首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到10条相似文献,搜索用时 156 毫秒
1.
Analytical methods for the analysis of polychlorinated biphenyls (PCBs) and organochlorine pesticides (OCPs) are widely available and are the result of a vast amount of environmental analytical method development and research on persistent organic pollutants (POPs) over the past 30–40 years. This review summarizes procedures and examines new approaches for extraction, isolation, identification and quantification of individual congeners/isomers of the PCBs and OCPs. Critical to the successful application of this methodology is the collection, preparation, and storage of samples, as well as specific quality control and reporting criteria, and therefore these are also discussed. With the signing of the Stockholm convention on POPs and the development of global monitoring programs, there is an increased need for laboratories in developing countries to determine PCBs and OCPs. Thus, while this review attempts to summarize the current best practices for analysis of PCBs and OCPs, a major focus is the need for low-cost methods that can be easily implemented in developing countries. A “performance based” process is described whereby individual laboratories can adapt methods best suited to their situations. Access to modern capillary gas chromatography (GC) equipment with either electron capture or low-resolution mass spectrometry (MS) detection to separate and quantify OCP/PCBs is essential. However, screening of samples, especially in areas of known use of OCPs or PCBs, could be accomplished with bioanalytical methods such as specific commercially available enzyme-linked immunoabsorbent assays and thus this topic is also reviewed. New analytical techniques such two-dimensional GC (2D-GC) and “fast GC” using GC–ECD may be well-suited for broader use in routine PCB/OCP analysis in the near future given their relatively low costs and ability to provide high-resolution separations of PCB/OCPs. Procedures with low environmental impact (SPME, microscale, low solvent use, etc.) are increasingly being used and may be particularly suited to developing countries. Electronic supplementary material Supplementary material is available in the online version of this article at and is accessible for authorized users.  相似文献   

2.
有机氯农药(OCPs)和多氯联苯(PCBs)是两类重要的持久性有机污染物,可在环境介质中长期存在,并通过多种途径进入人体,导致人体的高暴露风险。OCPs和PCBs对人体存在诸多健康危害,精准定量人体内OCPs和PCBs的暴露水平是健康效应评价的关键。该研究基于固相萃取-气相色谱-串联质谱联用技术(SPE-GC-MS/MS)建立了同时检测100 μL血清中35种OCPs和PCBs的分析方法。血清样品经尿素沉淀蛋白后,采用Oasis® HLB小柱净化,正己烷-二氯甲烷混合溶液(1∶1, v/v)洗脱,氮吹近干,正己烷定容,多反应监测(MRM)模式检测,内标法定量分析。结果表明,OCPs和PCBs在0.05~50.0 ng/mL范围内线性关系良好,检出限在1.2~71.4 ng/L之间。35种目标分析物的加标回收率在72.6%~142%之间,相对标准偏差小于25%。利用所建立的方法检测了武汉市普通人群血清样本中OCPs和PCBs的浓度水平,结果表明武汉市普通人群广泛暴露于OCPs和PCBs,且以OCPs为主。有8种OCPs和7种PCBs检出率高于50%,其中p,p'-滴滴伊、p,p'-滴滴滴和甲氧滴滴涕检出率达100%,非类二噁英PCBs是PCBs的主要成分。血清中OCPs浓度随年龄增长呈升高趋势,在60岁以上存在性别差异;不同性别、年龄人群血清中PCBs浓度无统计学差异。该方法样本用量少,操作简便,具有较高的准确度和精密度,适用于环境健康研究中大量人群血清样本中痕量OCPs和PCBs的生物监测。  相似文献   

