1.
Particle separation is a fundamental operation in the areas of biology and physical chemistry. A variety of force fields have been used to separate particles in microfluidic devices, among which electric field may be the most popular one due to its general applicability and adaptability. So far, however, electrophoresis‐based separations have been limited primarily to batchwise processes. Dielectrophoresis (DEP)‐based separations require in‐channel micro‐electrodes or micro‐insulators to produce electric field gradients. This article introduces a novel particle separation technique in DC electrokinetic flow through a planar double‐spiral microchannel. The continuous separation arises from the cross‐stream dielectrophoretic motion of particles induced by the non‐uniform electric field inherent to curved channels. Specifically, particles are focused by DEP to one sidewall of the first spiral, and then dielectrophoretically deflected toward the other sidewall of the second spiral at a particle‐dependent rate, leading to focused particle streams along different flow paths. This DEP‐based particle separation technique is demonstrated in an asymmetric double‐spiral microchannel by continuously separating a mixture of 5/10 μm particles and 3/5 μm particles.  相似文献   

2.
The laterally asymmetric diffusion array, a biomolecule sorting device, was used to continuously separate a mixture of T2 and T7 coliphage DNA molecules into its constituents. A two-dimensional array of obstacles (in the presence of an average flow v) can be used to rectify the Brownian motion of particles (in this case DNA molecules) so that they diffuse preferentially in one direction, and perpendicular to the direction of the applied field (in this case an electric field). This type of device had not yet been used for actual fractionation of biomolecules, due to difficulties in injection of the sample. Here we show that with a new injection strategy a well-defined, narrow and continuous stream of molecules can be injected into the separation channel, thus enabling this separation technique to be used in a working device. We expect this type of device could now be employed for separation of a variety of different biomolecules, ranging from long dsDNA to small proteins.  相似文献   

3.
A microchannel device is presented which separates and focuses charged proteins based on electric field gradient focusing. Separation is achieved by setting a constant electroosmotic flow velocity against step changes in electrophoretic velocity. Where these two velocities are balanced for a given analyte, the analyte focuses at that point because it is driven to it from all points within the channel. We demonstrate the separation and focusing of a binary mixture of bovine serum albumin and phycoerythrin. The device is constructed of intersecting microchannels in poly(dimethylsiloxane)(PDMS) inlaid with hollow dialysis fibers. The device uses no exotic chemicals such as antibodies or synthetic ampholytes, but operates instead by purely physical means involving the independent manipulation of electrophoretic and electroosmotic velocities. One important difference between this apparatus and most other devices designed for field-gradient focusing is the injection of current at discrete intersections in the channel rather than continuously along the length of a membrane-bound separation channel.  相似文献   

4.
Church C  Zhu J  Xuan X 《Electrophoresis》2011,32(5):527-531
Dielectrophoresis has been widely used to focus, trap, concentrate, and sort particles in microfluidic devices. This work demonstrates a continuous separation of particles by size in a serpentine microchannel using negative dielectrophoresis. Depending on the magnitude of the turn-induced dielectrophoretic force, particles travelling electrokinetically through a serpentine channel either migrate toward the centerline or bounce between the two sidewalls. These distinctive focusing and bouncing phenomena are utilized to implement a dielectrophoretic separation of 1 and 3 μm polystyrene particles under a DC-biased AC electric field of 880 V/cm on average. The particle separation process in the entire microchannel is simulated by a numerical model.  相似文献   

5.
We report a contraction-expansion array (CEA) microchannel that allows inertial size separation by a force balance between inertial lift and Dean drag forces in fluid regimes in which inertial fluid effects become significant. An abrupt change of the cross-sectional area of the channel curves fluid streams and produces a similar effect compared to Dean flows in a curved microchannel of constant cross-section, thereby inducing Dean drag forces acting on particles. In addition, the particles are influenced by inertial lift forces throughout the contraction regions. These two forces act in opposite directions each other throughout the CEA microchannel, and their force balancing determines whether the particles cross the channel, following Dean flows. Here we describe the physics and design of the CEA microfluidic device, and demonstrate complete separation of microparticles (polystyrene beads of 4 and 10 μm in diameter) and efficient exchange of the carrier medium while retaining 10 μm beads.  相似文献   

