首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 179 毫秒
1.
A rapid and reliable analytical method suitable for the simultaneous determination of the antiepileptic drug, oxcarbazepine and its metabolites in human plasma and saliva by means of liquid chromatography with diode array detection (DAD) has been developed. Oxcarbazepine and its metabolites (10,11-dihydro-10-hydroxycarbamazepine, trans-10,11-dihydro-10,11-dihydroxycarbamazepine and 3-hydroxycarbamazepine) were baseline separated within 6.5 min on a reversed-phase C18 column with a phosphate buffer-acetonitrile-triethylamine mixture as the mobile phase. The DAD detector was set at 240 nm. A sample preparation method for biological samples using a microextraction by packed sorbent technique has been implemented, employing a C18 sorbent inserted into a microvolume syringe and using only a small volume (25 μL) of plasma or saliva. The extraction yield values were satisfactory for all analytes (>86.5%) as well as the precision data, which were always in the low percentage of relative standard deviation values (<4.6%). The method was successfully applied to both plasma and saliva samples drawn from psychiatric and neurological patients undergoing treatment with oxcarbazepine (Tolep®) tablets.  相似文献   

2.
Eslicarbazepine acetate (BIA 2-093) is a novel central nervous system drug undergoing clinical phase III trials for epilepsy and phase II trials for bipolar disorder. A simple and reliable chiral reversed-phase HPLC-UV method was developed and validated for the simultaneous determination of eslicarbazepine acetate, oxcarbazepine, S-licarbazepine and R-licarbazepine in human plasma. The analytes and internal standard were extracted from plasma by a solid-phase extraction using Waters Oasis HLB cartridges. Chromatographic separation was achieved by isocratic elution with water-methanol (88:12, v/v), at a flow rate of 0.7 mL/min, on a LichroCART 250-4 ChiraDex (beta-cyclodextrin, 5 microm) column at 30 degrees C. All compounds were detected at 225 nm. Calibration curves were linear over the range 0.4-8 microg/mL for eslicarbazepine acetate and oxcarbazepine, and 0.4-80 microg/mL for each licarbazepine enantiomer. The overall intra- and interday precision and accuracy did not exceed 15%. Mean relative recoveries varied from 94.00 to 102.23% and the limit of quantification of the assay was 0.4 microg/mL for all compounds. This method seems to be a useful tool for clinical research and therapeutic drug monitoring of eslicarbazepine acetate and its metabolites S-licarbazepine, R-licarbazepine and oxcarbazepine.  相似文献   

3.
A rapid and sensitive ultraperformance liquid chromatography tandem mass spectrometry assay was developed for the simultaneous analysis of oxcarbazepine and its main metabolite in human plasma. The assay involves a simple solid‐phase extraction procedure of 0.3 mL of human plasma and analysis was performed on a triple‐quadrupole tandem mass spectrometer in multiple reaction monitoring mode via electrospray ionization. Separation was achieved on an Acquity UPLC™ BEH C18 column (50 × 2.1 mm, i.d., 1.7 µm) with isocratic elution at a flow‐rate of 0.25 mL/min and imipramine was used as the internal standard. The standard calibration curve was linear over the range 9.580–5070.205 ng/mL for oxcarbazepine (OXC) and 19.444–10290.800 ng/mL for 10,11‐dihydro‐10‐hydroxycarbamazepine (MHD), expressed by the linear correlation coefficient r2, which was better than 0.995 for OXC and MHD. The intra‐ and inter‐day precision and accuracy of the quality control samples were within 10.0%. The recoveries were 81.0, 89.6 and 66.6% for OXC, MHD and imipramine, respectively. The total run time was 1.5 min only for each sample, which makes it possible to analyze more than 350 samples per day. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

4.
A high-performance liquid chromatographic method with UV detection has been developed for the determination of saikosaponin a in rat plasma. Saikosaponin a and internal standard jujuboside A were isolated from plasma samples by solid-phase extraction. The chromatographic separation was achieved on a reversed-phase C(18) column with the mobile phase of acetonitrile-water (35:65, v/v) at a flow rate of 1 mL/min and UV detection was set at 205 nm. The standard curve for saikosaponin a was linear over the concentration range 0.25-10 microg/mL and the limit of detection was 0.05 microg/mL. The absolute recovery was greater than 82%. The precision and accuracy ranged from 3.05 to 9.59% and 95.61 to 110.00%, respectively. The validated method was used to determine saikosaponin a in plasma samples in a pharmacokinetic study of saikosaponin a administered to Sprague-Dawley rats.  相似文献   

