首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
Methylation and demethylation of mercury compounds are two important competing processes that control the net production of highly toxic mercury alkyls, methylmercury (MeHg+) and dimethylmercury (Me2Hg), in environment. Although the microbial and the photochemical methylation and demethylation processes are well studied in recent years but the chemical methylation and demethylation processes have not been studied well. Herein, we report for the first time that the CuSe nanosheet has remarkable ability to activate the highly inert Hg?C bonds of various MeHg+ and Me2Hg compounds at room temperature (21 °C). It facilitates the conversion of MeHg+ into Me2Hg in the absence of any proton donors. Whereas, in the presence of any proton source, it has unique ability to degrade MeHg+ into CH4 and inorganic mercury (Hg2+). Detailed studies revealed that the relatively fast Hg?C bond cleavage was observed in case of MeHgSPh or MeHgI in comparison to MeHgCl, indicating that the Hg?C bond in MeHgCl is relatively inert in nature. On the other hand, the Hg?C bond in Me2Hg is considered to be exceedingly inert and, thus, difficult to cleave at room temperature. However, CuSe nanosheets showed unique ability to degrade Me2Hg into CH4 and Hg2+, via the formation of MeHg+, under acidic conditions at room temperature. DFT calculations revealed that the Hg?C bond activation occurs through adsorption on the surface of (100)‐faceted CuSe nanosheets.  相似文献   

2.
In this work, the quantification of two mercury species (Hg2+ and CH3Hg+) in fish tissues has been revisited. The originality of our approach relies on the use of Bi3+ as internal standard (IS) and on the modification of typical extraction conditions. The IS (125 μl, 1000 μg l−1 Bi3+) was added to the aliquot of fresh fish tissue (400-500 mg). A high-speed blender and ultrasound-assisted homogenization/extraction was carried out in the presence of perchloric acid (1.5 ml, 0.6 mol l−1), l-cysteine (500 μl, 0.75 mol l−1) and 500 μl toluene:methanol (1:1). Perchloric acid was used for protein denaturation and precipitation, toluene helped to destroy lipid structures potentially sequestering CH3Hg+, l-cysteine was used to form water-soluble complexes with Bi3+, Hg2+ and CH3Hg+. The excess of perchloric acid was eliminated by addition of potassium hydroxide (pH 5 with acetic acid). The obtained extract, was diluted with the mobile phase (1:1) and introduced (20 μl) to the reversed phase HPLC-ICP-MS system. The separation was achieved by isocratic elution (2.5 mmol l−1 cysteine, 12.5 mmol l−1 (NH4)2HPO4, 0.05% triethylamine, pH 7.0:methanol (96:4)) at a flow rate 0.6 ml min−1. Column effluent was on-line introduced to ICP-MS for specific detection of 202Hg, 200Hg and 209Bi. Analytical signal was defined as the ratio between 202Hg/209Bi peak areas. The detection limits evaluated for Hg2+ and CH3Hg+ were 0.8 and 0.7 μg l−1. Recovery of the procedure, calculated as the sum of species concentrations found in the sample with respect to total ICP-MS-determined Hg was 91.9% for king mackerel muscle and 89.5% for red snapper liver. In the standard addition experiments, the recovery results were 98.9% for Hg2+ and 100.6% for CH3Hg+. It should be stressed that the use of Bi3+ as IS enabled to improve analytical performance by compensating for incomplete extraction and for imprecision of sample handling during relatively non-rigorous protocol.  相似文献   

