首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Potentiostatic anodization was developed to synthesize copper oxide/copper (CuxO/Cu, x=1,2) electrode with nano structure for sensitive non-enzymatic glucose detection. At a catalytic potential of 0.55 V, the CuO/Cu electrode presented a high sensitivity of 2954.38 μA mM−1 cm−2 to glucose and a linear range of 0.1 mM to 1.3 mM. The response time is less than 3 s with addition of 0.1 mM glucose. The CuO/Cu electrode above was anodized in 1M KOH solution at −100 mV and the morphology was compact nanoparticles and sparsely dispersed nanosheets, which enlarged the surface area and provided abundant electrocatalytic active sites. Compared the sensing property of electrodes with different morphologies, it indicated that nanostructure was significant to the efficient glucose catalytic oxidation process and it could be regulated by changing the potential and electrolyte concentration during anodization.  相似文献   

2.
A novel and simple glucose sensor based on layer-by-layer (LBL) assembly of Cu and MnO2 nanoparticles on the glassy carbon electrode (Cu/MnO2/GCE) was constructed. The morphology and composition of the Cu and Cu/MnO2 on the electrode surface were observed by scanning electron microscopy and X-ray diffraction. Electrochemical experiments showed that the proposed Cu/MnO2/GCE exhibited excellent electrocatalytic properties to glucose. The oxidation peak currents of glucose on the Cu/MnO2/GCE were linearly related to glucose concentration in a wider linearity range from 0.25???M to 1.02?mM with a correlation coefficient of 0.9977. The sensitivity and detection limit was 26.96???A?mM?1 and 0.1???M (S/N?=?3), respectively. The Cu/MnO2 nanocomposite-modified electrode presented attractive features such as high sensitivity, stability, reproducibility, and interference-free property. The applicability of the proposed method to the determination of glucose in serum samples was demonstrated with satisfactory results.  相似文献   

3.
A high-performance amperometric glucose biosensor was developed, based on immobilization of glucose oxidase (GOx) on a copper (Cu) nanoparticles/chitosan (CHIT)/carbon nanotube (CNT)-modified glassy carbon (GC) electrode. The Cu and CNT had a synergistic electrocatalytic effect toward the reduction of hydrogen peroxide in the matrix of biopolymer CHIT. The Cu/CHIT/CNT modified GC electrode could amplify the reduction current of hydrogen peroxide greatly. Besides, the Cu/CHIT/CNT modified GC electrode reduces hydrogen peroxide at a much lower applied potential and inhibit the responses of interferents. With GOx as an enzyme model, a new glucose biosensor was fabricated. The sensitivity of the sensor is due not only to the large microscopic area but also to the high efficiency of transformation of H2O2 generated by enzymatic reaction to current signal. The biosensor exhibited excellent sensitivity (the detection limit is down to 0.02 mM), fast response time (less than 4 sec), wide linear range (from 0.05 to 12 mM), and perfect selectivity. Correspondence: Wanzhi Wei, State key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha 410082, China  相似文献   

4.
The formation of a Pt(Cu) bimetallic catalyst on the carbon support by galvanic displacement of copper electrodeposits with platinum (PtCl 6 2? as the displacing agent) is systematically studied. Composition, structure, and electrocatalytic properties of samples corresponding to different stages of copper displacement are analyzed. For substantially long displacement times, the formation of stable Pt(Cu)st particles with the atomic ratio Pt: Cu ≈ 7: 3 is observed. The Pt(Cu)st/C electrodes are shown to be close to the Pt/C electrode as regards the adsorption of hydrogen and copper atoms and the specific activity in methanol oxidation (with 0.5 M H2SO4 as the supporting electrolyte). Such electrocatalytic behavior of Pt(Cu)st particles makes it possible to infer the formation of the “core(Pt, Cu)-shell(Pt)” structure, as confirmed by the XPS data.  相似文献   