5.
A liquid chromatographic method with diode array detection (DAD) has been developed for the analysis of the antiepileptic agent lamotrigine (LTG) and its metabolites, lamotrigine 2-N-glucuronide and 2-N-methylated in plasma samples. The analytes were separated on a C8 RP column, using a mobile phase composed of methanol and a 0.45 mM, pH 3.5 phosphate buffer containing 0.17% triethylamine (24:76 v/v). Melatonin was used as the internal standard (IS). The DAD detector was set at 220 nm for the detection of all the analytes. A simple protein precipitation with methanol guaranteed high extraction yield values (>90%) and good purification from matrix interference. Good linearity was obtained in the 0.1-15.0 microg/mL range for LTG and lamotrigine 2-N-glucuronide and in the 0.1-2.0 microg/mL range for lamotrigine 2-N-methylated. The analytical method was validated in terms of precision, extraction yield, and accuracy. These assays gave RSD% values for precision always lower than 4.3% and mean accuracy higher than 80%. The method seems to be suitable for the analysis of plasma samples from patients treated with Lamictal.  相似文献   

6.
A reliable micellar electrokinetic capillary chromatographic method was developed and validated for the determination of lamotrigine and its metabolites in human plasma and urine. The variation of different parameters, such as pH of the background electrolyte (BGE) and Sodium dodecyl sulfate (SDS) concentration, were evaluated in order to find optimal conditions. Best separation of the analytes was achieved using a BGE composed of 10 mM borate and 50 mM SDS, pH 9.5; melatonin was selected as the internal standard. Isolation of lamotrigine and its metabolites from plasma and urine was accomplished with an original solid-phase extraction procedure using hydrophilic-lypophilic balance cartridges. Good absolute recovery data and satisfactory precision values were obtained. The calibration plots for lamotrigine and its metabolites were linear over the 1-20 microg/mL concentration range. Sensitivity was satisfactory; the limits of detection and quantitation of lamotrigine were 500 ng/mL and 1 microg/mL, respectively. The application of the method to real plasma samples from epileptic patients under therapy with lamotrigine gave good results in terms of accuracy and selectivity, and in agreement with those obtained with an high-performance liquid chromatography (HPLC) method.  相似文献   

7.
A new, simple, and reproducible method for determination of carboxylic acid metabolite of clopidogrel in human plasma has been developed. After liquid-liquid extraction in acidic medium with chloroform, samples were quantified on a Nova-pak C(8), 5 microm column using a mixture of 30 mM K(2)HPO(4)-THF-acetonitrile (pH = 3, 79:2:19, v/v/v) as mobile phase with UV detection at 220 nm. The flow rate was set at 0.9 mL/min. Ticlopidine was used as internal standard and the total run time of analysis was about 12 min. The method was linear over the range of 0.2-10 microg/mL of clopidogrel metabolite in plasma (r(2) > 0.999). The within-day and between-day precision values were in the range 1.0-4.8%. The limit of quantification of the method was 0.2 microg/mL. The method was successfully used to study the pharmacokinetics of clopidogrel in healthy volunteers.  相似文献   

8.
A rapid, selective and sensitive UPLC‐UV method was developed and validated for the quantitative analysis of carbamazepine and its epoxide metabolite in rat plasma. A relatively small volume of plasma sample (200 μL) is required for the described analytical method. The method includes simple protein precipitation, liquid–liquid extraction, evaporation, and reconstitution steps. Samples were separated on a Waters Acquity UPLC BEH C18 column (1.7 µm, 2.1 × 100 mm) with a gradient mobile phase consisted of 60:40 going to 40:60 (v/v) water–acetonitrile at a flow rate of 0.5 mL/min. The total run time was as low as 6 min, representing a significant improvement in comparison to existing methods. Excellent linearity (r2 > 0.999) was achieved over a wide concentration range. Close to complete recovery, short analysis time, high stability, accuracy, precision and reproducibility, and low limit of quantitation were demonstrated. Finally, we successfully applied this analytical method to a pre‐clinical oral pharmacokinetic study, revealing the plasma profiles of both carbamazepine and carbamazepine‐10,11‐epoxide following oral administration of carbamazepine to rats. The advantages demonstrated in this work make this analytical method both time‐ and cost‐efficient approach for drug and metabolite monitoring in the pre‐clinical/clinical laboratory. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

