首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 504 毫秒
1.
Test methods have to be developed by laboratories for official control to monitor possible misuse of veterinary drugs in animal productions, also through feeding stuff. A novel method for identification and quantification of levamisole in feeds by liquid chromatography coupled to electrospray mass spectrometry in an ion trap (LC/ESI‐MS/MS) is herein described; after a single‐step cleanup by liquid‐liquid extraction from the feed and separation by reversed‐phase liquid chromatography, levamisole was determined and unambiguously confirmed by tandem mass spectrometry, on the basis of two product ions. The method was in‐house validated, according to the Regulation 882/2004/EC, evaluating trueness, repeatability, within‐laboratory reproducibility, ruggedness, specificity, and the limit of quantification (LOQ). The method is reliable and specific for complete and complementary feeds for pigs, cattle, rabbits and poultry; very good mean recoveries (higher than 92 %) and precision (RSD values < 15.2%) were attained. The LOQ at 2.0 mg/kg was verified. Moreover, we describe how the method was developed to support Italian Police investigations regarding illegal treatments of pigs; in this case, since the drug(s) added to the feed were unknown, a preliminary untargeted analysis was performed by full scan mass spectrometry on an ion trap, from 50 up to 2000 m/z; the presence of levamisole was hypothesised, on the basis of the most abundant ion and its fragmentation pattern. Then, levamisole was unambiguously confirmed by the ion trap LC/ESI‐MS/MS method. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

2.
A new analytical method based on liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI‐MS/MS) is proposed and validated for the identification and quantification of alkyl alkylphosphonic acids (AAPAs) in aqueous matrices. Retrospective detection and identification of degradation products of chemical warfare agents is important as an indicator of possible use of chemical warfare agents or of environmental contamination. A commercially available solution of 1,9‐nonanediyl‐bis‐(3‐methylimidazolium)bisfluoride (NBMI) allowed detection of AAPAs by positive mode electrospray ionization mass spectrometry by forming an adduct with AAPAs. MS/MS experiments using an ion trap analyzer were carried out for unambiguous identification of AAPAs. Different parameters were optimized in order to obtain both an adequate chromatographic separation and a high sensitivity using experimental design methodology. Quantification was done with matrix‐matched calibration standards of AAPAs. The method was validated in terms of linearity (r2 >0.982), intra‐ and inter‐day precisions (RSD below 15%), and robustness. The method is sensitive enough for the determination of AAPAs in aqueous matrices, with limits of detection in the 1–5 ng mL–1 range and limits of quantification in the 5–20 ng mL–1 range. Finally, the method was successfully applied to determine these AAPAs in aqueous samples provided by the Organization for the Prohibition of Chemical Weapons during 26th and 29th official proficiency tests. The added advantage of this method is identification of low mass range analyte at high mass range, which obviates the background noise at low mass range. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

3.
Cyanobacteria, also called blue‐green algae, occur worldwide within water blooms in eutrophic lakes and drinking water reservoirs, producing several biotoxins (cyanotoxins). Among these, microcystins (MCs) are a group of cyclic heptapeptides showing potent hepatotoxicity and activity as tumour promoters. So far, at least 89 MCs from different cyanobacteria genera have been characterised. Herein, ion trap, matrix‐assisted laser desorption/ionisation time‐of‐flight (MALDI‐ToF) and quadruple time‐of‐flight (Q‐ToF) mass spectrometry (MS)‐based methods were tested and compared for analysing MCs in freshwaters. Method performances in terms of limit of detection, limit of quantification, mean recoveries, repeatability, and specificity were evaluated. In particular, a liquid chromatography/electrospray ionisation (LC/ESI)‐Q‐ToF‐MS/MS method was firstly described to analyse MCs in freshwaters; this technique is highly selective and sensitive, and allowed us to characterise the molecular structure of an unknown compound. Indeed, the full structural characterisation of a novel microcystin variant from a bloom of Planktothrix rubescens in the Lake Averno, near Naples, was attained by the study of the fragmentation pattern. The new cyanotoxin was identified as the 9‐acetyl‐Adda variant of microcystin‐RR. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

