首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A novel capillary electrophoretic (CE) method, based on in-capillary complexation with [PW(11)O(39)](7-), was developed for the determination of cadmium(II) in natural water samples. When a sample solution is injected into a capillary containing 0.20 mM [PW(11)O(39)](7-) and 0.10 M malonate buffer (pH 3.0), the ternary Keggin-type complex, [P(Cd(II)W(11))O(39)](5-), which possesses high molar absorbtivities in the UV region, is formed in the capillary, and its migration toward the anode gives a well-defined migration peak in the electropherogram. An advantage of this method is that many divalent metal ions do not interfere. The proposed method was successfully applied to the determination of Cd(II) in environmental samples. The detection limits were 1 x 10(-7) and 5 x 10(-7) M for river-water and seawater samples, respectively (signal-to-noise ratio = 3).  相似文献   

2.
In this work, a capillary electrophoresis (CE) procedure was developed for the simultaneous determination of a pharmaceutical drug and its counter-ion, namely labetalol hydrochloride. For this purpose, an uncoated fused-silica capillary, a low conductivity background electrolyte (BGE) and a capacitively coupled contactless conductivity detector (C4D) were employed. This detection system is highly sensitive and enables detection of inorganic as well as organic ions unlike with direct UV detection. Moreover, to be able to simultaneously analyze the cationic drug (labetalol+) and its anionic counter-ion (Cl) in the same electrophoretic run without the need of a coated capillary, a dual-opposite end injection was performed. In this technique, the sample is hydrodynamically injected into both ends of the capillary. This method is simple and easy to perform since the different injection steps are automated by the CE software.This novel CE-C4D procedure with dual-opposite end injection has been successfully validated and applied for the analysis of chloride content in an adrenergic antagonist (labetalol hydrochloride). Thus, the hereby developed method has been shown to enable fast (analysis time < 10 min), precise (repeatability of migration times < 0.7% and of corrected-peak areas < 3.3%; n = 6) and rugged analyses for the simultaneous determination of a pharmaceutical drug and its counter-ion.  相似文献   

3.
This paper examines the potentiality of in-capillary derivatization for improving the sensitivity of the spectrophotometric detection of amino acids in capillary zone electrophoresis. 1,2-Naphthoquinone-4-sulfonate was selected as the labeling agent of amino acids. The underivatized sample and the reagent solution segments are injected by pressure into the capillary prior to applying the running voltage. The corresponding derivatization reaction occurs inside the capillary once the potential is applied, as it induces mixing of the sample with the reagent. Several introduction modes consisting of tandem or sandwich configuration have been evaluated. These techniques result in a straightforward and automated way of carrying out a derivatization. Furthermore, in-capillary procedures may become much more attractive than conventional pre-capillary derivatization in terms of sensitivity and reproducibility. The optimum operation mode found consists of a sandwich system where the sample is injected in between two reagent segments. The method was applied to the determination of amino acids in feed samples. Results show a good concordance with those given by a standard amino acid analyzer.  相似文献   

4.
Chen H  Yu Y  Xia Z  Tang S  Mu X  Long S 《Electrophoresis》2006,27(21):4182-4187
A novel method of inline coupling of microdialysis (MD) with CE has been investigated. A polysulfone MD membrane was in situ prepared at the inlet end of the separation capillary, which endued the capillary with an additional function of clean-up sampling and made the pretreatment of complex matrices simple. The properties of the membrane and its influence on electrophoresis were evaluated. The membrane cut off macromolecules and particles efficiently and persistently, and changing the components of membrane-casting solution could control the molecular weight cutoff of the membrane. Using the capillary having the MD membrane in electrophoresis, column efficiency with little reduction was achieved. The mixture of chlorpheniramine (CPA) and BSA was used to verify the analytical characteristics. Only the peak of CPA appears in the electropherograms and the RSDs of migration times and peak areas of CPA were 0.8 and 4.6%, respectively. The method was applied for the determination of glucose in human blood using an electrochemical detector. Whole blood containing glucose and macromolecules was electrokinetically injected directly into the capillary without pretreatment, and the concentration of glucose in human blood was 5.5 mmol/L. Equilibrium dialysis injection is also investigated in this paper. The results show that the method may be further used for in vivo sampling to monitor the endogenous or exogenous small molecules and their metabolites.  相似文献   

