首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
An LC–MS/MS method was developed and validated for the simultaneous quantification of edaravone and taurine in beagle plasma. The plasma sample was deproteinized using acetonitrile containing formic acid. Chromatographic separations were achieved on an Agilent Zorbax SB‐Aq (100 × 2.1 mm, 3.5 μm) column, with a gradient of water (containing 0.03% formic acid) and methanol as the mobile phase at a flow rate of 0.3 mL/min. The analyte detection was carried out in multiple reaction monitoring mode and the optimized precursor‐to‐product transitions of m/z [M+H]+ 175.1 → 133.0 (edaravone), m/z [M+H]+ 189.1 → 147.0 (3‐methyl‐1‐p‐tolyl‐5‐pyrazolone, internal standard, IS), m/z [M–H]? 124.1→80.0 (taurine), and m/z [M–H]? 172.0 → 80.0 (sulfanilic acid, IS) were employed to quantify edaravone, taurine, and their corresponding ISs, respectively. The LOD and the lower LOQ were 0.01 and 0.05 μg/mL for edaravone and 0.66 and 2 μg/mL for taurine, respectively. The calibration curves of these two analytes demonstrated good linearity (r > 0.99). All the validation data including the specificity, precision, recovery, and stability conformed to the acceptable requirements. This validated method has successfully been applied in the pharmacokinetic study of edaravone and taurine mixture in beagle dogs.  相似文献   

2.
A simple, sensitive and selective high‐performance liquid chromatography electrospray ionization tandem mass spectrometry (LC‐MS/MS) method was developed for simultaneous determination and pharmacokinetic study of caffeic acid (CA) and its active metabolites. The separation with isocratic elution used a mobile phase composed of methanol and water (containing 0.1% formic acid) at a flow rate of 0.2 mL/min. The detection of target compounds was done in selected reaction monitoring (SRM) mode. The SRM detection was operated in the negative electrospray ionization mode using the transitions m/z 179 ([M ? H]?) → 135 for CA, m/z 193 ([M ? H]?) → 134.8 for ferulic acid and isoferulic acid and m/z 153 ([M ? H]?) → 108 for protocatechuic acid. The method was linear for all analytes over the investigated range with all correlation coefficients 0.9931. The lower limits of quantification were 5.0 ng/mL for analytes. The intra‐ and inter‐day precisions (relative standard deviation) were <5.86 and <6.52%, and accuracy (relative error) was between ?5.95 and 0.35% (n = 6). The developed method was applied to study the pharmacokinetics of CA and its major active metabolites in rat plasma after oral and intravenous administration of CA. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

3.
A simple, rapid, sensitive and selective liquid chromatography / tandem mass spectrometry method was developed and validated for the quantification of pentoxifylline, a haemorheological agent. The analyte and internal standard, tamsulosin were extracted by liquid-liquid extraction with ethyl acetate and were separated using an isocratic mobile phase on a reverse phase C18 column. The analytes were analyzed by mass spectrometry in the multiple reaction monitoring mode using the respective [M+H]+ ions, m/z 279/138 for pentoxifylline and m/z 409/228 for the IS. The assay exhibited a linear dynamic range of 2–1000 ng mL−1 for pentoxifylline in human plasma. The lower limit of quantification was 2 ng mL−1 with a relative standard deviation of less than 10%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. A run time of 1.5 min for each sample made it possible to analyze more than 400 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability or bioequivalence studies. Revised: 4 and 20 October 2005  相似文献   

4.
A simple, sensitive and specific ultra‐performance liquid chromatography–tandem mass spectrometry (UPLC‐MS/MS) method was developed and validated to determine the concentrations of 7‐hydroxymitragynine in rat plasma. Following a single‐step liquid–liquid extraction of plasma samples using chloroform, 7‐hydroxymitragynine and the internal standard (tryptoline) were separated on an Acquity UPLCTM BEH C18 (1.7 µm, 2.1 × 50 mm) column using an isocratic elution at a flow rate of 0.2 mL/min. The mobile phase consisted of 0.1% acetic acid in water and 0.1% acetic acid in acetonitrile (10:90, v/v). The run time was 2.5 min. The analysis was carried out under the multiple reaction‐monitoring mode using positive electrospray ionization. Protonated ions [M + H]+ and their respective product ions were monitored at the following transitions: 415 → 190 for 7‐hydroxymitragynine and 173 → 144 for the internal standard. The calibration curve was linear over the range of 10–4000 ng/mL (r2 = 0.999) with a lower limit of quantification of 10 ng/mL. The extraction recoveries ranged from 62.0 to 67.3% at concentrations of 20, 600 and 3200 ng/mL). Intra‐ and inter‐day assay precisions (relative standard deviation) were <15% and the accuracy was within 96.5–104.0%. This validated method was successfully applied to quantify 7‐hydroxymitragynine in rat plasma following intravenous administration. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