9.
A sensitive method based on high-performance liquid chromatography (HPLC) with ultraviolet (UV) detection was developed for the determination of carbamazepine (CBZ) and one of its active metabolites, carbamazepine-10,11-epoxide (CBZ-E) in human plasma. CBZ, CBZ-E and the internal standard (IS) 10,11-dihydrocarbamazepine were extracted from human plasma into methyl tert-butyl ether. CBZ, CBZ-E and the IS were successfully separated on an RP C18 column with a mobile phase of acetonitrile:methanol:water (18:19:63, v/v/v) and monitored via UV detection at 210 nm. The calibration curves were linear over the concentration ranges of 0.01–10 μg/mL for CBZ and 0.005–5 μg/mL for CBZ-E in human plasma, respectively. The method displayed excellent sensitivity, precision and accuracy, and was successfully applied to the quantification of CBZ and CBZ-E in human plasma after oral administration of a single 200 mg CBZ CR tablet. This method is suitable for bioequivalence studies following single doses given to healthy volunteers.  相似文献   

10.
A simple and selective HPLC assay was developed and utilized for determination of human plasma protein binding of baicalin. The method involved solid-phase extraction and reversed-phase chromatographic separation with a mobile phase of acetonitrile-0.02 mol/L phosphate buffer (pH 2.5; 25:75, v/v) and UV detection at 276 nm. The standard curve for baicalin was linear over the concentration range 0.1-20 microg/mL and the limit of detection was 0.02 microg/mL. The absolute recovery was greater than 76%. The intra-day and inter-day variations were less than 10%. Ultrafiltration technique was applied to determining the plasma protein binding of baicalin in human plasma. Results show the plasma protein binding of baicalin was in the range 86-92% over all the concentrations studied and the protein binding association constant was determined to be 1.21 x 10(5) L/mol at 4 degrees C.  相似文献   

11.
A rapid and simple reversed-phase high-performance liquid chromatographic (RP-HPLC) method has been developed for determination of myrislignan in rat plasma after intravenous administration. The analytes extracted from plasma samples by solid-phase extraction were successfully carried out on a Diamonsiltrade mark ODS C(18) column (250 x 4.6 mm i.d., 5 microm) with an RP(18) guard column (8 x 4.6 mm i.d., 5 microm) and a mobile phase of MeOH-H(2)O (4:1, v/v). The UV detector was set at a single wavelength of 270 nm. The linear ranges of the standard curves were 0.5-30.0 microg/mL with the correlation coefficients greater than 0.9992. The lower limits of detection and quantification were 0.1 and 0.3 microg/mL for myrislignan. Intra- and inter-day precisions were 2.4-7.5 and 1.3-5.7%, respectively. The extraction recovery from plasma was more than 90%. This assay method has been successfully used to study the pharmacokinetics of myrislignan in rats.  相似文献   

12.
Yu LS  Xu XQ  Huang L  Ling JM  Chen GN 《Electrophoresis》2008,29(3):726-733
A selective and sensitive method of microemulsion EKC (MEEKC) with electrochemical detection (ED) was developed for separation and determination of 14 flavonoids. In order to obtain the better stability for the studied flavonoids, oil (ethyl acetate) with low interfacial surface tension was employed as organic solvent. A running buffer composed of 0.9% (w/v, 30 mM) SDS, 0.9% (w/v, 21 mM) sodium cholate (SC), 0.9% (w/v, 121 mM) butan-1-ol, 0.6% (w/v, 68 mM) ethyl acetate, and 98.2% v/v 10 mM Na(2)B(4)O(7)-20 mM H(3)BO(3) buffer (pH 7.5) was applied for the separation of flavonoids. Under the optimum conditions, the relationship between peak currents and analyte concentrations was linear over about 1.3 and 1.7 orders of magnitude with detection limits (defined as S/N = 3) ranging from 0.02 to 0.5 microg/mL for all analytes. This method was applied for the determination of flavonoids in real samples with simple extraction procedures, and the assay results were satisfactory.  相似文献   

