1.
A novel method is presented to detect DNA fragments separated by capillary electrophoresis (CE) with laser-induced fluorescence (LIF) detection using inverse-flow derivatization. In electrophoresis, the intercalating dye, thiazol orange was only added to the separation buffer at the positive polarity. The negatively charged DNA fragments migrated from the negative polarity to the positive polarity, while the positively charged dye migrated in the opposite direction. When DNA fragments met with dye ions, the DNA–dye complexes were formed. The complexes continued migrating to the positive end, due to their net negative charges. When the complexes passed through the detection window, the fluorescent signals were generated. Importantly, DNA fragments migrated as their native state before DNA–dye complexes were formed. This procedure was used to detect double stranded DNA (dsDNA) and single stranded DNA (ssDNA) fragments, and polymerase chain reaction (PCR) products. The excellent resolution and good reproducibility of DNA fragments were achieved in non-gel sieving medium. This procedure may be useful in genetic mutation/polymorphism detections.  相似文献   

2.
Single strand conformation polymorphism (SSCP) analysis of the N-ras oncogene was achieved by capillary electrophoresis with a laser-induced fluorescence detector (CE-LIF) using methylcellulose as a molecular sieving agent. The PCR-amplified N-ras oncogene, which is known to have a point mutation at codon 61 in the neuroblastoma, was investigated by CE-LIF combined with SSCP (SSCP-CE-LIF). A mixture of wild- and mutant-type single strand DNA fragments (103 bp) of the N-ras oncogene was separated by buffer solution containing 1.0% methylcellulose and 0.2 microM fluorescent dye (YO-PRO-1) at 25 degrees C. The SSCP-CE-LIF technique gave good resolution for wild- and mutant-type single strand DNA fragments with separation completed within 7 min. SSCP analysis using a CE system with a LIF detector was successfully applied to the detection of the one point mutation on the N-ras oncogene.  相似文献   

3.
CE‐SSCP analysis is a well‐established DNA separation method that is based on variations in mobility caused by sequence‐induced differences in the conformation of single‐stranded DNA. The resolution of CE‐SSCP analysis was improved by using a Pluronic polymer matrix, and it has been successfully applied in various genetic analyses. Because the Pluronic polymer forms a micellar cubic structure in the capillary, it provides a stable internal structure for high‐resolution CE‐SSCP analysis. We hypothesized that formation of micellar cubic structure is influenced by the end hydroxyl group of the Pluronic polymer, which affords structural stability through hydrogen bonding. To test this hypothesis, the hydroxyl group was halogenated to eliminate the hydrogen bonding without disturbing the polarity of polymer matrix. CE‐SSCP resolution of two DNA fragments with a single base difference was significantly worse in the halogenated polymer matrices due to band broadening. The viscoelastic properties of control (which has hydroxyl group), chlorinated, and brominated F108 solution upon heating were also investigated by rheological experiments, and we found that gelation was significantly associated with resolution. In this series of experiments, the effect of the hydroxyl group in Pluronic polymer matrix on separation resolution of CE‐SSCP analysis was demonstrated.  相似文献   

4.
RNA viruses display the highest replication error rate in our biosphere, leading to highly diverse viral populations termed quasispecies. The gold standard method for detection and quantification of variants in a quasispecies is cloning and sequencing, but it is expensive, laborious and time consuming. Therefore, other mutation detection approaches, including SSCP, are often used. In this study, we demonstrate development and the usage of a CE‐SSCP method for quantification of two nearly identical viral variants in heterogenic population of a mumps virus strain and its comparison to RFLP‐CE‐fragment length analysis (RFLP‐CE‐FLA). Analyzed PCR fragments were of the same size (245 bp) with one difference in their nucleotide sequence. The limit of detection of both methods was at 5% of the minor variant. When PCR amplicons of the two variants were pooled, methods' results were very similar. On the contrary, the quantification results of samples in which variants were mixed prior to PCR showed substantial difference between the two methods. Our results indicate that although both methods can be used for detection and monitoring of a specific mutation within a viral population, caution should be taken when quantitative analysis of complex samples is based solely on results of one method.  相似文献   

