首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 437 毫秒
1.
Seven porous divinylbiphenyl polymers having the same nominal crosslinking degree (51.8 wt.%) have been synthesized using suspension polymerization method in the presence of the following inert diluents or their mixtures: toluene, heptane, dodecane, isooctane. The use of various inert diluents was aimed at changing the extent of polymeric network-diluent interactions. The obtained polymers have specific surface area in the range 50-300 m2/g depending on the type and amount of inert diluents used during polymerization. Their sorptive properties have been studied using dilute (0.5 mmol/l) aqueous solutions of phenol and its derivatives (2-chlorophenol, 2,4-dichlorophenol, 2,4,5-trichlorophenol, 2,6-dimethylphenol, 4-hydroxyphenol). It has been found that sorption, at low equilibrium concentration, follows the order: 2,4,5-trichlorophenol > 2,4-dichlorophenol > 2-chlorophenol > 2,6-dimethylphenol > phenol > 4-hydroxyphenol. Full characteristic of the porous structure of polymers has been obtained by nitrogen adsorption at 77K.  相似文献   

2.
《Analytical letters》2012,45(15):2508-2521
Porous polyaniline coatings doped with different counter ions were electrodeposited on the surface of stainless steel wires using controlled potentiostatic coulometry. Prior to electropolymerization, the stainless steel wires were chemically etched to improve subsequent immobilization of the polyaniline coatings on the substrate and to increase the effective surface area. Porous polyaniline coatings doped with sulfate, nitrate, and perchlorate counter ions were employed for solid-phase microextraction (SPME) of 2-chlorophenol, 2,4-dichlorophenol, triclosan, and 2,4-dichlorophenoxyacetic acid coupled to high-performance liquid chromatography. The results demonstrated that the perchlorate doped polyaniline coating exhibited the highest extraction efficiency for 2-chlorophenol, 2,4-dichlorophenol, and triclosan at pH 5.0, indicating that the extraction capability was modified by introducing different counter ions into the coatings. As a result, the perchlorate doped polyaniline coated fiber was further used for the optimization of extraction condition s . The method provided linear dynamic ranges over 2 to 4 orders of magnitude. The limits of detection were 0.006 µg · L?1, 0.005 µg · L?1, and 0.040 µg · L?1 for 2-chlorophenol, 2,4-dichlorophenol, and triclosan, respectively. The precision expressed as the relative standard deviation ranged from 2.20% to 5.04% for spiked water at 10 µg · L ?1 (n = 5) and the fiber to fiber reproducibility was between 3.27% and 5.91% (n = 5). The method was successfully applied to the determination of chlorophenolics in real water samples. The recoveries of chlorophenolics in spiked water at 5.0 µg · L?1 were between 99.60% and 108.7% with relative standard deviations between 3.24% and 5.47%.  相似文献   

3.
Dispersive liquid–liquid microextraction using deep eutectic solvents, as novel extraction solvents, was developed for the separation, preconcentration, and determination of chlorophenol, 2,3-dihydroxybenzoic acid, p-cresol, 4-chlorophenol, 2,4-dichlorophenol, and 2,4,6-trichlorophenol in vegetable oil. Seven deep eutectic solvents composed of choline chloride and different hydrogen bond donors (ethyl glycol, glycerol, 1,2-butanediol, 1,4-butanediol, 1,6-hexanediol, urea, and acetic acid) were characterized. The deep eutectic solvents formed by choline chloride-1,6-hexanediol in a 1:2 molar ratio provided the highest extraction efficiency. The sonication time, deep eutectic solvent volume, and disperser solvent were optimized. Under the optimal conditions of a sonication time of 11?min, a deep eutectic solvent volume of 90?µL, and acetone as the disperser solvent, extraction recoveries from 76.1 to 88.3% were obtained with 8.46 to 9.46 enrichment factors and the limits of detection exceeding 0.1?µg/mL with the relative standard deviations from 1.0 to 3.5%. This method using dispersive liquid–liquid microextraction with deep eutectic solvents is simple and provides high enrichment.  相似文献   

