首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 851 毫秒
1.
《Electroanalysis》2004,16(11):922-927
A novel chloride PVC‐based membrane sensor based on a ruthenium(III) Schiff's base complex, as an excellent neutral carrier, has been developed. The ruthenium complex, in combination with a ketonic plasticizer and a cationic additive led to ISEs with fundamental characteristics, such as slope sensitivity, short response times and selectivity coefficients, which were sufficient for practical applications. The sensor with composition of 30% PVC, 62% benzyl acetate, 5% ruthenium(III) Schiff's base complex and 3% hexadecyltrimethyl ammonium bromide displays near‐Nernstian behavior in a wide concentration range (1.0×10?1–3.0×10?6 M with slope of ?54.5±0.5) with a detection limit of 2.0×10?6 M (71.0 ng per mL). The response of the electrode is independent on pH in the range of 4.0–10.0 and can it be used for at least ten weeks. The proposed electrode shows a very short response time (<20 s) in whole concentration range. The sensor displays high selectivity toward chloride ions over several organic and inorganic anions. It was successfully applied for the determination of chloride in serum samples. It was also used as an indicator electrode in the potentiometric titration of chloride ions with silver nitrate solution.  相似文献   

2.
In this study, a new poly(vinyl chloride) (PVC) membrane sensor for La3+ ion based on 2,2′-dithiodipyridine as an ion carrier was prepared. This electrode revealed good selectivity for La3+ over a wide variety of other metal ions. Effects of experimental parameters such as membrane composition, nature and amount of plasticizer, the amount of additive and concentration of internal solution on the potential response of La3+ sensor were investigated. The electrode exhibited a Nernstian slope of 20.0 ± 1.0 mV per decade of La3+ over a concentration range of 7.1 × 10−6 to 2.2 × 10−2 M of La3+ in the pH range 3.3-8.0. The response time was about 7 s and the detection limit was 3.1 × 10−6 M. The electrode can be used for at least 2 months without a considerable divergence in potential. The proposed electrode was used as an indicator electrode in potentiometric titration of oxalate and fluoride ions and was applied for determination of F ion in mouthwash solution.  相似文献   

3.
A PVC membrane electrode for Ni2+ ions based on a recently synthesized mercapto compound, as an ionophore was prepared. The electrode exhibits a Nernstian slope of 28-30 mV per concentration decade at wide concentration range of (1.0×10−2-1.0×10−7 M). It has a fast response time of <15 s and can be used for at least 4 weeks. The potentiometric response is independent of the pH of the test solution in the pH range 5-8.5. The proposed electrode revealed good selectivities over a wide variety of other cations including alkali, alkaline earth, transition and heavy metal ions. It was successfully applied to the direct determination and potentiometric titration of nickel ion with EDTA.  相似文献   

4.
Gholivand MB  Mozaffari Y 《Talanta》2003,59(2):399-407
A PVC membrane electrode based on bis(2-nitrophenyl)disulfide carrier exhibits a very good response for Zn2+ in a wide concentration range (from 2.9×10−7 to 3.2×10−2 mol l−1) with a slope of 29.9±0.4 mV per decade of Zn2+ concentration. The response time of the sensor is about 10 s and the membrane can be used for more than 3 months without any observed divergence in potentials. The proposed sensor exhibits very good selectivity for Zn2+ over many cations and can be used in a wide pH range (2-9). This assembly served also as an indicator electrode in potentiometric titrations involving zinc ions and direct potentiometric determination of zinc ions in real and synthetic samples.  相似文献   

5.
A novel potentiometric zirconium - PVC matrix membrane sensor incorporating bis(diphenylphosphino) ferrocene as an electroactive material and tris(2-ethylhexyl)phosphate as solvent mediator is described. In mixed acetate buffer solution of pH 4.8, the sensor displays a rapid and linear response for zirconium ion over the concentration range 1.0 × 10−1 to 1.0 × 10−7 mol L−1 with a good slope of 59.7 ± 0.3 mV per decade and detection limit 1.8 × 10−8 mol L−1. The best performance was obtained with membrane composition 33% PVC, 65% TEHP, 1% NaTPB and 1% ionophore. The proposed electrode revealed excellent selectivity for zirconium ion over a wide variety of alkali, alkaline earth, transition and heavy metal ions and could be used in a pH range of 4.15-7.8. The electrode was applied for at least 1 month without any considerable divergence in the potential responses. The practical utility of the electrode has been demonstrated by its use as an indicator electrode in the potentiometric titration of zirconium ions with sodium fluoride and in determination of zirconium ion in some alloy, tape and waste water samples.  相似文献   

