首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 390 毫秒
1.
The use of slurry sampling total reflection X-ray fluorescence spectrometry (SlS-TXRF) for the direct determination of Ca, Cr, Cu, Fe, Mn and Ti in four boron nitride powders has been described. Measurements of the zeta potential showed that slurries with good stabilities can be obtained by the addition of polyethylenimine (PEI) at a concentration of 0.1 wt.% and by adjusting the pH at 4. For the optimization of the concentration of boron nitride in the slurries the net line intensities and the signal to background ratios were determined for the trace elements Ca and Ti as well as for the internal standard element Ga in the case of concentrations of boron nitride ranging from 1 to 30 mg mL1. As a compromise with respect to high net line intensities and high signal to background ratios, concentrations of 5 mg mL1 of boron nitride were found suitable and were used for all further measurements. The limits of detection of SlS-TXRF for the boron nitride powders were found to range from 0.062 to 1.6 μg g– 1 for Cu and Ca, respectively. Herewith, they are higher than those obtained in solid sampling and slurry sampling graphite furnace atomic absorption spectrometry (SoS-GFAAS, SlS-GFAAS) as well as those of solid sampling electrothermal evaporation inductively coupled plasma optical emission spectrometry (SoS-ETV-ICP-OES). For Ca and Fe as well as for Cu and Fe, however, they were found to be lower than for GFAAS and for ICP-OES subsequent to wet chemical digestion, respectively. The universal applicability of SlS-TXRF to the analysis of samples with a wide variety of matrices could be demonstrated by the analysis of certified reference materials such as SiC, Al2O3, powdered bovine liver and borate ore with a single calibration. The correlation coefficients of the plots for the values found for Ca, Fe and Ti by SlS-TXRF in the boron nitride powders as well as in the before mentioned samples versus the reference values for the respective samples over a concentration range from 2.5 to 1470 μg g– 1 were found to be 0.995, 0.991 and 0.997, respectively.  相似文献   

2.
A low pressure microwave assisted vapor phase dissolution procedure for silicon nitride and volatilization of in situ generated SiF4 has been developed using H2SO4, HF and HNO3 for the determination of trace impurities present in silicon nitride. Sample was taken in minimum amount (0.5 mL for 100 mg) of H2SO4 and treated with vapors generated from HF and HNO3 mixture in presence of microwaves in a closed container. An 80 psi pressure with ramp and hold times of 30 min and 60 min respectively, operated twice, resulted in 99.9% volatilization of Si. Matrix free solutions were analyzed for impurities using DRC-ICP-MS. The recoveries of Cr, Mn, Fe, Ni, Co, Cu, Zn, Sr, Y, Cd, Ba and Pb were between 80 and 100% after volatilization of Si. The blanks were in lower ng g−1 with method detection limits in lower ng g−1 to sub ng g−1 range. The method was applied for the analysis of two silicon nitride samples.  相似文献   

3.
In this work, the possibilities of solid sampling-graphite furnace atomic absorption spectrometry for the direct determination of silver in solid samples of very different nature (a biological sample, a soil, an ore concentrate and a polymer) and showing substantial differences in their analyte content (from approximately, 40 ng g−1 up to 350 μg g−1) have been evaluated, the goal always being to develop fast methods, only relying on the use of aqueous standards for calibration.Different factors had to be taken into account in order to develop suitable procedures for all the samples under investigation. Among the most important ones, the following can be mentioned: (i) optimization of the temperature program in order to selectively atomize the analyte; (ii) the use of chemical modifiers (such as Pd or HNO3), depending on the sample characteristics; (iii) appropriate wavelength, argon flow and sample mass selection (depending on the analyte content); (iv) the use of 3-field mode Zeeman-effect background correction in order to further expand the linear range up to 1000 ng of Ag, which was needed for analysis of the sample showing the highest Ag content (polypropylene).The procedures finally proposed show interesting features for the determination of silver in solid samples: the advantage of using aqueous standard solutions for calibration, a high sample throughput (approximately, 15 min per sample), a low detection limit (2 ng g−1), sufficient precision (R.S.D. values in the vicinity of 10%) and a reduced risk of analyte losses and contamination.  相似文献   

