首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
Focused ultrasonic solid-liquid extraction (FUSLE) has been optimised for simultaneous analysis of polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs), phthalate esters (PEs), and nonylphenols (NPs) in sediment samples. Optimisation was performed using naturally polluted freeze-dried sediment samples. The variables studied during the optimisation process were: percentage of maximum power (10-60%), extraction time (10-300 s), number of cycles (1-9), composition of the extraction solvent (acetone-n-hexane, 10:90-90:10), and sample mass (0.1-1 g). The volume of the extractant was constant (10 mL) and the extraction was performed at 0 degrees C in an ice-bath during the optimisation process. All these variables were studied using an experimental design approach by means of The Unscrambler software. The extraction time and the operational variables (number of cycles and power) had no statistically significant effect in the extraction and they were held at 2 min, 20% power, and seven cycles, respectively. The mass and the addition of non-polar solvent (n-hexane) had a negative effect in the extraction yield and, thus, the mass was held at 0.5 g and pure acetone was used as extraction solvent. After those variables were optimised, the effect of the extraction temperature (0 degrees C or room temperature) was also studied. The validation of the extraction method was performed using NIST-1944 reference material in the case of PAHs and PCBs. Because no certified reference sediment is available for PEs and NPs, the results obtained for FUSLE were compared with those obtained for microwave-assisted extraction (MAE) under conditions optimised elsewhere. In all the cases the analysis were performed by gas chromatography-mass spectrometry (GC-MS). Good accuracy were achieved in all cases. The limits of detection (LODs) obtained were between 0.10 and 1.70 ng g(-1) for PAHs (except for naphthalene 5.33 ng g(-1)), 0.02 and 0.16 ng g(-1) for PCBs, 46 and 188 ng g(-1) for PEs, and 0.6 and 12.4 microg g(-1) for NPs. The precision was around 5-10% for most of the PAHs and PCBs and around 2-10% for most of the PEs and NPs.  相似文献   

2.
Stir bar sorptive extraction (SBSE) and thermal desorption followed by capillary gas chromatography coupled to mass spectrometry (SBSE-TD-GC-MS) was applied to the simultaneous determination of ultra-traces of 16 polycyclic aromatic hydrocarbons (PAHs), 12 polychlorinated biphenyls (PCBs), 6 phthalate esters (PEs) and 3 nonylphenols (NPs) in water samples. The parameters that could affect the sorption-desorption efficiency were studied. A Plackett-Burman design was used for the screening of the main effects of the experimental parameters related to the desorption step (desorption time, desorption temperature, desorption flow, cryo-focusing temperature and vent pressure). Afterwards, two central composite designs were used to find the optimal process settings for the extraction and desorption steps. The best analytical compromise conditions for the simultaneous determination of analytes from spiked water samples were found to be: sample volume (20 mL), sodium chloride addition (30%), methanol addition (20%), desorption time (10 min), desorption temperature (300 degrees C), desorption flow (23 mL min(-1)), cryo-focusing temperature (-50 degrees C) and vent pressure (7 psi). Remarkable recovery, repeatability and reproducibility were attained. Furthermore, excellent linearities (r(2) = 0.959-0.999) and low detection limits (0.1-10 ng L(-1)) were also achieved for the congeners studied. The proposed methodology was applied for the simultaneous determination of PAHs, PCBs, PEs and NPs in sea and estuarine waters. The influence of humic acids on the recovery was also studied.  相似文献   

3.
Solid-phase microextraction coupled to GC-MS was optimised for the determination of polycyclic aromatic hydrocarbons (PAHs), phthalate esters and polychlorinated biphenyls (PCBs) in water samples. A 30-microm polydimethylsiloxane fiber was immersed in a 30-ml water sample that contained the analytes of interest (PAHs, PCBs and phthalate esters) and the variables studied were extraction time (15-60 min), extraction temperature (30-90 degrees C), desorption time (1-5 min), desorption temperature (220-270 degrees C) and the addition of sodium chloride (0-9 g). The MultiSimplex programme based on the simplex algorithm was used to establish the optimal conditions. MultiSimplex allowed the simultaneous study of the variables mentioned above and considered the answers of all types of compounds studied in this work. Thus, the optimal conditions obtained allowed the simultaneous determination of PAHs, phthalate esters and PCBs. Furthermore, the accuracy and repeatability of the developed method were calculated from water samples spiked at known concentrations of the analytes. Finally, the optimised method was used to analyse water samples from different sampling points of the Urdaibai and Nerbioi-Ibaizabal estuaries (Biscay, Spain).  相似文献   