5.
Vahedi G  Kaler K  Backhouse CJ 《Electrophoresis》2004,25(14):2346-2356
This work integrates rapid techniques for mutation detection by producing single-stranded DNA and (renatured) double-stranded DNA on-chip, labeling these with fluorescent DNA stains and then performing two complementary methods of mutation detection-single stranded conformation polymorphism (SSCP) analysis and heteroduplex analysis (HA). This involves the denaturation of double-stranded polymerase chain reaction (PCR) product into single-stranded DNA, the mutation analysis of the single-stranded DNA by SSCP and the rehybridized double-stranded DNA by HA. These steps were performed entirely on-chip within several minutes of operation. The combination of these two mutation detection methods on-chip provides a highly sensitive method of mutation detection for either genotyping or screening. Many mutation analysis methods rely upon fluorescently labeled samples from a PCR with fluorescently labeled primers. By labeling on-chip we not only attain improved signal strength, but the method is considerably more versatile. Although we used PCR products in this work, this method could be used to analyze DNA from any source. We believe that this combination of several procedures on a single chip represents a significant step in the development of higher levels of integration upon microfluidic devices.  相似文献   

6.
Although CE‐SSCP analysis combined with 16S ribosomal RNA gene‐specific PCR has enormous potential as a simple and versatile pathogen detection technique, low resolution of CE‐SSCP causes the limited application. Among the experimental conditions affecting the resolution, the polymer matrix is considered to be most critical to improve the resolution of CE‐SSCP analysis. However, due to the peak broadening caused by the interaction between hydrophobic moiety of polymer matrices and DNA, conventional polymer matrices are not ideal for CE‐SSCP analysis. A poly(ethyleneoxide)‐poly(propyleneoxide)‐poly(ethyleneoxide) (PEO‐PPO‐PEO) triblock copolymer, with dynamic coating ability and a propensity to form micelles to minimize exposure of hydrophobic PPO block to DNA, can be an alternative matrix. In this study, we examined the resolution of CE‐SSCP analysis using the PEO‐PPO‐PEO triblock copolymer as the polymer matrix and four same‐sized DNA fragments of similar sequence content. Among 48 commercially available PEO‐PPO‐PEO triblock copolymers, three were selected due to their transparency in the operable range of viscosity and PEO137PPO43PEO137 exhibited the most effective separation. Significant improvement in resolution allowed discrimination of the similar sequences, thus greatly facilitated CE‐SSCP analysis compared to the conventional polymer matrix. The results indicate that PEO‐PPO‐PEO triblock copolymer may serve as an ideal matrix for high‐resolution CE‐SSCP analysis.  相似文献   

7.
《Electrophoresis》2017,38(3-4):507-512
LIF detection often requires labeling of analytes with fluorophores; and fast fluorescent derivatization is valuable for high‐throughput analysis with flow‐gated CE. Here, we report a fast fluorescein‐labeling scheme for amino acid neurotransmitters, which were then rapidly separated and detected in flow‐gated CE. This scheme was based on the reaction between primary amines and o‐phthalaldehyde in the presence of a fluorescent thiol, 2‐((5‐fluoresceinyl)aminocarbonyl)ethyl mercaptan (FACE‐SH). The short reaction time (<30 s) was suited for on‐line mixing and derivatization that was directly coupled with flow‐gated CE for rapid electrophoretic separation and sensitive LIF detection. To maintain the effective concentration of reactive FACE‐SH, Tris(2‐carboxyethyl)phosphine was added to the derivatization reagents to prevent thiol loss due to oxidation. This labeling scheme was applied to the detection of neurotransmitters by coupling in vitro microdialysis with online derivatization and flow‐gated CE. It is also anticipated that this fluorophore tagging scheme would be valuable for on‐chip labeling of proteins retained on support in SPE.  相似文献   

