首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Solid-phase nanoextraction is a sample preparation technique, which combines nanotechnology with analytical chemistry, and brings analytical chemistry to a higher level, particularly for complex system analysis. This paper describes a typical example of electrochemical solid-phase nanoextraction and electrochemical detection. Trace amounts of copper (5.0?×?10?13?mol/L) were extracted by electrochemical solid-phase nanoextraction on to the magnesium oxinate nanoparticle-modified carbon paste electrode surface in a pH?7.2 phosphate buffer system at ?0.50 V for 100 s. The extraction is achieved by the cation exchange between copper(II) in the aqueous solution and magnesium(II) from the magnesium oxinate nanoparticles on the electrode surface. The extracted copper shows an irreversible anodic peak at about 0.2 V (vs. saturated calomel electrode). The peak current is proportional to the scan rate, which shows this to be a surface-controlled process. The oxidation peak current is proportional to the logarithm of the copper concentration in the range 5.0?×?10?13?~?5.0?×?10?7?M with a slope of 2.215. This powerful method uses the carbon paste electrode to combine extraction with electrochemical analysis.  相似文献   

2.
《Analytical letters》2012,45(1):156-170
In this paper we have investigated the electrochemical activity of lanthanum chloride (La (III)) in the presence of calcon carboxylic acid (CCA) using a multi-walled carbon nano tube/carbon paste electrode (CNT/CPE). The peak current increases linearly with increasing of the La (III) concentration. For this purpose, a few electrochemical methods such as cyclic, differential pulse voltammetry, linear sweep and hydrodynamic voltammetry, and chronoamperometry were used. The results show that calcon carboxylic acid as a ligand was useful for determination of La (III) and was able to improve its sensitivity. Cyclic voltammetry was used for study of reduction reaction of La (III) at the surface of modified electrode. The electrochemical parameters for La (III) at the surface of CNT/CPE, such as diffusion coefficient (D/ cm2 s ?1 = 5.26 × 10?6), the electron transfer coefficient, (α = 0. 43), and the reduction rate constant, (k/ M s?1 = 2.33 (±0.015) × 102), were determined using voltammetry methods, which with the detection limit of La (III) by differential pulse voltammetry was found to be 1.3 nM. The combination of CCA with CNT as mediators in carbon paste electrode showed that this electrode is capable, sensitive, and simple to quantify La (III) in real samples with an average recovery of 97.64%.  相似文献   

3.
Zheng  Dongyun  Liu  Xiaojun  Zhu  Shanying  Cao  Huimin  Chen  Yaguang  Hu  Shengshui 《Mikrochimica acta》2015,182(15):2403-2410

We describe an electrochemical sensor for nitric oxide that was obtained by modifying the surface of a nanofiber carbon paste microelectrode with a film composed of hexadecyl trimethylammonium bromide and nafion. The modified microelectrode displays excellent catalytic activity in the electrochemical oxidation of nitric oxide. The mechanism was studied by scanning electron microscopy and cyclic voltammetry. Under optimal conditions, the oxidation peak current at a working voltage of 0.75 V (vs. SCE) is related to the concentration of nitric oxide in the 2 nM to 0.2 mM range, and the detection limit is as low as 2 nM (at an S/N ratio of 3). The sensor was successfully applied to the determination of nitric oxide released from mouse hepatocytes.

NO electrochemical sensor based on CTAB-Nafion/CNFPME was fabricated through a simple method and applied to detect NO released from mouse hepatocytes successfully.