5.
Gambogic acid and gambogenic acid are two major bioactive components of Garcinia hanburyi, and play a pivotal role in biologic activity. In this study, a specific and sensitive liquid chromatography–tandem mass spectrometry was developed and validated for simultaneous determination of gambogic acid and gambogenic acid in rat plasma. Chromatographic separation was achieved on a C18 column using an isocratic elution with methanol–10 m m ammonium acetate buffer–acetic acid (90:10:0.1, v/v/v) as the mobile phase. The detection was performed on a triple–quadrupole tandem mass spectrometer equipped with electrospray positive ionization using multiple reaction monitoring modes. The transitions monitored were m/z 629.3 [M + H]+ → 573.2 for gambogic acid, m/z 631.2 [M + H]+ → 507.2 for gambogenic acid and m/z 444.2 [M + NH4]+ → 83.1 for IS. Linear calibration curves were obtained in the concentration range of 2.00–1000 ng/mL for gambogic acid and 0.500–250 ng/mL for gambogenic acid. The lower limits of quantification of gambogic acid and gambogenic acid in rat plasma were 2.00 and 0.500 ng/mL, respectively. The intra‐ and inter‐day precision (RSD) values were <11.7% and accuracy (RE) was ?10.6–12.4% at three QC levels for both analytes. The assay was successfully applied to evaluate pharmacokinetics behavior in rats after oral administration of Garcinia hanburyi extracts. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

6.
An LC‐MS/MS method for the determination of GDC‐0980 (apitolisib) concentrations in dog plasma has been developed and validated for the first time to support pre‐clinical drug development. Following protein precipitation with acetonitrile, the resulting samples were analyzed using reverse‐phase chromatography on a Metasil AQ column. The mass analysis was performed on a triple quadruple mass spectrometer coupled with an electrospray interface in positive ionization mode. The selected reaction monitoring transitions monitored were m/z 499.3 → 341.1 for GDC‐0980 and m/z 507.3 → 341.1 for IS. The method was validated over the calibration curve range 0.250–250 ng/mL with linear regression and 1/x2 weighting. Relative standard deviation (RSD) ranged from 0.0 to 10.9% and accuracy ranged from 93.4 to 113.6% of nominal. Stable‐labeled internal standard GDC‐0980‐d8 was used to minimize matrix effects. This assay was used for the measurement of GDC‐0980 dog plasma concentrations to determine toxicokinetic parameters after oral administration of GDC‐0980 (0.03, 0.1 and 0.3 mg/kg) to beagle dogs in a GLP toxicology study. Peak concentration ranged from 3.23 to 84.9 ng/mL. GDC‐0980 was rapidly absorbed with a mean time to peak concentration ranging from 1.3 to 2.4 h. Mean area under the concentration–time curve from 0 to 24 hours ranged from 54.4 to 542 ng h/mL. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

7.
Analyses of a series of nitroaromatic compounds using fast atom bombardment (FAB) mass spectrometry are discussed. An interesting ion-molecule reaction leading to [M + O ? H]? ions is observed in the negative ion FAB spectra. Evidence from linked-scan and collision-induced dissociation spectra proved that [M + O ? H]? ions are produced by the following reaction: M + NO2? → [M + NO2]? → [M + O ? H]?. These experiments also showed that M ions are produced in part by the exchange of an electron between M and NO2? species. All samples showed M, [M ? H]? or both ions in their negative ion FAB spectra. Not all analytes studied showed either [M + H]+ and/or M+˙ in the positive ion FAB spectra. No M+˙ ions were observed for ions having ionization energies above ~9 eV.  相似文献   

