首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Sample autofluorescence (fluorescence of inherent components of tissue and fixative-induced fluorescence) is a significant problem in direct imaging of molecular processes in biological samples. A large variety of naturally occurring fluorescent components in tissue results in broad emission that overlaps the emission of typical fluorescent dyes used for tissue labeling. In addition, autofluorescence is characterized by complex fluorescence intensity decay composed of multiple components whose lifetimes range from sub-nanoseconds to a few nanoseconds. For these reasons, the real fluorescence signal of the probe is difficult to separate from the unwanted autofluorescence. Here we present a method for reducing the autofluorescence problem by utilizing an azadioxatriangulenium (ADOTA) dye with a fluorescence lifetime of approximately 15 ns, much longer than those of most of the components of autofluorescence. A probe with such a long lifetime enables us to use time-gated intensity imaging to separate the signal of the targeting dye from the autofluorescence. We have shown experimentally that by discarding photons detected within the first 20 ns of the excitation pulse, the signal-to-background ratio is improved fivefold. This time-gating eliminates over 96 % of autofluorescence. Analysis using a variable time-gate may enable quantitative determination of the bound probe without the contributions from the background.  相似文献   

2.
In vivo fluorescence spectroscopy of nonmelanoma skin cancer   总被引:3,自引:0,他引:3  
In vivo and ex vivo tissue autofluorescence (endogenous fluorescence) have been employed to investigate the presence of markers that could be used to detect tissue abnormalities and/or malignancies. We present a study of the autofluorescence of normal skin and tumor in vivo, conducted on 18 patients diagnosed with nonmelanoma skin cancers (NMSC). We observed that both in basal cell carcinomas (BCC) and squamous cell carcinomas (SCC) the endogenous fluorescence due to tryptophan residues was more intense in tumor than in normal tissue, probably due to epidermal thickening and/or hyperproliferation. Conversely, the fluorescence intensity associated with dermal collagen crosslinks was generally lower in tumors than in the surrounding normal tissue, probably because of degradation or erosion of the connective tissue due to enzymes released by the tumor. The decrease of collagen fluorescence in the connective tissue adjacent to the tumor loci was validated by fluorescence imaging on fresh-frozen tissue sections obtained from 33 NMSC excised specimens. Our results suggest that endogenous fluorescence of NMSC, excited in the UV region of the spectrum, has characteristic features that are different from normal tissue and may be exploited for noninvasive diagnostics and for the detection of tumor margins.  相似文献   

3.
The measurement of low concentrations of fluorescent tracers in sections of tissue is theoretically possible using several microfluorimetric techniques but the sensitivity attainable can be greatly decreased if high levels of autofluorescence are emitted by tissue components. The effects of tissue-processing techniques on autofluorescence and tracer fluorescence intensities were investigated. Autofluorescence in sections of rabbit carotid artery and fluorescence from lissamine rhodamine B-labelled albumin in a model system were measured by densitometry. Autofluorescence intensities appeared to be related to the degree of cross-linking resulting from fixation of the tissue. Tissue fixed with formaldehyde or mercury (II) chloride had the lowest emission. Fluorescence from the labelled albumin was not quenched by prolonged fixation with mercury (II) chloride and formaldehyde but extracting the “mercury pigment” from sections with alcoholic iodine resulted in a 34% decrease in intensity.  相似文献   

4.
The diagnostic ability of optical spectroscopy techniques, including near-infrared (NIR) Raman spectroscopy, NIR autofluorescence spectroscopy and the composite Raman and NIR autofluorescence spectroscopy, for in vivo detection of malignant tumors was evaluated in this study. A murine tumor model, in which BALB/c mice were implanted with Meth-A fibrosarcoma cells into the subcutaneous region of the lower back, was used for this purpose. A rapid-acquisition dispersive-type NIR Raman system was employed for tissue Raman and NIR autofluorescence spectroscopic measurements at 785-nm laser excitation. High-quality in vivo NIR Raman spectra associated with an autofluorescence background from mouse skin and tumor tissue were acquired in 5 s. Multivariate statistical techniques, including principal component analysis (PCA) and linear discriminant analysis (LDA), were used to develop diagnostic algorithms for differentiating tumors from normal tissue based on their spectral features. Spectral classification of tumor tissue was tested using a leave-one-out, cross-validation method, and the receiver operating characteristic (ROC) curves were used to further evaluate the performance of diagnostic algorithms derived. Thirty-two in vivo Raman, NIR fluorescence and composite Raman and NIR fluorescence spectra were analyzed (16 normal, 16 tumors). Classification results obtained from cross-validation of the LDA model based on the three spectral data sets showed diagnostic sensitivities of 81.3%, 93.8% and 93.8%; specificities of 100%, 87.5% and 100%; and overall diagnostic accuracies of 90.6%, 90.6% and 96.9% respectively, for tumor identification. ROC curves showed that the most effective diagnostic algorithms were from the composite Raman and NIR autofluorescence techniques.  相似文献   