6.
A PVC membrane vanadyl (VO2+) ion-selective electrode was constructed using 1,8-diaminonaphthalen (DAN) as a neutral carrier. The electrode shows good Nernstian response for VO2+ ions over a wide concentration range (1.0×10−1-1.0×10−5 M). The optimum composition of the membrane was 55 wt.% poly(vinylchloride), 35 wt.% 2-nitrophenyl octyl ether (NPOE), 5 wt.% ionophore, and 5 wt.% potassium tetrakis(p-chlorophenyl)borate (KTpClPB). It has relatively fast response time and can be used at least for 5 weeks without any considerable divergence in potentials. The proposed electrode revealed relatively good selectivity for VO2+ over wide variety of other metal ions. The electrode was used for the potentiometric titration of VO2+ ions with EDTA.  相似文献   

7.
A PVC membrane electrode for copper ion based on 1,3-dithiane,2-(4-methoxy phenyl) as ionophore and o-nitrophenyl octyl ether as a plasticizer is demonstrated. The electrode exhibits a Nernstian slope of 29.5±1 mV per decade in a linear range of 3.0×10−6 to 5.0×10−2 M for Cu2+ ion. The detection limit of this electrode is 1.0×10−6 mol/l. This sensor has a very short response time of about 5 s and could be used in a pH range of 4.0-7.0. High selectivity was obtained over a wide variety of metal ions. The proposed electrode was successfully applied as an indicator electrode for the potentiometric titration of copper ion with EDTA and for the direct determination of copper in river water.  相似文献   

8.
Mittal SK  Kumar SK  Sharma HK 《Talanta》2004,62(4):801-805
A new ion-selective electrode (ISE) based on dicyclohexano-18-crown-6 (DC18C6) as a neutral carrier is developed for lanthanum(III) ions. The electrode comprises of dicyclohexano-18-crown-6 (6%), PVC (33%), and ortho-nitrophenyl octyl ether (o-NPOE) (61%). The electrode shows a linear dynamic response in the concentration range of 10−6 to 10−1 M with a Nernstian slope of 19 mV per decade and a detection limit as 5×10−7 M. It has a response time of <30 s and can be used for at least 5 months without any significant divergence in potentials. The selectivity coefficients for mono-, di-, and trivalent cations indicate good selectivity for La(III) ions over a large number of interfering cations. The sensor has been used as an indicator electrode in the potentiometric titrations of La(III) with EDTA. The membrane is successfully applied in partially non-aqueous medium. It can be used in the pH range 4-9.  相似文献   

9.
Nickel(II)-selective sensor based on dibenzo-18-crown-6 in PVC matrix   总被引:1,自引:0,他引:1  
Nickel(II)-selective sensors have been fabricated from poly(vinyl chloride) (PVC) matrix membranes containing neutral carrier dibenzo-18-crown-6 as electroactive material, sodium tetraphenylborate (NaTPB) as an anion excluder and tris-(2-ethylhexyl) phosphate (TEHP) as plasticizing solvent mediator. The membrane having the composition of crown ether:NaTPB:TEHP:PVC in the ratio 10:1:200:200 (w/w) exhibits best results with linear potential response in the concentration range of 1.0 × 10−5 to 1.0 × 10−1 M and a Nernstian slope of 29.5 mV/decade of activity between 2.6 and 6.8. The sensor exhibits a fast response time of <25 s, is inert towards non-aqueous medium up to 15% (v/v) and was used over a period of 4 months with good reproducibility. It is selective over a number of mono-, bi- and trivalent cations. The practical utility of the sensor has been demonstrated by using it as an indicator electrode in the potentiometric titration of Ni2+ against EDTA and also for the estimation of Ni2+ in some Indian brand chocolates.  相似文献   