4.
A rapid and sensitive method for the identification and quantification of 10‐hydroxycamptothecine (HCPT) in Camptotheca acuminata Decne is described. The HCPT standard solution was directly infused into the ion trap mass spectrometers (IT/MS) for collecting the MSn spectra. The electrospray ionization (ESI) mass spectral fragmentation pathway of HCPT was proposed and the ESI‐MSn fragmentation behavior of HCPT was deduced in detail. The major fragment ions of HCPT were confirmed by MSn in both negative ion and positive ion mode. The possible main cleavage pathway of fragment ions was studied. Quantification of HCPT was assigned in negative‐ion mode at a product ion at m/z 363 → 319 by LC‐MS. The LC‐MS method was validated for linearity, sensitivity, accuracy and precision, and then used to determine the content of the HCPT. Lastly, the LC‐MS method was successfully applied to determine HCPT in real samples of Camptotheca acuminate Decne and its medicinal preparation in the first time. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

5.
A liquid chromatographic–electrospray ionization–time‐of‐flight/mass spectrometric (LC‐ESI‐TOF/MS) method was developed and applied for the determination of WKYMVm peptide in rat plasma to support preclinical pharmacokinetics studies. The method consisted of micro‐elution solid‐phase extraction (SPE) for sample preparation and LC‐ESI‐TOF/MS in the positive ion mode for analysis. Phenanthroline (10 mg/mL) was added to rat blood immediately for plasma preparation followed by addition of trace amount of 2 m hydrogen chloride to plasma before SPE for stability of WKYMVm peptide. Then sample preparation using micro‐elution SPE was performed with verapamil as an internal standard. A quadratic regression (weighted 1/concentration2), with the equation y = ax2 + bx + c was used to fit calibration curves over the concentration range of 3.02–2200 ng/mL for WKYMVm peptide. The quantification run met the acceptance criteria of ±25% accuracy and precision values. For quality control samples at 15, 165 and 1820 ng/mL from the quantification experiment, the within‐run and the between‐run accuracy ranged from 92.5 to 123.4% with precision values ≤15.1% for WKYMVm peptide from the nominal values. This novel LC‐ESI‐TOF/MS method was successfully applied to evaluate the pharmacokinetics of WKYMVm peptide in rat plasma.  相似文献   

6.
Flavomycin complex is an antibiotic banned in the European Union as an additive in feed stuffs. As a consequence, the monitoring programmes for official control within the Community require analysis of feeds for possible illegal use of flavomycin. A method for unambiguous identification and quantification of moenomycin A, the main pharmacologically active component of flamomycin complex, in several feeds by liquid chromatography coupled to electrospray ion trap mass spectrometry (LC/ESI‐MS/MS) is herein described for the first time. The method was developed to be used as a confirmative analytical tool for the network of Italian official control laboratories; both the singly and doubly charged molecular ions were observed as precursor ions, from which four product ions were selected for both quantitative analysis and unambiguous identification of moenomycin A. The method was in‐house validated for feeds in the concentration range 0.50–30.0 µg/g, according to the Regulation 882/2004/EC requirements. Mean recoveries ranging between 83.9–94.2% and relative standard deviations <23% account for method trueness and repeatability, respectively. Moreover, other analytical performance parameters, i.e. method specificity, ruggedness, the linearity of detector response, the limit of quantification (LOQ), the limit of detection (LOD), and measurement uncertainty were evaluated and reported. The ion trap LC/ESI‐MS/MS method is highly selective and reliable; high drug recovery, good reproducibility and an LOQ down to 0.10 µg/g guarantee its applicability for confirmatory purposes in the official control activity in Italy. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