5.
《Electroanalysis》2018,30(8):1811-1819
Novel copper‐palladium nanoparticles modified glassy carbon electrodes (Cu−Pd/GC) with enhanced nonenzymatic sensing for glucose were facilely prepared by one‐step electrodeposition. The structure and composition of the prepared nanoparticles were characterized by XRD, SEM, TEM and EDS, respectively. The electrode modified process was characterized by electrochemical impedance spectroscopy. Cyclic voltammetry and chronoamperometric experiments were used to evaluate the electrocatalytic activities of the electrodes toward glucose. The surface morphology and the electrocatalytic activities of Cu−Pd/GC was compared to Pd and Cu nanoparticles modified glassy carbon electrodes (Pd/GC and Cu/GC), respectively. Thanks to homogeneous distribution of Cu−Pd nanoparticles and the synergistic effect of Cu and Pd atoms, Cu−Pd/GC exhibited the highest sensitivity (298 μA mM−1 cm−2) and the widest linear amperometric response (0.01 mM to 9.6 mM, R2=0.996) toward glucose compared to Pd/GC and Cu/GC. The detection limit of Cu−Pd/GC was 0.32 μM (S/N=3). In addition, the as‐prepared Cu−Pd/GC glucose sensor also exhibited exceptional capabilities of anti‐interference, reproducibility and long‐term stability. The as‐prepared sensor was also evaluated for determination of glucose concentration in human blood serum samples, which exhibited high reliability and accuracy, having great potential in clinical application.  相似文献   

6.
A novel Prussian blue/copper‐gold bimetallic nanoparticles hybrid film modified electrode was prepared by electrochemical deposition on a glassy carbon electrode (PB/Cu‐AuNPs/GCE). Morphology and electrochemistry of this electrode were studied by UV‐vis spectroscopy, scanning electron microscopy, X‐ray diffraction, cyclic voltammetry and electrochemical impedance spectroscopy. The sensor showed significantly better electrocatalytic activity for the reduction of hydrogen peroxide in comparison with the single PB/GCE and PB/AuNPs/GCE. This was attributed to the synergistic effect of PB and Cu‐Au bimetallic nanoparticles. Also, the sensor demonstrated an overall high level of performance for the analysis of H2O2 in the concentration range from 0.002 to 0.84 mM.  相似文献   

7.
A non-enzymatic sensor was developed for the determination of glucose in alkaline medium by anodisation of copper in sodium potassium tartrate solution. The morphology of the modified copper electrode was studied by scanning electron microscopy, and its electrochemical behavior by cyclic voltammetry and electrochemical impedance spectroscopy. The electrode enables direct electrocatalytic oxidation of glucose on a CuO/Cu electrode at 0.7 V in 0.1 M sodium hydroxide. At this potential, the sensor is highly selective to glucose even in the presence of ascorbic acid, uric acid, or dopamine which are common interfering species. The sensor displays a sensitivity of 761.9 μA mM?1 cm?2, a linear detection range from 2 μM to 20 mM, a response time of <1 s, and a detection limit of 1 μM (S/N = 3). It was tested for determination of glucose level in blood serum.  相似文献   

8.
A new dinudeating ligand consisting of a tetraphanylporphyrin derivative covalently linked with tris(2-benzimidazylmethyl)-amine and its homodinudear Co-Co and heterodinnelear Co-Cu complexes were synthesized and spectroscopically character-ized. The heterobimetallie cobalt-copper complex bearing three benzimidazole ligands for copper, as cytochrome c oxidase ac-tive site model, was applied to the surface of glassy carbon elec-trode to show electrocatalytie activity for O2 reduction in aque-ous solution at an addity level dose to physiological pH value.The kinetic parameters of this electrocatalytic process were ob-tained.  相似文献   