10.
A novel PVC-based membrane sensor based on vanadyl salophen (VNSP) for determination of trace amounts of monohydrogenphosphate (MHP) ions is introduced. The electrode revealed Nernstian response towards monohydrogenphosphate over the wide concentration range from 1.0×10−1 to 1.0×10−6 M at the pH of 8.2. The effect of solvent mediator, cationic additives and amount of ion-carrier on the behavior of the sensor was investigated. The sensor shows a short response time (<20 s) in the whole concentration ranges. The selectivity of the electrode is very high, and it can be used for detection of trace amounts of monohydrogenphosphate in the presence of large amounts of other anions. The detection limit of the electrode was 5.0×10−7 M (48 ng/ml) and it could be used for 14 weeks without any measurable changes in the slope. The potentiometric selectivity coefficients data revealed negligible interference from 16 common anions. It was successfully applied for the direct determination of monohydrogenphosphate in fertilizer samples and, as an indicator electrode, in potentiometric titration of HPO42− ion with barium nitrate.  相似文献   

11.
In this work, a highly selective and sensitive monohydrogen phosphate membrane sensor based on a molybdenum bis(2-hydroxyanil) acetylacetonate complex (MAA) is reported. The sensor shows a linear dynamic range between 1.0 × 10−1 and 1.0 × 10−7 M, with a nice Nernstian behavior (−29.5 ± 0.3 mV decade−1) in pH of 8.2. The detection limit of the electrode is 6.0 × 10−8 M (∼6 ppb). The best performance was obtained with a membrane composition of 32% poly(vinyl chloride), 58% benzyl acetate, 2% hexadecyltrimethylammonium bromide and 8% MAA. The sensor possesses the advantages of short response time, low detection limit and especially, very good selectivity towards a large number of organic and inorganic anions including salicylate, citrate, tartarate, acetate, oxalate, fluoride, chloride, bromide, iodide, sulfite, sulfate, nitrate, nitrite, cyanide, thiocyanate, perchlorate, metavanadate, and bicarbonate ions. The electrode can be used for at least 10 weeks without any considerable divergence in its slope and detection limit. It was used as an indicator electrode in potentiometric titration of monohydrogenphosphate ion with barium chloride. The proposed sensor was successfully applied to direct determination of monohydrogenphosphate in two fertilizer samples (NPK).  相似文献   

12.
The nitrite-selective PVC membrane electrodes prepared with lipophilic long-chain tetraalkyltin compounds as neutral carrier show selectivity patterns significantly different from those obtained with classical anion-exchangers. The potentiometric selectivity coefficient for nitrite ion with respect to nitrate ion has been improved by about four orders of magnitude. The linear response range of the electrode based on tetralauryltin (TLT) is from 1 × 10?1M down to 2×10?5M with a detection limit of 5 × 10?6M. The Nernstian response of the electrode in the medium of pH≥7 gradually changes to a doubled super-Nernstian response when the solution turns slightly acidic. The change of the response slope has a closely relation with the stepwise complex-formation equilibrium of the carrier with the anion involved, which was experimentally studied by using ultraviolet spectroscopy. An explanation of the anomalous response behavior as well as the curve form of the potential-pH plot is given.  相似文献   

13.
The two chromium chelates of Schiff bases, N-(acetoacetanilide)-1,2-diaminoethane (L1) and N,N′-bis(acetoacetanilide)-triethylenetetraammine (L2), have been synthesized and explored as neutral ionophores for preparing poly(vinylchloride) (PVC) based membrane sensors selective to Cr(III). The addition of lipophilic anion excluder (NaTPB) and various plasticizers viz. o-Nitrophenyloctyl ether (o-NPOE), dioctylpthalate (DOP), dibutylphthalate (DBP), tris(2-ethylhexyl)phosphate (TEHP), and benzyl acetate (BA) have found to improve the performance of the sensors. The best performance was obtained for the membrane sensor having a composition of L1:PVC:DBP:NaTPB in the ratio 5:150:250:3 (w/w). The sensor exhibits Nernstian response in the concentration range 8.9 × 10−8 to 1.0 × 10−1 M Cr3+ with limit of detection 5.6 × 10−8 M. The proposed sensor manifest advantages of relatively fast response (10 s) and good selectivity over some alkali, alkaline earth, transition and heavy metal ions. The selectivity behavior of the proposed electrode revealed a considerable improvement as compared to the best previously PVC-membrane electrode for chromium(III) ion. The potentiometric response of the proposed sensor was independent of pH of the test solution in the range of 2.0-7.0. The sensor has found to work satisfactorily in partially non-aqueous media up to 20% (v/v) content of methanol, ethanol and acetonitrile and could be used for a period of 3 months. The proposed electrode was used as an indicator electrode in potentiometric titration of chromium ion with EDTA and in direct determination in different water and food samples.  相似文献   

