated. The self-assembled electrode shows obvious electrocatalytic activity for the oxidation of epinephrine (EP). In phosphate buffer (pH 7.73), a sensitive oxidation peak was observed at 0.190V with the PCA modified Au electrode. The peak current is proportional to the concentration of EP in the range of 2.0×10–56.0×10–4molL–1 and 5.0×10–6 2.0×10–4molL–1 for cyclic voltammetry (CV) and differential pulse voltammetry (DPV) with the detection limits of 1.8×10–7 and 1.3×10–7molL–1, respectively. The possible reaction mechanism is also discussed. The PCA self-assembled monolayer modified gold electrode is highly stable and can be applied to the determination of EP in practical injection samples. Application is simple, rapid and produces accurate results.  相似文献   

4.
A novel nano-TiO2 polymer modified glassy carbon (GC) electrode was developed for the determination of an organophosphorous pesticide, fenitrothion (-NO2), in citrate buffer solution. The electrochemical behavior of fenitrothion was characterized by using cyclic voltammetry. An irreversible form, -NO2, was transformed into a reversible redox couple (-NHOH/-NO), and it can be used to determine trace fenitrothion by square wave voltammetry. The experimental parameters, such as film thickness, pH value, accumulation potential and time were optimized. Interestingly, a cyclic voltammetric scan was observed to be more effective than a constant potential for the accumulation of fenitrothion. A linear response over a fenitrothion concentration of 2.5×10–8 to 1.0×10–5M was exhibited, with a detection limit of 1.0×10–8M (S/N=3). The high sensitivity and selectivity of this film electrode was demonstrated by its practical application to the determination of trace amounts of fenitrothion in lake water and apple samples.  相似文献   

5.
Osmocene (and decamethylosmocene) is characterized by a lowest-energy ligand field triplet which occurs at max=372nm (374nm) in absorption and 567nm (572nm) in emission. This orange–yellow phosphorescence is rather intense at 77K but is also visible at r.t.  相似文献   

6.
A method for the determination of trace amounts of arsenic in food samples using flow injection analysis and atomic absorption spectrometry with hydride generation (FI-HG AAS) was developed. The parameters of the flow injection system and the hydride generation were optimized with respect to reagent concentrations, atomization temperature, injection volume, reaction coil length and carrier flow rate. The limits of detection and quantification were 0.34µgL–1 and 1.2µgL–:1, respectively, and the analytical curve is linear up to 30.0µgL–1 arsenic. The relative standard deviation for 12 replicates varies between 5% for 4.0µgL–1 As and 1.8% for 30.0µgL–1 As, with an injection frequency of up to 135h–1. Interferences from Ni(II), Cu(II), Fe(III), Cr(III), Mo(II), Bi(III), Se(IV), Se(VI), Sb(III) and Sb(V) could be masked with a mixture of ascorbic acid-KI in a 5.0molL–1 HCl solution. The accuracy of the proposed method was evaluated by using certified reference materials of biological samples, and the method was used to determine the content of arsenic in fish and coffee beans.  相似文献   

7.
A comparative study of commercial C18 chemically immobilized on silica and homemade C18, as sorbents for Pb complexed with O,O-diethyl-dithiophosphate (DDTP) in a flow injection preconcentration system is reported. The homemade C18 sorbent was obtained by sorption of poly(methyloctadecylsiloxane) (PMODS) on the silica support followed by immobilization using thermal treatment. The method follows the concept of green chemistry, since there are no toxic residues after synthesis. The complexed Pb was formed in 1.0molL–1 HCl medium and retained on the minicolumn filled with the sorbents. The elution was carried out using ethanol, and the richest 210µL fraction was collected and analyzed by flame atomic absorption spectrometry. Chemical and flow variables were optimized for each sorbent. The results demonstrated that the performance of the proposed homemade C18 sorbent for preconcentration of Pb complexed with DDTP is very similar to commercial C18 chemically bonded on silica. By processing 25mL, the enrichment factors were 129 and 125 for commercial C18 and homemade C18, respectively. The limit of detection for commercial and homemade C18 was 0.2µgL–1 and 0.6µgL–1, respectively. The relative standard deviation (RSD) was lower than 1.2% for both sorbents for a Pb concentration of 100µgL–1. The method was also applied successfully to the analysis of water samples, and the accuracy was tested by recovery measurements on spiked samples and biological reference material.  相似文献   