3.
A modified automated on-line hyphenated system for simultaneous inorganic ionic mercury (Hg2+) and monomethylmercury (MeHg+) analysis by hydride generation (HG) or ethylation (Eth), cryofocussing, gas chromatography (GC) separation and atomic fluorescence spectrometry (AFS) detection has been improved. Both derivatization methods are investigated with respect to the chromatographic and analytical performances. They can be both affected by interferences when the AFS detection system is used. Water vapor removal using a soda lime moisture trap improves significantly the chromatographic performances, the reproducibility and the detection limits for Hg2+ and MeHg+ analyzed with both methods. For ethylation (Eth) derivatization, a scattering interference generated from low-quality ethylation reagent has also been eliminated. For HG, improved detection limits are 0.13 ng l−1 and 0.01 ng l−1 for Hg2+ and MeHg+, respectively (0.1 l water sample), and reproducibility are 5% for Hg2+ (20 ng l−1) and MeHg+ (5 ng l−1). Improved detection limits for Eth are 0.22 ng g−1 for Hg2+ and 0.02 ng g−1 for MeHg+ (1 g dry sediment sample) and the reproducibility are 5-6% for Hg2+ and MeHg+ (1-2 ng g−1).  相似文献   

4.
A novel nonchromatographic speciation technique for the speciation of mercury by sequential cloud point extraction (CPE) combined with inductively coupled plasma optical emission spectrometry (ICP-OES) was developed. The method based on Hg2+ was complexed with I to form HgI42−, and the HgI42− reacted with the methyl green (MG) cation to form hydrophobic ion-associated complex, and the ion-associated complex was then extracted into the surfactant-rich phase of the non-ionic surfactant octylphenoxypolyethoxyethanol (Triton X-114), which are subsequently separated from methylmercury (MeHg+) in the initial solution by centrifugation. The surfactant-rich phase containing Hg(II) was diluted with 0.5 mol L− 1 HNO3 for ICP-OES determination. The supernatant is also subjected to the similar CPE procedure for the preconcentration of MeHg+ by the addition of a chelating agent, ammonium pyrrolidine dithiocarbamate (APDC), in order to form water-insolvable complex with MeHg+. The MeHg+ in the micelles was directly analyzed after disposal as describe above. Under the optimized conditions, the extraction efficiency was 93.5% for Hg(II) and 51.5% for MeHg+ with the enrichment factor of 18.7 for Hg(II) and 10.3 for MeHg+, respectively. The limits of detection (LODs) were 56.3 ng L− 1 for Hg(II) and 94.6 ng L− 1 for MeHg+ (as Hg) with the relative standard deviations (RSDs) of 3.6% for Hg(II) and 4.5% for MeHg+ (C = 10 μg L−1, n = 7), respectively. The developed technique was applied to the speciation of mercury in real seafood samples and the recoveries for spiked samples were found to be in the range of 93.2–108.7%. For validation, a certified reference material of DORM-2 (dogfish muscle) was analyzed and the determined values are in good agreement with the certified values.  相似文献   

5.
Production of artifact methylmercury (MeHg+) during the analysis of two certified reference sediments, CRM-580 and IAEA-405, was investigated. Leaching of the analyte from the solid sample was achieved by ultrasound assisted acidic extraction. The aqueous leachate was either ethylated (NaBEt4) or phenylated (NaBPh4) using acetic/acetate or citric/citrate to buffer the solution. Preconcentration of the volatile compounds was carried out by extraction with an organic solvent (n-hexane) or solid phase microextraction (SPME). MeHg+ was finally separated and detected by gas chromatography with atomic emission or mass spectrometry detection (GC-MIP-AED or GC-MS). In all the cases the concentrations obtained for MeHg+ in the CRM-580 were significantly higher than the certified value. For the IAEA-405, however, the MeHg+ concentration found was always statistically indistinguishable from the certified value. Experiments were also conducted with synthetic samples, such as aqueous mixtures of MeHg+ and inorganic mercury (Hg2+) or silica-gel spiked with both compounds. The methylation rates found (defined as the percentage of Hg2+ present in the sample which methylates to give artifact MeHg+) ranged from not observable (in certain synthetic aqueous mixtures) to 0.57% (analysis of CRM-580 under certain conditions). As the amount of Hg2+ available in the sample seems to be the main factor controlling the magnitude of the artifact, several experiments were conducted using an ionic exchange resin (Dowex M-41) in order to minimise the concentration of this chemical in the reaction medium. First, a hydrochloric leachate of the sample was passed through a microcolumn packed with the exchanger. Second, the resin was mixed with the sample prior to extraction with HCl. In both cases, the predominant Hg2+ species, HgCl42−, was adsorbed on the resin, whereas MeHg+, mainly as MeHgCl, remained in solution. Following the second option, a new method to analyse MeHg+ in conflictive matrices like certain sediments was proposed. This approach produced better results for the CRM-580, but a MeHg+ concentration slightly, but statistically significant, higher than the reference value was still obtained.  相似文献   

