首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 102 毫秒
1.
An analytical method for multi-class pharmaceuticals determination in wastewater has been developed and validated. Target compounds were: sulfonamides (sulfadiazine, sulfaguanidine, sulfamethazine, sulfamethoxazole), fluoroquinolones (ciprofloxacin, enrofloxacin, norfloxacin), diaminopyrimidine (trimethoprim), anaesthetic (procaine), anthelmintic (praziquantel and febantel), and macrolide (roxithromycin). The method involves pre-concentration and clean-up by solid-phase extraction (SPE) using Strata-X extraction cartridges at pH 4.0. Target analytes were identified and quantitatively determined by liquid chromatography–tandem mass spectrometry using multiple reaction monitoring (MRM). Recoveries were higher than 50% with relative standard deviation (RSD) below 18.3% for three concentrations. Only for sulfaguanidine was low recovery obtained. Matrix effect was evaluated using matrix-matched standards. The method detection limit (MDL) was between 0.5 and 5 ng L−1 in spiked water samples. The precision of the method, calculated as relative standard deviation, ranged from 0.5 to 2.0% and from 1.4 to 8.3 for intra-day and inter-day analysis, respectively. The described analytical method was used for determination of pharmaceuticals in effluent wastewaters from the pharmaceutical industry.  相似文献   

2.
A simple and robust method suitable for routine analysis of pharmaceuticals from different classes in pharmaceutical industry wastewater samples is presented. Seven veterinary pharmaceuticals (antibiotics and anesthetic) were simultaneously isolated from a highly complex wastewater matrix. Target compounds were three sulfonamide antibiotics (sulfaguanidine, sulfadiazine, and sulfamethazine), three fluoroquinolone antibiotics (ciprofloxacin, enrofloxacin, norfloxacin), and one anesthetic, procaine. The investigated compounds were simultaneously pre-concentrated and cleaned up by solid-phase extraction using Strata-X extraction cartridges. The analysis was performed using liquid chromatography (LC) with diode array and fluorescence detectors connected in series to the chromatographic system. LC separation was performed on a C18 modified column (Phenomenex) with a gradient elution of mobile phase (0.1 % acetic acid in water and 0.1 % acetic acid in acetonitrile) in 25 min at 30 °C. Recoveries ranged from 86.9 to 110 % with relative standard deviations below 10.1 %. Method limits of quantification were in the range of 0.005–0.1 μg L?1 depending on the fluorescence intensity after precolumn derivatization by fluorescamine.  相似文献   

3.
An SPE-HPTLC method for simultaneous identification and quantification of seven pharmaceuticals in production wastewater was optimized and validated. The studied compounds were enrofloxacine, oxytetracycline, trimethoprim, sulfamethazine, sulfadiazine, sulfaguanidine and penicillin G/procaine. The method involves solid-phase extraction on hydrophilic-lipophilic balance cartridges with methanol and HPTLC analysis of extracts on CN modified chromatographic plates followed by videodensitometry at 254 and 366 nm. Optimization of chromatographic separation was performed by systematic variation of the mobile phase composition using genetic algorithm approach and the optimum mobile phase composition for TLC separation was 0.05 M H2C2O4:methanol = 0.81:0.19 (v/v). Linearity of the method was demonstrated in the ranges from 1.5 to 15.0 μg L−1 for enrofloxacine, 100–500 μg L−1 for oxytetracycline, 150–600 μg L−1 for trimethoprim, 300–1100 μg L−1 for sulfaguanidine and 100–400 μg L−1 for sulfamethazine, sulfadiazine and penicillin G/procaine with coefficients of determination higher than 0.991. Mean recoveries ranged from 74.6 to 117.1% and 55.1 to 108.0% for wellspring water and production wastewater, respectively. Only sulfaguanidine showed lower results. The described method has been applied to the determination of pharmaceuticals in wastewater samples from pharmaceutical industry.  相似文献   

4.
This paper focuses on the investigation of different types of SPE sorbents for the preconcentration of eight veterinary pharmaceuticals from water samples. The pharmaceuticals studied were sulfamethazine, sulfadiazine, sulfaguanidine, trimethoprim, oxytetracycline, enrofloxacin, norfloxacin and penicillin G/procaine. Five different SPE materials (Strata‐X, Strata‐X‐C, Strata SDB‐L, Strata C8 and Strata C18) from Phenomenex were compared with Oasis HLB with a view to obtaining the best cartridges for all pharmaceuticals investigated. Extraction efficiency was determined by HPLC with diode array detection (DAD). HPLC‐DAD separation and quantification of the selected pharmaceuticals were carried out under gradient elution by a binary mixture of 0.01 M oxalic acid and ACN based on cyano modified column (LiChrosphere 100 CN) from Merck. Strata‐X provided the best results in the preconcentration of 100 mL water samples, yielding average pharmaceutical recoveries of higher than 90%, except for sulfaguanidine (76.1%). The developed Strata‐X‐HLPC‐DAD method was validated and applied, for the efficient investigation of reverse osmosis/nanofiltration membranes and for the removal of these eight pharmaceuticals from the production wastewater samples. NF90 and XLE membranes were shown to be the best for the rejection of all investigated pharmaceuticals.  相似文献   