8.
2,3-Dihydroxypyridine loaded (via –N=N–linker) Amberlite XAD-2 (AXAD-2-DHP) was prepared and characterized by elemental analyses, TGA and FT-IR spectra. It (1g packed in a column of 1cm diameter; surface area 135.5m2g–1) was found to be an effective solid phase sorbent for enriching Zn2+, Mn2+, Ni2+, Pb2+, Cd2+, Cu2+, Fe3+ and Co2+ at pH 3.5 to 7.0 using flow rates between 1.0–5.0mLmin–1. For desorption (recovery 97.0–99.8%) of the metal ions, 8 to 10mL of 2.0molL–1 HCl or 1.5molL–1 HNO3 at a flow rate of between 2.0 and 4.0mLmin–1 were found most suitable. The t1/2 (time for 50% sorption) is between 2 and 10min when a 50mL solution (containing a total amount of metal of 2mg) was equilibrated with 0.5g of resin. Sorption of all metal ions except Pb2+ follows the Langmuir model, whereas for Pb the data fits with the Freundlich model. The sorption capacity is between 60.7 (for Cd) and 406.7 (for Cu) µmolg–1. The resin can withstand an acid concentration of 6molL–1 and can be reused for thirty cycles of sorption–desorption. The preconcentration factor varies between 100 and 300. For Cd, Ni and Cu the sorption capacity of 2,3-dihydroxypyridine loaded cellulose is lower than that of the present resin. The tolerance limits of electrolytes, humic acid, complexing agents, Ca2+ and Mg2+ in the enrichment of all metal ions are reported. The limits of detection are 3.88, 5.37, 8.72, 13.88, 4.71, 1.24, 0.59 and 0.30µgL–1 for Zn2+, Mn2+, Ni2+, Pb2+, Cd2+, Cu2+, Fe3+ and Co2+, respectively. The calibration curves for flame AAS determination were linear in the ranges 0.018–1.0, 0.067–5.0, 0.2–5.0, 0.9–20, 0.028–2.0, 0.077–5.0, 0.19–10 and 0.1–3.5µgmL–1, respectively. All the eight metal ions in river and synthetic water samples, Co in vitamin tablets and Zn in milk samples have been quantitatively enriched with Amberlite XAD-2-DHP and determined by flame atomic absorption spectrometry.  相似文献   

9.
A new method of SS-RTP for the determination of trace silver has been established. This method is based on the fact that Ag+, when activated by ,-bipyridyl (bipy) in a media of HAc–NaAc (pH=4.9), can catalyze the reaction of Rhodamine B (RhoB) oxidized by K2S2O8, thus causing the Solid Substrate Room-Temperature Phosphorescence (SS-RTP) of RhoB to be quenched. The activating efficiency of bipy is 6.7 times higher than that of o-phenanthroline (phen). The reduction of the phosphorescence intensity (Ip) of RhoB is directly proportional to the concentration of Ag+ ions in the range of 1.6016.0agspot–1 (0.40µLspot–1). The regression equation of the working curve can be expressed as Ip=18.78+5.100mAg+ (agspot–1) (r=0.9994, n=6), the detection limit is 0.28agspot–1. This rapid, accurate and sensitive method has been successfully applied to the determination of trace silver in tea and human hair samples, and the results agree well with the Atomic Absorption Spectroscopy (AAS) method. The mechanism of the catalyzing reaction is also discussed.  相似文献   