5.
Fluorescence spectroscopy has potential to improve cervical precancer detection. The relationship between tissue biochemistry and fluorescence is poorly understood. The goal of this study was to characterize normal cervical autofluorescence, using fresh tissue short-term tissue cultures and epithelial cell suspensions. Transverse, short-term tissue cultures were prepared from 31 cervical biopsies; autofluorescence images were obtained at 380 and 460 nm excitation. Fluorescence excitation-emission matrices were measured from normal, precancerous and cancerous cervical cell suspensions. Observed fluorescence patterns contrast those reported for frozen-thawed tissue, and were placed into groups with (1) bright epithelial and weak stromal fluorescence; (2) similar epithelial and stromal fluorescence; and (3) weak epithelial and bright stromal fluorescence. The average ages of women in the groups were 30.9, 38.0 and 49.2 years. Epithelial fluorescence intensity was similar in Groups 1 and 2, but weaker in Group 3. Stromal intensity was similar in Groups 2 and 3, but weaker in Group 1. The ratio of epithelial to stromal fluorescence intensity was significantly different for all groups. EEMs of cell suspensions showed peaks consistent with tryptophan, reduced form of nicotinamide adenine dinucleotide (phosphate) and flavin adenine dinucleotide. Short-term tissue cultures represent a novel, biologically appropriate model to understand cervical autofluorescence. Our results suggest a biological basis for the increased fluorescence seen in older, postmenopausal women.  相似文献   

6.
Near-infrared (NIR) fluorescence probes are especially useful for simple and noninvasive in vivo imaging inside the body because of low autofluorescence and high tissue transparency in the NIR region compared with other wavelength regions. However, existing NIR fluorescence probes for matrix metalloproteinases (MMPs), which are tumor, atherosclerosis, and inflammation markers, have various disadvantages, especially as regards sensitivity. Here, we report a novel design strategy to obtain a NIR fluorescence probe that is rapidly internalized by free diffusion and well retained intracellularly after activation by extracellular MMPs. We designed and synthesized four candidate probes, each consisting of a cell permeable or nonpermeable NIR fluorescent dye as a F?rster resonance energy transfer (FRET) donor linked to the NIR dark quencher BHQ-3 as a FRET acceptor via a MMP substrate peptide. We applied these probes for detection of the MMP activity of cultured HT-1080 cells, which express MMP2 and MT1-MMP, by fluorescence microscopy. Among them, the probe incorporating BODIPY650/665, BODIPY-MMP, clearly visualized the MMP activity as an increment of fluorescence inside the cells. We then applied this probe to a mouse xenograft tumor model prepared with HT-1080 cells. Following intratumoral injection of the probe, MMP activity could be visualized for much longer with BODIPY-MMP than with the probe containing SulfoCy5, which is cell impermeable and consequently readily washed out of the tissue. This simple design strategy should be applicable to develop a range of sensitive, rapidly responsive NIR fluorescence probes not only for MMP activity, but also for other proteases.  相似文献   

7.
FLUORESCENCE SPECTRA IN LUNG WITH PORPHYRIN INJECTION   总被引:2,自引:0,他引:2  
The fluorescence emission spectra from human bronchial mucosa and tumors, before and after injection of dihematoporphyrin ether/ester, have been measured with an optical multichannel analyzer from 500 to 750 nm. Fluorescence was excited with a violet krypton ion laser (average wavelength 410 nm). The autofluorescence spectra decrease monotonically with increasing wavelength except for a small broad peak near 600 nm. The spectra from tumor sites, after injection of the fluorescent porphyrin, exhibit the characteristic fluorescence emission at 630 and 690 nm, added to the autofluorescence spectrum. The spectra from control or nontumor sites are similar but the magnitude of the component due to the injected porphyrin is smaller than at a tumor site. The magnitude ratio of tumor to control site fluorescence depends on concentration of the porphyrin, tumor thickness, and time after injection. Autofluorescence degrades contrast and thus makes very thin tumors difficult to image. Subtraction of the autofluorescence background is desirable.  相似文献   