4.
Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) was used for quantitative imaging of selected elements (P, S, Fe, Cu, Zn and C) in thin sections of rat brain samples (thickness 20 μm). The sample surface was scanned (raster area ~ 2 cm2) with a focused laser beam (wavelength 266 nm, diameter of laser crater 50 μm, and irradiance 1 × 109 W cm− 2). The laser ablation system was coupled to a double-focusing sector field. The possibility was evaluated of using carbon (via measurement of 13C+) as an internal standard element for imaging element distribution as part of this method. The LA-ICP-MS images obtained for P, S, Fe Cu and Zn were quantified using synthetically prepared matrix-matched laboratory standards. Depending on the sample analyzed, concentrations of Cu and Zn in the control tissue were found to be in the range of 8–10 μg g− 1 and 10–12 μg g− 1, while in the tumor tissue these concentrations were in the range of 12–15 μg g− 1 and 15–17 μg g− 1, respectively. The measurements of P, S and Fe distribution revealed the depletion of these elements in tumor tissue. In all the samples, the shape of the tumor could be clearly distinguished from the surrounding healthy tissue by the depletion in carbon. Additional experiments were performed in order to study the influence of the water content of the analyzed tissue on the intensity signal of the analyte. The results of these measurements show the linear correlation (R2 = 0.9604) between the intensity of analyte and amount of water in the sample. The growth of a brain tumor was thus studied for the first time by imaging mass spectrometry.  相似文献   

5.
A simple and rapid method for the direct determination of Cd, Cr, Cu, Pb and Zn in soil was developed. The method was developed using three certified reference materials of soil: Eutric Cambisol, Orthic Luvisols and Rendzina, which differed in their matrix composition. Chemical modifiers were essential to achieve reproducible and interference-free signals for the analytes studied. The best results were obtained with a Pd/Mg(NO3)2 admixture for the determination of Cd, Pb and Zn and NH4F for Cu. The combination of W (as a permanent modifier) and Mg(NO3)2 provided well-defined signal profiles for Cr. The following spectral lines were used: Cd 228.8 nm, Cr 520.6 nm, Cu 218.2 nm, Pb 205.3 nm and Zn 307.6 nm. The limit of detection was 4.2 ng g− 1 for Cd, 1.1 μg g− 1 for Cr, 0.5 μg g− 1 for Cu, 1.3 μg g− 1 for Pb and 8.6 μg g− 1 for Zn for the maximum sample mass used. Under optimized conditions, the analyte and matrix were separated effectively in situ, and aqueous standards could be used for calibration.  相似文献   

6.
The present work describes the development of a sensitive analytical method based on pressurized liquid extraction (PLE) and pre-concentration by solid-phase extraction (SPE), followed by liquid chromatography–electrospray tandem mass spectrometry (LC–ESI-MS/MS) for the determination of seventeen pharmaceuticals in soils and sediments. The method is based on sample homogenisation using Na2–EDTA washed sand and extraction with water at 90 °C. Special emphasis was placed on the optimization of the extraction procedure to develop a green method that reduces, at a maximum, the use of organic solvents in order to eliminate matrix components during the clean-up. The proposed method was linear in a concentration range from 0.3 to 333 ng g−1, with correlation coefficients higher than 0.993. Method detection (MDLs) and quantification (MQLs) limits ranged from 0.1 to 6.8 ng g−1 and from 0.25 to 23 ng g−1, respectively. Absolute recoveries were analyte dependent, varying between 50% and 105% at the MQL level, except for fenofibrate (40%) and diclofenac (34%). The intra-day and inter-day precision was given by RSD values from 0.7% to 7.9% and from 1.6% to 14.5%, respectively. Acetaminophen, carbamazepine, ciprofloxacin, clofibric acid, codeine, diazepam, fenofibrate, metropolol, ofloxacin and propanolol were detected at concentrations from MDL to 35.62 ng g−1 in soils and sediments from marsh areas. Due to the low recoveries, results for fenofibrate and diclofenac can only be considered as semi-quantitative. The method was fully suitable for the other 15 pharmaceuticals.  相似文献   