3.
母乳中多种含卤持久性有机污染物的联合检测方法   总被引:1,自引:0,他引:1  
建立了母乳中多种含卤持久性有机污染物(POPs)的联合检测方法,目标化合物主要包括六溴环十二烷(HBCDs)、多溴联苯醚(PBDEs)、多氯联苯(PCBs)和有机氯农药(OCPs)等.样品的前处理采用液液萃取、凝胶渗透色谱(GPC)净化和固相萃取(SPE)等技术,目标化合物经气相色谱-质谱联用仪(GC-MS)、液相色谱-三重四极杆串联质谱联用仪(LC-MS/MS)和气相色谱-三重四极杆串联质谱联用仪(GC-MS/MS)等进行检测.样品通过GPC除去脂肪,然后经SPE柱进一步净化并进行多组分分离,极大程度地减小了生物样品中复杂基质的干扰,适合样品量相对较小的人体样本中多种超痕量POPs的分析.应用灵敏度高、选择性更好的GC-MS/MS对样品中的PCBs和OCPs等进行分析,进一步降低基质的干扰.方法经过小牛血清加标实验验证,稳定可靠.POPs的加标回收率分别为88.7%~98.8%(PBDEs), 88.5%~92.5%(HBCDs), 67.9%~82.3%(PCBs)和81.7%~116.1%(OCPs),方法检出限分别为0.13~1.8 pg/mL(PBDEs), 0.31~1.2 pg/mL(HBCDs), 0.22~1.4 pg/mL(PCBs)和0.20~1.5 pg/mL(OCPs).采用本方法对潍坊地区20例母乳样品进行分析,结果显示,潍坊市母乳中HBCDs, PBDEs, PCBs、HCHs和DDTs的中值浓度分别为2.86, 7.76, 8.84、140和503 ng/g 脂重,此浓度水平与国内其它地区人群相当.  相似文献   

4.
A human powdered hair material (BCR 397) was tested for its content in persistent organic pollutants (POPs), such as polychlorinated biphenyls (PCBs), organochlorine pesticides (OCPs) and polybrominated diphenyl ethers (PBDEs). Using different methods, three laboratories (two from Canada and one from Belgium) analysed a powdered hair sample to evaluate some methodologies and to obtain consensus values for selected POPs. Measured values for all PCB congeners and p,p-DDE were within a relative standard deviation (RSD) of 15%. These first results contribute to the accuracy and precision for POPs quantification in hair and render test results more comparable among different laboratories.  相似文献   

5.
Persistent organic pollutants(POPs),such as dioxins,polychlorinated biphenyls(PCBs) ,and organochlorine pesticides(OCPs),which are synthetic chemicals or by-products with an intrinsic resistance to natural degradation processes,are released into the environment,resulting in the widespread dispersal and accumulation in the environment,as well as in human and ecological food chains.Due to their ubiquity in the environment and lipophilic properties,there is emerging concern over the potential risks of human ex...  相似文献   

6.
建立了贻贝中有机氯农药(OCPs)和多氯联苯(PCBs)标准物质的研制和定值方法,该研究对我国开展环境生物标准物质的研制具有重要的方法学借鉴价值。该标准物质样品为采自大连湾海域的贻贝,其定值目标物包括18种OCPs和16种PCBs,采用的定值测量方法是目前世界上最权威、最准确的同位素稀释-高分辨气相色谱/高分辨质谱联用法(ID-HRGC/HRMS)。所研制的标准物质具有定值目标物种类多、不确定度较小(约10%)等特点。该标准物质是目前国际上唯一一种采用同位素稀释高分辨质谱法进行定值的底栖生物中OCPs标准物质,于2012年3月通过了国家一级标准物质的终审,并于2012年6月被国家质量监督检验检疫总局批准为国家一级标准物质(GBW10069)。该标准物质可用于食品安全控制、环境监测、质量检测等领域相关分析方法的评价、测量质量控制及技术仲裁检验等。  相似文献   

7.
Organochlorine pesticide (OCP) residues in foods have been of concern for several decades. However, the analysis of some of the OCPs and their metabolites or derivatives, such as endrin aldehyde, endrin ketone, nonachlor, etc. in fatty foods (including foods of animal and plant origin), was not commonly included in routine monitoring programme. Recently, the Stockholm Convention introduced nine plus one new persistent organic pollutants (POPs) that included chlordecone and some other OCPs. Is there a method available that can analyze both traditional OCPs, together with their metabolites and derivatives in fatty foods? Furthermore, is there a suitable method that can monitor OCPs and the newly added POPs including chlordecone in fatty foods together in a pot? This review aims to provide some background information to answer these questions.  相似文献   