6.
A new method for continuous size separation and collection of particles in microfabricated devices, asymmetric pinched flow fractionation (AsPFF), has been proposed and demonstrated. This method improves the separation scheme of pinched flow fractionation (PFF), which utilizes a laminar flow profile inside a microchannel. In this study, multiple branch channels with different channel dimensions were arranged at the end of the pinched segment, so that the flow rate distributions to each branch channel were varied, and a large part of the liquid was forced to go through one branch channel (drain channel). In the proposed channel system, the flow profile inside the microchannel was asymmetrically amplified, enabling the separation of one-order smaller particles compared with PFF. After introducing the method, we examined the effect of the asymmetric amplification by controlling the outlet of the drain channel. Also, a mixture of 1.0 approximately 5.0 microm particles was separated, and erythrocytes were successfully separated from blood. The results indicate that the AsPFF method could be applied to the separation of much smaller-size particles, since more precise separation can be achieved simply by changing the geometries of branch channels.  相似文献   

7.
Yalcin SE  Sharma A  Qian S  Joo SW  Baysal O 《Electrophoresis》2010,31(22):3711-3718
Various particle manipulations including enrichment, movement, trapping, separation, and focusing by floating electrodes attached to the bottom wall of a straight microchannel under an imposed DC electric field have been experimentally demonstrated. In contrast to a dielectric microchannel possessing a nearly uniform surface charge (or ζ potential), the metal strip (floating electrode) is polarized under the imposed electric field, resulting in a nonuniform distribution of the induced surface charge with a zero net surface charge along the floating electrode's surface, and accordingly induced-charge electroosmotic flow near the metal strip. The induced induced-charge electroosmotic flow can be regulated by controlling the strength of the imposed electric field and affects both the hydrodynamic field and the particle's motion. By using a single floating electrode, charged particles could be locally concentrated in a section of the channel or in an end-reservoir and move toward either the anode or the cathode by controlling the strength of the imposed electric field. By using double floating electrodes, negatively charged particles could be concentrated between the floating electrodes, subsequently squeezed to a stream flowing in the center region of the microchannel toward the cathodic reservoir, which can be used to focus particles.  相似文献   

8.
Microparticle separation and concentration based on size has become indispensable in many biomedical and environmental applications. In this paper we describe a passive microfluidic device with spiral microchannel geometry for complete separation of particles. The design takes advantage of the inertial lift and viscous drag forces acting on particles of various sizes to achieve differential migration, and hence separation, of microparticles. The dominant inertial forces and the Dean rotation force due to the spiral microchannel geometry cause the larger particles to occupy a single equilibrium position near the inner microchannel wall. The smaller particles migrate to the outer half of the channel under the influence of Dean forces resulting in the formation of two distinct particle streams which are collected in two separate outputs. This is the first demonstration that takes advantage of the dual role of Dean forces for focusing larger particles in a single equilibrium position and transposing the smaller particles from the inner half to the outer half of the microchannel cross-section. The 5-loop spiral microchannel 100 microm wide and 50 microm high was used to successfully demonstrate a complete separation of 7.32 microm and 1.9 microm particles at Dean number De = 0.47. Analytical analysis supporting the experiments and models is also presented. The simple planar structure of the separator offers simple fabrication and makes it ideal for integration with on-chip microfluidic systems, such as micro total analysis systems (muTAS) or lab-on-a-chip (LOC) for continuous filtration and separation applications.  相似文献   

9.
Separation of microparticle in viscoelastic fluid is highly required in the field of biology and clinical medicine. For instance, the separation of the target cell from blood is an important prerequisite step for the drug screening and design. The microfluidic device is an efficient way to achieve the separation of the microparticle in the viscoelastic fluid. However, the existing microfluidic methods often have some limitations, including the requirement of the long channel length, the labeling process, and the low throughput. In this work, based on the elastic-inertial effect in the viscoelastic fluid, a new separation method is proposed where a gradually contracted microchannel is designed to efficiently adjust the forces exerted on the particle, eventually achieving the high-efficiency separation of different sized particles in a short channel length and at a high throughput. In addition, the separation of WBCs and RBCs is also validated in the present device. The effect of the flow rate, the fluid property, and the channel geometry on the particle separation is systematically investigated by the experiment. With the advantage of small footprint, simple structure, high throughput, and high efficiency, the present microfluidic device could be utilized in the biological and clinical fields, such as the cell analysis and disease diagnosis.  相似文献   