6.
We have combined short-column ion chromatographic separation and on-line photocatalyst-assisted vapor generation (VG) techniques with inductively coupled plasma mass spectrometry to develop a simple and sensitive hyphenated method for the determination of aqueous Hg2+ and MeHg+ species. The separation of Hg2+ and MeHg+ was accomplished on a cation-exchange guard column using a glutathione (GSH)-containing eluent. To achieve optimal chromatographic separation and signal intensities, we investigated the influence of several of the operating parameters of the chromatographic and photocatalyst-assisted VG systems. Under the optimized conditions of VG process, the shortcomings of conventional SnCl2-based VG techniques for the vaporization of MeHg+ was overcome; comparing to the concentric nebulizer-ICP-MS system, the analytical sensitivity of ICP-MS toward the detection of Hg2+ and MeHg+ were also improved to 25- and 7-fold, respectively. With the use of our established HPLC–UV/nano-TiO2–ICP-MS system, the precision for each analyte, based on three replicate injections of 2 ng/mL samples of each species, was better than 15% RSD. This hyphenated method also provided excellent detection limits—0.1 and 0.03 ng/mL for Hg2+ and MeHg+, respectively. A series of validation experiments—analysis of the NIST 2672a Standard Urine Reference Material and other urine samples—confirmed further that our proposed method could be applied satisfactorily to the determination of inorganic Hg2+ and MeHg+ species in real samples.  相似文献   

7.
Different sub-sampling procedures were applied for the determination of mercury species (as total mercury Hg, methylmercury MeHg+ and inorganic mercury Hg2+) in frozen fish meat. Analyses were carried out by two different techniques. After the sample material was pre-treated by microwave digestion, atomic fluorescence spectroscopy (AFS) was used for the determination of total Hg. Speciation analysis was performed according to the following procedure: dissolution of sample material in tetramethylammonium hydroxide (TMAH), derivatisation with sodium tetraethylborate (NaBEt4), extraction into isooctane and measurement with gas chromatography inductively coupled plasma mass spectrometry (GC-ICPMS) for the identification and quantification of methylmercury (MeHg+) and inorganic mercury (Hg2+). The concentration range of total Hg measured in the shark fillets is between 0.9 and 3.6 g g–1 thawed out shark fillet. Speciation analysis leads to 94% Hg present as MeHg+. Homogeneity, storage conditions and stability of analytical species and sample materials have great influence on analytical results. Sub-sampling of half-frozen/partly thawed out fish and analysis lead to significantly different concentrations, which are on average a factor of two lower.  相似文献   

8.
A simple non-chromatographic method for the determination of mercury (Hg2+), methylmercury (MeHg+), dimethylmercury (Me2Hg), and phenylmercury (PhHg+) employing atomic fluorescence spectrometry (AFS) as detection technique was developed. Mercury species showed a particular behavior in the presence of several reagents. In a first stage SnCl2 was employed for Hg2+ determination; in a second step, [Hg2+ + PhHg+] concentration was determined using SnCl2 and UV radiation. MeHg+ decomposition was prevented adding 2-mercaptoethanol. In a third stage, [Hg2+ + PhHg+ + MeHg+] concentration was determined using K2S2O8. Finally, the four species were determined employing NaBH4. Reagents concentration and flow rates were optimized. The extraction technique of mercury species involved the use of 2-mercaptoethanol as ion-pair reagent. The limits of detection for Hg2+, PhHg+, MeHg+, and Me2Hg were 1, 40, 68, and 99 ng L−1 with a relative standard deviation of 1.5, 3.1, 4.7 and 5.8%, respectively. Calibration curve was linear with a correlation factor equal to 0.9995. The method was successfully applied to the determination of the mercury species in two Antarctic materials: IRMM 813 (Adamussium colbecki) and MURST-ISS-A2 (Antarctic Krill).  相似文献   