5.
本文首次报道了人血清免疫反应后直接进样并利用毛细管电泳分离化学发光灵敏检测AFP的新方法, 检测结果与医院使用的全自动微粒子化学发光仪检测结果吻合.  相似文献   

6.
Yamamoto D  Kaneta T  Imasaka T 《Electrophoresis》2007,28(22):4143-4149
This study investigated a novel postcolumn reactor for fluorescence detection in CE. A laser-drilled capillary, with an aperture made by laser ablation, was used for mixing derivatization reagents with the analytes separated by CZE. The derivatization reagents, o-phthaldialdehyde (OPA), and 2-mercaptoethanol, were introduced into the capillary through the aperture and reacted with the analytes after CZE separation. High voltages were applied to both the inlet reservoir and the reservoir filled with the derivatization reagents. Thus, the flow rate of the derivatization reagents was controlled by the electric potential that was applied to the reservoir of the derivatization reagents. A UV light-emitting diode was used as an excitation light source for the fluorescence detection of OPA derivatives. A commercially available tee connector was compared with the laser-drilled capillary. The results implied that the dead volume of the laser-drilled capillary was less than that of the tee connector, since the laser-drilled capillary suppressed band broadening more efficiently. The LODs for amino acids were determined to be approximately 5 microM. The method was applied to the determination of amino acids in a Japanese beverage.  相似文献   

7.
A novel assay was developed for the simultaneous monitoring of quantum dots and their assembly and disassembly with PreScission protease using capillary electrophoresis with fluorescence detection. Quantum dots and PreScission protease were injected into a capillary sequentially, then mixed and assembled via a thioether bond upon coupling to glutathione S‐transferase tag inside the capillary. The in‐capillary assembly was influenced by the molar ratio and the time interval of injection. Furthermore, the simultaneous monitoring of quantum dots and their assembly with PreScission protease and glutathione induced disassembly was achieved by adjusting the sampling sequence and the time interval of injection. More importantly, the in‐capillary assay could be also applied to the online detection of glutathione.  相似文献   

8.
We introduce a novel electrophoretic method, nonequilibrium capillary electrophoresis of equilibrium mixtures (NECEEM), and demonstrate its use for studying protein-DNA interactions. The equilibrium mixture of protein and DNA contains three components: free protein, free DNA, and the protein-DNA complex. A short plug of such a mixture is injected into the capillary, and the three components are separated under nonequilibrium conditions. The resulting electropherograms are composed of characteristic peaks and exponential curves. An easy nonnumerical analysis of a single electropherogram reveals two parameters: the equilibrium binding constant and the monomolecular rate constant of complex decay. The bimolecular rate constant of complex formation can then be calculated as the product of the two experimentally determined constants. NECEEM was applied to study the interaction between single-stranded DNA binding protein and a fluorescently labeled 15-mer oligonucleotide. It allowed us to measure for the first time the rate constant of complex decay for this important protein-DNA pair, k-1 = 0.03 s-1. The value of the equilibrium binding constant, Kb = 3.6 x 10-6 M-1, was in good agreement with those measured by other methods. As low as 10-18 mol of the protein was sufficient for the measurements. Thus, the new method is simple, informative, and highly sensitive. Moreover, it can be equally applied to other noncovalent protein-ligand complexes. These features of NECEEM make this method an indispensable tool in studies of macromolecular interactions. They also emphasize the potential role of NECEEM in the development of extremely sensitive protein assays using nucleotide aptamers.  相似文献   

9.
The performance of an integrated capillary electrophoresis system with a novel split-flow sample injection mechanism and special high sensitivity UV absorbance detector is described. Sample introduction into the capillary is accomplished with a standard HPLC-type microliter syringe. The injected sample is divided proportionally between the separation capillary and an adjustable splitvent. The volume of sample introduced into the capillary can be manipulated by varying the length or the i.d. of the splitvent tubing; or the volume of sample injected. Data are presented showing reproducibility of retention time, peak height, and peak area; minimum detectability; and operation at short UV wavelengths.  相似文献   