13.
A rapid and simple high-performance liquid chromatographic method with photodiode array detection was developed for the separation and the simultaneous determination of phenytoin and dextromethorphan in human urine. Analysis was performed in less than 4.5 min in isocratic mode on a reversed-phase C18 column (5 microm; 150 x 4.6 mm) using a mobile phase composed of acetonitrile-buffer phosphate 0.01 M (60:40, v/v) adjusted to pH 6.0, at 1 mL/min flow rate and UV absorbance at 210 nm. The elution order of analytes was dextromethorphan (DXM), Internal Standard (IS), and phenytoin (PHT). Calibration curves were linear in the 7.5-25 microg/mL range for PHT and in the 10-30 microg/mL range for DXM. Spike recoveries for urine samples prepared at three spiking levels ranged from 97.8 to 102.3% for PHT and from 94.8 to 100.4% for DXM. The detection limit (LOD) values ranged from 0.08 microg/mL for PHT to 0.5 microg/mL for DXM. The quantitation limit (LOQ) values ranged from 0.3 microg/mL for PHT to 1.6 microg/mL for DXM. The sample preparation method involves a rapid and simple procedure based on solid-phase extraction using a C18 reversed-phase column. Validation of the optimised method was carried out according to the ICH guidelines. The method developed in this study allows the reliable simultaneous analysis of PHT and DXM, drugs that were never quantified together in previously reported analytical methods. The described method has the advantage of being rapid and easy and it could be applied in therapeutic monitoring of these drugs in human urine of epileptic patients.  相似文献   

14.
A simple HPLC method with ultraviolet detection has been developed and validated for the simultaneous determination of haplamine and its metabolites (trans/cis-3,4-dihydroxyhaplamine) in rat. A liquid-liquid extraction was used to extract the compounds from rat plasma. The analysis was performed on a C(18) Nucleosil Nautilus column. The mobile phase consisted of water (A) and a mixture of methanol and acetonitrile (85:15; v/v) (B) used in gradient mode (38-40% B for 10 min, 40-58% B for 49 min, 58-38% B for 1 min, and 38% for 5 min) pumped at 1 mL/min. The calibration curves showed good linearity with correlation coefficients greater than 0.999 for the analytes in the investigated concentration range. The lower limit of detection was 0.007, 0.008 and 0.009 microg/mL and the lower limit of quantification was 0.014, 0.017 and 0.018 microg/mL for haplamine, and trans/cis-3,4-dihydroxyhaplamine, respectively. The method was applied to a preliminary pharmacokinetic study in rats. This method proved to meet fully the standards required of experimental pharmacokinetic studies and should be used in further preclinical investigation.  相似文献   

15.
A simple and sensitive high-performance liquid chromatography (HPLC) method is developed and validated for simultaneous determination of pantoprazole and its two metabolites (pantoprazole sulfone and pantoprazole thioether) in dog plasma and applied to a pharmacokinetic study in Beagle dogs. Following a protein precipitation procedure, the samples are separated using reversed-phase HPLC (C18) by a gradient of acetonitrile and ammonium acetate (pH 6.0) at a flow rate of 1.0 mL/min and quantitated using UV detection at 290 nm. Omeprazole is selected as the internal standard. The method has a lower limit of quantitation of 0.025 microg/mL for pantoprazole and its two metabolites, using 0.1-mL aliquots of plasma. The linear calibration curves are obtained in the concentration range of 0.025-10.0 microg/mL for three analytes. The intra- and interrun precision (relative standard deviation), calculated from quality control (QC) samples, is less than 13% for three analytes. The accuracy determined from QC samples is between -6.4% and 12%.  相似文献   

16.
An isocratic reversed-phase high-performance liquid chromatographic method has been developed for separation and simultaneous determination of COX-2 inhibitors, viz., celecoxib, rofecoxib, valdecoxib, nimesulide and nabumetone, using 4-chloro-2-nitroaniline as internal standard. Good chromatographic separation was achieved using a reversed-phase Inertsil C(18) column with mobile phase consisting of methanol and 0.05% aqueous glacial acetic acid (68:32 v/v) using photodiode array (PDA) detector at 230 nm. It was validated with respect to accuracy, precision, linearity, limit of detection and quantification. The linearity range was found to be 1.0--20 microg/mL and the percentage recoveries were between 97.55 and 100.14. The method is suitable not only for the estimation of active ingredients in pharmaceutical dosage forms but also in vitro estimations in human plasma. It is simple, rapid, selective and capable of detecting and determining COX-2 inhibitors with a detection limit of 0.127--1.040 microg/mL simultaneously.  相似文献   