7.
Recent advances in liquid chromatography/tandem mass spectrometry (LC/MS/MS) technology have provided an opportunity for the development of more specific approaches to achieve the ‘screen’ and ‘confirmation’ goals in a single analytical step. For this purpose, this study adapts the electrospray ionization ion trap LC/MS/MS instrumentation (LC/ESI‐MS/MS) for the screening and confirmation of over 800 drugs and toxic compounds in biological specimens. Liquid‐liquid and solid‐phase extraction protocols were coupled to LC/ESI‐MS/MS using a 1.8‐µm particle size analytical column operated at 50°C. Gradient elution of the analytes was conducted using a solvent system composed of methanol and water containing 0.1% formic acid. Positive‐ion ESI‐MS/MS spectra and retention times for each of the 800 drugs and toxic compounds were first established using 1–10 µg/mL standard solutions. This spectra and retention time information was then transferred to the library and searched by the identification algorithm for the confirmation of compounds found in test specimens – based on retention time matches and scores of fit, reverse fit, and purity resulting from the searching process. The established method was found highly effective when applied to the analyses of postmortem specimens (blood, urine, and hair) and external proficiency test samples provided by the College of American Pathology (CAP). The development of this approach has significantly improved the efficiency of our routine laboratory operation that was based on a two‐step (immunoassay and GC/MS) approach in the past. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

8.
A simple and sensitive liquid chromatography–electrospray ionization–tandem mass spectrometry (LC‐ESI‐MS/MS) technique was developed and validated for the determination of sibutramine and its N‐desmethyl metabolites (M1 and M2) in human plasma. After extraction with methyl t‐butyl ether, chromatographic separation of analytes in human plasma was performed using a reverse‐phase Luna C18 column with a mobile phase of acetonitrile–10 mm ammonium formate buffer (50:50, v/v) and quantified by ESI‐MS/MS detection in positive ion mode. The flow rate of the mobile phase was 200 μL/min and the retention times of sibutramine, M1, M2 and internal standard (chlorpheniramine) were 1.5, 1.4, 1.3 and 0.9 min, respectively. The calibration curves were linear over the range 0.05–20 ng/mL, for sibutramine, M1 and M2. The lower limit of quantification was 0.05 ng/mL using 500 μL of human plasma. The mean accuracy and the precision in the intra‐ and inter‐day validation for sibutramine, M1 and M2 were acceptable. This LC‐MS/MS method showed improved sensitivity and a short run time for the quantification of sibutramine and its two active metabolites in plasma. The validated method was successfully applied to a pharmacokinetic study in human. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

9.
A sensitive and specific method based on liquid chromatography‐tandem mass spectrometry using electrospray ionization (LC‐ESI‐MS/MS) has been developed for the determination of Schisandrin and Schisandrin B in rat plasma. A 100 μL plasma sample was extracted by methyl tert‐butyl ether after spiking the samples with nimodipine (internal standard) and performed on an XTerra®MS‐C18 column (150 mm × 2.1 mm, 3.5 μm) with the mobile phase of acetonitrile–water–formic acid (80:20:0.2, v/v) at a flow rate of 0.2 mL/min in a run time of 8.5 min. The lower limit of quantification of the method was 40 ng/mL for Schisandrin and 20 ng/mL for Schisandrin B. The method showed reproducibility with intra‐day and inter‐day precision of less than 13.8% RSD, as well as accuracy, with inter‐ and intra‐assay accuracies between 93.5 and 107.2%. Finally, the LC‐ESI‐MS/MS method was successfully applied to study the pharmacokinetics of Schisandrin and Schisandrin B in rats after administration of Wurenchun commercial formulations to rats. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

10.
A solid‐phase extraction and liquid chromatography‐tandem mass spectrometry (SPE/LC‐MS‐MS) method was developed and validated for the simultaneous determination of nicotine, five drugs of abuse (morphine, cocaine, codeine, methadone, and 2‐ethylidene‐1,5‐dimethyl‐3,3‐diphenylpyrrolidine) and four metabolites (dihydrocodeine, 6‐acetylmorphine, 11‐nor‐carboxy‐Δ9‐tetrahydrocannabinol, and benzoylecgonine) in water samples. A Fused‐Core? particle column was used as an alternative to sub‐2‐μm particles in chromatographic separations to work with low backpressures and high efficiencies in short analysis times. Drugs were extracted from waste and surface water with SPE using Oasis MCX cartridges. Electrospray (ESI) in positive and negative mode and tandem MS selected reaction monitoring mode were used for identification and quantification. Calibration by linear regression analysis with deuterated internal standards was used to compensate the matrix effects. Limits of detection were found as low as 0.5–1 ng/L (surface water) and 1–50 ng/L (wastewater). The method was applied to the analysis of different kinds of samples. Wastewater from a sewage treatment plant was collected from three sampling points (after primary, secondary, and tertiary treatments) for a week. The analysis of the samples revealed a significant presence of these drugs in samples from primary treatments, where maximum concentrations of nicotine (1105 ng/L) and benzoylecgonine (3336 ng/L) were found. Most of the compounds showed values between 相似文献   