5.
Pharmaceuticals constitute one of the most important emerging classes of environmental pollutants. A three‐phase solvent system of water, water containing 0.1% of formic acid and acetonitrile was successfully used to separate, by liquid chromatography with mass spectrometry (LC‐MS), polarity‐matched pharmaceuticals, that is, carbamazepine, clarithromycin, and erythromycin, as well as amoxicillin and metformin. Despite of polarity similarities, these pharmaceuticals were completely resolved in the analytical run time of 15 min. The optimized three‐phase solvent system based‐method was validated for the simultaneous analysis of six matched‐polarity pharmaceuticals in wastewater samples. Good linearity (coefficient of determination more than 0.993) and precision (relative standard deviation less than 15.66%) were achieved. Recovery of analytes from the wastewater was between 0.70 and 1.18. Limits of detections ranged from 0.0001 to 0.5114 µg/L. No significant matrix effect, evaluated by post extraction addition, was observed in the electrospray ionization (ESI) source. Then, this methodology has been successfully applied to environmental study of pharmaceutical residues occurring in influent and effluent wastewater samples, from the main wastewater treatment plant in Potenza (Basilicata, Southern Italy).  相似文献   

6.
In the present work, an analytical method for the simultaneous determination of five anti-inflammatory drugs (acetaminophen, diclofenac, ibuprofen, ketoprofen and naproxen), an antiepileptic drug (carbamazepine) and a nervous stimulant (caffeine) is proposed for the routine analysis of these pharmaceuticals in wastewater influents and effluents from WWTPs. The method involves pre-concentration and clean-up by solid phase extraction (SPE) using Oasis HLB extraction cartridges. Final analysis of the selected pharmaceutical compounds was carried out by high-performance liquid chromatography (HPLC) with diode array detector (DAD). Confirmation of the presence of the fluorescence compounds (ibuprofen and naproxen) was performed by on-line fluorescence detection. Recoveries were ranged from 71 to 103% with relative standard deviation below 15.1%. Limits of quantification were in the range 6.2–319.8 and 3.0–160.0 ng ml−1 for influent and effluent wastewater samples, respectively. The described method was applied to the determination of the drugs in wastewater samples from four treatment plants in Seville.  相似文献   

7.
8.
A simple and sensitive method for simultaneous analysis of 43 pharmaceutical compounds in sewage sludge and sediment samples was developed and validated. The target compounds were extracted using pressurized liquid extraction (PLE) and then purified and pre-concentrated by solid phase extraction (SPE) using a hydrophilic-lipophilic balanced polymer. PLE extraction was performed on temperature of 100 °C, with methanol/water mixture (1/2, v/v) as extraction solvent. The quantitative analysis was performed by liquid chromatography tandem mass spectrometry using a hybrid triple quadrupole-linear ion trap mass spectrometer (LC-QqLIT-MS). Data acquisition was carried out in selected reaction monitoring (SRM) mode, monitoring two SRM transitions to ensure an accurate identification of target compounds in the samples. Additional identification and confirmation of target compounds were performed using the Information Dependent Acquisition (IDA) function. The method was validated through the estimation of the linearity, sensitivity, repeatability, reproducibility and matrix effects. The internal standard approach was used for quantification because it efficiently corrected matrix effects. Despite the strong matrix interferences, the recoveries were generally higher of 50% in both matrixes and the detection and quantification limits were very low. Beside the very good sensitivity provided by LC-QqLIT-MS, an important characteristic of the method is that all the target compounds can be simultaneously extracted, treated and analysed. Hence, it can be used for routine analysis of pharmaceuticals providing large amount of data. The method was applied for the analysis of pharmaceuticals in river sediment and wastewater sludge from three treatment plants with different treatment properties (i.e. capacity, secondary treatment, quality of influent waters). The analysis showed a widespread occurrence of pharmaceuticals in the sludge matrices.  相似文献   