10.
On‐chip generation of pressure gradients via electrokinetic means can offer several advantages to microfluidic assay design and operation in a variety of applications. In this article, we describe a simple approach to realizing this capability by employing a polyacrylamide‐based gel structure fabricated within a fluid reservoir located at the terminating end of a microchannel. Application of an electric field across this membrane has been shown to block a majority of the electroosmotic flow generated within the open duct yielding a high pressure at the channel–membrane junction. Experiments show the realization of higher pressure‐driven velocities in an electric field‐free separation channel integrated to the micropump with this design compared to other similar micropumps described in the literature. In addition, the noted velocity was found to be less sensitive to the extent of Debye layer overlap in the channel network, and therefore more impressive when working with background electrolytes having higher ionic strengths. With the current system, pressure‐driven velocities up to 3.6 mm/s were realized in a 300‐nm‐deep separation channel applying a maximum voltage of 3 kV at a channel terminal. To demonstrate the separative performance of our device, a nanofluidic pressure‐driven ion‐chromatographic analysis was subsequently implemented that relied on the slower migration of cationic analytes relative to the neutral and anionic ones in the separation channel likely due to their strong electrostatic interaction with the channel surface charges. A mixture of amino acids was thus separated with resolutions greater than those reported by our group for a similar analysis previously.  相似文献   

11.
A microfluidic traveling-wave electrophoresis (TWE) system is reported that uses a locally defined traveling electric field wave within a microfluidic channel to achieve band transport and separation. Low voltages, over a range of -0.5 to +0.5 V, are used to avoid electrolysis and other detrimental redox reactions while the short distance between electrodes, ~25 μm, provides high electric fields of ~200 V cm(-1). It is expected that the low voltage requirements will simplify the future development of smaller portable devices. The TWE device uses four interdigitated electrode arrays: one interdigitated electrode array pair is on the top of the microchannel and the other interdigitated electrode array pair is on the microchannel bottom. The top and bottom substrates are joined by a PDMS spacer that has a nominal height of 15 μm. A pinched injection scheme is used to define a narrow sample band within an injection cross either electrokinetically or hydrodynamically. Separation of two dyes, fluorescein and FLCA, with baseline resolution is achieved in less than 3 min and separation of two proteins, insulin and casein is demonstrated. Investigation of band broadening with fluorescein reveals that sample band widths equivalent to the diffusion limit can be achieved within the microfluidic channel, yielding highly efficient separations. This low level of band broadening can be achieved with capillary electrophoresis, but is not routinely observed in microchannel electrophoresis. Sample enrichment can be achieved very easily with TWE using a device with converging electric field waves controlled by two sets of independently controlled interdigitated electrodes arrays positioned serially along the microchannel. Sample enrichment of 40-fold is achieved without heterogeneous buffer/solvent systems, sorptive, or permselective materials. While there is much room for improvement in device fabrication, and many capabilities are yet to be demonstrated, it is anticipated that the capabilities and performance demonstrated herein will enable new lab-on-a-chip processes and systems.  相似文献   

12.
Using the concept of insulator-based "electrodeless" dielectrophoresis, we present a novel geometry for shaping electric fields to achieve lateral deviation of particles in liquid flows. The field is generated by lateral planar metal electrodes and is guided along access channels to the active area in the main channel. The equipotential surfaces at the apertures of the access channels behave as vertical "liquid" electrodes injecting the current into the main channel. The field between a pair of adjacent liquid electrodes generates the lateral dielectrophoretic force necessary for particle manipulation. We use this force for high-speed deviation of particles. By adding a second pair of liquid electrodes, we focus a particle stream. The position of the focused stream can be swept across the channel by adjusting the ratio of the voltages applied to the two pairs. Based on conformal mapping, we provide an analytical model for estimating the potential at the liquid electrodes and the field distribution in the main channel. We show that the simulated particle trajectories agree with observations. Finally, we show that the model can be used to optimize the device geometry in different applications.  相似文献   