8.
郝颖  王荣  尹强  谢华  李文斌  贾正平 《色谱》2013,31(10):1005-1009
胃癌是临床常见的恶性肿瘤之一。近年来寻找肿瘤相关特异蛋白质是蛋白质组学研究的热点。本文通过考察毛细管动态涂层方法、筛分介质聚环氧乙烷(PEO)的浓度、缓冲液的pH值、分离电压、温度及荧光染料对分离效果的影响,建立了毛细管电泳-激光诱导荧光法分离胃癌组织及癌旁正常组织蛋白质的方法;通过分离检测,获得两者的蛋白质指纹图谱。经分析,两者的指纹图谱相似度达到0.8以上,差异蛋白质分子质量集中在50000~100000 Da之间,提示某些小分子蛋白质可能是和肿瘤发生相关的特异蛋白质,从而缩小了特异性分子标记物的筛选范围。病理组织学分型及蛋白质电泳峰数目的统计结果验证了该方法的可靠性。该方法具有临床应用的潜力。  相似文献   

9.
The autofluorescence properties of normal human skin in the near-infrared (NIR) spectral range were studied using Monte Carlo simulation. The light-tissue interactions including scattering, absorption and anisotropy propagation of the regenerated autofluorescence photons in the skin tissue were taken into account in the theoretical modeling. Skin was represented as a turbid seven-layered medium. To facilitate the simulation, ex vivo NIR autofluorescence spectra and images from different skin layers were measured from frozen skin vertical sections to define the intrinsic fluorescence properties. Monte Carlo simulation was then used to study how the intrinsic fluorescence spectra were distorted by the tissue reabsorption and scattering during in vivo measurements. We found that the reconstructed model skin spectra were in good agreement with the measured in vivo skin spectra from the same anatomical site as the ex vivo tissue sections, demonstrating the usefulness of this modeling. We also found that difference exists over the melanin fluorescent wavelength range (880-910 nm) between the simulated spectrum and the measured in vivo skin spectrum from a different anatomical site. This difference suggests that melanin contents may affect in vivo skin autofluorescence properties, which deserves further investigation.  相似文献   

10.
Folate receptors (FRs) are membrane proteins involved in folic acid uptake, and the alpha isoform (FR‐α) is overexpressed in ovarian and endometrial cancer cells. For fluorescence imaging of FRs in vivo, the near‐infrared (NIR) region (650–900 nm), in which tissue penetration is high and autofluorescence is low, is optimal, but existing NIR fluorescent probes targeting FR‐α show high non‐specific tissue adsorption, and require prolonged washout to visualize tumors. We have designed and synthesized a new NIR fluorescent probe, FolateSiR‐1 , utilizing a Si‐rhodamine fluorophore having a carboxy group at the benzene moiety, coupled to a folate ligand moiety through a negatively charged tripeptide linker. This probe exhibits very low background fluorescence and afforded a tumor‐to‐background ratio (TBR) of up to 83 in FR‐expressing tumor‐bearing mice within 30 min. Thus, FolateSiR‐1 has the potential to contribute to the research in the field of biology and the clinical medicine.  相似文献   

11.
We present in vivo fluorescent, near-infrared (NIR), reflectance images of indocyanine green (ICG) and carotene-conjugated 2-devinyl-2-(1-hexyloxyethyl) pyropheophorbide (HPPH-car) to discriminate spontaneous canine adenocarcinoma from normal mammary tissue. Following intravenous administration of 1.0 mg kg-1 ICG or 0.3 mg kg-1 HPPH-car into the canine, a 25 mW, 778 nm or 70 mW, 660 nm laser diode beam, expanded by a diverging lens to approximately 4 cm in diameter, illuminated the surface of the mammary tissue. Successfully propagating to the tissue surface, ICG or HPPH-car fluorescence generated from within the tissue was collected by an image-intensified, charge-coupled device camera fitted with an 830 or 710 nm bandpass interference filter. Upon collecting time-dependent fluorescence images at the tissue surface overlying both normal and diseased tissue volumes, and fitting these images to a pharmacokinetic model describing the uptake (wash-in) and release (wash-out) of fluorescent dye, the pharmacokinetics of fluorescent dye was spatially determined. Mapping the fluorescence intensity owing to ICG indicates that the dye acts as a blood pool or blood persistent agent, for the model parameters show no difference in the ICG uptake rates between normal and diseased tissue regions. The wash-out of ICG was delayed for up to 72 h after intravenous injection in tissue volumes associated with disease, because ICG fluorescence was still detected in the diseased tissue 72 h after injection. In contrast, HPPH-car pharmacokinetics illustrated active uptake into diseased tissues, perhaps owing to the overexpression of LDL receptors associated with the malignant cells. HPPH-car fluorescence was not discernable after 24 h. This work illustrates the ability to monitor the pharmacokinetic delivery of NIR fluorescent dyes within tissue volumes as great as 0.5-1 cm from the tissue surface in order to differentiate normal from diseased tissue volumes on the basis of parameters obtained from the pharmacokinetic models.  相似文献   