9.
A diffusive gradient in thin films technique (DGT) was combined with liquid chromatography (LC) and cold vapor atomic fluorescence spectrometry (CV-AFS) for the simultaneous quantification of four mercury species (Hg2+, CH3Hg+, C2H5Hg+, and C6H5Hg+). After diffusion through an agarose diffusive layer, the mercury species were accumulated in resin gels containing thiol-functionalized ion-exchange resins (Duolite GT73, and Ambersep GT74). A microwave-assisted extraction (MAE) in the presence of 6 M HCl and 5 M HCl (55 °C, 15 min) was used for isolation of mercury species from Ambersep and Duolite resin gels, respectively. The extraction efficiency was higher than 95.0% (RSD 3.5%). The mercury species were separated with a mobile phase containing 6.2% methanol + 0.05% 2-mercaptoethanol + 0.02 M ammonium acetate with a stepwise increase of methanol content up to 80% in the 16th min on a Zorbax C18 reverse phase column. The LODs of DGT–MAE–LC–CV-AFS method were 38 ng L−1 for CH3Hg+, 13 ng L−1 for Hg2+, 34 ng L−1 for C2H5Hg+ and 30 ng L−1 for C6H5Hg+ for 24 h DGT accumulation at 25 °C.  相似文献   

10.
An ionic liquid (IL) based dispersive liquid–liquid microextraction combined with HPLC hydride generation atomic fluorescence spectrometry method for the preconcentration and determination of mercury species in environmental water samples is described. Four mercury species (MeHg+, EtHg+, PhHg+, and Hg2+) were complexed with dithionate and the neutral chelates were extracted into IL drops using dispersive liquid–liquid microextraction. Variables affecting the formation and extraction of mercury dithizonates were optimized. The optimum conditions found were as follows: IL‐type and amount, 0.05 g of 1‐octyl‐3‐methylimidazolium hexafluorophosphate; dispersive solvents type and amount, 500 μL of acetone; pH, 6; extraction time, 2 min; centrifugation time, 12 min; and no sodium chloride addition. Under the optimized conditions, the detection limits of the analytes were 0.031 μg/L for Hg2+, 0.016 μg/L for MeHg+, 0.024 μg/L for EtHg+, and 0.092 μg/L for PhHg+, respectively. The repeatability of the method, expressed as RSD, was between 1.4 and 5.2% (n = 10), and the average recoveries for spiked test were 96.9% for Hg2+, 90.9% for MeHg+, 90.5% for EtHg+, 92.3% for PhHg+, respectively. The developed method was successfully applied for the speciation of mercury in environmental water samples.  相似文献   

11.
A simple, rapid and accurate method on the basis of multicapillary gas chromatography (MCGC) combined with inductively coupled plasma-time-of-flight mass spectrometry (ICP-TOFMS) was developed for speciation analysis of methylmercury (MeHg+) and inorganic mercury (Hg2+). The potential of the ICP-TOFMS for transient multi-isotope detection of very short signals (peak width of 0.4 s at half peak height) was evaluated. Two injection systems (purge-and-trap (PTI) and split (SI) injections) were compared in terms of species separation resolution and transient signal profile. Using purge-and-trap injection, after in situ derivatization of the ionic mercury species with sodium tetraethylborate, a baseline separation of MeHg+ and Hg2+ was achieved within a chromatographic run of <35 s. To correct for matrix-induced ion signal variation and instrumental drift, propylmercury (PrHg+) was used as internal standard. Detection limits of 16 and 257 fg g−1 for MeHg+ (as Hg) and Hg2+, respectively, were achieved. The analytical precision (R.S.D. (%)) for 10 successive injections of a standard mixture containing 10 pg MeHg+ (as Hg) and Hg2+ was 1.2% for MeHg+ and 4.1% for Hg2+. The method was validated by analysis of two biological certified reference materials (CRM): a dogfish muscle (DORM-2) and a freeze-dried tuna fish (CRM 464).  相似文献   