13.
This work reports on protein transport phenomena discovered in partitioning experiments with a novel setup for continuous-flow two-phase electrophoresis consisting of a microchannel in which a phase boundary is formed in flow direction. Proteins can be partitioned exploiting their affinity to different aqueous phases in two-phase systems. This separation process may be enhanced or extended by applying an electric field perpendicular to the phase boundary. In this context, microsystems offer new possibilities, as interfacial forces usually dominate over volume forces, thus allowing a superior control of the formation and arrangement of liquid/liquid phase boundaries. The two immiscible phases which are injected separately into the microchannel are taken from a polyethylene glycol (PEG)-dextran system. The side walls of the channel are partially made of gel material which serves as an ion conductor and decouples the channel from the electrodes, thus preventing bubble generation inside the separation channel. The experiments show that the electrophoretic transport of proteins between the laminated liquid phases is characterized by a strong asymmetry. When bovine serum albumin (BSA) is introduced into the PEG-rich phase, it can easily be transferred into the dextran-rich phase via an applied electric field of low strength or just by diffusion. In the reverse case, up to a certain field strength the transfer to the opposing phase is strongly inhibited. Only if the field strength is further increased will the BSA molecules leave the dextran-rich phase almost completely.  相似文献   

14.
This paper reports a microfluidic method of continuous separation of marine algae and particles by DC dielectrophoresis. The locally non-uniform electric field is generated by an insulating PDMS triangle hurdle fabricated within a PDMS microchannel. Both the particles and algae are subject to negative DEP forces at the hurdle where the gradient of local electric-field strength is the strongest. The DEP force acting on the particle or the algae depends on particles’ or algae’s volume, shape and dielectric properties. Thus the moving particles and algae will be repelled to different streamlines when passing the hurdle. In this way, combined with the electroosmotic flow, continuous separation of algae of two different sizes, and continuous separation of polystyrene particles and algae with similar volume but different shape were achieved. This first demonstration of DC DEP separation of polystyrene particles and algae with similar sizes illustrates the great influence of dielectric properties on particle separation and potentials for sample pretreatment.  相似文献   

15.
Analysis of geometry effects on band spreading of microchip electrophoresis   总被引:2,自引:0,他引:2  
Fu LM  Yang RJ  Lee GB 《Electrophoresis》2002,23(4):602-612
The geometry and the flow field conditions in the separation microchannel of an electrophoresis chip system may have important impact on the system's separation efficiency. Understanding the geometry effect on the flow field physics in the separation microchannel is beneficial to the design or operation of an electrophoresis system. The turns in a microfabricated separation microchannel generally results in degraded separation quality. To avoid this limitation, channels are constructed with different types of turns to determine the optimum design that minimizes turn-induced band broadening. We have designed and tested various geometric bend ratios to greatly reduce this so-called "racetrack" effect. The effects of the separation channel geometry, fluid velocity profile and bend ratio on the band distribution in the detection area are discussed. Results show that the folded square U-shaped channel is better for miniaturization and simplification. The band tilting was corrected and the racetrack effect reduced in the detection area when the bend ratio is 4:1. The detection time obtained from the present numerical solution matches very well with the experimental data.  相似文献   

16.
Choi S  Park JK 《Lab on a chip》2005,5(10):1161-1167
This paper presents a novel microfluidic device for dielectrophoretic separation based on a trapezoidal electrode array (TEA). In this method, particles with different dielectric properties are separated by the device composed of the TEA for the dielectrophoretic deflection of particles under negative dielectrophoresis (DEP) and poly(dimethylsiloxane)(PDMS) microfluidic channel with a sinuous and expanded region. Polystyrene microparticles are exposed to an electric field generated from the TEA in the microfluidic channel and are dielectrophoretically focused to make all of them line up to one sidewall. When these particles arrive at the region of another TEA for dielectrophoretic separation, they are separated having different positions along the perpendicular direction to the fluid flow due to their different dielectrophoretic velocities. To evaluate the separation process and performance, both the effect of the flow rate on dielectrophoretic focusing and the influence of the number of trapezoidal electrodes on dielectrophoretic separation are investigated. Now that this method utilizes the TEA as a source of negative DEP, non-specific particle adhering to the electrode surface can be prevented; conventional separation approaches depending on the positive DEP force suffer from this problem. In addition, since various particle types are continuously separated, this method can be easily applicable to the separation and analysis of various dielectric particles with high particle recovery and selectivity.  相似文献   