12.
Although histochemical and immunohistochemical methods are the standard procedures in diagnosis of lymphoproliferative disorders, useful improvements in evidencing histopathologic manifestations can be obtained with the introduction of tissue autofluorescence analyses. We used microspectrofluorometry and a Multispectral Imaging Autofluorescence Microscopy (MIAM) technique to analyze lymph-node biopsies from patients with lymphoadenopathy of different origins. Images of tissue autofluorescence were obtained by excitation at 365 nm of lymph-node sections and sequential detection with interference filters (50 nm bandwidth) peaked at 450, 550 and 658 nm. Monochrome images were combined together in a single red-green-blue color image. Most of the fluorescence was observed within the blue spectral band because of large contributions from extracellular collagen and elastin fibers as well as from reduced form of intracellular nicotinamide adenine dinucleotide (phosphate). Autofluorescence imaging shows morphological differences between neoplastic and non-neoplastic tissues. The reactive hyperplasia samples show the typical lymph-node organization with weak fluorescent follicles separated by high fluorescent connective trabeculae. In the neoplastic lymph nodes the loss of follicle organization is observed. Consequently, MIAM permits to discriminate between non-neoplastic and neoplastic tissues on the basis of their autofluorescence pattern. Multispectral imaging of tissue autofluorescence may present some advantages with respect to standard histochemical microscopy since it (1) does not require any chemical manipulation of samples; (2) gives real-time results performing the analysis immediately upon specimen resection; and (3) supplies a representation of the biological structure organization linked to endogenous fluorophores.  相似文献   

13.
To improve optical imaging of Ca(2+) and to make available a distinct color window for multicolor imaging, we designed and synthesized CaSiR-1, a far-red to near-infrared fluorescence probe for Ca(2+), using Si-rhodamine (SiR) as the fluorophore and the well-known Ca(2+) chelator BAPTA. This wavelength region is advantageous, affording higher tissue penetration, lower background autofluorescence, and lower phototoxicity in comparison with the UV to visible range. CaSiR-1 has a high fluorescence off/on ratio of over 1000. We demonstrate its usefulness for multicolor fluorescence imaging of action potentials (visualized as increases in intracellular Ca(2+)) in brain slices loaded with sulforhodamine 101 (red color; specific for astrocytes) that were prepared from transgenic mice in which some neurons expressed green fluorescent protein.  相似文献   

14.
Laser-induced fluorescence of pheophorbide a (Ph- a ) was used for in vitro photodynamic imaging (PDI) of a rat pancreatic acinar tumor. A 400 nm excitation induced a 470 nm autofluorescence and a 678 nm dye fluorescence in tumors and their surrounding pancreas 24 h after a 9 mg kg−1 body weight Ph- a intravenous administration. With lower intensities in these blood-rich tumors than in pancreas, Ph- a fluorescence signals are unable to provide tumor images. A dimensionless function (the ratio of Ph- a fluorescence by autofluorescence, called Rt for the tumor and Rp for the pancreas) was used for fluorescence contrast calculation (C = Rt/Rp) between six tumors and their paired pancreas. Among five available laser excitation wavelengths, only the 355 nm excitation gave a distinctive contrast (C = 1.5). The PDI of six intrapancreatic tumors and their intraperitoneal metastasis and of two control normal pancreas was thus performed ex vivo using a 355 nm excitation source delivered by a tripled Nd: YAG laser and a charged-coupled device camera. Fluorescence images were recorded at 680 nm (dye), 640 nm (background) and 470 nm (autofluorescence) through three corresponding 10 nm width bandpass filters. Computed division for each pixel of Ph- a fluorescence values by autofluorescence generated false color image. In this way, contrasted tumor images were obtained. But in five out of six animals false-positive images were present due to an autofluorescence decrease in some normal pancreatic areas. A 470 nm autofluorescence imaging on the same tumors gave in all cases false-positive image and false-negative in half of the cases. These observations suggest that autofluorescence alone is unable to achieve accurate PDI of pancreatic carcinoma and that using Ph- a as a PDI dye needs strong improvements.  相似文献   