12.
Selected new fluorogenic probes that interact in different ways with Hg2+ and MeHg+ have been prepared and used for the chemical speciation of both cations in aqueous solution as well as in HEK293 cells. The best selective speciation of Hg2+ and MeHg+ has been achieved by in vitro approaches based on fluorogenic probes supported in cultured cells, due to the particular sensitivity of the HEK293 cells to permeation by Hg2+, MeHg+ and the fluorogenic probes. In particular, MeHg+ was selectively detected in cell nuclei by probe JG45.  相似文献   

13.
A novel approach for preconcentration and speciation analysis of trace amount of mercury from water samples was proposed by dispersive liquid–liquid microextraction (DLLME) coupled to high performance liquid chromatography with diode array detection (HPLC-DAD). Mercury species (Hg2+, methylmercury (MeHg+) and phenylmercury (PhHg+)) were complexed with dithizone (DZ) to form hydrophobic chelates and then extracted into the fine drops of extraction solvent dispersed in the aqueous sample by dispersive solvent. After extraction, the sedimented phase was analyzed by HPLC-DAD. Some important parameters affecting the DLLME such as extraction solvent and dispersive solvent type and volume, concentration of dithizone solution, sample pH, extraction time and salt effect were investigated. Ionic liquid 1-hexyl-3-methylimidazolium hexafluorophosphate ([HMIM][PF6]) was found to be a suitable extractant for the chelates. Under the optimized conditions (extraction solvent: 70 μL of ionic liquid 1-hexyl-3-methylimidazolium hexafluorophosphate ([HMIM][PF6]); dispersive solvent: 0.75 mL of methanol containing dithizone (0.02%, m/v); pH: 4; extraction time: 5 min; and without salt addition), the limits of detection for Hg2+, MeHg+ and PhHg+ were 0.32, 0.96 and 1.91 μg L−1 (S N−1 = 3) respectively, and the relative standard deviation (RSD) was between 4.1 and 7.3% (n = 5). Three real water samples (tap water, river water and lake water) spiked with mercury species were detected by the developed method, and the relative recoveries obtained for Hg2+, MeHg+ and PhHg+ were 89.6–101.3%, 85.6–102.0% and 81.3–97.6%, respectively.  相似文献   

14.
The monovalent cation monomethylmercury (CH3Hg+) was determined in certified reference materials by isotope dilution GC/ICP-MS and good agreement between measured and certified values has been found. The use of enriched stable isotopes with subsequent detection by ICP-MS is a powerful tracer technique to study dynamic environmental processes. For the first time, it was possible to monitor opposite processes like Hg2+ methylation and CH3Hg+ demethylation at ambient tracer levels simultaneously in the same sample. A scheme for calculating the formation of new species from stable tracers used in environmental studies is presented. The sensitivity of stable tracer methods is superior to traditional tracer or radiotracer techniques. In case of mercury methylation, where the generation of a new compound is monitored, the limit of detection depends only on the precision of the isotope ratio measurements and the concentration of the ambient CH3Hg+ already present in the sample, not on the absolute detection limit of the GC/ICP-MS technique used for analyzing CH3Hg+. A 0.25% change in concentration of CH3Hg+ is detectable. In the case of CH3Hg+ demethylation, where the decrease of the added tracer is monitored, the detection limit again depends on the precision of the isotope ratio measurement and the ambient CH3Hg+ concentration but additionally on the amount of the added tracer as well. A decrease in the CH3Hg+ level of 2% of the added tracer is detectable. The validity of the calculation scheme was tested and no difference was found between individually measured isotope concentrations and calculated concentrations from solutions with multiple stable tracers.  相似文献   