10.
This paper explores the production of carboxymethylcellulose (CMC) fromseveral bleached cellulose pulps obtained from non-wood species. The chemicalcomposition (-cellulose, hemicellulose and lignin content), the degreeofswelling, viscosity, solubility in concentrated NaOH and crystallinity ofsoda/AQ cellulose pulps from abaca, jute, sisal, linen and Miscanthussinensis were determined. The pulps were carboxymethylated by one andtwo successive reaction steps in aqueous medium under identical conditions. Thedegree of substitution (DS) of CMC was found to be dependent upon the source ofthe cellulose pulp, but generally it was close to 1 with one etherificationtreatment and around 2 after the second. The molar mass of CMC was found to bedependent on the initial intrinsic viscosity of the cellulose pulp. The weightaverage molar mass of our CMCs ranged from 1.5×105 to2.8×105. Increasing the DS up to 2 improved the CMC solubility, butviscosity slightly decreased due to a slight degradation of the polymer.  相似文献   

11.
A single-wall carbon nanotubes (SWNT) film coated glassy carbon electrode (GCE) was fabricated for the direct determination of 4-nitrophenol (4-NP). The electrochemical behaviors of 4-NP at the SWNT-film coated GCE were examined. In 0.1M phosphate buffer with a pH of 5.0, 4-NP yields a very sensitive and well-defined reduction peak at the SWNT-modified GCE. It is found that the SWNT film exhibits obvious electrocatalytic activity towards the reduction of 4-NP since it not only increases the reduction peak current but also lowers the reduction overpotential. Based on this, an electrochemical method was proposed for the direct determination of 4-NP. The reduction peak current varies linearly with the concentration of 4-NP ranging from 1×10–8 to 5×10–6M, and the detection limit is 2.5×10–9M after 3min of open-circuit accumulation. The relative standard deviation at 2×10–7M 4-NP was about 6% (n=10), suggesting excellent reproducibility. This new method was successfully employed to determine 4-NP in several lake water samples.  相似文献   

12.
This study aims to investigate the distribution of Na, K, Rb and Cs in human brains (5 individuals, 12 brain parts, mean age: 75 years). Distribution of the trace metals between lipid fraction and brain tissue was investigated in solvent extraction experiments. Determinations were carried out by instrumental neutron activation analysis. The present results show a rather non-homogeneous distribution for Na and a relatively uniform distribution for K, Rb and Cs. The mean concentrations found are 7440µgNag–1 dry weight, 12800µgKg–1, 14µgRbg–1 and 50ngCsg–1. A highly significant positive correlation was found between Rb and Cs. Solvent extraction experiments showed that 19% of Rb and 26% of Cs of the total content is located in lipid fraction.  相似文献   

13.
A new method for the simultaneous determination of heavy metal ions in Chinese herbal medicine by microwave digestion and reversed-phase high-performance liquid chromatography (RP-HPLC) has been developed. The Chinese herbal medicine samples were digested by microwave digestion. Lead, cadmium, mercury, nickel, copper, zinc, and tin ions in the digested samples were pre-column derivatized with tetra-(4-chlorophenyl)-porphyrin (T4-CPP) to form the colored chelates which were then enriched by solid phase extraction with C18 cartridge and eluted from the cartridge with tetrahydrofuran (THF). The chelates were separated on a Waters Xterra RP18 column by gradient elution with methanol (containing 0.05molL–1 pyrrolidine-acetic acid buffer salt, pH=10.0) and THF (containing 0.05molL–1 pyrrolidine-acetic acid buffer salt, pH=10.0) as mobile phase at a flow rate of 0.5mLmin–1 and detected with a photodiode array detector in the range of 350–600nm. In the original samples the detection limits of lead, cadmium, mercury, nickel, copper, zinc and tin are 4ngL–1, 3ngL–1, 6ngL–1, 5ngL–1, 2ngL–1, 6ngL–1, and 4ngL–1, respectively. This method was applied to the determination of lead, cadmium, mercury, nickel, copper, zinc and tin in Chinese herbal medicine samples with good results.  相似文献   