15.
To evaluate the new, bio-optical method of light-induced autofluorescence spectroscopy for the endoscopic in-vivo diagnosis of (pre)-cancerous lesions of the colorectum, 311 endogenous fluorescence spectra were obtained from normal, adenomatous and cancerous colorectal tissue in 11 patients with cancer, six patients with familial adenomatous polyposis, and six patients with multiple adenomatous polyps. A light source delivered either white or violet-blue light for excitation of tissue autofluorescence via a flexible endoscope. Endogenous fluorescence spectra emitted by the tissue were picked up with a fiberoptic probe and analysed with a spectrograph. Biopsies were taken for definitive classification of the spectra. Rectal cancer (n=11) as well as adenomas with severe dysplasia (n=19) showed specific differences between the emitted fluorescence spectra as compared with normal mucosa and hyperplastic polyps. Having applied a mathematical algorithm to the spectra, a sensitivity of 96% and a specificity of 93% were obtained for the diagnosis of rectal cancer. The equivalent values for the diagnosis of dysplastic ademomas were 98 and 89%, respectively. Light-induced autofluorescence spectroscopy is a new and promising bio-optical procedure for the endoscopic in-vivo diagnosis of colorectal cancer and dysplasia.  相似文献   

16.
Fluorescent markers emitting in the red are extremely valuable in biological microscopy since they minimize cellular autofluorescence and increase flexibility in multicolor experiments. Novel rhodamine dyes excitable with 630 nm laser light and emitting at around 660 nm have been developed. The new rhodamines are very photostable and have high fluorescence quantum yields of up to 80 %, long excited state lifetimes of 3.4 ns, and comparatively low intersystem‐crossing rates. They perform very well both in conventional and in subdiffraction‐resolution microscopy such as STED (stimulated emission depletion) and GSDIM (ground‐state depletion with individual molecular return), as well as in single‐molecule‐based experiments such as fluorescence correlation spectroscopy (FCS). Syntheses of lipophilic and hydrophilic derivatives starting from the same chromophore‐containing scaffold are described. Introduction of two sulfo groups provides high solubility in water and a considerable rise in fluorescence quantum yield. The attachment of amino or thiol reactive groups allows the dyes to be used as fluorescent markers in biology. Dyes deuterated at certain positions have narrow and symmetrical molecular mass distribution patterns, and are proposed as new tags in MS or LC‐MS for identification and quantification of various substance classes (e.g., amines and thiols) in complex mixtures. High‐resolution GSDIM images and live‐cell STED‐FCS experiments on labeled microtubules and lipids prove the versatility of the novel probes for modern fluorescence microscopy and nanoscopy.  相似文献   

17.
Biomaterials for in vivo fluorescence imaging are required to be biocompatible, nontoxic, photostable and highly fluorescent. Fluorescence must be in the near infrared (NIR) region of the electromagnetic spectrum to avoid absorption and autofluorescence of endogenous tissues. NIR fluorescent polystyrene nanoparticles may be considered ideal biomaterials for in vivo imaging applications. These NIR nanoparticles were prepared by a swelling process of polystyrene template nanoparticles with a hydrophobic NIR dye dissolved in a water‐miscible swelling solvent, a method developed for preparation of nonbiodegradable nanoparticles, for NIR fluorescent bioimaging applications. This method overcomes common problems that occur with dye entrapment during nanoparticle formation such as loss of fluorescence and size polydispersity. Fluorescence intensity of the nanoparticles was found to be size dependent, and was optimized for differently sized nanoparticles. The resulting NIR nanoparticles were also found to be more fluorescent and highly photostable compared to the free dye in solution, showing their potential as biomaterials for in vivo fluorescence imaging.  相似文献   