8.
Capillary electrophoresis (CE) is a versatile analytical platform widely used for nucleic acids analysis. Its applications in research and diagnostics include scanning and screening for mutations and polymorphisms by such reliable methods as single-strand conformation polymorphism (SSCP), heteroduplex analysis (HA), and combined SSCP/HA. This study, aimed at the further development of these methods, is focused on detailed sample-media characteristics. Factors affecting single-strand conformer stability and DNA intake efficiency were analyzed. The sample media optimal for efficient mutation or SNP detection were determined, and complex SSCP-CE patterns arising from unpurified PCR products were explained. It turns out, that the nondenaturing aqueous media assure both efficient DNA intake, and single-strand conformers stability required for the SSCP and combined SSCP/HA. The results of this study are applicable to all these areas of biomedical research, in which capillary electrophoresis is used for the characterization of nucleic acids.  相似文献   

9.
10.
Three methods [capillary electrophoresis (CE)-allele-specific PCR, CE-single-strand conformation polymorphism (SSCP) and CE-cleavase fragment length polymorphism (CFLP)] were developed in order to effect rapid and specific analysis of the vero toxin (VT)1 and VT2 genes of O157. The allele-specific polymerase chain reaction (PCR) method, which utilized specific duplex PCR with specific primers for VT1 and VT2, showed that VT1 and VT2 consisted of 174 and 128 bp, respectively. Subsequent CE analysis was carried out. Separation time was 4 min. SSCP, which utilized one primer set which reacted with both VT1 and VT2 in the PCR method, was followed by CE analysis of secondary structure of single-strand DNA. Two genes could be analyzed in approximately 18 min. CFLP, like SSCP, is a method for detecting mutation-induced changes in secondary structure of single-stranded DNA. The endonuclease cleavase I recognizes and cleaves the 5' side of hairpin loops in self-annealed single-strand DNA of PCR product 169 bp obtained from VT1 and VT2. The produced DNA fragments are analyzed by CE and the electrophelogram reveals a sequence-specific CFLP. Separation time was 6 min. These techniques are suitable for the detection and the identification of O157.  相似文献   

11.
In the present study we investigated whether single-strand conformational polymorphism (SSCP) and polyacrylamide gel electrophoresis (PAGE) could be used for the identification of the CFTR DeltaF508 gene mutation, which is commonest in the Greek population. Using DNA from patients carrying this mutation, the appropriate 98 bp region of the CFTR gene was amplified by PCR and the reaction products were analysed by non-radioactive SSCP-electrophoresis using silver staining for band visualization and non-denaturating PAGE to confirm the results. SSCP electrophoretic analysis has been optimized for several parameters in order to achieve the best resolution. Single-strand DNA fragments gave a reproducible pattern of bands, characteristic for the particular mutation. Comparison of the obtain patterns with control samples allowed the detection of the DeltaF508 mutation in the patients studied by SSCP assay and these results were confirmed by the independent method of PAGE. Although SSCP and PAGE can be used for detection of this mutation, PAGE resulted in more distinct patterns than SSCP. It is, therefore, proposed that PAGE can be reliably used for the detection and identification of such a mutation in patients provided that suitable controls are available. The applicability of PAGE to identification of the mutation in carriers, particularly useful for population screening, is also discussed.  相似文献   

12.
Numerous mutations and polymorphisms in human genes remain to be identified using reliable methods. Of the available mutation scanning methods those dependent on structural change-induced mobility shifts are highly effective. Their efficiency is, however, DNA length-sensitive and the reasons for that are poorly understood. In this study, we explain why scanning genes for mutations is less effective in longer DNA fragments, and reveal the factors which are behind this effect. We have performed a systematic analysis of the same sequence variants of exon 11 of the BRCA1 gene in DNA fragments of three different lengths using the combined single-strand conformation polymorphism (SSCP) and heteroduplex analysis (DA) by capillary electrophoresis (CE). There are two major structural factors responsible for the reduced mutation detection rate in long amplicons. The first is increased contribution from other secondary structure modules and domains in longer fragments, which mask the structural change induced by the mutation. The second is higher frequency of single-nucleotide polymorphisms (SNPs) including common polymorphisms in longer fragments. This makes it necessary to distinguish the structural effect of the mutation from that of each polymorphic variant, which is often difficult to achieve. Taking these factors into account, an efficient scanning of genes for sequence variants by conformation-sensitive methods may be performed.  相似文献   