15.
To investigate the effects of mercury species intoxication and to test the efficiency of different commonly applied antidotes, human whole blood and plasma surrogate samples were spiked with inorganic mercury (Hg2+) and methylmercury (MeHg+, CH3Hg+) prior to treatment with the antidotes 2,3-dimercaptopropan-1-ol (British Anti Lewisite), 2,3-dimercaptosuccinic acid (DMSA), and N-acetylcysteine (NAC). For mercury speciation analysis in these samples, liquid chromatography was coupled to either inductively coupled plasma mass spectrometry (ICP-MS) or electrospray ionisation time-of-flight mass spectrometry (ESI-TOF-MS). Adduct formation between mercury species and physiological thiols (cysteine and glutathione) was observed as well as the release of glutathione under treatment with the antidotes DMSA and NAC.  相似文献   

16.
The cloud point extraction (CPE) preconcentration of ultra-trace amount of mercury species prior to reverse-phase high performance liquid chromatography (HPLC) with inductively coupled plasma mass spectrometry (ICP-MS) detection was studied. Mercury species including methyl-, ethyl-, phenyl- and inorganic mercury were transformed into hydrophobic chelates by reaction with sodium diethyldithiocarbamate, and the hydrophobic chelates were extracted into a surfactant-rich phase of Triton X-114 upon heating in a water bath at 40 °C. Ethylmercury was found partially decomposed during the CPE process, and was not included in the developed method. Various experimental conditions affecting the CPE preconcentration, HPLC separation, and ICP-MS determination were optimized. Under the optimized conditions, detection limits of 13, 8 and 6 ng l−1 (as Hg) were achieved for MeHg+, PhHg+ and Hg2+, respectively. Seven determinations of a standard solution containing the three mercury species each at 0.5 ng ml−1 level produced relative standard deviations of 5.3, 2.3 and 4.4% for MeHg+, PhHg+ and Hg2+, respectively. The developed method was successfully applied for the determination of the three mercury species in environmental water samples and biological samples of human hair and ocean fish.  相似文献   

17.
A simple and inexpensive laboratory-built flow injection vapor generation system coupled to atomic absorption spectrometry (FI-VG AAS) for inorganic and total mercury determination has been developed. It is based on the vapor generation of total mercury and a selective detection of Hg2 + or total mercury by varying the temperature of the measurement cell. Only the inorganic mercury is measured when the quartz cell is at room temperature, and when the cell is heated to 650 °C or higher the total Hg concentration is measured. The organic Hg concentration in the sample is calculated from the difference between the total Hg and Hg2 + concentrations. Parameters such as the type of acid (HCl or HNO3) and its concentration, reductant (NaBH4) concentration, carrier solution (HCl) flow rate, carrier gas flow rate, sample volume and quartz cell temperature, which influence FI-VG AAS system performance, were systematically investigated. The optimized conditions for Hg2 + and total Hg determinations were: 1.0 mol l 1 HCl as carrier solution, carrier flow rate of 3.5 ml min 1, 0.1% (m/v) NaBH4, reductant flow rate of 1.0 ml min 1 and carrier gas flow rate of 200 ml min 1. The relative standard deviation (RSD) is lower than 5.0% for a 1.0 μg l 1 Hg solution and the limit of quantification (LOQ, 10 s) is 55 ng g 1. Certified samples of dogfish muscle (DORM-1 and DORM-2) and non-certified fish samples were analyzed, using a 6.0 mol l 1 HCl solution for analyte extraction. The Hg2 + and CH3Hg+ concentrations found were in agreement with certified ones.  相似文献   