7.
Two methods, based on hollow fiber liquid–liquid–liquid (three phase) microextraction (HF-LLLME) and hollow fiber liquid phase (two phase) microextraction (HF-LPME), have been developed and critically compared for the determination of methylmercury content in human hair and sludge by graphite furnace atomic absorption spectrometry (GFAAS). In HF-LPME, methylmercury was extracted into the organic phase (toluene) prior to its determination by GFAAS, while inorganic mercury remained as a free species in the sample solution. In HF-LLLME, methylmercury was first extracted into the organic phase (toluene) and then into the acceptor phase (4% thiourea in 1 mol L 1 HCl) prior to its determination by GFAAS, while inorganic mercury remained in the sample solution. The total mercury was determined by inductively coupled plasma-mass spectrometry (ICP-MS), and the levels of inorganic mercury in both HF-LLLME and HF-LPME were obtained by subtracting methylmercury from total mercury. The factors affecting the microextraction of methylmercury, including organic solvent, extraction time, stirring rate and ionic strength, were investigated and the optimal extraction conditions were established for both HF-LLLPME and HF-LPME. With a consumption of 3.0 mL of the sample solution, the enrichment factors were 204 and 55 for HF-LLLPME and HF-LPME, respectively. The limits of detection (LODs) for methylmercury were 0.1 μg L 1 and 0.4 μg L 1 (as Hg) with precisions (RSDs (%), c = 5 μg L− 1 (as Hg), n = 5) of 13% and 11% for HF-LLLPME–GFAAS and HF-LPME–GFAAS, respectively. For ICP-MS determination of total mercury, a limit of detection of 39 ng L 1 was obtained. Finally, HF-LLLME–GFAAS was applied to the determination of methylmercury content in human hair and sludge, and the recoveries for the spiked samples were in the range of 99–113%. In order to validate the method, HF-LLLME–GFAAS was also applied to the analysis of a certified reference material of NRCC DORM-2 dogfish muscle, and the determined values were in good agreement with the certified values.  相似文献   

8.
This work presents alternative procedures for the electrothermal atomic absorption spectrometric determination of boron in milk, infant formulas, and honey samples. Honey samples (10% m/v) were diluted in a medium containing 1% v/v HNO3 and 50% v/v H2O2 and introduced in the atomizer. A mixture of 20 µg Pd and 0.5 µg Mg was used for chemical modification. Calibration was carried out using aqueous solutions prepared in the same medium, in the presence of 10% m/v sucrose. The detection limit was 2 µg g− 1, equivalent to three times the standard error of the estimate (sy/x) of the regression line. For both infant formulas and milk samples, due to their very low boron content, we used a procedure based on preconcentration by solid phase extraction (Amberlite IRA 743), followed by elution with 2 mol L− 1 hydrochloric acid. Detection limits were 0.03 µg g− 1 for 4% m/v honey, 0.04 µg g− 1 for 5% m/v infant formula and 0.08 µg mL− 1 for 15% v/v cow milk. We confirmed the accuracy of the procedure by comparing the obtained results with those found via a comparable independent procedure, as well by the analysis of four certified reference materials.  相似文献   

9.
Fungicides and insecticides are commonly used preservatives to protect wood products against microbiological degradations. Currently, there is a lack of analytical methods addressing the quantitative determination of a wide range of wood preserving species in wood matrices. In this study, a reliable method was developed for the determination of a mixture of wood preserving agents with differing chemical structures (i.e., properties), including tebuconazole (TAZ), propiconazole (PAZ), 3-iodo-2-propynyl butylcarbamate (IPBC), and permethrin (PER), in pine wood. The analyte recoveries obtained by Soxhlet and multiple-stage sonication extractions were compared. While both extraction methods yielded similar results (80–100%), Soxhlet extraction was found to be less labor-intensive and thus preferred providing also lower RSDs of 1–6%. In comparison to methanol, commonly used as an extraction solvent for triazoles, acetone yielded similar extraction efficiencies for all analytes while reducing the time of sample concentration. The solid phase extraction method for triazoles was adapted to allow for a separation of IPBC and PER from the wood matrix. As opposed to previous studies, three recovery standards were employed, which enabled the correction of individual analyte losses during the sample preparation. The matrix-affected limits of detection (LODs) using gas chromatography with mass spectrometric detection were nearly the same for triazoles 0.07 and 0.21 ng g−1 for PAZ and TAZ in sapwood and 0.18 and 0.21 ng g−1 in heartwood, respectively. Higher LODs were observed for IPBC and PER: 3.9 and 1.7 ng g−1 in sapwood, and 2.0 and 6.0 ng g−1 in heartwood, respectively. The recoveries in the wood submitted to commercial sample treatment showed gradient distribution of analytes depending on the penetration of the treatment.  相似文献   