9.
《中国化学》2018,36(1):37-41
A novel Pt/Cu‐zeolite A/graphene based electrocatalyst was successfully prepared by chemical reduction method for methanol electrooxidation. Graphite oxide and Cu functionalized zeolite A were simultaneously reduced by NaBH4 to prepare Cu‐zeolite A/graphene support which was used to deposit Pt nanoparticles. The nanostructure and composition of as‐prepared Pt/Cu‐zeolite A/graphene composites were characterized by X‐ray diffractometer, X‐ray fluorescence, Fourier transform infrared spectrometer and scanning electron microscopy. The electrocatalytic properties of Pt/Cu‐zeolite A/graphene modified electrode for methanol oxidation were investigated by cyclic voltammetry and chronoamperometry in 0.10 mol/L H2SO4 + 0.50 mol/L CH3OH solution. Compared with Pt/zeolite A/graphene electrode and Pt/graphene electrode, Pt/Cu‐zeolite A/graphene based electrode exhibited obviously enhanced current and higher electrocatalytic activity for methanol electrooxidation. The increased electrocatalytic activity was attributed to the presence of zeolite A and reduced graphene oxide based dual template, which significantly increased the effective electrode surface and facilitated the diffusion of analytes into the electroactive catalyst.  相似文献   

10.
We have developed a non-enzymatic glucose sensor by using a composite prepared from copper nanoparticles (CuNPs) and graphene which can be prepared by simple 1-step electrochemical reduction using graphene oxide (GO) and copper ion as the starting materials. The GO is electrochemically reduced to graphene at a voltage of ?1.5 V, and this is accompanied by the simultaneous formation of CuNPs on the surface of the graphene. This novel nanocomposite combines the advantages of graphene and of CuNPs and displays good electrocatalytic activity toward glucose in alkaline media. The performance of the respective glucose electrode was evaluated by amperometric experiments and revealed a fast response (<2 s), a low detection limit (200 nM), and high sensitivity (607 μA mM?1). The sensor also exhibits good reproducibility and very good specificity for glucose over ascorbic acid, dopamine, uric acid, fructose, lactose and sucrose.
Figure
(A) CVs of Cu NPs/graphene electrode (a), graphene electrode (b),and Cu/GC electrode (c) in 0.1 M NaOH solution with 0.5 mM glucose; (B) The response of the Cu NPs/graphene electrode to successive addition of glucose from 5 μM to 0.2 mM.  相似文献   

11.
《Electroanalysis》2017,29(4):965-974
A novel non‐enzymatic carbohydrates sensor which was an indium tin oxide (ITO) glass electrode modified by nickel and copper nanoparticles (Cu/Ni/ITO) was developed by an electrochemical method. The crystallinity, morphology, electrochemical measurements and amperometric response of the as‐prepared ITO modified electrode were examined by the X‐ray diffraction (XRD), scanning electron microscopic (SEM), cyclic voltammetry (CV) and chronoamperometry, respectively. The Cu/Ni/ITO electrode had better electroactivity for glucose oxidation than that obtained using Cu/ITO, Ni/ITO, and Ni/Cu/ITO. The logistic regression equation, Ipa = (A 1A 2)/[1 + (Cglucose /x 0)p ] + A 2, was used to fit the calibration curves of glucose aqueous solution concentrations and responsive current intensity. In research of other saccharides, such as fructose, lactose, sucrose, and maltose, which were detected by the Cu/Ni/ITO electrode, it was obvious that the Cu/Ni/ITO electrode was more sensitive to monosaccharides than disaccharides. Monosaccharides and disaccharides can be detected because the saccharides themselves had aldehyde group or be isomerized to an isomer having an aldehyde group in alkaline environment, and then aldehyde group produced carboxylic acid in the catalytic oxidation of the electrode, which lead to the change of electrode surface conductivity and the appearance of oxidation peak, and the alkaline environment further promotes the above reaction.  相似文献   

12.
Carboxyl graphene modified CuxO/Cu electrode was fabricated. The bare copper electrode was firstly anodic polarized in 1.0 mol/L NaOH solution in order to get CuxO nanoparticles, then the carboxyl graphene (CG) was electrodeposited on the CuxO/Cu electrode by cyclic potential sweeping. The electrocatalytic oxidation behaviors of calcium folinate (CF) at the graphene modified CuxO/Cu electrode were investigated by cyclic voltammetry. A positive scan polarization reverse catalytic voltammetry was used to obtain the pure catalytic oxidation current. The graphene modified CuxO/Cu electrode was served as the electrochemical sensor of CF, a highly sensitivity of 22.0 μA·(μmol/μL)-1cm-2 was achieved, and the current response was linear with increasing CF concentration in the range of 2.0×10-7 mol/L to 2.0×10-5 mol/L, which crossed three orders of magnitude, and the detection limit was found 7.6×10-8 mol/L (S/N=3). In addition, the proposed sensor was successfully applied in determination of CF in drug sample.  相似文献   