  相似文献   

4.
《Analytical letters》2012,45(3):441-448
Abstract

An optical sensing membrane for detection of cationic surfactants was developed. The optical sensing membrane is 2‐nitrophenyl octyl ether‐plasticized poly(vinyl chloride) membrane incorporating tetrabromophenolphthalein ethyl ester (TBPE). The response of the optical membrane to cationic surfactants was a result of extraction of cationic surfactant into the PVC membrane. The protonated TBPE deprotonates forming an ion associate with the extracted cationic surfactant; simultaneously, the deprotonation of the TBPE is accompanied by a spectral change. Namely, the extracted cationic surfactant changes color of the membrane from yellowish green to blue (absorption maximum: 622 nm). The optical membrane responds to cationic surfactants such as Zephiramine and cetyltrimethylammonium bromide in the concentration range from 1 µM to 100 µM.  相似文献   

5.
A simple, sensitive aptamer-based biosensor for the detection of phenylalanine is developed using the electrochemical transduction method. For this proposed aptasensor, a 5-thiol-terminated aptamer is covalently attached onto a gold electrode. At the first time, the electrode was evaluated as an electrochemical aptasensor for determination of phenylalanine in aqueous solutions. This sensor was tested in a Tris–HCl buffer with physiological pH?=?7.4 by cyclic voltammetry and differential pulse voltammetry. The detection limit and sensitivity of the modified electrode toward phenylalanine were estimated to be 1 nM (S/N?=?3) and 0.367 μA nM?1, respectively. The linear range of the signal was observed between 1 and 10 nM of phenylalanine with 0.9914 correlation factor. The herein-described approach is expected to promote the exploitation of aptamer-based biosensors for protein assays in biochemical and biomedical studies.  相似文献   

6.
A novel electrochemical sensing platform was developed that is based on the modification of a glassy carbon electrode with acetylene black and ionic liquids. The resulting electrode exhibited excellent electrocatalytic activity towards trifluralin in showing markedly increased redox peak currents. The experimental parameters affecting the response to trifluralin were optimized. Under optimal conditions, a linear response was obtained in the range from 80 nM to 12 µM of trifluralin (R?=?0.9994). The detection limit is 10 nM (at S/N?=?3) after open-circuit accumulation for 120 s. The method was successfully applied to determine trifluralin in soil samples. Features such as a large electroactive area, fast electron transfer and low background current make this composite electrode a promising platform for fabricating reliable electrochemical sensors for various species.  相似文献   

7.
Three-dimensional interconnected network graphene foam (GF) was synthesized by chemical vapor deposition. The GF was transferred onto indium tin oxide glass, acting as an electrode for the selective determination of L-dopa in the presence of ascorbic and uric acid. Using differential pulse voltammetry (DPV) method, the oxidation peak current is well linear with L-dopa concentration in the range of 0.05–1 μM with a sensitivity of 2.64 μA μM?1 and in the range of 1–40 μM with a sensitivity of 1.82 μA μM?1. The detection limit of this electrode for L-dopa is about 20 nM. The proposed electrode can also effectively avoid the interference of ascorbic acid and uric acid, making the proposed sensor suitable for the accurate determination of L-dopa in human urine fluids. This electrode will have a wide range of potential application prospect in electrochemical detection.  相似文献   

8.
A sensitive electrochemical aptasensor was developed with conductive graphene served as platform and inert graphene oxide (GO) as enhancer. An electrodeposited nano-Au layer was firstly formed on conductive graphene modified glass carbon electrode surface for further immobilizing of electrochemical redox probe hexacyanoferrates nanoparticles (NiHCFNPs). Subsequently, another nano-Au layer was formed for immobilizing of thrombin aptamer (TBA). In the presence of thrombin, the TBA on the electrode surface could bind with thrombin, which made a barrier for electrons and inhibited the electro-transfer, resulting in the decreased electrochemical signals of NiHCFNPs. Owing to the non-conductivity property of graphene oxide, further decreased electrochemical signals of NiHCFNPs could be obtained via the sandwich reaction with GO-labeled TBA. According to the signal changes before the thrombin recognition and after sandwich reaction, trace detection of thrombin could be achieved. As a result, the proposed approach showed a high sensitivity and a wider linearity to thrombin in the range from 0.005 nM to 50 nM with a detection limit of 1 pM.  相似文献   