8.
Three liquid chromatography–tandem mass spectrometry (LC‐MS/MS) methods were respectively developed and validated for the simultaneous or independent determination of taurine and edaravone in rat plasma using 3‐methyl‐1‐p‐tolyl‐5‐pyrazolone and sulfanilic acid as the internal standards (IS). Chromatographic separations were achieved on an Agilent Zorbax SB‐Aq (100 × 2.1 mm, 3.5 µm) column. Gradient 0.03% formic acid–methanol, isocratic 0.1% formic acid–methanol (90:10) and 0.02% formic acid–methanol (40:60) were respectively selected as the mobile phase for the simultaneous determination of two analytes, taurine or edaravone alone. The MS acquisition was performed in multiple reaction monitoring mode with a positive and negative electrospray ionization source. The mass transitions monitored were m/z [M + H]+ 175.1 → 133.0 and [M + H]+ 189.2 → 147.0 for edaravone and its IS, m/z [M ? H]? 124.1 → 80.0 and [M ? H]? 172.0 → 80.0 for taurine and its IS, respectively. The validated methods were successfully applied to study the pharmacokinetic interaction of taurine and edaravone in rats after independent intravenous administration and co‐administration with a single dose. Our collective results showed that there were no significant alterations on the main pharmacokinetic parameters (area under concentration–time curve, mean residence time, half‐life and clearance) of taurine and edaravone, implying that the proposed combination therapy was pharmacologically feasible. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

9.
Sensitive and selective analytical procedures based on high‐performance liquid chromatography with mass spectrometric detection were developed for the determination of amoxicillin in human plasma samples. Samples were prepared by applying in‐house manufactured molecularly imprinted solid‐phase microextraction probes. The detection of target compounds was performed in multiple reaction monitoring mode. The multiple reaction monitoring detection was operated in the positive electrospray ionization mode using the transitions of m/z 366 ([M + H]+) → 349 for amoxicillin and m/z 390 ([M + H]+) → 372 for gemifloxacin. The method was validated with precision within 15% relative standard deviation and accuracy within 15% relative error. The method was successfully applied to study of the pharmacokinetics of amoxicillin in human plasma after oral administration of amoxicillin. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

10.
A rapid and sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) assay was developed and validated to quantify a novel antineoplastic agent, PM02734, in dog plasma. The method was validated to demonstrate the specificity, limit of quantification (LOQ), accuracy, and precision of measurements. The calibration range for PM02734 was established using PM02734 standards from 0.05 to 100 ng/mL in blank plasma. The dominating ions were doubly charged molecular ions [M+2H]2+ at m/z 740.0 instead of singly charged ones at m/z 1478.4. The selected reaction monitoring (SRM), based on the m/z 740.0 --> 212.2 transition, was specific for PM02734, and that based on the m/z 743.8 --> 212.2 transition was specific for deuterated PM02734 (the internal standard, IS); no endogenous materials interfered with the analysis of PM02734 and IS from blank plasma. The assay was linear over the concentration range 0.05-100 ng/mL. In terms of sensitivity of assay 0.05 ng/mL is a very low LLOQ, especially considering PM02734 is a peptide. The correlation coefficients for the calibration curves ranged from 0.9990 to 0.9999. The mean intraday and interday accuracies for all calibration standards (n = 9) ranged from 93 to 111% (< or =11% bias) in dog plasma, and the mean interday precision for all calibration standards was less than 6.4%. The mean intra- and interday assay accuracy for all quality control replicates in dog plasma (n = 9), determined at each QC level throughout the validated runs, ranged from 85-111% (< or =15% bias) and from 99-109% (< or =9% bias), respectively. The mean intra- and interday assay precision was less than 12.1 and 13.3% for all QC levels, respectively. The assay has been used to support preclinical pharmacokinetic (PK) and toxicokinetic studies. The results showed that preclinical samples could be monitored for PM02734 up to 168 h after dosing, which allowed us to identify multiple elimination phases and accurately estimate PK information.  相似文献   