4.
A simple, sensitive and rapid reversed-phase high-performance liquid chromatography (RP-HPLC) method is proposed for the analysis of some environmentally important phenols in water. The use of coumarin-6-sulphonyl chloride (C6SCl) as a fluorescence-labeling reagent has been investigated. The compound reacts with phenols within 20 min under mild conditions (ambient temperature, pH 9.0) to give sulphonates that can be separated by RP-HPLC employing fluorescence detection at lambda(ex) = 360 and lambda(em) = 460 nm. The optimum conditions for fluorescence, derivatization and chromatographic separation have been established and detection limits in the range 0.1-0.9 microg l(-1) were obtained for the studied compounds. The calibration curves were linear for the range 6-200 microg l(-1) for phenol, 3-200 microg l(-1) for 2-chlorophenol, 4-chlorophenol and 2,3,5-trichlorophenol and for the range of 3-100 microg l(-1) for 2,3-dichlorophenol and 3,5-dichlorophenol. The practical applicability of the method to environmental samples was demonstrated by analyzing drinking and industrial water samples spiked with the phenolic compounds.  相似文献   

5.
A new microemulsion electrokinetic chromatographic method has been established for separation and sensitive analysis of the three chlorophenols 2-chlorophenol, 4-chlorophenol, and 2,4-dichlorophenol. The optimum microemulsion system was 15 mM SDS, 112 mM n-butanol, and 10 mM n-octane in 20 mM sodium tetraborate (pH 9.0). Under the optimum conditions, baseline separation was achieved within 8 min. The method was used for analysis of a real water sample previously pretreated by SPE. The linear ranges, precision of migration time and peak area, and limits of detection (LOD) were in the ranges of 0.5–50 μg L?1, 4.85–9.75%, 0.49–0.706% (n = 6), and 0.6–1 μg L?1, respectively, for the three chlorophenols.  相似文献   

6.
Chlorophenols (CPs) as a mixture of fourteen congeners from mono- to pentachlorophenol were determined using liquid chromatography/electrospray ionization/ion mobility spectrometry (LC/ESI/IMS) to describe the response and analytical performance of a mobility spectrometer as a detector for liquid chromatography. The mobility spectrometer was equipped with an interface so that flows from a large bore column could be electrosprayed directly into the drift tube at flow rates up to 500 μL/min without splitting of flow. A linear gradient of the mobile phase from 40% to 90% methanol and 60% to 10% acetic acid (AcOH)–ammonium acetate buffer solution over 40 min with a C18 column provided baseline separations though mobility spectra for CPs were influenced by mobile phase composition. Product ions formed from CPs with ESI included phenoxide anions CPO?, AcOH·CPO?, CPOH·CPO?, and Na+·(CPO?)2 and were found to be governed by the drift gas temperature. Ions were identified using LC/ESI/mass spectrometry (MS) and supported by results from computational modeling. Quantitative response was affected by congener structure through the acidities of the OH moiety and by the composition of the mobile phase. Limits of detection ranged from 0.135 mg/L for 2,3,5-trichlorophenol and pentachlorophenol to 2.23 mg/L for 2-chlorophenol; corresponding linear ranges were 20 and 70.  相似文献   

7.
Two sensitive and selective stability-indicating methods were developed for the determination of the antibiotic cefpirome sulfate in bulk powder, pharmaceutical formulation and in presence of its acid, alkaline, photo- and oxidative degradation products. Method A was based on HPLC separation of cefpirome sulfate in the presence of its degradation products on a reversed phase column C18, 250 × 4.6 mm, 5-μm particle size and mobile phase consisting of 0.1 M disodium hydrogen phosphate dihydrate pH 3.9 adjusted with phosphoric acid–acetonitrile (85:15, v/v). Quantitation was achieved with UV detection at 270 nm. The linear calibration curve was in the range 5.0–50.0 μg mL?1. Method B was based on reversed phase TLC separation of the cited drug in the presence of its degradation products followed by densitometric measurement of the intact drug at 270 nm. The separation was carried out using disodium hydrogen phosphate dihydrate 2.0 g %w/v, at pH 3.5 adjusted with phosphoric acid–acetone (15:10, v/v) as a developing system. The calibration curve was in the range of 1.0–10.0 μg/spot. The HPLC method was used to study the kinetic of cefpirome sulfate acid degradation. The results obtained were statistically analyzed and compared with those obtained by applying the official Japanese method.  相似文献   

8.
We present a sensitive method for simultaneous determination of bisphenol A (BPA), benzophenone-3 (BP-3), 4-tert-octylphenol (t-OP), ortho-phenylphenol (OPP), four parabens (methyl, ethyl, propyl, butyl parabens) and five chlorophenols (2,4-dichlorophenol (2,4-DCP), 2,5-dichlorophenol (2,5-DCP), 2,4,5-trichlorophenol (2,4,5-triclorophenol), 2,4,6-trichlorophenol (2,4,6-TCP), and triclosan (TCS)), in human urine by high-pressure liquid chromatography (HPLC) mass spectrometry (MS). Samples were processed using enzymatic deconjugation of glucuronides followed by solid phase extraction (SPE) on a C18 cartridge and the eluate was concentrated. Analytes were separated by reversed-phase HPLC and then detected by atmospheric pressure chemical ionisation (APCI) MS and quantified by isotope dilution method. We describe details for optimisation of each step of the procedure. The sample treatment steps are straightforward and not labour-intensive and, therefore, permit a high sample throughput with excellent prospects for automation. This method shows low inter-day variation, and detection limits for most of the compounds are below 1 ng/mL in 1 mL of urine. The method accuracy was also verified by the analysis of proficiency testing urine samples.  相似文献   