9.
A method using automated on-line solid phase extraction (SPE) directly coupled to liquid chromatography/tandem mass spectrometry (LC-MS/MS) has been developed for the analysis of six pharmaceuticals by isotope dilution. These selected pharmaceuticals were chosen as representative indicator compounds and were used to evaluate the performance of the on-line SPE method in four distinct water matrices. Method reporting limits (MRLs) ranged from 10 to 25 ng/L, based on a 1 mL extraction volume. Matrix spike recoveries ranged from 88 to 118% for all matrices investigated, including finished drinking water, surface water, wastewater effluent and septic tank influent. Precision tests were performed at 50 and 1000 ng/L with relative standard deviations (RSDs) between 1.3 and 5.7%. A variety of samples were also extracted using a traditional off-line automated SPE method for comparison. Results for both extraction methods were in good agreement; however, on-line SPE used approximately 98% less solvent and less time. On-line SPE coupled to LC-MS/MS analysis for selected indicators offers an alternative, more environmentally friendly, method for pharmaceutical analysis in water by saving time and costs while reducing hazardous waste and potential environmental pollution as compared with off-line SPE methods.  相似文献   

10.
A multi-residue method for the analysis of 76 pharmaceutical agents of nine classes of drugs (tetracyclines, macrolides, fluoroquinolones, β-agonists, β-blockers, diuretics, sedatives, sulfonamides and chloramphenicol) in slaughterhouse wastewater and a receiving river is presented. After simultaneous extraction with an Oasis HLB solid-phase extraction (SPE) cartridge and further purification using an amino SPE cartridge, analytes were detected by liquid chromatography–electrospray ionization-tandem mass spectrometry in positive or negative ion mode. Standard addition was used for quantification to overcome unavoidable matrix effects during ESI-MS analysis. Recoveries for most analytes based on matrix-matched calibration in different test matrices were >60%. The method quantification limits of 76 pharmaceuticals were in the range 0.2–30 ng/L. Nineteen compounds of 76 drugs were found in raw and treated slaughterhouse wastewater from four main slaughterhouses in Beijing. Sulfanamides (sulfanilamide, sulfameter), fluoroquenones (ofloxacin, pefloxacin, norfloxacin, ciprofloxacin, enrofloxacin), tetracyclines (tetracycline, oxytetracycline) and macrolides (kitasamycin, tylosin, erythromycin) were most frequently detected, with the highest levels up to ∼3 μg/L in slaughterhouse wastewater and ∼1 μg/L in treated wastewater. Illicit drugs for animal feeding such as clenbuterol and diazepam were commonly detected in slaughterhouse wastewater. These analytes were also observed in a river receiving slaughterhouse wastewater, with a highest level of up to 0.2 μg/L.  相似文献   

11.
This paper describes the development, optimization, and validation of a method for the determination of five pharmaceuticals from different therapeutic classes (antibiotics, anthelmintics, glucocorticoides) in water samples. Water samples were prepared using SPE and extracts were analyzed by HPLC with diode‐array detection. The efficiency of 11 different SPE cartridges to extract the investigated compounds from water was tested in preliminary experiments. Then, the pH of the water sample, elution solvent, and sorbent mass were optimized. Except for optimization of the SPE procedure, selection of the optimal HPLC column with different stationary phases from different manufacturers has been performed. The developed method was validated using spring water samples spiked with appropriate concentrations of pharmaceuticals. Good linearity was obtained in the range of 2.4–200 μg/L, depending on the pharmaceutical with the correlation coefficients >0.9930 in all cases, except for ciprofloxacin (0.9866). Also, the method has revealed that low LODs (0.7–3.9 μg/L), good precision (intra‐ and interday) with RSD below 17% and recoveries above 98% for all pharmaceuticals. The method has been successfully applied to the analysis of production wastewater samples from the pharmaceutical industry.  相似文献   

12.
A pilot-survey study was performed by collecting samples (influent and effluent wastewaters, rivers and tap waters) from different locations in Europe (Spain, Belgium, Germany and Slovenia). A solid-phase extraction (SPE) followed by liquid chromatography–tandem mass spectrometry method was applied for the determination of pharmaceuticals (ibuprofen, naproxen, ketoprofen, diclofenac and clofibric acid). Method detection limits and method quantification limits were at the parts-per-trillion level (7.5–75 ng/L). The recovery rates of the SPE from deionized water and effluent wastewater samples spiked at 100- and 1,000-ng/L levels ranged from 87 to 95%. Identification criteria in compliance with the EU regulation for confirmatory methods of organic residues were applied. A detailed study of signal suppression evaluation for analysis of pharmaceutical residues in effluent wastewaters is presented.  相似文献   