4.
Microwave-assisted extraction (MAE) of nonylphenols (NP), nonylphenol mono- and diethoxylates (NP1EO and NP2EO, respectively) and phthalate esters was optimised using an experimental design approach. A D-optimal mixture design was used to optimise the pressure inside the extraction vessel (110-207 kPa), the extraction time (5-25 min) and the extraction solvent (methanol, acetone or n-hexane) or the solvent mixture for the microwave-assisted extraction. Percentage of microwave power (80%) and solvent volume (15 ml) were fixed in all the experiments. As a consequence, the optimum extraction of these compounds was carried out at an intermediate pressure (159 kPa) with pure methanol and during 15 min. Moreover, solid phase extraction was also optimised for the clean-up of the extracts and C-18, LiChrolut® and Oasis® cartridges were studied in order to obtain the best recoveries of the compounds of interest. The highest recoveries were obtained with LiChrolut® cartridges after the elution with ethyl acetate. The cleaned extracts were analysed in a gas chromatograph with mass spectrometric detection and in a liquid chromatograph with diode array and fluorescence detection (HPLC-DAD-UV-FLD). The same sediment was also extracted twice in order to check that an exhaustive extraction of the analytes had occurred. Finally, the optimised extraction method was compared with pressurised solvent extraction (PSE), using an estuarine sediment sample.  相似文献   

5.
This paper describes the development and validation of a new procedure for the simultaneous determination of 41 multi-class priority and emerging organic pollutants in water samples using microextraction by packed sorbent (MEPS) followed by large volume injection–gas chromatography–mass spectrometry (LVI–GC–MS). Apart from method parameter optimization the influence of humic acids as matrix components on the extraction efficiency of MEPS procedure was also evaluated. The list of target compounds includes polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs), phthalate esters (PEs), nonylphenols (NPs), bisphenol A (BPA) and selected steroid hormones. The performance of the new at-line microextraction-LVI–GC–MS protocol was compared to standard solid-phase extraction (SPE) and LVI–GC–MS analysis. LODs for 100 mL samples (SPE) ranged from 0.2 to 736 ng L−1 were obtained. LODs for 800 μL of sample (MEPS) were between 0.2 and 266 ng L−1. In the case of MEPS methodology even a sample volume of only 800 μL allowed to detect the target compounds. These results demonstrate the high sensitivity of both procedures which permitted to obtain good recoveries (>75%) for all cases. The precision of the methods, calculated as relative standard deviation (RSD) was below 21% for all compounds and both methodologies. Finally, the developed methods were applied to the determination of target analytes in various samples, including snow and wastewater.  相似文献   

6.
For the past 25 years the National Institute of Standards and Technology (NIST) has developed certified reference materials (CRMs), known as standard reference materials (SRMs), for determination of organic contaminants in environmental matrices. Assignment of certified concentrations has usually been based on combining results from two or more independent analytical methods. The first-generation environmental-matrix SRMs were issued with certified concentrations for a limited number (5 to 10) of polycyclic aromatic hydrocarbons (PAHs) and polychlorinated biphenyls (PCBs). Improvements in the analytical certification approach significantly expanded the number and classes of contaminants determined. Environmental-matrix SRMs currently available include air and diesel particulate matter, coal tar, marine and river sediment, mussel tissue, fish oil and tissue, and human serum, with concentrations typically assigned for 50 to 90 organic contaminants, for example PAHs, nitro-substituted PAHs, PCBs, chlorinated pesticides, and polybrominated diphenyl ethers (PBDEs). Electronic supplementary material Supplementary material is available in the online version of this article at and is accessible for authorized users.  相似文献   

7.
Two new marine sediment standard reference materials (SRMs), SRM 1941b Organics in Marine Sediment and SRM 1944 New York/New Jersey Waterway Sediment, have been recently issued by the National Institute of Standards and Technology (NIST) for the determination of organic contaminants including polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyl (PCB) congeners, and chlorinated pesticides. Both sediment SRMs were analyzed using multiple analytical methods including gas chromatography/mass spectrometry (GC/MS) on columns with different selectivity, reversed-phase liquid chromatography with fluorescence detection (for PAHs only), and GC with electron capture detection (for PCBs and pesticides only). SRM 1941b has certified concentrations for 24 PAHs, 29 PCB congeners, and 7 pesticides, and SRM 1944 has certified concentrations for 24 PAHs, 29 PCB congeners, and 4 pesticides. Reference concentrations are also provided for an additional 58 (SRM 1941b) and 39 (SRM 1944) PAHs, PCB congeners, and pesticides. SRM 1944, which was collected from multiple sites within New York/New Jersey coastal waterways, has contaminant concentrations that are generally a factor of 10–20 greater than SRM 1941b, which was collected in the Baltimore (Maryland) harbor. These two SRMs represent the most extensively characterized marine sediment certified reference materials available for the determination of organic contaminants.Electronic Supplementary Material Supplementary material is available in the online version of this article at . A link in the frame on the left on that page takes you directly to the supplementary material.  相似文献   