9.
Lechner ML  Somogyi MA  Biró ML 《Talanta》1966,13(4):581-587
A quantitative method for the determination of chlorophenols and chlorophenoxyacetic acids in aqueous solutions is described. The samples investigated contained 2-chlorophenol, 2,4-dichlorophenol, 2,6-dichlorophenol, 2,4,6-trichlorophenol and their phenoxyacetic acid derivatives. The total amount of chlorophenols is determined by spectrophotometry, the ratio of individual chlorophenols by gas chromatography and the total quantity of phenoxyacetic acids by acidimetric titration. The determinations are carried out after extraction with diethyl ether, carbon tetrachloride and petroleum ether, respectively.  相似文献   

10.

A new HPLC method based on a mixed mode stationary phase Hypersil Duet C18/SAX was developed and applied for the simultaneous determination of acetaminophen, acetylsalicylic acid and codeine. Parameters, such as the composition of the mobile phase, the nature of the organic modifier, the buffer type and the flow rate were investigated to optimize the separation. The results obtained show that the new HPLC method is rapid, highly efficient and selective. The studied compounds are separated in 10 min, by means of a mobile phase containing phosphate buffer (pH 7.50) and methanol (65:35 v v−1). The retention mechanisms of each analyte were investigated using both the linear solvent strength theory and stoichiometric displacement model. The method was fully validated and showed good linearity for each compound for a concentration ranging between 2.0 and 40 μg mL−1. The limits of detection and quantification were determined and they are lower than 0.1 μg mL−1. The precision (RSD) of the method does not exceed 2 % for all studied compounds. The method was successfully applied for the assay of acetaminophen, acetylsalicylic acid and codeine in pharmaceutical formulations.

  相似文献   

11.
A new HPLC method based on a mixed mode stationary phase Hypersil Duet C18/SAX was developed and applied for the simultaneous determination of acetaminophen, acetylsalicylic acid and codeine. Parameters, such as the composition of the mobile phase, the nature of the organic modifier, the buffer type and the flow rate were investigated to optimize the separation. The results obtained show that the new HPLC method is rapid, highly efficient and selective. The studied compounds are separated in 10 min, by means of a mobile phase containing phosphate buffer (pH 7.50) and methanol (65:35 v v?1). The retention mechanisms of each analyte were investigated using both the linear solvent strength theory and stoichiometric displacement model. The method was fully validated and showed good linearity for each compound for a concentration ranging between 2.0 and 40 μg mL?1. The limits of detection and quantification were determined and they are lower than 0.1 μg mL?1. The precision (RSD) of the method does not exceed 2 % for all studied compounds. The method was successfully applied for the assay of acetaminophen, acetylsalicylic acid and codeine in pharmaceutical formulations.  相似文献   

12.
A magnetic reduced graphene oxide composite (MRGO) was successfully prepared by a simple and green method. MRGO was then used as an adsorbent and found to exhibit enhanced removal efficiency for various chlorophenols (CPs) from water compared with its precursors, graphene oxide (GO) and reduced graphene oxide. The CPs were o-chlorophenol, p-chlorophenol, 2,4-dichlorophenol, and 2,4,6-trichlorophenol. Among them, 2,4,6-trichlorophenol, which exhibited the lowest water solubility and highest molecular weight, most easily bound to MRGO. The preferential interactions between MRGO and CPs were hydrophobic interactions (π-π stacking and hydrophobic effect). This result was confirmed by the equilibrium adsorption behavior in which isotherms were all well described by Freudlich model, indicating heterogeneous and multilayer adsorption. Therefore, CP adsorption was more favored under neutral and acidic conditions, and the decreased removal efficiency of MRGO at higher pH levels was due to the improved hydrophilicity of CPs for deprotonation effect. Moreover, MRGO showed fast removal of each CP, achieving adsorption equilibrium within 10.0 min, presented efficient separation from water under an external magnetic field, and was easily regenerated using dilute NaOH aqueous solution after reaching saturated adsorption. Adsorption capacity of the regenerated MRGO had almost no loss until after five cycles. In summary, MRGO was an efficient adsorbent for the removal of various CPs and had considerable application potential in water treatment.  相似文献   