13.
We developed a method for the analysis of multiplexed double-stranded DNA (dsDNA) samples complexed to various intercalating dyes using entangled polymer solution. A commercial single-column capillary electrophoresis (CE) instrument with diode array detection was used for multiplexed detection of DNA samples by addition of intercalating fluorescent molecules. A Phi X174HinfI and a pGEM DNA ladder (1 mg/mL) were used for the electrophoretic separation of dsDNA fragments ranging in size from 24 to 726 and 36 to 2645 bp, respectively. The results suggested that simultaneous electrophoretic separation of different DNA ladders multiplexed with different dyes could be performed in the same capillary yielding fast DNA sizing separations. CE analysis, which is often overpowered by slab gel in sample throughput, could now overcome this disadvantage by allowing multiplexed sample analysis in a fraction of the time needed for slab gel analysis. The separation efficiency of stained DNA molecules with both dyes were dramatically improved with buffers containing a large cation such as tetrapentylammonium ion (Npe(4) (+)) as the only cation in the buffer.  相似文献   

14.
Developing diagnostic tools based on the application of known disease/phenotype‐associated copy number variations (CNVs) requires the capacity to measure CNVs in a multiplex format with sufficient reliability and methodological simplicity. In this study, we developed a reliable and user‐friendly multiplex CNV detection method, termed stuffer‐free MLPA‐CE‐SSCP, that combines a variation of multiplex ligation‐dependent probe amplification (MLPA) with CE‐SSCP. In this variation, MLPA probes were designed without the conventionally required stuffer sequences. To separate the similar‐sized stuffer‐free MLPA products, we adopted CE‐SSCP rather than length‐dependent conventional CE analysis. An examination of the genomic DNA from five cell lines known to vary in X‐chromosome copy number (1–5) revealed that copy number determinations using stuffer‐free MLPA‐CE‐SSCP were more accurate than those of conventional MLPA, and the CV of the measured copy numbers was significantly lower. Applying our system to measure the CNVs on autosomes between two HapMap individuals, we found that all peaks for CNV targets showed the expected copy number changes. Taken together, our results indicate that this new strategy can overcome the limitations of conventional MLPA, which are mainly related to long probe length and difficulties of probe preparation.  相似文献   

15.
The polymerase chain reaction-single-strand conformation polymorphism (PCR-SSCP) technique is developed for the detection of point mutations in DNA samples, and is very useful in the research of tumors. The traditional SSCP was carried out with slab gel electrophoresis (SGE), but this is time-consuming and labor-intensive, particularly for clinical diagnoses. We have developed a capillary electrophoresis (CE) method for SSCP detection with a linear polyacrylamide gel solution as the sieving matrix. Twenty colon tumor samples were detected with SSCP-CE and the point mutation in exon 7 of the p53 gene was found in six of the samples. Based on the sequencing results, the accuracy of SSCP-CE was better than that of SSCP-SGE. We hope this rapid and convenient method could be applied in the clinical diagnosis of tumors soon.  相似文献   

16.
With the complete sequencing of the human genome, there is a growing need for rapid, highly sensitive genetic mutation detection methods suitable for clinical implementation. DNA-based diagnostics such as single-strand conformational polymorphism (SSCP) and heteroduplex analysis (HA) are commonly used in research laboratories to screen for mutations, but the slab gel electrophoresis (SGE) format is ill-suited for routine clinical use. The translation of these assays from SGE to microfluidic chips offers significant speed, cost, and sensitivity advantages; however, numerous parameters must be optimized to provide highly sensitive mutation detection. Here we present a methodical study of system parameters including polymer matrix, wall coating, analysis temperature, and electric field strengths on the effectiveness of mutation detection by tandem SSCP/HA for DNA samples from exons 5-9 of the p53 gene. The effects of polymer matrix concentration and average molar mass were studied for linear polyacrylamide (LPA) solutions. We determined that a matrix of 8% w/v 600 kDa LPA provides the most reliable SSCP/HA mutation detection on chips. The inclusion of a small amount of the dynamic wall-coating polymer poly-N-hydroxyethylacrylamide in the matrix substantially improves the resolution of SSCP conformers and extends the coating lifetime. We investigated electrophoresis temperatures between 17 and 35 degrees C and found that the lowest temperature accessible on our chip electrophoresis system gives the best condition for high sensitivity of the tandem SSCP/HA method, especially for the SSCP conformers. Finally, the use of electrical fields between 350 and 450 V/cm provided rapid separations (<10 min) with well-resolved DNA peaks for both SSCP and HA.  相似文献   