14.
A new polyvinyl chloride (PVC) membrane electrode that is highly selective to Hg(II) ions was prepared by using bis[5-((4-nitrophenyl)azo salicylaldehyde)] (BNAS) as a suitable neutral carrier. The sensor exhibits a Nernstian response for mercury ions over a wide concentration range (5.0×10−2-7.0×10−7 M) with a slope of 30±1 mV per decade. It has a response time of <10 s and can be used for at least 3 months without any measurable divergence in potential. The electrode can be used in the pH range from 1.0 to 3.5. The proposed sensor shows fairly good discriminating ability towards Hg2+ ion in comparison with some hard and soft metals. The electrode was used in the direct determination of Hg2+ in aqueous solution and as an indicator electrode in potentiometric titration of mercury ions.  相似文献   

15.
A highly selective poly(vinyl chloride) (PVC) membrane electrode based on 1,8-dibenzyl-1,3,6,8,10,13-hexaazacyclotetradecane-Ni(II) as a membrane carrier with unique selectivity toward thiocyanate is reported. The influence of membrane composition, pH and foreign anions were investigated. The sensor exhibits a Nernstian response for thiocyanate over a wide concentration range of 3.3×10−6 to 0.10 M, with a slope 58.4±0.3 mV per decade. The limit of detection is 3.0×10−6 M SCN. The sensor has a response time of <20 s and can be used for at least 2 months without any considerable divergence in potential. The proposed electrode shows fairly a good discriminating ability towards SCN ion in comparison to other anions. It was successfully applied to direct determination of thiocyanate in urine and saliva and it was also used as an indicator electrode in titration of thiocyanate with Ag+ ions.  相似文献   

16.
《Electroanalysis》2002,14(23):1621-1628
Copper phthalocyanine was used as ion carrier for preparing polymeric membrane selective sensor for detection of iodide. The electrode was prepared by incorporating the ionophore into plasticized poly(vinyl chloride) (PVC) membrane, coated on the surface of graphite electrode. This novel electrode shows high selectivity for iodide with respect to many common inorganic and organic anions. The effects of membrane composition, pH and the influence of lipophilic cationic and anionic additives and also nature of plasticizer on the response characteristics of the electrode were investigated. A calibration plot with near‐Nernestian slope for iodide was observed over a wide linear range of five decades of concentration (5×10?6?1×10?1 M). The electrode has a fast response time, and micro‐molar detection limit (ca. 1×10?6 M iodide) and could be used over a wide pH range of 3.0–8.0. Application of the electrode to the potentiometric titration of iodide ion with silver nitrate is reported. This sensor is used for determination of the minute amounts of iodide in lake water samples.  相似文献   

17.
Bis(2-hydroxyacetophenone)butane-2,3-dihydrazone (BHAB) was used as new N-N Schiffs base which plays the role of an excellent ion carrier in the construction of a Cu(II) membrane sensor. The best performance was obtained with a membrane composition of 30% poly(vinyl chloride), 55% o-nitrophenyloctyl ether (NPOE), 7% BHAB and 8% oleic acid (OA). This sensor shows very good selectivity and sensitivity towards copper ion over a wide variety of cations, including alkali, alkaline earth, transition and heavy metal ions. The effect of membrane composition and pH and influence of additive anionic on the response properties of electrode were investigated. The electrode exhibits a Nernstian behavior (with slope of 29.6 mV per decade) over a very wide concentration range (5.0 × 10−8 to 1.0 × 10−2 mol L−1) with a detection limit of 3.0 × 10−8 mol L−1 (2.56 ng mL−1). It shows relatively fast response time, in whole concentration range (<15 s), and can be used for at least 12 weeks in the pH range of 2.8-5.8. The proposed sensor was successfully used to determination of copper in different water samples and as indicator electrode in potentiometric titration of copper ion with EDTA.  相似文献   