13.
A metallomesogenic side-chain polymer with copper carboxylato discotic units in stacks prepared by covalent bonding of 14-pentadecenoic acid, stearic acid and poly(methylhydrosiloxane) is described. The physico-chemical and thermal properties of both monomeric and polymeric metallomesogens were determined by elemental analysis, IR, polarizing optical microscopy, thermal gravimetric analysis and differential scanning calorimetry. The polymeric states showed a discotic lamellar phase at 50-95 degrees C and an ordered discotic hexagonal phase at 95-200 degrees C. By dynamic coating, the metallomesogenic polymer was crosslinked to the capillary wall via benzoyl peroxide. The wall-coated capillary columns (15 m x 0.25 mm I.D.) were used for the separation of phenols. Factors affecting the retention and the sample selectivity were examined. Van 't Hoff plots as a function of temperature indicated that phase transitions were occurring. Thermodynamic properties of the analytes in this system were also studied. For the determination of a mixture of 3-aminophenol, 2-chlorophenol, 2-nitrophenol, 4-nitrophenol, o-methylphenol, m-methylphenol, p-methylphenol, 2,4-dichlorophenol, 2,4-dimethylphenol, 2,4-dinitrophenol, 2,4,6-trichlorophenol, 2,4,6-trimethylphenol, 4-bromophenol, 3-methyl-4-chlorophenol, pentachlorophenol, and unsubstituted phenol, the calibration graphs for most phenols were linear over the range of 10-1000 microg ml(-1) and the mass detection limits were in the ng range based on three times standard deviation of seven measurements of the lowest peak that could be detected.  相似文献   

14.
A sensitive and specific liquid chromatography-tandem-mass spectrometry method was developed and validated for the simultaneous determination of clopidogrel and its carboxylic acid metabolite (SR26334) in human plasma using nateglinide and pioglitazone as internal standards. Analytes were extracted from 0.50 mL of plasma using diethyl ether–n-hexane (4:1, v/v). Chromatographic separation was performed on a Teknokroma C18 column with a mobile phase of methanol–water (containing 0.1% formic acid) (80:20, v/v) at a flow rate of 0.20 mL min?1 within 5.6 min. Linearity was established over the concentration range of 0.005–5 ng mL?1 for clopidogrel and 20–2,500 ng mL?1 for SR26334. Intra- and inter-batch standard deviations were less than 9.2% and the accuracy of this assay was found to fall within an acceptable range ≤10.0%. The method was successfully applied to the therapeutic drug monitoring of clopidogrel.  相似文献   

15.
The degradation of 2-(2,4-dichlorophenoxy)-5-chlorophenol (triclosan) in chlorinated water samples was investigated. Sensitive determination of the parent compound and its transformation products was achieved by gas chromatography with mass spectrometry detection after sample concentration, using a solid-phase extraction sorbent and silylation of the target compounds. Experiments were accomplished using ultrapure water spiked with chlorine and triclosan concentrations in the low mg/l and ng/ml ranges respectively. Chlorination of the phenolic ring and cleavage of the ether bond were identified as the main triclosan degradation pathways. Both processes led to the production of two tetra- and a penta-chlorinated hydroxylated diphenyl ether, as well as 2,4-dichlorophenol. The formation of 2,3,4-trichlorophenol was not detected in any experiment; however, significant amounts of 2,4,6-trichlorophenol were noticed. All of these five compounds were also identified when triclosan was added to tap-water samples with free chlorine concentrations below 1 mg/l. Minor amounts of three di-hydroxylated phenols, containing from one to three atoms of chlorine in their structures, were also identified as unstable triclosan chlorination by-products. The analysis of several raw wastewater samples showed the co-existence of important concentrations of triclosan and its most stable by-products (2,4-dichlorophenol and 2,4,6-trichlorophenol), reinforcing the potential occurrence of the described transformations when products containing triclosan are mixed with chlorinated tap water.  相似文献   