13.
An analytical method was developed to quantitatively determine pharmaceuticals in biosolid (treated sewage sludge) from wastewater treatment plants (WWTPs). The collected biosolid samples were initially freeze dried, and grounded to obtain relatively homogenized powders. Pharmaceuticals were extracted using accelerated solvent extraction (ASE) under the optimized conditions. The optimal operation parameters, including extraction solvent, temperature, pressure, extraction time and cycles, were identified to be acetonitrile/water mixture (v/v 7:3) as extraction solvent with 3 extraction cycles (15 min for each cycle) at 100 °C and 100 bars. The extracts were cleaned up using solid-phase extraction followed by determination by liquid chromatography coupled with tandem mass spectrometry. For the 15 target pharmaceuticals commonly found in the environment, the overall method recoveries ranged from 49% to 68% for tetracyclines, 64% to 95% for sulfonamides, and 77% to 88% for other pharmaceuticals (i.e. acetaminophen, caffeine, carbamazepine, erythromycin, lincomycin and tylosin). The developed method was successfully validated and applied to the biosolid samples collected from WWTPs located in six cities in Michigan. Among the 15 target pharmaceuticals, 14 pharmaceuticals were detected in the collected biosolid samples. The average concentrations ranged from 2.6 μg/kg for lincomycin to 743.6 μg/kg for oxytetracycline. These results indicated that pharmaceuticals could survive wastewater treatment processes, and accumulate in sewage sludge and biosolids. Subsequent land application of the contaminated biosolids could lead to the dissemination of pharmaceuticals in soil and water environment, which poses potential threats to at-risk populations in the receiving ecosystems.  相似文献   

14.
Bag-SPE is a solid-phase extraction (SPE) technique here applied to sample pharmaceutical residues in wastewater. The device, consisting of 20 mg polystyrene-divinylbenzene (PS-DVB) enclosed in a woven polyester fabric was immersed into a 20-mL sample. Extraction of the analytes was performed under gentle rotation (25 rpm) until distribution equilibrium was achieved (4 h). The extraction efficiency for thirteen pharmaceuticals was evaluated for the bag-SPE sampler compared to a conventional SPE cartridge (Oasis HLB). All analyses were determined on an ultra-performance liquid chromatography (UPLC) coupled to a quadrupole time-of-flight (QToF) mass spectrometer. The detection limit of the bag-SPE technique for the analytes in wastewater ranged from 15–100 ng/L with recoveries between 20.7% and 58.2% and ion suppressions between 2.2% and 53.2%. Although the extraction efficiencies were lower with the bag-SPE sampler compared to the SPE technique, the two methods showed similar detection limits due to the lower ion suppression experienced with the bag-SPE. The results demonstrate that bag-SPE is an attractive alternative to the more, in terms of manual handling, demanding SPE technique.  相似文献   

15.
In this work, a fast analytical method based on hydrophilic interaction liquid chromatographic-Ultraviolet detection (HILIC-UV) using a short narrow bore cyano-bonded silica column packed with fully porous sub-2?µm particles has been developed for simultaneous determination of eight pharmaceuticals in wastewater. The method involved pre-concentration and clean-up by solid phase extraction using Oasis HLB extraction cartridges. The analytes were separated using a mobile phase consisted of acetonitrile and 5?mM ammonium acetate buffer (95:5?v/v) with a flow rate of 0.6?mL/min. The chromatographic separation was optimized in order to achieve short analysis time and good resolution for all analytes in a single run. Each analyte was detected at its maximum wavelength for higher sensitivity. All analytes could be separated in 5.7?min with resolution ≥2.7. The optimized method was validated based on linearity, precision, detection and quantification limits, selectivity and accuracy. The detection limits of the studied pharmaceuticals ranged from 0.6 to 3?µg/L, while limits of quantification were in the range from 2 to 10?µg/L with UV detection. The developed method is fast, reliable, cost-effective and could be used for the analysis of the studied analytes in other matrices such as food, pharmaceutical preparations and biological fluids.  相似文献   