13.
Au/TiO2/Ti electrode was prepared by a two-step process of anodic oxidation of titanium followed by cathodic electrodeposition of gold on resulted TiO2. The morphology and surface analysis of Au/TiO2/Ti electrodes was investigated using scanning electron microscopy and EDAX, respectively. The results indicated that gold particles were homogeneously deposited on the surface of TiO2 nanotubes. The nanotubular TiO2 layers consist of individual tubes of about 60–90 nm in diameter, and the electrode surface was covered by gold particles with a diameter of about 100–200 nm which are distributed evenly on the titanium dioxide nanotubes. This nanotubular TiO2 support provides a high surface area and therefore enhances the electrocatalytic activity of Au/TiO2/Ti electrode. The electrocatalytic behavior of Au/TiO2/Ti electrodes in the glucose electro-oxidation was studied by cyclic voltammetry. The results showed that Au/TiO2/Ti electrodes exhibit a considerably higher electrocatalytic activity toward the glucose oxidation than that of gold electrode.  相似文献   

14.
In this work, a novel Cu?zeolite A/graphene modified glassy carbon electrode was applied for the determination of rutin. The Cu?zeolite A/graphene composites were prepared using copper doped zeolite A and graphene oxide as the precursor, subsequently reduced by chemical agents. Based on the Cu?zeolite A/graphene modified electrode, the overpotential of the rutin oxidation was lowered by ~300 mV. Also the proposed Cu?zeolite A/graphene modified electrode showed higher electrocatalytic performance than zeolite A/graphene electrode or graphene modified electrode. The electrochemical behavior of copper incorporated in the zeolite A modified electrode illustrated the adsorption-controlled reaction at the modified electrode. The behavior of electrocatalytic oxidation of rutin at the modified electrode was investigated. The diffusion coefficient of rutin was equal to 4.2 × 10–7 cm2/s. A linear calibration graph was obtained for rutin over the concentration range of 2.3 × 10–7–2.5 × 10–3 M. The detection limit for rutin was 1.2 × 10–7 M. The RSDs of 10 replicate measurements performed on a single electrode at rutin concentrations between 2.3 × 10–7–2.5 × 10–3 M were between 1.1 and 2.1%. Study of the influence of potentially interfering substances on the peak current of rutin showed that the method was highly selective. The proposed electrode was used for the determination of rutin in real samples with satisfactory results.  相似文献   

15.
Based on the adsorption of copper ions on single-walled carbon nanotubes(SWNTs) in electrolyte, Cu/SWNTs nanocomposite film was initially prepared on indium-doped tin oxide(ITO) substrate by one-step electrodeposition. This method may provide a versatile and facile pathway to fabricate other SWNTs-supported metal composite films. Electrochemical experiments revealed that the obtained Cu/SWNTs/ITO electrode offered an excellent electrocatalytic activity towards the oxidation of glucose and could be applied to the construction of non-enzymatic glucose biosensor. The linear range of the sensor was 1.0×10–6 to 6.0×10–4 mol/L and the response time was within 2 s. Particularly, its sensitivity reached as high as 1434.67 μA·L·mmol–1·cm–2, which was superior to any other non-enzymatic glucose biosensor based on copper-carbon nanotubes electrode reported previously.  相似文献   