11.
The occurrence of human and veterinary pharmaceutical compounds in surface waters (e.g. streams, lakes and reservoirs) is an important emerging environmental issue. There is a need for robust, sensitive and reliable analytical methods for measuring these compounds in a variety of natural water and wastewater matrices. This paper describes a method for the determination of seven tetracycline (TC) and six sulfonamide (SA) compounds in pristine and wastewater-influenced surface water using solid-phase extraction, and LCQ Duo ion trap liquid chromatography/tandem mass spectrometry (LC/MS/MS) with positive electrospray ionization (ESI(+)) and selected reaction monitoring (SRM). The seven TCs and six SAs analyzed using this method include oxytetracycline (OTC), chlortetracycline (CTC), tetracycline (TC), democlocycline (DMC), doxycycline (DXC), meclocycline (MCC), minocycline (MNC), sulfathiazole (STZ), sulfamerazine (SMR), sulfamethazine (SMT), sulfachloropyridazine (SCP), sulfamethoxazole (SMX), and sulfadimethoxane (SDM). This study discusses the effects of flow rate, LC column diameter and LC column temperature on UV and/or mass peak quality of the different analytes. Several product ions for MS/MS detection have been identified and compared for ion trap and triple quadrupole LC/MS/MS instruments. Statistical analysis for determination of the method detection limit (MDL), accuracy and precision of the method is described. Matrix effects are evaluated in deionized, pristine and wastewater-influenced river water. The method is applied to evaluate the occurrence of these compounds in a small watershed in northern Colorado.  相似文献   

12.
Capillary liquid chromatography (LC) using a 320 microns column and a flow rate of 10 microL/min has been coupled to an ion trap mass spectrometer using electrospray ionisation (ESI) to enable the rapid and effective identification of metabolites in urine, following oral administration of a novel human neutrophil elastase inhibitor, GW311616. Metabolites were identified from their mass (MS) spectra and tandem (MS/MS) mass spectra using minimal sample (1 microL of urine) and no sample pretreatment. Sensitivity assessment has shown that both molecular weight and structural information is obtainable on as little as 5 pg of compound, making the capillary LC/ion trap system as described an ideal analytical tool for the detection and characterisation of low level metabolites in biofluids (particularly when sample volume is limited). This level of detection was unattainable using a triple quadrupole mass spectrometer operating in full-scan mode, although 200 fg on column was detected using selected reaction monitoring target analysis.  相似文献   

13.
Rapid, simple and reliable HPLC/UV and LC‐ESI‐MS/MS methods for the simultaneous determination of five active coumarins of Angelicae dahuricae Radix, byakangelicol (1), oxypeucedanin (2), imperatorin (3), phellopterin (4) and isoimperatorin (5) were developed and validated. The separation condition for HPLC/UV was optimized using a Develosil RPAQUEOUS C30 column using 70% acetonitrile in water as the mobile phase. This HPLC/UV method was successful for providing the baseline separation of the five coumarins with no interfering peaks detected in the 70% ethanol extract of Angelicae dahuricae Radix. The specific determination of the five coumarins was also accomplished by a triple quadrupole tandem mass spectrometer equipped with an electrospray ionization source (LC‐ESI‐MS/MS). Multiple reaction monitoring (MRM) in the positive mode was used to enhance the selectivity of detection. The LC‐ESI‐MS/MS methods were successfully applied for the determination of the five major coumarins in Angelicae dahuricae Radix. These HPLC/UV and LC‐ESI‐MS/MS methods were validated in terms of recovery, linearity, accuracy and precision (intra‐ and inter‐day validation). Taken together, the shorter analysis time involved makes these HPLC/UV and LC‐ESI‐MS/MS methods valuable for the commercial quality control of Angelicae dahuricae Radix extracts and its pharmaceutical preparations. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