10.
The determination of bismuth requires sufficiently sensitive procedures for detection at the μg L−1 level or lower. W-coil was used for on-line trapping of volatile bismuth species using HGAAS (hydride generation atomic absorption spectrometry); atom trapping using a W-coil consists of three steps. Initially BiH3 gas is formed by hydride generation procedure. The analyte species in vapor form are transported through the W-coil trap held at 289 °C where trapping takes place. Following the preconcentration step, the W-coil is heated to 1348 °C; analyte species are released and transported to flame-heated quartz atom cell where the atomic signal is formed. In our study, interferences have been investigated in detail during Bi determination by hydride generation, both with and without trap in the same HGAAS system. Interferent/analyte (mass/mass) ratio was kept at 1, 10 and 100. Experiments were designed for carrier solutions having 1.0 M HNO3. Interferents such as Fe, Mn, Zn, Ni, Cu, As, Se, Cd, Pb, Au, Na, Mg, Ca, chloride, sulfate and phosphate were examined. The calibration plot for an 8.0 mL sampling volume was linear between 0.10 μg L−1 and 10.0 μg L−1 of Bi. The detection limit (3 s/m) was 25 ng L−1. The enhancement factor for the characteristic concentration (Co) was found to be 21 when compared with the regular system without trap, by using peak height values. The validation of the procedure was performed by the analysis of the certified water reference material and the result was found to be in good agreement with the certified values at the 95% confidence level.  相似文献   

11.
Polychlorinated biphenyls (PCBs) and polybrominated diphenyl ethers (PBDEs) are hazardous food contaminants, their maximum legally allowable levels in food and environment are in the low pg g−1 range. Therefore some highly selective and sensitive analytical methods must be used to determine them. The 96/23/EC Directive implemented by EC Decision of 12 August 2002 requires recovery rate of an analyte at a concentration below 1 ng g−1 within the 50–120% range at relative standard deviation (RSD) as low as possible.  相似文献   

12.
A multi-element graphite furnace atomic absorption spectrometry (GFAAS) method was elaborated and applied for the simultaneous determination of As, Cd, Cr, Cu, and Pb in various kinds of honey samples (acacia, floral, linden, rape, and milkweed) using the transversally heated graphite atomiser (THGA) with end-capped tubes and integrated graphite platforms (IGPs). For comparative GFAAS analysis, direct (without digestion) and indirect (with digestion in a microwave oven) sample preparation procedures were tested. The effects of several chemical modifiers, such as NH4H2PO4, NH4H2PO4-Mg(NO3)2, and Pd(NO3)2-Mg(NO3)2, were studied to obtain optimal pyrolysis and atomization conditions for the set of analytes studied. The most efficient modifier was proved to be the mixture of 5 μg Pd (applied as nitrate) plus 3 μg Mg(NO3)2, allowing the optimal 600 °C pyrolysis and 2300 °C atomization temperatures. To prevent the sputtering and foaming of the matrix during the drying and pyrolysis steps of the furnace heating program, the sample and modifier solutions (20 + 5 μl, respectively) were dispensed together onto the IGP of the THGA pre-heated at 80 °C.The effect of increasing concentration of honey matrix was studied on the integrated absorbance (Aint) signals of analytes. The Aint signals of Cr and Pb were not altered up to 10% (m/v) matrix content in the sample solutions. The matrix effect was slightly suppressive on the Aint signals of As, Cd, and Cu above 2% (m/v) honey concentration. The recovery was found to be ranged between 85 and 115% for Cd, Cr, Cu, and Pb, whereas it was a lower, compromise value of 70-99% for As. The limit of detection (LOD) data were 1, 0.04, 0.09, 0.3, and 0.6 μg l−1 for As, Cd, Cr, Cu, and Pb, respectively, which values correspond to 20, 0.8, 1.8, 5.3, and 12 ng g−1, respectively, in the solid samples. The characteristic masses were found to be 21 pg As, 1.3 pg Cd, 4 pg Cr, 12 pg Cu, and 33 pg Pb. The As, Cd, Cr, Cu, and Pb contents of the studied 42 honey samples varied significantly, i.e. from below the LOD up to 13, 3.3, 109, 445, and 163 ng g−1, respectively.  相似文献   