16.
In this study, NiCu composite coatings were electrochemically deposited on a copper electrode (Cu/NiCu) and characterized by atomic absorption spectroscopy (AAS), scanning electron microscopy (SEM) and scanning electrochemical microscopy (SECM) techniques in view of their possible applications as electrocatalytic materials for the hydrogen evolution reaction (HER). The HER activity of the prepared electrodes were studied in 1 M KOH solution by cathodic current–potential curves and electrochemical impedance spectroscopy (EIS) techniques. It was found that, the NiCu coating has a porous structure and good electrocatalytic activity for the HER in alkaline medium. The HER activity of the Cu/NiCu electrode was higher than uncoated (Cu) and Ni coated (Cu/Ni) copper electrodes. Its catalytic activity was related to the porosity as well as synergistic interaction of Ni and Cu.  相似文献   

17.
In this work, a 304 stainless steel (SS) was anodized to prepare nanoporous SS (NPSS) with an average size of about 75 nm and then filled with copper (Cu/NPSS) using pulsed electrodeposition method. Afterward, a nanostructural Pt and Pd film was deposited by galvanic replacement (GR) on the Cu/NPSS to prepare modified electrode (PtPd/Cu/NPSS) for hydrogen evolution reaction (HER) and formic acid electrooxidation (FAO). The electrocatalytic activity of the modified electrode and its structural characterization have been studied by voltammetric methods, electrochemical impedance spectroscopy (EIS), inductively coupled plasma optical emission spectrometry (ICP-OES), and field emission scanning electron microscopy (FESEM). The results show that the nanostructural Pt1Pd1/Cu/NPSS composition, with low Pt loading and suitable stability, has a good electrocatalytic performance toward HER (EOnset = + 12 mV vs. NHE) and FAO (EOnset = ?180 mV vs. NHE). For HER observed a high mass activity of noble metals (87.54 mA cm?2μg Pd+Pt ?1 ) in comparison with Pt deposited Cu/NPSS (41.5 mA cm?2 μg Pt ?1 ) at the same applied potential of ? 0.25 V versus NHE. Also, the fabricated electrocatalysts with more electrochemically active surface area in comparison with Pd/Cu/NPSS and Pt/Cu/NPSS revealed more resisting to the poisoning components and good stability for FAO.  相似文献   

18.
A novel inorganic–organic hybrid compound constructed from copper(II)-monosubstituted polyoxometalate Na5PW11Cu(H2O)O39 (PW11Cu) and poly(amidoamine) (PAMAM) dendrimer was prepared at room temperature in an aqueous solution. The title compound PW11Cu/PAMAM was characterized by Fourier transform infrared spectroscopy, X-ray photoelectron spectroscopy, and X-ray diffraction, indicating that the PW11Cu was chemically anchored to PAMAM. The compound was first used as a bulk-modifier to fabricate a chemically modified carbon paste electrode (CPE) by direct mixing. The PW11Cu/PAMAM bulk-modified CPE showed well-defined cyclic voltammograms with four redox couples in 0.2 M NaAc buffer solution and high electrocatalytic activity for the reduction of hydrogen peroxide and nitrite. Furthermore, the CPE revealed good stability due to the insolubility of the title compound and the interaction between PW11Cu and PAMAM.  相似文献   

19.
A conductive carbon paste electrode (CPE) comprised of a new copper‐complex of [Cu2(Dpq)2(Ac)2(H2O)2](ClO4)2?H2O (Dpq=dipyrido[3,2‐d : 2′,3′‐f]quinoxaline, Ac=acetate) and carbon powder, was fabricated by the direct mixing method. The electrochemical behavior and electrocatalysis of the new copper‐complex modified CPE (Cu‐CPE) have been studied in detail. Cyclic voltammograms showed that the Cu‐CPE had a favorable electrochemical response of a reversible redox couple of Cu(II)/Cu(I). The Cu‐CPE showed good electrocatalytic activity toward the reduction of the bromate, nitrite and hydrogen peroxide. The electrocatalytic reduction peak current of KBrO3, KNO2 and H2O2 showed a linear dependent on their concentrations. All of the results revealed that the Cu‐CPE had a good reproducibility, remarkable long term stability and especially good surface renewability by simple mechanical polishing in the event of surface fouling, which is important for practical application.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