11.
A high performance liquid chromatography method is presented for the determination of valproic acid levels in human plasma. The method was based on pre-column derivatization using N-(1-naphthyl)ethylenediamine as a new labeling agent. The calibration curve was linear in the investigated concentration range between 0.1 and 100 μg mL?1 and showed good accuracy and reproducibility. The assay provided a limit of quantification of 0.1 μg mL?1 for valproic acid and a limit of detection of 10 ng mL?1, respectively. The presented method was successfully applied to the determination of valproic acid levels in plasma after oral administration of 600 or 800 mg of sodium valproate.  相似文献   

12.
N‐Boc/Fmoc/Z‐N′‐formyl‐gem‐diaminoalkyl derivatives, intermediates particularly useful in the synthesis of partially modified retro‐inverso peptides, have been characterized by both positive and negative ion electrospray ionization (ESI) ion‐trap multi‐stage mass spectrometry (MSn). The MS2 collision induced dissociation (CID) spectra of the sodium adduct of the formamides derived from the corresponding N‐Fmoc/Z‐amino acids, dipeptide and tripeptide acids show the [M + Na‐NH2CHO]+ ion, arising from the loss of formamide, as the base peak. Differently, the MS2 CID spectra of [M + Na]+ ion of all the N‐Boc derivatives yield the abundant [M + Na‐C4H8]+ and [M + Na‐Boc + H]+ ions because of the loss of isobutylene and CO2 from the Boc protecting function. Useful information on the type of amino acids and their sequence in the N‐protected dipeptidyl and tripeptidyl‐N′‐formamides is provided by MS2 and subsequent MSn experiments on the respective precursor ions. The negative ion ESI mass spectra of these oligomers show, in addition to [M‐H]?, [M + HCOO]? and [M + Cl]? ions, the presence of in‐source CID fragment ions deriving from the involvement of the N‐protecting group. Furthermore, MSn spectra of [M + Cl]? ion of N‐protected dipeptide and tripeptide derivatives show characteristic fragmentations that are useful for determining the nature of the C‐terminal gem‐diamino residue. The present paper represents an initial attempt to study the ESI‐MS behavior of these important intermediates and lays the groundwork for structural‐based studies on more complex partially modified retro‐inverso peptides. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

13.
Rapid, simple and reliable HPLC/DAD and LC‐ESI‐MS methods for the simultaneous determination of baicalin and forsythin in the traditional Chinese medicinal preparation Shuanghuanglian oral liquid were described and validated. The separation condition for HPLC/DAD was optimized using a BDS hypersil C18 column (Thermo, 2.1 × 150 mm, particle size 5 μm) by gradient elution using methanol‐0.2 % ammonium acetate as the mobile phase. The suitable detection wavelength was set at 277 nm for the quantitative analysis of baicalin and forsythin in this method. Some operational parameters of the ESI interface were optimized, negative m/z 445[M?H]? for baicalin and negative m/z 593[M+CH3COO]? for forsythin, positive m/z 447[M+H]+ for baicalin and positive m/z 552[M+NH 4]+ for forsythin, respectively. These HPLC/DAD and LC‐ESI‐MS methods were validated in terms of recovery, linearity, accuracy and precision (intra‐ and inter‐day validation). These methods can be used as a complementary method for the commercial quality control of Shuanghuanglian oral liquid and its pharmaceutical preparations.  相似文献   

14.
A sensitive voltammetric technique has been developed for the determination of Fludarabine using amine‐functionalized multi walled carbon nanotubes modified glassy carbon electrode (NH2‐MWCNTs/GCE). Molecular dynamics simulations, an in silico technique, were employed to examine the properties including chemical differences of Fludarabine‐ functionalized MWCNT complexes. The redox behavior of Fludarabine was examined by cyclic, differential pulse and square wave voltammetry in a wide pH range. Cyclic voltammetric investigations emphasized that Fludarabine is irreversibly oxidized at the NH2‐MWCNTs/GCE. The electrochemical behavior of Fludarabine was also studied by cyclic voltammetry to evaluate both the kinetic (ks and Ea) and thermodynamic (ΔH, ΔG and ΔS) parameters on NH2‐MWCNTs/GCE at several temperatures. The mixed diffusion‐adsorption controlled electrochemical oxidation of Fludarabine revealed by studies at different scan rates. The experimental parameters, such as pulse amplitude, frequency, deposition potential optimized for square‐wave voltammetry. Under optimum conditions in phosphate buffer (pH 2.0), a linear calibration curve was obtained in the range of 2×10?7 M–4×10?6 M solution using adsorptive stripping square wave voltammetry. The limit of detection and limit of quantification were calculated 2.9×10?8 M and 9.68×10?8 M, respectively. The developed method was applied to the simple and rapid determination of Fludarabine from pharmaceutical formulations.  相似文献   