9.
《Analytical letters》2012,45(6):894-906
A reduced graphene oxide-modified glassy carbon electrode for sensitive detection of rutin is reported. The modified electrode was obtained by one-step electrochemical reduction of graphene oxide on the bare glassy carbon electrode. In the presence of graphene, an enhanced electrochemical response for rutin appeared with a pair of well-defined anodic and cathodic peaks in pH 3.0 phosphate buffer. Under the optimized conditions, the anodic peak currents exhibited a linear relationship with rutin concentration from 0.1 to 2.0 µM with a detection limit of 23.2 nM. The modified electrode was employed to the analysis of tablets (with satisfactory recovery of 19.96 mg/per tablet) and Flos Sophorae. The graphene-modified electrode exhibited high sensitivity, good stability, and selectivity for the determination of rutin.  相似文献   

10.
《Analytical letters》2012,45(14):2671-2685
Abstract

A high performance liquid chromatography (HPLC) method with electrochemical detection (ED) was developed for the determination of benzidine, 3,3‐dimethylbenzidine, o‐toluidine and 3,3‐dichlorobenzidine in the wastewater of the textile industry. The aromatic amines were eluted on a reversed phase column Shimadzu Shimpack C18 using acetonitrile+ammonium acetate (1×10?4 mol L?1) at a ratio 46:54 v/v as mobile phase, pumped at a flow rate of 1.0 mL min?1. The electrochemical oxidation of the aromatic amines exhibits well‐defined peaks at a potential range of +0.45 to +0.78 V on a glassy carbon electrode. Optimum working potentials for amperometric detection were from 0.70 V to +1.0 V vs. Ag/AgCl. Analytical curves for all the aromatic amines studied using the best experimental conditions present linear relationship from 1×10?8 mol L?1 to 1.5×10?5 mol L?1, r=0.99965, n=15. Detection limits of 4.5 nM (benzidine), 1.94 nM (o‐toluidine), 7.69 nM (3,3‐dimethylbenzidine), and 5.15 nM (3,3‐dichlorobenzidine) were achieved, respectively. The detection limits were around 10 times lower than that verified for HPLC with ultra violet detection. The applicability of the method was demonstrated by the determination of benzidine in wastewater from the textile industry dealing with an azo dye processing plant.  相似文献   

11.
We report on a glassy carbon electrode that was modified with a composite made from graphene oxide (GO) and multiwalled carbon nanotubes (MWCNT) that enables highly sensitive determination of L-tyrosine. The sensor was characterized by transmission electron microscopy and electrochemical impedance spectroscopy, and its electrochemical properties by cyclic voltammetry, chronocoulometry and differential pulse voltammetry. The GO/MWCNT hybrid exhibits strong catalytic activity toward the oxidation of L-tyrosine, with a well defined oxidation peak at 761 mV. The respective current serves as the analytical information and is proportional to the L-tyrosine concentration in two ranges of different slope (0.05 to 1.0 μM and 1.0 to 650.0 μM), with limits of detection and quantification as low as 4.4 nM and 14.7 nM, respectively. The method was successfully applied to the analysis of L-tyrosine in human body fluids. The excellent reproducibility, stability, sensitivity and selectivity are believed to be due to the combination of the electrocatalytic properties of both GO and MWCNT. They are making this hybrid electrode a potentially useful electrochemical sensing platform for bioanalysis.
Figure
A new L-tyrosine electrochemical sensor was fabricated based on graphene oxide and multiwalled carbon nanotube. The prepared sensor exhibits excellent electro-catalysis to the oxidation of L-tyrosine, and can improve determination sensitivity and decrease detection limit. This sensor was successfully applied to detect L-tyrosine in human fluids with satisfactory results.  相似文献   