13.
The trace impurities Cr, Cu, Fe, K, Mn, Sb and Zn were determined in powdered aluminum nitride by direct solid sampling graphite furnace atomic absorption spectrometry using a ZEEnit 60 atomic absorption spectrometer. This spectrometer features inverse Zeeman-effect background correction and a variable magnetic field enabling measurements in two sensitivity modes over a concentration range of three orders of magnitude. The measurement sensitivity can be adjusted to the analyte concentration in the sample. The use of chemical modifiers was not necessary. Calibration was carried out by means of calibration curves obtained with aqueous standard solutions. Accuracy was checked mainly by comparison of the results with those obtained by instrumental and radiochemical neutron activation analysis whereby, excluding the results for potassium, no significant differences were found by carrying out the t-test at the significance level 0.05. The limits of detection were between 0.05 ng g−1 (Zn) and 80 ng g−1 (Fe) and the relative standard deviations below 11 %. With the proposed method, up to ten measurement cycles can be carried out in one hour.  相似文献   

14.
In this work, the potential of graphite furnace atomic absorption spectrometry for the direct determination of B in plant tissues has been investigated. Three certified reference materials (NIST SRM 1570a spinach leaves, NIST SRM 1573a tomato leaves and BCR CRM 679 white cabbage) were selected for this study, the goal always being to develop a fast procedure that could be robust enough to provide a satisfactory performance for all of them, without any modifications in the conditions applied.The use of a suitable chemical modifier was found to be essential for obtaining a reproducible and sufficiently sensitive signal for boron solutions. In this regard, the performance of the combination of citric acid plus W (added as a permanent modifier) was noteworthy, resulting in well-defined signal profiles, a remarkable analyte stabilization during the pyrolysis step (up to 2100 °C) and minimal memory effects. This mixture of modifiers provided a good performance for the direct analysis of solid samples as well, but only if a suitable temperature program, favoring the interaction between the analyte and the modifiers, was used. Thus, such a temperature program, with two pyrolysis steps and the addition of NH4NO3 in order to carry out the in situ sample microdigestion, was optimized. Under these conditions, the peak areas obtained for both solid samples and aqueous standards were comparable.Finally, the analysis of the samples was carried out. In all cases, a good agreement with the certified values was obtained, while R.S.D. values ranged between 6 and 10%. It can be concluded that the method proposed shows significant advantages for the determination of this complicated element in solid samples such as the use of aqueous standards for calibration, a high sample throughput (20 min per sample), a suitable limit of detection (0.3 μg g−1) and reduced risk of analyte losses and contamination.  相似文献   

15.
Twelve commercially available edible marine algae from France, Japan and Spain and the certified reference material (CRM) NIES No. 9 Sargassum fulvellum were analyzed for total arsenic and arsenic species. Total arsenic concentrations were determined by inductively coupled plasma atomic emission spectrometry (ICP-AES) after microwave digestion and ranged from 23 to 126 μg g−1. Arsenic species in alga samples were extracted with deionized water by microwave-assisted extraction and showed extraction efficiencies from 49 to 98%, in terms of total arsenic. The presence of eleven arsenic species was studied by high performance liquid chromatography–ultraviolet photo-oxidation–hydride generation atomic–fluorescence spectrometry (HPLC–(UV)–HG–AFS) developed methods, using both anion and cation exchange chromatography. Glycerol and phosphate sugars were found in all alga samples analyzed, at concentrations between 0.11 and 22 μg g−1, whereas sulfonate and sulfate sugars were only detected in three of them (0.6-7.2 μg g−1). Regarding arsenic toxic species, low concentration levels of dimethylarsinic acid (DMA) (<0.9 μg g−1) and generally high arsenate (As(V)) concentrations (up to 77 μg g−1) were found in most of the algae studied. The results obtained are of interest to highlight the need to perform speciation analysis and to introduce appropriate legislation to limit toxic arsenic species content in these food products.  相似文献   