15.
Although bilobetin, a biflavone isolated from the leaves of Ginkgo biloba, represents a variety of pharmacological activities, to date there have been no validated determination methods for bilobetin in biological samples. Thus, we developed a liquid chromatographic method using a tandem mass spectrometry for the determination of bilobetin in rat plasma. After protein precipitation with acetonitrile including diclofenac (internal standard), the analytes were chromatographed on a reversed-phased column with a mobile phase of purified water and acetonitrile (3:7, v/v, including 0.1% formic acid). The ion transitions of the precursor to the product ion were principally deprotonated ions [M − H] at m/z 551.2 → 519.2 for bilobetin and 296.1 → 251.7 for the IS. The accuracy and precision of the assay were in accordance with US Food and Drug Administration regulations for the validation of bioanalytical methods. This analytical method was successfully applied to monitor plasma concentrations of bilobetin over time following intravenous administration in rats.  相似文献   

16.
Humantenmine (HMT), the most toxic compound isolated from Gelsemium elegans Benth , is a well‐known active herbal compound. A rapid and sensitive ultra‐performance liquid chromatography–tandem mass spectrometry (UPLC–MS/MS) method was developed and validated to estimate the absolute oral bioavailability of HMT in rats. Quantification was performed by multiple reaction monitoring using electrospray ionization operated in positive ion mode with transitions of m/z 327.14 → m/z 296.19 for HMT and m/z 323.20 → m/z 236.23 for gelsemine (internal standard, IS). The linear range of the calibration curve was 1–256 nmol/L, with a lower limit of quantification at 1 nmol/L. The accuracy of HMT ranged from 89.39 to 107.5%, and the precision was within 12.24% (RSD). Excellent recovery and negligible matrix effect were observed. HMT remained stable during storage, preparation and analytical procedures. The pharmacokinetics of HMT in rats showed that HMT reached the concentration peak at 12.50 ± 2.74 min with a peak concentration of 28.49 ± 6.65 nmol/L, and the corresponding area under the concentration–time curve (AUC0–t ) was 1142.42 ± 202.92 nmol/L min after 200 μg/kg HMT was orally administered to rats. The AUC0–t of HMT given at 20 μg/kg by tail vein administration was 1518.46 ± 192.24 nmol/L min. The calculated absolute bioavailability of HMT was 7.66%.  相似文献   

17.
In this study, we developed a method for the determination of Penicillium griseofulvum‐oriented pyripyropene A (PPPA), a selective inhibitor of acyl‐coenzyme A:cholesterol acyltransferase 2, in mouse and human plasma and validated it using liquid chromatography–tandem mass spectrometry. Pyripyropene A (PPPA) and an internal standard, carbamazepine, were separated using a Xterra MS C18 column with a mixture of acetonitrile and 0.1% formic acid as the mobile phase. The ion transitions monitored in positive‐ion mode [M + H]+ of multiple‐reaction monitoring (MRM) were m/z 148.0 from m/z 584.0 for PPPA and m/z 194.0 from m/z 237.0 for the internal standard. The detector response was specific and linear for PPPA at concentrations within the range from 1 to 5,000 ng/mL. The intra?/inter‐day precision and accuracy of the method was acceptable by the criteria for assay validation. The matrix effects of PPPA ranged from 97.6 to 104.2% and from 93.3 to 105.3% in post‐preparative mouse and human plasma samples, respectively. PPPA was also stable under various processing and/or handling conditions. Finally, PPPA concentrations in the mouse plasma samples could be measured after intravenous, intraperitoneal, or oral administration of PPPA, suggesting that the assay is useful for pharmacokinetic studies on mice and applicable to human studies.  相似文献   