18.
Laser-induced fluorescence (LIF) of pheophorbide-a (Ph-a) was used for imaging of a rat pancreatic tumor. Using a dimensionless function (the ratio of Ph-a fluorescence by bluish autofluorescence), the fluorescence contrasts between excised tumors and their paired pancreas were investigated up to 48 h after a 9 mg kg-1 Ph-a intravenous administration. Among five tested excitation wavelengths, 355 and 610 nm excitations gave the best distinctive contrasts, both 48 h after dye injection. The LIF imaging of six intrapancreatic tumors and six healthy pancreas was carried out in vivo using two laser excitations: 355 nm (Nd:YAG + tripling) for bluish autofluorescence and 610 nm (rhodamine 6G dye) for reddish autofluorescence and dye emission. Images were recorded through bandpass filters at 470 and 640 nm (autofluorescence) and at 680 nm (dye + autofluorescence) with an intensified charged-coupled device camera. Autofluorescence as Ph-a fluorescence images did not allow accurate LIF diagnosis of pancreatic carcinoma. An image processing, including for each pixel a computed division of Ph-a fluorescence (after subtraction of reddish autofluorescence) by bluish autofluorescence intensity generated poorly contrasted tumor images in five of six and false tumor localization in one of three of the tumor-bearing pancreas. A fitting of the digital 640 nm autofluorescence up to the mean 680 nm fluorescence intensity in pancreas prior to subtraction allowed a safe diagnosis to be made with well-contrasted tumor images. To assess automation ability of the processing, a same fitting coefficient (mean of individual values) was applied. In this way, false-negative (one of six) and false-positive (two of six) images were present in tumor-bearing animals as false-positive in one-half of the controls. A successful standardized procedure was then applied with a normalization of 640 and 680 nm pancreas intensities to a same set threshold prior processing. In opposition to thin-layered hollow organs, such as bronchial tube or digestive tract, LIF imaging of carcinoma inserted in a compact organ is exhausting. The use of a dye excitable in the red wavelength range (610 nm for Ph-a) may partly solve this problem, rendering LIF imaging more accurate and potentially automated.  相似文献   

19.
Spectrally resolved fluorescence imaging of human colonic adenomas   总被引:2,自引:0,他引:2  
Native fluorescence (autofluorescence) of human tissues can be a valuable source of diagnostic information for detecting premalignant and malignant lesions in the human body. Digital imaging of autofluorescence may be useful for localization of such lesions during endoscopic examinations. Tissue fluorescence of 31 adenomatous polyps obtained from 16 patients has been excited in vitro using the 325 nm line of a He-Cd laser. Digital images of the autofluorescence are recorded in six spectral bands. This study provides new data about the spatial distributions of autofluorescence intensities emitted in different spectral bands by colonic adenomatous lesions and normal colonic mucosa. Areas characterized by autofluorescence intensity lower than in normal mucosa are found for a majority of the polyps under study. The observed patterns of spatial distribution differ for the different spectral bands and for different polypoid lesions. No inverse correlation is found between the emission intensity and the thickness of colonic mucosa. The results indicate the spectral bands most useful for diagnostic applications and demonstrate the complexity of the optical processes involved in shaping both the spectra and intensities of the autofluorescence.  相似文献   

20.
Infrared (IR) spectroscopy provides a sensitive molecular fingerprint for tissue without external markers. Supervised classification models can be trained to identify the tissue type based on the spectroscopic fingerprint. Infrared imaging spectrometers equipped with multi-channel detectors combine the spectral and spatial information. Tissue areas of 4 x 4 mm(2) can be analyzed within a few minutes in the macroscopic imaging mode. An approach is described to apply this methodology to human astrocytic gliomas, which are graded according to their malignancy from one to four. Multiple IR images of three tissue sections from one patient with a malignant glioma are acquired and assigned to the six classes normal brain tissue, astrocytoma grade II, astrocytoma grade III, glioblastoma multiforme grade IV, hemorrhage, and other tissue by a linear discriminant analysis model which was trained by data from a single-channel detector. Before the model is applied here, the spectra are shown to be virtually identical. The first specimen contained approximately 95% malignant glioma regions, that means astrocytoma grade III or glioblastoma. The smaller percentage of 12-34% malignant glioma in the second specimen is consistent with its location at the tumor periphery. The detection of less than 0.2% malignant glioma in the third specimen points to a location outside the tumor. The results were correlated with the cellularity of the tissue which was obtained from the histopathologic gold standard. Potential applications of IR spectroscopic imaging as a rapid tool to complement established diagnostic methods are discussed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号