18.
A novel poly(vinyl chloride) membrane electrode with high selectivity toward salicylate (Sal), based on the use of the salicylal-imino acid Schiff base dibenyl complex of Sn(IV) [Sn(IV)-SIADBen] as ionophore is described. The influence of lipophilic charged additives on the performance of the electrode was studied. The results suggested that Sn(IV)-SIADBen according to a positively-charged carrier mechanism. The influence of several other variables was investigated in order to optimize the potentiometric response and selectivity of the electrode. The electrode based on Sn(IV)-SIADBen, with 30.44 wt% PVC, 64.55 wt% plasticizer [dioctyl phthalate (DOP)], 3.81 wt% ionophore, and 1.2 wt% anionic additive exhibited a linear response for the Sal ion over the concentration range 1.0×10–1 to 2.5×10–6 mol l–1, and displayed an anti-Hofmeister selectivity sequence as follows: salicylate perchlorate > thiocyanate > benzoate > iodide > nitrate > chloride > nitrite acetate > citrate > sulfate. UV-Visible absorption spectra were used to examine the specific interaction of salicylate with the ionophore. The electrode was applied to clinical medical analysis, and the results obtained were consistent with those obtained by conventional methods.  相似文献   

19.
Singh AK  Saxena P  Mehtab S  Gupta B 《Talanta》2006,69(2):521-526
A new PVC membrane electrode based on 5,7,12,14-dibenzo-2,3,9,10-tetraoxa-1,4,8,11-tetraazacyclotetradecane (I) as an ion carrier, o-nitrophenyloctyl ether (o-NPOE) as solvent mediator and sodium tetraphenylborate (NaTPB) as lipophilic additive was fabricated and investigated as Sr2+-selective electrode. The best performance was exhibited by the membrane having composition 8:200:4:120 (I:o-NPOE:NaTPB:PVC). The electrode exhibited a Nernstian response for strontium ion over a wide concentration range 3.98 × 10−6 to 1.0 × 10−1 M with a slope of 29.0 ± 0.1 mV/decade of concentration and a detection limit of 2.82 × 10−6 M. It showed a response time of less than 10 s and could be used for at least 3 months without any divergence in potential. The proposed electrode showed a good discriminating ability towards strontium(II) ion over a wide variety of other metal ions including alkali, alkaline earth, transition, and heavy metal ions. The electrode can be used in the pH range of 2.5-10.5 and in mixtures containing up to 35% (v/v) non-aqueous content. It was used as an indicator electrode in potentiometric titration of strontium ion against EDTA.  相似文献   

20.
Mahajan RK  Kaur I  Lobana TS 《Talanta》2003,59(1):101-105
A new ion-selective PVC membrane electrode based on salicylaldehyde thiosemicarbazone as an ionophore is developed successfully as sensor for mercury(II) ions. The electrode shows excellent potentiometric response characteristics and displays a linear log[Hg2+] versus EMF response over a wide concentration range of 1.778×10−6-1.0×10−1 M with Nernstian slope of 29 mV per decade with the detection limit of 1.0×10−6 M. The response time of the electrode is less than 30 s and the membrane electrode operates well in the pH range of 1.0-3.0. The lifetime of the sensor is about 2 months. The electrode shows better selectivity towards Hg2+ ions in comparison with the alkali, alkaline and some heavy metal ions; most of these metal ions do not show significant interference (KPotHg,M values of the order of 10−3-10−4). The present sensor showed comparable or even better performance vis-à-vis similar PVC based ion-selective electrodes reported in literature. The sensor was also applied as an indicator electrode for potentiometric titration of Hg2+ions with I and Cr2O72−.  相似文献   