8.
Polychlorinated biphenyls (PCBs) and organochlorine pesticides (OCPs), such as DDT and analogues, hexachlorocyclohexane (HCH) isomers and hexachlorobenzene (HCB), were measured in surface soils and sediments from Eastern Romania. Thirty-nine soil samples from the forested zone, eight soil samples from a municipal waste-disposal site, and 10 sediment samples from the Bahlui River along the Iassy city were analysed using accelerated solvent extraction (ASE) and gas chromatography coupled to electron capture detection or mass spectrometry. The low mean concentrations of OCPs (11–31 and 22–84?ng?g?1 for HCHs and DDTs, respectively) and PCBs (8–43?ng?g?1) in soil samples from the forested zone suggest that contamination at most of these sites occurred predominantly through atmospheric transport from zones where these compounds were used and subsequently through atmospheric deposition. Contrarily, soil samples collected in the vicinity of a waste-disposal site near Iassy contained higher mean levels of PCBs (278?ng?g?1, range 34–1132?ng?g?1) than OCPs (6 and 101?ng?g?1 of soil for HCHs and DDTs, respectively). The sediment samples collected along the Bahlui river throughout the Iassy city revealed higher mean levels of PCBs (59?ng?g?1, range 24–158?ng?g?1) compared with OCP levels (2 and 37?ng?g?1 of soil for HCHs and DDTs, respectively). Furthermore, PCB profiles and concentrations in the sediment samples varied considerably along the river due to a wide variety of sources, such as different industries and waste sites. Although their sources are difficult to evaluate, the presence of POPs at most sites (especially at the waste-disposal site) may constitute a potential health hazard.  相似文献   

9.
A method to determine 8 polychlorinated biphenyls (PCBs), 23 organochlorine pesticides (OCPs) and 16 polycyclic aromatic hydrocarbons (PAHs) was described using dispersive liquid–liquid microextraction (DLLME) of a small amount of plasma or serum sample and gas chromatography–tandem mass spectrometry (GC–MS/MS). The appropriate selection of the extraction solvent and dispersing solvent contributes to a high extraction yield and a clean extract. To verify the developed method, the interference, linearity of the calibration curve, detection limit, precision and accuracy were evaluated. The calibration curves were linear by 2–3 orders of magnitude with correlation coefficients above 0.997 in all cases. The LODs of PCBs, OCPs and PAHs were measured in the ranges of 0.0006–0.0029, 0.001–0.029 and 0.0002–0.012 ng/mL. The intraday precision achieved by this method was 2.19–10.3% (PCBs), 1.65–14.3% (OCPs) and 0.91–12.8% (PAHs), and the intraday accuracy 1.56–7.37% (PCBs), 2.34–19.6% (OCPs) and 1.49–15.7% (PAHs). The advantage of this method is that the analysis of PCBs, OCPs, and PAHs can be performed in a single chromatographic run, and the low detection limit enables monitoring of target substances in low exposure general public samples, and the analysis procedure is relatively simple and fast.  相似文献   

10.
A simple and novel analytical method for quantifying persistent organic pollutants (POPs) in marine sediments has been developed using microwave assisted solvent extraction (MASE) and liquid-phase microextraction (LPME) using hollow fibre membrane (HFM). POPs studied included twelve organochlorine pesticides (OCP) and eight polychlorinated biphenyl (PCB) congeners. MASE was used for the extraction of POPs from 1 g of sediment using 10 ml of ultrapure water at 600 W for 20 min at 80 degrees C. The extract was subsequently subjected to a single step LPME-HFM cleanup and enrichment procedure. Recovery varied between 73 and 111% for OCPs; and 86-110% for PCBs, and exceeded levels achieved for conventional multi-step Soxhlet extraction coupled with solid-phase extraction. The method detection limit for each POP analyte ranged from 0.07 to 0.70 ng g(-1), and peak areas were proportional to analyte concentrations in the range of 5-500 ng g(-1). Relative standard deviations of less than 20% was obtained, based on triplicate sample analysis. The optimized technique was successfully applied to POP analysis of marine sediments collected from the northeastern and southwestern areas of Singapore's coastal environment.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号