17.
Rapid and simple analysis for the multiple target pathogens is critical for patient management. CE‐SSCP analysis on a microchip provides high speed, high sensitivity, and a portable genetic analysis platform in molecular diagnostic fields. The capability of separating ssDNA molecules in a capillary electrophoretic microchannel with high resolution is a critical issue to perform the precise interpretation in the electropherogram. In this study, we explored the potential of poly(ethyleneoxide)‐poly(propyleneoxide)‐poly(ethyleneoxide) (PEO‐PPO‐PEO) triblock copolymer as a sieving matrix for CE‐SSCP analysis on a microdevice. To demonstrate the superior resolving power of PEO‐PPO‐PEO copolymers, 255‐bp PCR amplicons obtained from 16S ribosomal RNA genes of four bacterial species, namely Proteus mirabilis, Haemophilus ducreyi, Pseudomonas aeruginosa, and Neisseria meningitidis, were analyzed in the PEO‐PPO‐PEO matrix in comparison with 5% linear polyacrylamide and commercial GeneScan? gel. Due to enhanced dynamic coating and sieving ability, PEO‐PPO‐PEO copolymer displayed fourfold enhancement of resolving power in the CE‐SSCP to separate same‐sized DNA molecules. Fivefold input of genomic DNA of P. aeruginosa and/or N. meningitidis produced proportionally increased corresponding amplicon peaks, enabling correct quantitative analysis in the pathogen detection. Besides the high‐resolution sieving capability, a facile loading and replenishment of gel in the microchannel due to thermally reversible gelation property makes PEO‐PPO‐PEO triblock copolymer an excellent matrix in the CE‐SSCP analysis on the microdevice.  相似文献   

18.
The identification of the specific mutation causing an inherited disease in a patient is the framework for the development of a rationale for therapy and of DNA-based tests for screening relatives. We present here a review of the single-strand conformational polymorphism (SSCP) method, which allows DNA fragments that have been amplified with specific primers and PCR to be scanned rapidly for any sequence variation. The general principles of the method are described, as are the major factors that must be considered in developing an optimal SSCP strategy, namely length of the PCR fragment and the temperature of the gel run. Options for sample denaturing gel characteristics and detection of DNA fragments are discussed. In addition, several modifications are presented that have been developed for high-throughput mutational analysis. The application of these techniques to screen for mutations in the LDL receptor gene in patients with familial hypercholesterolemia are described.  相似文献   

19.
20.
CE allows for highly reproducible analysis of DNA fragments which can be used to detect DNA mutations including SNPs. We have utilized a simple and direct CE analysis method for SNP analysis called conformation-sensitive CE (CSCE), based on the principle of single nucleotide different to produce conformational changes in the mildly denaturing solvent system. This method was applied to analysis of a mutation in the promoter region of the hMSH2 gene. This gene belongs to the human DNA mismatch repair system, which is responsible for recognizing and repairing mispaired nucleotides, and mutations in the hMSH2 gene are known to cause hereditary nonpolyposis colorectal cancer (HNPCC). PCR fragments generated from the promoter region of the hMSH2 gene, displaying either a C/C homozygote, C/T heterozygote, or T/T homozygote genotype, did not require further pretreatment before electrokinetic injection. The CE separation, using a 1xTris-borate-EDTA (TBE) buffer containing 3% w/v hydroxylethyl cellulose (HEC) and 6 M urea, was performed under reverse polarity with a separation temperature of 15 degrees C. The genotypes of 204 healthy volunteers and 13 colorectal cancer patients were determined using CSCE, and the results confirmed by DNA sequencing. While the CSCE separations were shown to be highly reproducible and sensitive for screening large populations, no correlation was observed between cancer patients and this hMSH2 gene polymorphism.  相似文献   