14.
A spectrophotometric method for the selective determination of Al(III) in the presence of Be and Ln (lanthanide) cations is proposed. It is based on the selective reaction of SXO (Semi-Xylenol Orange) with Al(III) at pH 2.6. The presence of 8%v/v of 1,2-ethanediol serves to stabilize the chelate formed by heating at 100°C for 5min. 0.5mg each of Be(II), Ce(III), La(III), 4mg of Mn(II), 1.2mg of Pb(II), 1mg of Tl(I), 40mg each of Ca(II) and Mg(II) and 1.9mg of sodium dihydrogen phosphate are tolerable. A ligand buffer of HEDTA-Pb is incorporated to further enhance the selectivity of the color reaction. Under the specified conditions SXO reacts with Al(III) to form a 1:1 chelate. Its molar absorptivity at 526nm was found to be 3.3×104Lmol–1cm–1. The linear regression equation for 2–20µg of Al(III) is A=0.04458C+0.0112 (where C stands for the concentration of Al(III), µg per 25mL) and correlation coefficient =0.9988. The RSD at the level of 10µg (n=10) and LOQ were found to be 3.5% and 2µg, respectively.  相似文献   

15.
Thallium in natural water samples was determined by electrothermal atomic absorption spectrometry after 1000-fold enrichment by mini solid-phase extraction from a 100-mL sample solution. A Tl-pyrrolidine-1-carbodithioate complex formed in a sample solution of pH 1.6 was extracted on fine particles of a cellulose nitrate resin dispersed in the sample solution. The cellulose nitrate resin was then collected on a membrane filter (25mmø) by filtration under suction using a glass funnel with an effective filtration area of 0.64cm2. As a result, a circular thin layer of the resin phase with a diameter of 9mm was obtained. Then the resin phase was carved out by an acrylate resin puncher with a 10-mmø hole to put it into a sample cup containing 100µL of 10mM HNO3 containing 0.5mM NaCl. The resin phase was suspended in the solution by ultrasonication. 1000-fold enrichment was thus attained within 15min, and the suspension was delivered to electrothermal atomic absorption spectrometry. The linear calibration graph was obtained in the range of 0–4ng of Tl in 100mL of a sample solution. The detection limit obtained by 3 method was 0.19ng. The proposed method was applied to the determination of Tl in natural water samples. The results showed the concentration of Tl in seawater was 12.1±1.8pgmL–1 for the calibration graph method and 12.6±1.4pgmL–1 for the standard addition method. A snowmelt sample contained 20.7±1.0pgmL–1 of Tl.  相似文献   

16.
The preconcentration of Au and Pd on Duolite GT-73 chelating resin with the thiol functional group was investigated prior to determination of these noble metals by means of inductively coupled plasma atomic emission spectrometry. It was found that AuIII and PdII were retained on the resin along with other concomitant metals (Al, Ca, Cd, Co, Cr, Cu, Fe, Mg, Mn, Ni, Pb and Zn) from different HCl-containing media. A two-step elution procedure was developed for the release of the noble metals. First 4.0molL–1 HNO3 solution was used to elute the base metals. The recovery of Au and Pd was performed afterwards using 0.50molL–1 solution of (NH2)2CS. Retrieval of Au and Pd retained on Duolite GT-73 was also carried out by decomposition of the resin in the open vessel system using H2SO4 with H2O2. The detection limits of Au and Pd evaluated for the devised protocol, with a preconcentration factor of 50, were 0.085µgL–1 and 0.28µgL–1, respectively. The proposed method was applied to the determination of Au and Pd in spiked electrolytic bath samples.  相似文献   

17.
A microcolumn on-line preconcentration and separation system was developed for the flame atomic absorption spectrometric (FAAS) determination of trace levels of gold and palladium. The analytes were selectively adsorbed onto the microcolumn packed with 2-mercaptothiazole immobilized silica gel (MBTSG) in an acidity range of 0.1 to 6.0M HCl at a sampling flow rate of 4.0mLmin–1. The analytes adsorbed could be desorbed by a thiourea solution with a flow rate of 2.0mLmin–1. Most of the common coexisting metal ions at a concentration of 25.0mgmL–1 and anions at a concentration of 50.0mgmL–1 did not interfere with the preconcentration and determination of Au and Pd. The limits of detection (LOD), defined as three times the standard deviation of the blank (3), of Au and Pd are 10ngmL–1 and 26ngmL–1, respectively, with a preconcentration time of 60s. The relative standard deviation (RSD) is about 2.0% for 0.20µgmL–1 Au and 0.30µgmL–1 Pd. With a sample loading time of 30min, 6.7ngmL–1 Au and 10ngmL–1 Pd can be preconcentrated quantitatively. A geological sample, an anode slime and a secondary nickel alloy were successfully determined with the proposed method, and the results obtained showed good agreement with the certified values.Received December 23, 2002; accepted May 14, 2003 Published online August 8, 2003  相似文献   