14.
A new analytical technique for the structural elucidation of four representative phenidate analogues possessing a secondary amine residue, which leads to a major/single amine‐representative fragment/product ion at m/z 84 both in their GC‐EI‐MS and LC‐ESI‐MS/MS spectra, making their identification ambiguous, was developed. The method is based on “in vial” chemical derivatization with isobutyl chloroformate in both aqueous and organic solutions, followed by liquid chromatography‐electrospray ionization mass spectrometry (LC‐ESI‐MS/MS). The resulting carbamate derivatives promote rich fragmentation patterns with full coverage of all substructures of the molecule, enabling detailed structural elucidation and unambiguous identification of the original compounds at low ng/mL levels.  相似文献   

15.
Using bamboo‐activated charcoal as SPE adsorbent, a novel SPE method was developed for the sensitive determination of tetrabromobisphenol A and bisphenol A in environmental water samples by rapid‐resolution LC‐ESI‐MS/MS. Important parameters influencing extraction efficiency, including type of eluent, eluent volume, sample pH, volume and flow rate, were investigated and optimized. Under the optimal extraction conditions (eluent: 8 mL methanol, pH: 7; flow rate: 4 mL/min; sample volume: 100 mL), low LODs (0.01–0.02 ng/mL), good repeatability (6.2–8.3%) and wide linearity range (0.10–10 ng/mL) were obtained. Satisfied results were achieved when the proposed method was applied to determine the two target compounds in real‐world environmental water samples with spiked recoveries over the range of 80.5–119.8%. All these facts indicate that trace determination of tetrabromobisphenol A and bisphenol A in real‐world environmental water samples can be realized by bamboo‐activated charcoal SPE‐rapid resolution‐LC‐ESI‐MS/MS.  相似文献   

16.
Ecdysteroids, which are steroid hormones in invertebrates, but which are also present in plants, could potentially be used as anabolic agents in food‐producing animals. The control of ecdysteroid misuse in cattle relies on the development of an efficient method for their detection in biological matrices at trace levels (µg L−1). In order to propose an analytical procedure dedicated to the identification of excreted 20‐hydroxyecdysone (20E) in urine and faecal samples of breeding animals, a comparative study of the spectrometric behaviour of these compounds was carried out both by LC/(ESI‐)/HRMSn (hybrid linear ion trap – orbital trap) and by LC/(ESI+)/MS/MS (triple quadrupole). This study revealed the formation of a large number of product ions both in positive and negative ion mode, corresponding to losses of water molecules and specific cleavages on the side chain. The sample preparation consisted of sequential purification on two solid‐phase extraction cartridges (SPE octadecylsilyl and SPE silica). The detection limits were around 0.5 µg L−1 in the selected reaction monitoring (SRM) mode and recoveries above 60% were obtained. The method was successfully applied to the analysis of real samples collected from calves treated with 60 mg 20E over 4 days. Analysis of the samples allowed the investigation of the kinetics of elimination of 20E in calf urine and determination of the time‐frame for the control of potential abuse. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

17.
The use of growth hormones, such as native and recombinant somatotropins, is forbidden in the European Union (EU), but is legal in the USA. The misuse of recombinant bovine somatotropin in Italy is suspected for enhancing milk production, thanks to its availability on the illegal market. A synthetic bioactive peptide of 27 amino acids derived from bovine somatotropin was successfully tested in France and in southern Italy for scientific purposes, to stimulate milk production, both in cows and buffaloes. This somatotropin‐like peptide (PEP‐ST), suspected for illegal use in southern Italy, was synthesized by linking the 104–113 sequence of bovine somatotropin to the 323–339 sequence of ovalbumin. Herein, a method for detection and identification of the PEP‐ST in buffalo serum is described; our strategy was based on the production of IgG anti‐PEP‐ST, used to synthesize an immuno‐affinity column for peptide purification from buffalo serum, prior to analysis by ion trap liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI‐MS/MS). The immuno‐affinity column was successfully used to purify in a single step the bioactive PEP‐ST from buffalo serum samples spiked at 20, 50 and 200 µg/mL for confirmatory analysis. Ion trap LC/ESI‐MS/MS identification was based on detection of a multi‐charged molecular ion and its characteristic fragmentation pattern. No significant matrix interference was observed, accounting for method specificity. We consider this strategy to be a basic approach that could be improved in the perspective of the official control of illegal use of somatotropin and somatotropin‐like compounds in buffalo breeding. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