10.
A multiple-injection capillary zone electrophoresis (MICZE) method has been developed for the assay of salbutamol in Ventoline Depot tablets (GlaxoSmithKline). In the developed method, seven sample sets, each consisting of three samples, were sequentially injected into the capillary and analyzed within a single run. This enabled a total of twenty-one sequential injections, i.e., six standards and fifteen samples, containing salbutamol and the injection marker oxprenolol. The injected sample plugs were separated by plugs of background electrolyte, through application of a short-term voltage (30kV) over the capillary for different time periods, i.e., t(PE1) and t(PE2). The samples in each set were isolated from each other by partial electrophoresis for 2.35min (t(PE1)), while the sample sets were separated for 10.50min (t(PE2)). After the final injection, all the applied samples were subjected to electrophoresis for a time period corresponding to that in conventional single-injection CZE. The method was validated regarding linearity, accuracy, precision and robustness before it was applied to the determination of salbutamol in 15 tablets of Ventoline Depot with a labeled content of 8mg salbutamol. The average salbutamol content was determined to 7.8mg (+/-0.3mg) from simultaneous analyses of the 15 different tablets.  相似文献   

11.
Ramachandran KM  Kumar GS 《Talanta》1996,43(8):1269-1273
A new selective open tubular capillary gas chromatographic method is developed for the determination of trace amounts of piperazine. Piperazine is extracted from pharmaceuticals into cyclohexane and is partitioned with water. The aqueous solution is then injected into a 5% crosslinked Ph-Me silicone column programmed at 50-180 degrees C for 10 min. Piperazine is eluted after 3.18 min under isothermal conditions. The lower limit of determination is 0.4 ppm. This method has been successfully applied for the assay of piperazine in pharmaceutical formulations and its trace determination in fluoroquinolone drugs such as norfloxacin and ciprofloxacin. The method is reproducible and the standard and relative standard deviation for 10 repeated injections of 2 mug piperazine are 0.7 and +/-2.1% respectively.  相似文献   

12.
A capillary electrophoresis apparatus was used as sampler for flow injection analysis (FIA) in tandem mass spectrometry of L-carnitine and its acetyl- and propionyl-metabolites in human plasma. The capillary electrophoresis instrument was coupled to the ion trap mass spectrometer by an electrospray ionization coaxial sheath liquid interface. The electrophoresis capillary introduced the sample directly into the source by applying a prolonged sample injection. The use of the capillary electrophoresis apparatus miniaturised the FIA procedure, substantially reducing the quantities of solvents and samples used, and allowed rapid automated sequential analyses. The method was optimised and validated using a dialyzed human plasma matrix. The plasma samples were analysed after a simple, rapid deproteinisation procedure with acetonitrile and diluted 70 times before direct injection into the mass spectrometer for product ion scan MS/MS analysis in positive ionisation. The total analysis time was 5 min, including capillary preconditioning and acquisition time (3 min). The method was sensitive, allowing the determination of L-, L-acetyl- and L-propionyl-carnitines at 140, 14 and 3.6 nM concentrations (injected values) corresponding to lower limit of quantitation values in plasma of 10, 1 and 0.25 microM, respectively. The method was processed for full validation and applied to the analysis of L-carnitine and its short chain derivatives in human plasma samples.  相似文献   

13.
A hollow fiber sampling inlet end of capillary electrophoresis (CE) for small ions in complex samples is described. A short piece of hollow fiber, which only permits small ions to pass through its wall, was directly connected to one end of a capillary. Small ions in complex samples were injected into the capillary through the hollow fiber by an electrokinetic method. The experimental results of CE for standard anion mixture solutions, river water, and milk samples show that the hollow fiber sampling inlet end is a simple and useful method for the CE of complex samples. Furthermore, it has been shown that the method can be used to study small anion changes during the milk storing process.  相似文献   