12.
Polarographic determination of bromide at nanomolar levels. Application to the determination of bromide in blood and urine.Colorimetric methods for bromide determination lack adequate sensitivity for normal levels in biological fluids. A sensitive amplification process is recommended: bromide is oxidized to bromate with hypochlorite; after reaction between bromate and excess of bromide, the bromine formed is extracted into chloroform and then reduced to bromide by ammonia; these different steps can be repeated. Alternating current polarography of bromate allows selective evaluation in biological fluids. The detection limit is 10-6 M and can be reduced to 10-9 M with further amplification steps. The effects of iodide and of instrumental parameters are discussed.  相似文献   

13.
A simple but sensitive technique has been demonstrated towards the electroanalytical quantification of the strength of garlic. This technique can also be used to quantify dialkyldisulfides. The cyclic voltammetry of bromide was found to be a sensitive electrochemical probe, electrogenerated bromine reacting with dialkyldisulfides to catalytically regenerate bromide, resulting in a significant increase in peak current. A linear response of current vs. concentration was observed between 0.1 and 15 mM dipropyldisulfide at edge plane pyrolytic graphite (EPPG) electrodes; a smaller range up to ca. 5 mM was available at screen printed carbon electrodes (SPCEs), with a detection limit (from 3σ) of 0.067 mM. The response of diallyldisulfide was found to be essentially identical. Shaking garlic puree in acetonitrile for 5 minutes, followed by dilution with water then recording the voltammetry at the cheap, disposable SPCE gave a linear trend in current with respect to the quantity of garlic present, corresponding to the diallyldisulfide extracted. This has potential applications in monitoring the garlic content of medicinal supplements, batch-to-batch variation and the stability of garlic during storage.  相似文献   

14.
In this work, an electrochemical investigation of acebutolol (ACE), a beta-blocker drug, was carried out in alkaline medium using pencil graphite (PG) electrode. In cyclic voltammetry, the compound displayed a reversible and adsorption-controlled oxidation peak. By using square-wave anodic stripping voltammetry, the oxidation peak current observed at +0.78 V showed a linear relationship with concentration at 0.4–7 nM interval in Britton–Robinson buffer (pH 10.0) and a detection limit of 0.09 nM. The relative standard deviation of 4.72% for the concentration level of 2.0 nM (n = 11) was also calculated. The PG electrode that is used for the first time in this method was successfully applied to determine the ACE in pharmaceutical formulations and urine.  相似文献   

15.
An electrochemical sensor for simultaneous determination of dopamine (DA), uric acid (UA), guanine (G), and adenine (A) has been constructed by copolymerizing melamine monomer and Ag ions on a glassy carbon electrode (GCE) with cyclic voltammetry. The poly-melamine and nano Ag formed a hybridized film on the surface of the GCE. The morphology of the film was characterized by scanning electron microscope. The electrochemical and electrocatalytic properties of this film were characterized by cyclic voltammetry, linear sweep voltammetry, and square wave voltammetry (SWV). In 0.1 M phosphate buffer solution (pH 4.5), the modified electrode resolved the electrochemical response of DA, UA, G, and A into four well-defined voltammetric oxidation peaks by SWV; the oxidation peak current of DA, UA, G, and A increased 13-, 6-, 7-, and 9-fold, respectively, compared with those at the bare GCE and the SWV peak currents of DA, UA, G, and A with linear concentrations in the ranges of 0.1–50, 0.1–50, 0.1–50, and 0.1–60 μM, respectively. Based on this, a method for simultaneous determination of these species in mixture was setup. The detection limits were 10 nM for DA, 100 nM for UA, 8 nM for G, and 8 nM for A.  相似文献   