16.
Closed-vessel microwave digestion of nine standard reference plant materials (NIST, BCR, IAEA) and a laboratory standard of plant material with different Si contents assisted by HNO3 + H2O2 (procedure A), HNO3 + H2O2 + HF + H3BO3 (procedure B) and HNO3 + H2O2 + HBF4 (procedure C) were used to determine the recovery of 36 elements by ICP-MS: Ag, Al, As, Ba, Be, Bi, Cd, Ce, Co, Cr, Cs, Cu, Fe, Ga, Ge, In, La, Li, Mn, Mo, Nd, Ni, Pb, Pr, Rb, Sb, Se, Sn, Sr, Th, Tl, U, V, W, Y, Zn. Additions of HF + H3BO3 and HBF4 in procedures B and C exceeded by 10% (B1, C1) and 100% (B2, C2) the equivalent concentrations of Si in the samples determined by ICP-OES. Most recoveries of certified elements (e.g., Al*, Cu, Mo*, Rb*, Sb*, Th) decreased significantly (*p ≤ 0.05) with increasing Si content in plant reference materials digested by procedure A, while the recoveries from procedures B and C decreased insignificantly only for Mo and Sb. Digestions B and C gave significantly higher recoveries of Al, Sb, W and REEs, which were tighter to the reference values of these elements. A similar effect was found for Cu, Fe, Li, Ni, Sn, Th, Tl, V, Zn, Ba, Rb and Sr recoveries in samples with Si contents exceeding 2000 μg g−1. If the Si content in plant samples is less than 10 mg g−1, digestion of 0.5 g of plant samples through 0.05 mL of HF and 0.5 mL of 4% H3BO3 or 0.1 mL of HBF4 is recommended to get satisfactory results for most of the elements. For materials with Si content exceeding 10 mg g−1 the weight of the sample for digestion should be reduced to 0.25 g. However, the operation of potential interferences should be taken into account and eliminated through correction equations and adequate dilution of the samples.  相似文献   

17.
Bismuth was evaluated as internal standard for Pb determination by line source flame atomic absorption spectrometry (LS FAAS), high-resolution continuum source flame atomic absorption spectrometry (HR-CS FAAS) and line source graphite furnace atomic absorption spectrometry (LS GFAAS). Analysis of samples containing different matrices indicated close relationship between Pb and Bi absorbances. Correlation coefficients of calibration curves built up by plotting APb/ABiversus Pb concentration were higher than 0.9953 (FAAS) and higher than 0.9993 (GFAAS). Recoveries of Pb improved from 52–118% (without IS) to 97–109% (IS, LS FAAS); 74–231% (without IS) to 96–109% (IS, HR-CS FAAS); and 36–125% (without IS) to 96–110% (IS, LS GFAAS). The relative standard deviations (n = 12) were reduced from 0.6–9.2% (without IS) to 0.3–4.3% (IS, LS FAAS); 0.7–7.7% (without IS) to 0.1–4.0% (IS, HR-CS FAAS); and 2.1–13% (without IS) to 0.4–5.9% (IS, LS GFAAS).  相似文献   