14.
邵景玲 《分析测试学报》2016,35(11):1491-1495
采用准静态扫集胶束电动毛细管色谱(MEKC)法测定了扇贝样品中的2种贝类毒素。毛细管内首先充满含十二烷基硫酸钠(SDS)的缓冲溶液,调节缓冲溶液的pH值,使电渗流等于SDS胶束的电泳流速,电动进样时,带正电荷的贝类毒素离子被SDS扫集吸附,由于SDS在毛细管内处于准静止状态,可使进样时间延长至320 s。与常规电动进样MEKC相比,石房蛤毒素和软骨藻酸的检测灵敏度分别提高950和810倍。该方法对石房蛤毒素和软骨藻酸的检出限分别为0.05,0.12 ng/m L。方法可实现对扇贝样品中2种贝类毒素的快速、灵敏检测。  相似文献   

15.
As a vast number of novel materials in particular inorganic nanoparticles have been invented and introduced to all aspects of life, public concerns about how they might affect our ecosystem and human life continue to arise. Such incertitude roots at a fundamental question of how inorganic nanoparticles self‐assemble with biomolecules in solution. Various techniques have been developed to probe the interaction between particles and biomolecules, but very few if any can provide advantages of both rapid and convenient. Herein, we report a systematic investigation on quantum dots (QDs) and protein self‐assembly inside a capillary. QDs and protein were injected to a capillary one after another. They were mixed inside the capillary when a high voltage was applied. Online separation and detection were then achieved. This new method can also be used to study the self‐assembly kinetics of QDs and protein using the Hill equation, the KD value for the self‐assembly of QDs and protein was calculated to be 8.8 μM. The obtained results were compared with the previous out of‐capillary method and confirmed the effectiveness of the present method.  相似文献   

16.
This is the first capillary electrophoresis (CE) analysis for diagnosis of hemophilia A (HA). The intron 22 inversion of factor VIII gene (F8) causes 40–50 % of severe bleeding disorder of HA in all human populations. Consequently, identification of the disease-causing mutations is becoming increasingly important for accurate genetic counseling and prenatal diagnosis. In this study, the key steps of inverse-shifting polymerase chain reaction (IS-PCR) and of short-end injection capillary electrophoresis were used for more specific and rapid genotyping of intron 22 inversion of F8. In IS-PCR, three specific primers were used to amplify 512-bp amplicon for wild type and 584-bp amplicon for patients with intron 22 inversion. The capillary gel electrophoresis (CGE) system was performed using 1× Tris–borate–EDTA (TBE) buffer containing 0.3 % (w/v) polyethylene oxide (PEO). The PCR amplicons were electrokinetically injected at 10 kV for 10 s at a temperature of 25 °C. The optimal short-end injection CGE was applied to detect the F8 gene of HA patients and carriers within 5 min. Intron 22 inversion was indeed found on some HA patients (13/35, 37.1 %). All genotyping results showed good agreement with DNA sequencing method and long-distance polymerase chain reaction (LD-PCR). The IS-PCR combined with short-end injection CGE method was feasible and efficient for intron 22 inversion screening of F8 in the HA populations.  相似文献   

17.
A Hadamard transform-capillary electrophoresis-UV (HT-CE-UV) detection technique is described for the analysis of biological samples. Pseudorandom injections of sample and buffer according to a simplex matrix obtained from the corresponding Hadamard matrix is performed with conventional capillaries. Alternating injections are achieved with a novel capillary "T" connector created by drilling conventional capillary dimensions through a 1-cm diameter polycarbonate disc. This connector design coupled with a switching system allows for rapid, electrokinetic injections of solution into alternating sample and buffer capillary arms for UV detection. The standard mixtures of nitric oxide (NO) metabolites, nitrite and nitrate, dissolved in physiological saline solution are injected into the separation capillary according to an 83-element injection sequence to obtain a signal-to-noise ratio (S/N) enhancement of ca. 4.5 over a single injection. Nitrite, being the less concentrated metabolite in NO detection and thereby more difficult to detect, was calibrated with the HT-CE-UV method and a limit of detection (LOD) of 0.56 microM was obtained. Rat blood plasma was analyzed with this detection system and demonstrated to be comparable with NO metabolite concentrations of previously published results. This HT-CE-UV method is described where a unique reservoir tube design that contains 8-microL standard nitrite sample volumes is placed over the end of the capillary arm to explore low volume limits for biological samples.  相似文献   