16.
We have developed a biosensor for highly sensitive and selective determination of the endocrinic disruptor bisphenol A (BPA). It is based on glassy carbon electrode modified with calf thymus DNA and a composited prepared from single walled carbon nanotubes (SWNT) and Nafion. The interaction between BPA and DNA was studied by voltammetry. The binding constant was determined to be 3.55?×?103 M?1, and the binding site has a length of 4.3 base pairs. These electrochemical studies provide further information for a better understanding of the toxicity and carcinogenicity of BPA. Under optimal conditions, the biosensor displays a linear electrochemical response to BPA in the 10 nM to 20 μM concentration range, with a detection limit as low as 5.0 nM (at an S/N of 3). The method was successfully applied to the quantification of BPA in leachates from plastic baby bottles. Recoveries range from 94.0 % to 106.0 % which underpins the excellent performance of this SWNT-based DNA sensor.
Figure
A biosensor based on DNA and single walled carbon nanotubes modified glassy carbon electrode displays a linear electrochemical response to bisphenol A in the 10 nM to 20 μM concentration range, with a detection limit as low as 5.0 nM (at an S/N of 3).  相似文献   

17.
《Analytical letters》2012,45(16):2665-2682
Abstract

The oxidation of theophylline was studied at a carbon paste electrode in the presence of cetyltrimethyl ammonium bromide by cyclic and differential pulse voltammetry. The results indicated that the electrochemical responses of theophylline are apparently improved by cetyltrimethyl ammonium bromide, due to the enhanced accumulation of theophylline at carbon paste electrode surface. Under optimal conditions the peak current was proportional to theophylline concentration in the range of 8.0 × 10?7 to 2.0 × 10?4 M with a detection limit of 1.85 × 10?7 M by differential pulse voltammetry. The proposed method was applied to the determination of theophylline in tablet and urine samples.  相似文献   

18.
The quantitative electrochemical generation of bromine at a platinum electrode in acetic acid is described. Coulometric methods for the determination of hydroquinone and 2-methylhydroquinone are reported. The best results are obtained with 0.7–1.1 M potassium acetate solutions as supporting electrolyte, and biamperometric end-point detection. The effects of water and acetic anhydride on the accuracy of titrations are discussed. Determination of the formal redox potential of the Br2/Br- system in a 0.9 M potassium acetate solution in acetic acid showed that bromide is oxidized directly to bromine at a platinum electrode with 100% current efficiency.  相似文献   

19.
A glassy carbon electrode was prepared that was coated with a composite film containing electropolymerized poly(amidosulfonic acid) and multi-walled carbon nanotubes. It was used to study the electrochemical response of procaine by differential pulse voltammetry. The results indicate that the electrode exhibits a remarkable improvement in the oxidation peak of procaine, and this led to a simple and sensitive method for the electroanalytical determination of procaine. The peak current is proportional to the concentration of procaine from 80 nM to 1.0 µM. The detection limit is 25 nM (S/N?=?3). The modified electrode was successfully applied to the direct determination of procaine in pharmaceutical formulations.  相似文献   

20.
We have developed a sensitive assay for enteropathogenic E. coli (EPEC) by integrating DNA extraction, specific polymerase chain reaction (PCR) and DNA detection using an electrode modified with the bundle-forming pilus (bfpA) structural gene. The PCR amplified products are captured on the electrode and hybridized with biotinylated detection probes to form a sandwich hybrid containing two biotinylated detection probes. The sandwich hybridization structure significantly combined the numerous streptavidin alkaline phosphatase on the electrode by biotin-streptavidin connectors. Electrochemical readout is based on dual signal amplification by both the sandwich hybridization structure and the enzyme. The electrode can satisfactorily discriminate complementary and mismatched oligonucleotides. Under optimal conditions, synthetic target DNA can be detected in the 1 pM to 10 nM concentration range, with a detection limit of 0.3 pM. EPEC can be quantified in the 10 to 107 CFU mL?1 levels within 3.5 h. The method also is believed to present a powerful platform for the screening of pathogenic microorganisms in clinical diagnostics, food safety and environmental monitoring.
An electrochemical DNA sensor was first designed to detect a bfpA gene specifically related to the EPEC.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