18.
Simple and specific analytical methods for the quantitative determination of sesquiterpenoids from various species of Artemisia plant samples were developed. By LC–UV, LC–ELSD, the separation was achieved by reversed-phase chromatography on a C18 column with water and acetonitrile both containing 0.025% trifluoroacetic acid as the mobile phase. In the LC–MS system, trifluoroacetic acid was replaced by 0.1% formic acid. The wavelength used for quantification of sesquiterpenoids with a diode array detector was 205 nm. The limits of detection by LC–MS was found to be 5, 10, 25, 50, 50 ng mL?1. The limits of detection by LC–UV and LC–ELSD were found to be 5.0, 3.0, 100, 100, 7.5 μg mL?1, by LC–UV and 50, 25, 30, 100 and 75 μg mL?1 by LC–ELSD. LC–mass spectrometry coupled with electrospray ionization (ESI) interface is described for the identification and quantification of sesquiterpenoids in various plant samples. This method involved the use of the [M + H]+ ions of sesquiterpenoids in the positive ion mode with extractive ion monitoring.  相似文献   

19.
A profiling method for glycerophospholipids (GPs) in biological samples was developed using reversed‐phase high‐performance liquid chromatography (RP‐HPLC) coupled to hybrid linear ion trap‐Fourier transform ion cyclotron resonance mass spectrometry (LIT‐FTICRMS) with electrospray ionization (ESI) in the negative ionization mode. The method allowed qualitative (identification and structure elucidation) and relative quantitative determination of various classes of GPs including phosphatidylcholines, phosphatidylethanolamines, phosphatidylinositols, phosphatidylserines, phosphatidic acids, phosphatidylglycerols, and cardiolipins in a single experiment. Chromatographic separation was optimized by the examination of different buffer systems and special emphasis was paid on the detection by ESI‐MS. The hybrid LIT‐FTICRMS system was operated in the data‐dependent mode, switching automatically between FTICRMS survey scans and LIT‐MS/MS experiments. Thereby, exact masses for elemental composition determination and fragmentation data for identification and assignment of fatty acid residues are provided at the same time. The low absolute instrumental limits of detection (0.05 pmol for phosphatidylglycerol to 1 pmol for phosphatidic acid) complemented by a linear dynamic range of 1.5 to 2.5 orders of magnitude facilitated the relative quantification of GP species in a lipid extract from Saccharomyces cerevisiae. The developed method is a valuable tool for in‐depth GP profiling of biological systems. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

20.
A novel, rapid and sensitive liquid chromatography/quadrupole linear ion trap mass spectrometry [LC‐ESI‐(QqLIT)MS/MS] method was developed and validated for the quantification of protopanaxadiol (PPD) in rat plasma. Oleanolic acid (OA) was used as internal standard (IS). A simple protein precipitation based on acetonitrile (ACN) was employed. Chromatographic separation was performed on a Sepax GP‐C18 column (50 × 2.1 mm, 5 μM) with a mobile phase consisting of ACN–water and 1.5 μM formic acid and 25 mM lithium acetate (90 : 10, v/v) at a flow rate of 0.4 ml/min for 3.0 min. Multiple‐reaction‐monitoring mode was performed using lithium adduct ion as precursor ion of m/z 467.5/449.4 and 455.6/407.4 for the drug and IS, respectively. Calibration curve was recovered over a concentration range of 0.5–100 ng/ml with a correlation coefficient >0.99. The limit of detection was 0.2 ng/ml in rat plasma for PPD. The results of the intraday and interday precision and accuracy studies were well within the acceptable limits. The validated method was successfully applied to investigate the pharmacokinetic study of PPD after intravenous and gavage administration to rat. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号