18.
Electrospray ionization mass spectrometry was used to characterize several different neuropeptides, whose molecular weights ranged from 555 to 3463 Da, and to quantify endogenous methionine enkephalin (ME) and β -endorphin (β E) extracted from a human pituitary gland. Methionine enkephalin and leucine enkephalin both yield only an [M + H] + ion with electrospray mass spectrometry; the other peptides produce a series of multiply charged even-electron molecular ions of the general nature [M + nH]n+ in proportion to the number of basic amino acid units present, with no evidence of fragmentation. The electrospray mass spectra are characterized by low background noise. The quantiftcation of ME is based on a comliarison of the ion current due to the [M + H] + ion of native and of a deuterated ME ([2H5 s?4Phe]?ME) internal standard. The calibration curve is linear in the range of ca. 1-35 pmol synthetic ME. The amounts of ME determined in three separate human pituitary extracts were 9.1, 8.2, and 4.7 pmol/mg protein. The corresponding amount of ME in a canine pituitary was 39.8 pmol/mg protein. To quantify β E, the ion current due to the [M + 5H]5 + ion was monitored and compared to an external calibration curve obtained by analyzing solutions of synthetic β E in the range 5 μmol-50 pmol. The analysis of a human pituitary yielded 660 fmol β E/mg protein.  相似文献   

19.
Sparstolonin B (SsnB), a spontaneous isocoumarin compound isolated from the tuber of Scirpus yagara Ohwi. (Cyperaceae), possesses potent anti‐inflammatory and antitumor activity. In the present study, a rapid and simple UHPLC/MS/MS method for determination of SsnB in rat plasma was developed and validated. Plasma samples were pretreated by liquid–liquid extraction with ethyl acetate containing rhein as an internal standard and separated on a C18 column at 35 °C, with a gradient mobile phase consisting of acetonitrile and water containing 0.2% (v/v) formic acid within 2.1 min. MS/MS detection was accomplished in multiple reaction monitoring mode with negative electrospray ionization. The precursor–product ion transitions were m/z 266.9 [M–H]?m/z 211.0 for SsnB and m/z 283.2 [M–H]?m/z 239.0 for IS. The intra‐ and inter‐day precision (RSD) was <8.98% and the accuracy (RE) ranged from ?7.40 to 4.50%. The extraction recoveries ranged from 96.28 to 97.30%. The pharmacokinetic parameters were calculated using Win Nonlin53 software. The absolute bioavailability of SsnB was estimated to be 6.98%. The proposed method was successfully applied to a pharmacokinetic study of SsnB in rats after intravenous administration with a dose of 0.5 mg/kg and oral administration at a dose of 5 mg/kg. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

20.
Matrix‐assisted laser desorption/ionization in‐source decay (MALDI‐ISD) induces N–Cα bond cleavage via hydrogen transfer from the matrix to the peptide backbone, which produces a c′/z? fragment pair. Subsequently, the z? generates z′ and [z + matrix] fragments via further radical reactions because of the low stability of the z?. In the present study, we investigated MALDI‐ISD of a cyclic peptide. The N–Cα bond cleavage in the cyclic peptide by MALDI‐ISD produced the hydrogen‐abundant peptide radical [M + 2H]+? with a radical site on the α‐carbon atom, which then reacted with the matrix to give [M + 3H]+ and [M + H + matrix]+. For 1,5‐diaminonaphthalene (1,5‐DAN) adducts with z fragments, post‐source decay of [M + H + 1,5‐DAN]+ generated from the cyclic peptide showed predominant loss of an amino acid with 1,5‐DAN. Additionally, MALDI‐ISD with Fourier transform‐ion cyclotron resonance mass spectrometry allowed for the detection of both [M + 3H]+ and [M + H]+ with two 13C atoms. These results strongly suggested that [M + 3H]+ and [M + H + 1,5‐DAN]+ were formed by N–Cα bond cleavage with further radical reactions. As a consequence, the cleavage efficiency of the N–Cα bond during MALDI‐ISD could be estimated by the ratio of the intensity of [M + H]+ and [M + 3H]+ in the Fourier transform‐ion cyclotron resonance spectrum. Because the reduction efficiency of a matrix for the cyclic peptide cyclo(Arg‐Gly‐Asp‐D‐Phe‐Val) was correlated to its tendency to cleave the N–Cα bond in linear peptides, the present method could allow the evaluation of the efficiency of N–Cα bond cleavage for MALDI matrix development. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号