18.
A novel solid phase extraction technique for the speciation of trace dissolved Fe(II) and Fe(III) in environmental water samples was developed by coupling micro-column packed with N-benzoyl-N-phenylhydroxylamine (BPHA) loaded on microcrystalline naphthalene to electrothermal vaporization inductively coupled plasma-optical emission spectrometry (ETV-ICP-OES). Various influencing factors on the separation and preconcentration of Fe(II) and Fe(III), such as the acidity of the aqueous solution, sample flow rate and volume, have been investigated systematically, and the optimized operation conditions were established. At pH 3.0 Fe(III) could be selectively retained by micro-column (20 mm × 1.4 mm, i.d.) packed with BPHA immobilized on microcrystalline naphthalene, and Fe(II) passed through the micro-column. Both Fe(II) and Fe(III) could be adsorbed by the micro-column at pH 6.5. Thus, the total Fe could be determined without the need for preoxidation of Fe(II) to Fe(III). The retained Fe(III) or the Fe(II) and Fe(III) was subsequently eluted by 0.1 ml of 1 mol l−1 HCl. The adsorption capacity of the solid phase adsorption material was found to be 45.0 mg g−1 for Fe(III) at pH 3.0 and 65.3 mg g−1 for Fe(II) at pH 6.5, respectively. The detection limit (3σ) of 0.053 μg l−1 was obtained with a practical enrichment factor of 156 at a sample volume of 17 ml. The relative standard deviations of 4.2% and 4.6% (CFe(III) = CFe(II) = 10 μg l−1, n = 7) for Fe(III) and total iron were found, respectively. The method was successfully applied to the determination of trace Fe(II) and Fe(III) in environmental water samples (East Lake water, local tap water and mineral water). In order to validate the method, the developed method was applied to the determination of total iron in certified materials of NIES NO.10-b rice flour and GBW07605 tea leaves, and the results obtained were in good agreement with the certified values.  相似文献   

19.
A true direct solid sampling electrothermal atomic absorption spectrometry method with Zeeman-effect background correction (Analytik Jena ZEEnit 60 AAS) was developed for the determination of As, Cd, Hg, Pb, Sb and Zn in powdered titanium dioxide of pharmaceutical, food and cosmetics grade. The interaction of the titanium matrix and graphite surface of the sample carrier boat in a transversely heated graphite tube atomizer was investigated. Conversion of titanium dioxide to interfering TiO2–TiC-liquid phase, running out the sampling boat, was observed at temperatures above 2000 °C. The temperature program was optimized accordingly for these volatile analytes in atomization and cleaning steps in order to prevent this interference and to prolong significantly the analytical lifetime of the boat to more than one thousand runs. For all elements, calibration by aqueous standard addition method, by wet-chemically analyzed samples with different content of analytes and/or by dosing one sample in different amounts, were proved as adequate quantification procedures. Linear dynamic calibration working ranges can be considerably expanded up to two orders of magnitude within one measurement run by applying three-field dynamic mode of the Zeeman background correction system. The results obtained by true direct solid sampling technique are compared with those of other independent, mostly wet-chemical methods. Very low limits of detection (3σ criterion) of true solid sampling technique of 21, 0.27, 24, 3.9, 6.3 and 0.9 ng g− 1 were achieved for As, Cd, Hg, Pb, Sb and Zn, respectively.  相似文献   

20.
A new and simple method was developed for preconcentration trace amount of gold in aqueous and mineral samples. The method was based on the sorption of gold on granular activated carbon (AC) in acidic medium (hydrochloric acid) and subsequently direct determination by graphite furnace atomic absorption spectrometry (GFAAS). A small particle of adsorbent was delivered to small volume of sample. After extraction, AC removed and analyzed directly by GFAAS. Several factors influencing the extraction efficiency, such as the hydrochloric acid concentration, sample volume and extraction time were studied as well as effect of potential interfering ions. The preconcentration factor 50 was obtained. The limit of detection (LOD) of gold in water and soil samples was 0.007 μg L− 1 and 0.9 ng g− 1, respectively. The proposed method was applied successfully to the determination of trace amount of gold in environmental and geological samples. In order to validate the developed method, two certified reference materials: Platinum Ore (SARM-7B) and Copper Ore Mill Heads (No. 330) were analyzed and the determined values obtained were in good agreement with the certified values and recovery was obtained in the range of 80-118%. The relative standard deviations (RSD) for the spiking levels of 0.5 μg L− 1 in the real samples was 4%, (n = 15).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号