16.
《Analytical letters》2012,45(17):3221-3231
Abstract

A simple, rapid, and validated method for separation and determination of terbutaline enantiomers was developed. Terbutaline was separated and determined on a Vancomycin Chirobiotic V column (250 × 4.6 mm), using a mixture of methanol, acetic acid, and triethylamine (100:0.1:0.1% v/v/v) as a mobile phase at 20°C and at a flow rate of 1 ml/min. The UV detector was set to 276 nm. Acetyl salicylic acid (aspirin) was used as an internal standard. The applied high-performance liquid chromatography (HPLC) method allowed separation and quantification of terbutaline enantiomers with good linearity (r > 0.999) in the studied range. The relative standard deviations (RSD) were 1.10 and 1.32% for the terbutaline enantiomers with accuracy of 99.80 and 99.55. The limit of detection and limit of quantification of terbutaline enantiomers were found to be 0.05 and 0.10 µg · ml?1, respectively. The method was validated through the parameters of linearity, accuracy, precision, and robustness. The HPLC method was applied for the quantitative determination of terbutaline in pharmaceutical formulations.  相似文献   

17.
Transition Metal Chemistry - The chlorophenols (CPs), 4-chlorophenol (4-CP), 2,4-dichlorophenol (2,4-DCP) and 2,4,6-trichlorophenol (2,4,6-TCP), are potent environmental hazards. They can be...  相似文献   

18.
Ma  Yanmei  Cheng  Shan  Leski  Michael L.  Luo  Dali  He  Junqi 《Chromatographia》2008,68(11):1027-1032

A rapid and sensitive method for the quantitative determination of picroside II in rat plasma was developed and validated using liquid chromatographic separation with tandem mass spectrometric detection. The analytes of interest were extracted from rat plasma samples by ethyl acetate after acidification with 1.0% acetic acid solution. Chromatographic separation was achieved on a Hypersil GOLD column (50 × 2.1 mm I.D., 5 μm) using a mobile phase consisting of acetonitrile–0.1% formic acid solution (30:70, v/v) at a flow rate of 0.2 mL min−1. Detection was performed on a triple quadrupole tandem mass spectrometer by selected reaction monitoring (SRM) mode via electrospray ionization (ESI). The calibration curve was linear in the concentration range of 1.00–400 ng mL−1 in rat plasma, with a 1.00 ng mL−1 lower limit of quantification (LLOQ). Satisfactory results were achieved for intraday repeatability [relative standard deviation (RSD) = 6.4–12.4%] and inter-day precision (RSD = 6.8–14.7%). The accuracy in terms of relative error ranged from −2.1 to 10.0%. The extraction recoveries of picroside II and icariin (internal standard) were 80.0 and 89.3%, respectively. The developed method was successfully employed to determine picroside II plasma concentrations after oral administration to Wistar rats.

  相似文献   

19.
Zou  Jian-Jun  Fan  Hong-Wei  Guo  Da-Qing  Li  Ying-Bin  Lin  Song  Zhu  Yu-Bing  Yu  Cui-Xia  Zhou  Jie  Liu  Jiang-Hui  Hu  Yun-Fang 《Chromatographia》2009,70(11):1581-1586

A sensitive and specific liquid chromatography-tandem-mass spectrometry method was developed and validated for the simultaneous determination of clopidogrel and its carboxylic acid metabolite (SR26334) in human plasma using nateglinide and pioglitazone as internal standards. Analytes were extracted from 0.50 mL of plasma using diethyl ether–n-hexane (4:1, v/v). Chromatographic separation was performed on a Teknokroma C18 column with a mobile phase of methanol–water (containing 0.1% formic acid) (80:20, v/v) at a flow rate of 0.20 mL min−1 within 5.6 min. Linearity was established over the concentration range of 0.005–5 ng mL−1 for clopidogrel and 20–2,500 ng mL−1 for SR26334. Intra- and inter-batch standard deviations were less than 9.2% and the accuracy of this assay was found to fall within an acceptable range ≤10.0%. The method was successfully applied to the therapeutic drug monitoring of clopidogrel.

  相似文献   

20.
A hypercrosslinked polymeric adsorbent (ZH-03) for adsorbing and removing chlorophenolic compounds from their aqueous solutions was studied, including the static adsorption. The equilibrium adsorption data were fit to Freundlich adsorption isothermic models to evaluate the model parameters. Thermodynamic studies on the adsorption of chlorophenolic compounds on ZH-03 indicated that there were chemisorption transitions for 2,4,6-trichlorophenol and physical adsorption processes for 2-chlorophenol and 2,6-chlorophenol, and ZH-03 showed the homogeneous nature of the adsorbent surface. Column adsorption for chlorophenols wastewater shows the advantages of the ZH-03 adsorbent for adsorbing the following chlorophenolic compounds as 2-chlorophenol, 2,6-dichlorophenol and 2,4,6-trichlorophenol. Sodium hydroxide was used for desorpting chlorophenols from ZH-03 and showed excellent performance.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号