18.
An optical sensor for hydrogen peroxide (HP) based on the probe europium tetracycline (EuTc) incorporated into a polyacrylonitrile-co-polyacrylamide polymer matrix is described. Upon optical excitation with 400-nm light, the EuTc in the membrane displays fairly strong fluorescence peaking at 616nm. The fluorescence intensity increases up to 3-fold if the sensor is exposed to solutions containing HP. The effect is reversible and can thus be used for continuous sensing. The largest signal changes with HP are observed at pH levels between 6.5 and 7.5, and the range of the response is between 10 and 300ppm (w/w) of HP, equal to 0.3 to 10mmolL–1). At concentrations above 0.3% of HP, decomposition of the EuTc in the membrane is observed. The limit of detection is 15ppm (0.45mmolL–1). The response is fully reversible and rather slow (10min) in both directions, but the reverse response may be accelerated by addition of a reducing agent such as thiosulfate. Alkali ions and most anions remain inert, but phosphate and citrate interfere, as do Cu2+ ions, which quench fluorescence. In order to image the spatial distribution of HP concentrations, sensor membranes were placed on the bottom of the wells of a microtiter plate, and their fluorescence was imaged using an LED-based device based on the measurement of the luminescence decay time of EuTc. If glucose oxidase is immobilized on the sensor layer, a glucose sensor is obtained in which the HP sensor acts as the transducer and which can quantify glucose in concentrations between 0.1 and 5mmolL–1. The limit of detection for glucose is 0.2mmolL–1.  相似文献   

19.
A flow injection method including chemiluminescence detection has been developed and applied to the determination of fluoroquinolones levofloxacin, moxifloxacin and trovafloxacin in tablets. The proposed method is based on the luminescent properties of the system Ce(IV)–sulphite–fluoroquinolone and the addition of a trivalent lanthanide ion as emission-sensitizer. The optimum conditions for chemiluminescence emission were investigated for each fluoroquinolone. The best results were achieved when employing Eu(III) as lanthanide cation for levofloxacin and moxifloxacin, and Tb(III) for trovafloxacin. These fluoroquinolones were determined over the concentration range of 0.5–3.5µgmL–1, 0.2–3.0µgmL–1 and 0.008–0.400µgmL–1, with detection limits of 0.100, 0.035 and 0.008µgmL–1, respectively. The relative standard deviations were in the range of 1.0–2.5% for all three cases. The method was applied to the determination of three fluoroquinolones in their respective pharmaceutical preparations and compared with an independent UV-spectrophotometric method. The results were satisfactory.  相似文献   

20.
A simple and novel electrogenerated chemiluminescence (ECL) method for the determination of sulfite has been developed based on the energy transfer ECL process. It was found that a weak ECL signal of sulfite was electrochemically generated on a platinum electrode in neutral aqueous solution. The signal was strongly enhanced by rhodamine B as an energy receptor and further enhanced by the neutral surfactant Tween 80. In 0.10M phosphate buffer solution (pH=7.5) containing 2.0×10–6gmL–1 rhodamine B and 0.4% (v/v) Tween 80, the ECL response to the concentration of sulfite at a potential of 0.82V was linear over a range of 1.0×10–7gmL–1 to 8.0×10–6gmL–1, and the detection limit was 5×10–8gmL–1. The relative standard deviation (n=11, 1.0×10–6gmL–1) was 3.8%. The proposed method has been successfully applied to the determination of sulfite in pharmaceutical injections and white sugar samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号