18.
The dispersive liquid-liquid microextraction (DLLME) combined with high performance liquid chromatography-inductively coupled plasma mass spectrometry for the speciation of mercury in water samples was described. Firstly methylmercury (MeHg+) and mercury (Hg2+) were complexed with sodium diethyldithiocarbamate, and then the complexes were extracted into carbon tetrachloride by using DLLME. Under the optimized conditions, the enrichment factors of 138 and 350 for MeHg+ and Hg2+ were obtained from only 5.00 mL sample solution. The detection limits of the analytes (as Hg) were 0.0076 ng mL−1 for MeHg+ and 0.0014 ng mL−1 for Hg2+, respectively. The relative standard deviations for ten replicate measurements of 0.5 ng mL−1 MeHg+ and Hg2+ were 6.9% and 4.4%, respectively. Standard reference material of seawater (GBW(E)080042) was analyzed to verify the accuracy of the method and the results were in good agreement with the certified values. Finally, the developed method was successfully applied for the speciation of mercury in three environmental water samples.  相似文献   

19.
A field-adapted procedure based on species-specific isotope dilution (SSID) methodology for trace-level determinations of methyl mercury (CH3Hg+) in mire, fresh and sea water samples was developed, validated and applied in a field study. In the field study, mire water samples were filtered, standardised volumetrically with isotopically enriched CH3200Hg+, and frozen on dry ice. The samples were derivatised in the laboratory without further pre-treatment using sodium tetraethyl borate (NaB(C2H5)4) and the ethylated methyl mercury was purge-trapped on Tenax columns. The analyte was thermo-desorbed onto a GC-ICP-MS system for analysis. Investigations preceding field application of the method showed that when using SSID, for all tested matrices, identical results were obtained between samples that were freeze-preserved or analysed unpreserved. For DOC-rich samples (mire water) additional experiments showed no difference in CH3Hg+ concentration between samples that were derivatised without pre-treatment or after liquid extraction. Extractions of samples for matrix–analyte separation prior to derivatisation are therefore not necessary. No formation of CH3Hg+ was observed during sample storage and treatment when spiking samples with 198Hg2+. Total uncertainty budgets for the field application of the method showed that for analyte concentrations higher than 1.5 pg g–1 (as Hg) the relative expanded uncertainty (REU) was approximately 5% and dominated by the uncertainty in the isotope standard concentration. Below 0.5 pg g–1 (as Hg), the REU was >10% and dominated by variations in the field blank. The uncertainty of the method is sufficiently low to accurately determine CH3Hg+ concentrations at trace levels. The detection limit was determined to be 4 fg g–1 (as Hg) based on replicate analyses of laboratory blanks. The described procedure is reliable, considerably faster and simplified compared to non-SSID methods and thereby very suitable for routine applications of CH3Hg+ speciation analysis in a wide range of water samples.  相似文献   

20.
This paper describes a preconcentration method for Hg2+ and MeHg+ in water samples using sodium diethyldithiocarbamate immobilized in polyurethane foam (PU-NaDDC) and an extraction method for several mercury species in sediment samples, including MeHg+, EtHg+ and PhHg+, which is simple, rapid, and uses a single organic solvent. Separation and measurement were done by high-performance liquid chromatography on-line with inductively coupled plasma mass spectrometry (HPLC/ICP-MS). Initially, the test of recovery was applied using procedures compatible with HPLC. Under the optimum extraction conditions, recoveries of 96.7, 96.3 and 97.3% were obtained for MeHg+, EtHg+, and PhHg+, respectively, from n = 4 spiked sediment samples. This study also demonstrates that the combination of solid-phase extraction on PU-NaDDC with HPLC separation and ICP-MS detection is an effective preconcentration procedure for simultaneous measurement of Hg2+ and MeHg+ at ultra-trace levels in water samples. The application of the proposed procedure to the determination of mercury species in drinking water sample was investigated. The proposed method clearly gave satisfactory average recoveries between 93.7 and 101.5%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号