17.
This paper theoretically explores the application of electric field flow fractionation (EFFF) for the size-based separation of DNA strands in a microchannel. An axial electric field cannot separate DNA strands in solution because the electrical mobility of the strands is independent of the length. However, lateral electric fields coupled with an axial Poiseuille flow can separate the DNA strands of different sizes. By using regular perturbation analysis, we obtain the effective diffusivity and the mean velocity of the DNA molecules that are undergoing a pressure driven Poiseuille flow in a 2D channel in presence of a lateral electric field. The mean velocities and the dispersion coefficients are then utilized to determine the scaling for length of the channel and the time required for separation of DNA molecules in different parameter regimes. The results show that EFFF can separate DNA strands in the range of 10 kbp that differ in size by about 2.5 kbp in about half an hour in a 1 cm long channel. While DNA strands can be separated by EFFF, the performance of devices based on EFFF seems to be at best comparable to other techniques such as entropic trapping.  相似文献   

18.
In a microbiological device, cell or particle manipulation and characterization require the use of electric field on different electrodes in several configurations and shapes. To efficiently design microelectrodes within a microfluidic channel for dielectrophoresis focusing, manipulation and characterization of cells, the designer will seek the exact distribution of the electric potential, electric field and hence dielectrophoresis force exerted on the cell within the microdevice. In this paper we describe the approach attaining the analytical solution of the dielectrophoretic force expression within a microchannel with parallel facing same size electrodes present on the two faces of channel substrates, with opposite voltages on the pair electrodes. Simple Fourier series mathematical expressions are derived for electric potential, electric field and dielectric force between two distant finite‐size electrodes. Excellent agreement is found by comparing the analytical results calculated using MATLAB? with numerical ones obtained by Comsol. This analytical result can help the designer to perform simple design parametric analysis. Bio‐microdevices are also designed and fabricated to illustrate the theoretical solution results with the experimental data. Experiments with red blood cells show the dielectrophoretic force contour plots of the analytical data matched to the experimental results.  相似文献   

19.
This paper presents the development and experimental analysis of a dielectrophoresis (DEP) system, which is used for the manipulation and separation of microparticles in liquid flow. The system is composed of arrays of microelectrodes integrated to a microchannel. Novel curved microelectrodes are symmetrically placed with respect to the centre of the microchannel with a minimum gap of 40 μm. Computational fluid dynamics method is utilised to characterise the DEP field and predict the dynamics of particles. The performance of the system is assessed with microspheres of 1, 5 and 12 μm diameters. When a high‐frequency potential is applied to microelectrodes a spatially varying electric field is induced in the microchannel, which creates the DEP force. Negative‐DEP behaviour is observed with particles being repelled from the microelectrodes. The particles of different dimensions experience different DEP forces and thus settle to separate equilibrium zones across the microchannel. Experiments demonstrate the capability of the system as a field flow fraction tool for sorting microparticles according to their dimensions and dielectric properties.  相似文献   

20.
The size separation of Brownian particles with the same free mobility in an electrophoretic microchannel with alternating thick regions and narrow constrictions is studied theoretically. The electrophoretic mobility is field dependent and generally increases with field strength. In weak fields, Brownian diffusion dominates and the migration is controlled by the entrance effect. Therefore, smaller particles migrate faster than larger ones. In strong fields, however, the particle tends to follow electric field lines. Smaller particles are susceptible to Brownian motion and thus influenced by the nonuniform electric field in the well significantly. As a result, larger particles possess higher mobilities. Our simulation results agree with the experimental observations and provide guidance for efficient nanofluidic separation.  相似文献   