16.
《中国化学快报》2020,31(10):2859-2863
The occurrence of biologically active pharmaceuticals in aquatic environments raised the potential risks to aquatic species. Among these marketed biological active pharmaceuticals, it has been estimated that 40% of them target G-protein-coupled receptors (GPCRs). We have illustrated pharmaceutical activities of GPCR targeted pharmaceuticals in English and Japanese wastewater by the in vitro transforming growth factor-α (TGFα) shedding assay. However, as the most important producer and consumer of pharmaceuticals, the occurrence of GPCR targeted pharmaceuticals in China had remained unclear. In this study, we investigated the pharmaceutical activities of GPCR targeted pharmaceuticals in secondary effluents of Chinese wastewater treatment plants. We discovered antagonistic activities against angiotensin (AT1) receptor at up to 7.2 × 102 ng-valsartan-equivalent quantity/L in Chinese wastewater for the first time as well as agonistic activities against dopamine (D2) receptor. Furthermore, in parallel with the assay, we determined concentrations of GPCR targeted pharmaceuticals in target wastewater by liquid chromatography coupled with tandem mass spectrometry (LC–MS/MS). Through the comparison of predicted antagonistic activities calculated by concentrations and potency values from the assay, we found that the measured antagonistic activities against AT1 receptor from the assay were higher than the predicted AT1 activities from valsartan, irbesartan, and losartan, indicating the potential existence of other unknown AT1 antagonists in wastewater.  相似文献   

17.
18.
This work proposes a flow injection analysis system for sulfaguanidine determination in pharmaceutical and food samples. The method was based on the reaction of sulfaguanidine with nitronium ion to produce a colored complex whose absorbance was measured at 545?nm. The flow injection analysis system’s significant parameters were checked by a fractional factorial design 27–2 and optimization by a Doehlert matrix. The flow injection analysis system shows optimum values at 0.28, 2.00, and 0.11% (w/v) for N-naphtil ethylenediamine, ammonium sulfamate, and sodium nitrite concentrations, respectively. The possible interferents present in pharmaceutical and food samples were assessed by a multivariate technique and depicted on probability charts, indicating no significant interferences at the 95% level of confidence interval. The method showed detection and quantification limits of 0.012 and 0.039?mg?L?1, an analytical frequency of 30 readings h?1 and precision always lower than 5.0% expressed as the relative standard deviation. The obtained results were in accordance with those obtained by high-performance liquid chromatography.  相似文献   

19.
An analytical method for the simultaneous determination of eight pharmaceutical compounds in biosolids from urban wastewater treatment plants (WWTPs) was developed and validated. The compounds evaluated were non-steroidal anti-inflammatory drugs (naproxen, diclofenac, and ibuprofen), lipid regulators (clofibric acid), and antibiotics (sulfathiazole, sulfapyridine, sulfamethazine, and sulfamethoxazole). Ultrasound assisted extraction with a water–methanol solvent mixture (1:1, v:v) was performed and the compounds were then determined by liquid chromatography coupled with tandem mass spectrometry. The design of the method was based on the application of the standard addition calibration methodology to reduce matrix interferences. Validation procedures were conducted with rabbit excrements as blank samples. Recoveries of the target analytes ranged from 76 to 131% in spiked samples at 50, 200 or 1000 ng g?1 dry weight (dw). The relative standard deviations were in the range of 5–15% and the method detection limits ranged from 2 to 12 ng g?1dw. The method was applied to monitor pharmaceutical concentrations in biosolids from different WWTPs over an eight-month period (May to December 2011). Diclofenac, sulfapyridine and ibuprofen were detected in most of the samples whereas sulfamethazine and ibuprofen were the pharmaceuticals found in the highest concentrations (>200 ng g?1 dw on average).  相似文献   

20.
In this work, an ultra high-pressure liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method has been developed for the simultaneous quantification and confirmation of the 20 most consumed pharmaceuticals in Spain in urban wastewater and surface water samples. The scope of the method included acidic, neutral and basic compounds belonging to different therapeutic classes and allows their simultaneous determination in just a single injection, giving realistic information of the most widely consumed pharmaceuticals in only one analysis. An enrichment step based on solid-phase extraction using Oasis HLB cartridges was carried out, followed by UHPLC-MS/MS measurement with a fast-acquisition triple quadrupole mass analyzer. It allowed working with short dwell times and made possible to acquire three simultaneous SRM transitions per compound to assure a reliable identification. Several isotope-labelled internal standards were used as surrogates to correct SPE losses, as well as matrix effects that notably affect quantification of analytes. The method was validated in surface water and effluent and influent urban wastewater at different concentrations from 0.005 μg/L (surface water) to 1.25 μg/L (influent wastewater). The optimized method was applied to the analysis of 84 urban wastewater samples (influent and effluent), with the result that 17 out of 20 compounds monitored were detected in the samples. Analgesics and anti-inflamatories, cholesterol lowering statin drugs and lipid regulators were the major groups found, with diclofenac, ketoprofen, naproxen, 4-aminoantipyrine, bezafibrate, gemfibrozil and venlafaxine being the most frequently detected. The highest concentration level reached was 277 μg/L for salicylic acid in influent wastewater.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号