17.
A simple and reliable LC‐ESI‐MS method for the determination of peimine and peiminine in rat plasma was developed for the first time. The method was proven to be specific and sensitive by carrying out validation. The analytes were extracted from rat plasma via solid‐phase extraction on Waters Oasis MCX cartridges. Chromatography separation was achieved on a C18 column using 10 mM ammonium acetate (adjusted to pH 3.0 with glacial acetic acid)–acetonitrile (85:15, v/v) as mobile phase. The linear range was 1–100 ng/mL for peimine and peiminine. Intra‐ and inter‐day precisiond were less than 10%. Accuracies were within 85–115% of their nominal concentrations. The limit of quantification was 1 ng/mL for both analytes. The developed assay was successfully applied to pharmacokinetic study of peimine and peiminine in rats orally administered the alkaloids extracts from Bulbus Fritillariae, demonstrating a possible broader spectrum of applications of this method. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

18.
A solid‐phase extraction–liquid chromatographic–tandem mass spectrometry method for the determination of nalbuphine concentrations in human plasma has been developed. Samples (1 mL) were extracted using a Strata™‐X solid phase extraction cartridges. Chromatographic separation of nalbuphine and naloxone (internal standard) was achieved on a Phenomenex Kinetex PFP (2.6 μm, 100 A, 100 × 2.1 mm) column using a mobile phase consisting of 0.1% formic acid, 15 mM ammonium acetate in deionized water and acetonitrile (60:40, v/v). The flow rate was 0.3 mL/min and the total run time was 2 min. Detection of the analytes was achieved using positive ion electrospray ionization via multiple reactions monitoring mode. The mass transitions were m/z 358 → 340 for nalbuphine and m/z 328 → 310 for naloxone. The assay was linear over the concentration range 0.50–500.00 ng/mL, with correlation coefficients ≥0.995. The lower limit of quantitation was set at 0.5 ng/mL plasma based on an average signal‐to‐noise ratio of 44.79. The intra‐ and inter‐day precision was less than 8.07% in terms of relative standard deviation and accuracy ranged from 94.97 to 106.29% at all quality control levels. The method was applied successfully to determine nalbuphine concentrations in human plasma samples obtained from subjects receiving intravenous administration of nalbuphine. The method is rapid, sensitive, selective and directly applicable to human pharmacokinetic studies involving nalbuphine. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

19.
A validated reversed-phase high-performance liquid chromatographic (RP-HPLC) method was developed for the determination of bergenin in rat plasma. Bergenin in rat plasma was extracted with methanol, which also acted as a deproteinization agent. Chromatographic separation of bergenin was performed on a C(18) column, with a mobile phase of methanol-water (22:78, v/v) at a flow-rate of 0.8 mL/min and an operating temperature of 40 degrees C, and UV detection was set at 220 nm. The calibration curve was linear over the range 0.25-50 microg/mL (r = 0.9990) in rat plasma. The limit of quantification was 0.25 microg/mL using a plasma sample of 100 microL. The extraction recoveries were 83.40 +/- 6.02, 81.49 +/- 2.40 and 72.51 +/- 2.64% at concentrations of 0.5, 5 and 50 microg/mL, respectively. The intra-day and inter-day precision and accuracy were validated by relative standard deviation (RSD%) and relative error (RE%), which were in the ranges 3.74-9.91 and -1.6-8.0%. After intravenous administration to rats at the dose of 11.25 mg/kg, the plasma concentration-time curve of bergenin was best conformed to a two-compartment open model. The main pharmacokinetic parameters indicated that bergenin exhibited a wide distribution and moderate elimination velocity in rat.  相似文献   

20.
A rapid, sensitive and simple-to-operate high performance liquid chromatographic method for the simulataneous determination of oxcarbazepine, 10-hydroxycarbazepine and 10,11-dihydro-10,11-trans-dihydroxy-carbamazepine in plasma is described. The drug and its metabolites were extracted from plasma using commercially available reversed phase octadecylsilane bonded-silica columns (Bond Elut C18, 1 mL capacity). Chromatographic separation of oxcarbazepine and its metabolites was achieved using a mobile phase consisting of acetonitrile/methanol/water (13:25:62 by volume) at a flow rate of 1.2 mL/min in conjunction with a Waters Associates Nova-Pak C18 column. The analytical column, in Radial-Pak cartridge form, was used in combination with a LiChrospher 5 microns C18 guard column. By measuring the UV absorbance at 214 nm, plasma levels in the region of 50-100 ng/mL for the drug and its metabolites can be detected with only 100 microL of plasma. The method has been applied to pharmacokinetic studies of oxcarbazepine and its metabolites in children with epilepsy; preliminary pharmacokinetic findings in two patients at steady-state are presented.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号