18.
A quantitative sample introduction method based upon inkjet injection was applied to capillary electrophoresis coupled with stacking and sweeping on‐line concentration techniques. Methylxanthines were used as model compounds for the proof‐of‐concept of the method. The volume of injected sample could be easily manipulated by controlling the number of ejected droplets in the injection procedure. Under optimized conditions, a linear relationship between the ejected droplet number and peak area was obtained when the droplet number introduced into the capillary was less than 100. Under optimized quantitative on‐line concentration conditions, the limits of detection for theobromine, caffeine, and theophylline were 1.0, 2.0, and 1.0 μM, respectively. The inkjet injection system was evaluated by comparing it with conventional injection methods. The electropherogram of the inkjet injection mode was the same as that for hydrodynamic injection mode, and no sample discrimination was observed compared with the electrokinetic injection mode. The established method was applied to the determination of methylxanthines in bottled green tea. The recoveries of theobromine, caffeine, and theophylline were 94.1, 110.6, and 86.8%, respectively. We conclude that proposed method can be used for quantitative concentration for capillary electrophoresis, thus resulting in an improved accuracy.  相似文献   

19.
A novel method for the on-column sample stacking of proteins is described. The strategy takes advantage of interactions between protein molecules and sodium dodecyl sulfate (SDS) monomers. A long plug of a protein sample (either acidic or basic) is injected into a capillary filled with a background electrolyte (BGE) containing SDS. When a potential is applied, the proteins interact with SDS monomers in the BGE to form protein-SDS complexes that migrate more slowly than the corresponding uncomplexed protein, resulting in protein stacking. Both acidic and basic proteins migrate at an almost identical electrophoretic velocity after stacking, which indicates that the protein-SDS complexes formed in the BGE zone have a similar charge/mass ratio. The mechanism of stacking was investigated using a sample consisting of a basic protein, lysozyme, and a small molecule, methylene blue. The findings clearly show that two interactions with SDS occur, a stepwise binding interaction between protein molecules and SDS monomers and an interaction in which the small molecules enter into micelles formed by SDS molecules. The method was also applied to the detection of a protein labeled with a fluorescent labeling reagent at trace levels. The labeled protein was detected even under labeling conditions where the labeling efficiency was too low to detect by short-plug injection.  相似文献   

20.
金银花的毛细管电泳指纹图谱研究   总被引:23,自引:0,他引:23  
孙国祥  杨宏涛  邓湘昱  孙毓庆 《色谱》2007,25(1):96-100
采用毛细管区带电泳法,以50 mmol/L硼砂(含20 mmol/L β-环糊精(CD),用磷酸调pH 8.0)为背景电解质,运行电压12 kV,紫外检测波长254 nm,重力进样15 s(高度8.5 cm),建立了金银花药材水提取液的毛细管电泳指纹图谱(CEFP)。将13个不同产地的金银花药材供试液的CEFP进行比较,以电泳峰出现率100%计,确定金银花的共有指纹峰为18个。该CEFP具有较好的精密度和重现性,分离效能高且成本低廉。提出了指纹图谱宏观含量相似度R、投影含量相似度C和定量相似度P的概念,可从总体上评价药材化学组分的整体含量情况。从两个方面评价各产地药材与对照CEFP间的总体相似性,合格药材应具备以下两个条件:(1)代表化学成分分布相似性的定性相似度(S)≥0.90;(2)描述药材整体化学成分含量的定量相似度(R,C,P,Q)应在80%~120%。以此二类相似度指标控制金银花的质量,建立了指纹图谱评价的又一新方法。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号