8.
Solid phase extraction (SPE) with appropriate solid sorbents has been commonly used in the routine extraction of organic pollutants in water. The elution of analytes from the solid sorbents normally takes place by organic solvents under an applied vacuum. In this study, a microwave-assisted solvent elution technique was developed for the elution of analytes from C18 membrane disks during microwave irradiation from a microwave extraction system (MES). Several parameters, namely, elution solvent, elution temperature, duration of elution and the volume of solvent which may affect the elution efficiency of microwave-assisted solvent elution (MASE) technique towards organochlorine pesticides (OCPs), polychlorinated biphenyls (PCBs), polycyclic aromatic hydrocarbons (PAHs), phthalate esters (PAEs), organophosphorus pesticides (OPs), fungicides, herbicides and insecticides from the membrane disk were investigated. Good recoveries above 75% were obtained for most of the organic pollutants using the optimum SPE-MASE technique. The effect of sodium chloride and humic acid on the recoveries on the target analytes were also investigated.  相似文献   

9.
Three ionic liquid (IL)-based aggregates, 1-hexadecyl-3-methylimidazolium bromide (HDMIm-Br), 1-hexadecyl-3-butylimidazolium bromide (HDBIm-Br), and 1,3-didodecylimidazolium bromide (DDDDIm-Br) have been applied to the development of a quantitative solid-phase microextraction (SPME)-gas chromatography (GC)-mass spectrometry (MS) method. A sensitivity factor (SF) is defined and introduced for the first time to quantitatively compare the efficiency of the IL-based aggregates by SPME-GC-MS and to evaluate the partitioning strength of several polycyclic aromatic hydrocarbons (PAHs) to the three IL-aggregates. The ILs HDBIm-Br and HDMIm-Br have been used successfully to extract seven PAHs from the certified reference sediment BCR-535 using focused microwave-assisted extraction followed by SPME-GC-MS. Average recoveries for six of the seven certified PAHs were 84.6% for HDMIm-Br and 101% for HDBIm-Br, with relative standard deviation values (RSDs) lower than 19%. The overall extraction method requires short extraction times (around 7 min for the microwave step) and avoids the use of organic solvents.  相似文献   

10.
This study describes the development of a multiresidue method based on gas chromatography-electron ionization-tandem mass spectrometry (GC-EI-MS/MS) for the detection of sixteen polycyclic aromatic hydrocarbons (PAHs), five phthalate esters (PEs), seven polychlorinated biphenyls (PCBs), six polybrominated diphenyl ethers (PBDEs), six alkylphenols (APs), three organochlorined pesticides and their isomers or degradation products (OCPs) and bisphenol A in seawater, river water, wastewater treatment plant (WWTP) effluents, sediments and mussels. Solid phase extraction (SPE) was used for the extraction of target analytes in aqueous samples, and ultrasound assisted extraction for solid samples. GC-EI-MS/MS acquisition conditions in selected reaction monitoring (SRM) using two transitions per compound were optimized. In this way, quantification and unequivocal identification of organic micropollutants were performed in compliance with the Decision 2002/657/EC. Good linearity responses with coefficients of determination higher than 0.99 were obtained. Methodological detection limits (MDLs) in seawater ranged from 0.1 to 6 ng L(-1); in river water from 0.1 to 4.8 ng L(-1); in WWTP effluents from 1 to 75 ng L(-1); in sediments from 1 to 150 ng g(-1) and in mussels from 1 to 125 ng g(-1). MDLs and recovery yields were compared with other published methods and similarities or even improvements were achieved. The optimized method was applied to analyze five samples from each matrix collected in coastal areas, showing its potential use for marine pollution monitoring.  相似文献   

11.
In recent years, the classical Soxhlet extraction of PAHs and PCBs from matrices such as soil, sediments, sludges and related matrices has been substituted by faster and less-solvent-consuming automated techniques. This paper describes the performance characteristics of fluidized-bed extraction (FBE), which has been compared to other approaches and been optimized using a quality control material.SI-traceable reference materials from the European Commission have been used to validate the developed method and establish an analytical protocol. Good correlations with Soxhlet extraction were observed and certified values of the CRMs used, could be confirmed in all cases.  相似文献   

12.
The present work was focused on the development of a simple method aimed at the determination of 12 polycyclic aromatic hydrocarbons (PAHs) and 15 polychlorinated biphenyls (PCBs) in landfill leachates and sediments by adapting a domestic microwave oven to perform microwave-assisted headspace solid-phase microextraction (MA-HS-SPME) followed by gas chromatographic separation and tandem mass spectrometric detection. Good linearity was observed within the concentration range studied; detection limits ranged from 0.1 ng/l to 7 ng/l for PCBs and from 5 ng/l to 926 ng/l for PAHs. Concerning precision, the relative standard deviations obtained were, on average for the leachate and sediment samples analysed, 18% for PCBs and 20% for PAHs. Average recovery values were 37% and 76% for PCBs, and 58% and 48% for PAHs, respectively, for the leachate and reference sediment studied. The method allows the determination of PAHs and PCBs in landfill leachates and sediments, avoiding clean-up steps and the consumption of organic solvents.  相似文献   

13.
A method to determine 21 organochlorine pesticides in animal feed samples using microwave assisted extraction and solid phase extraction cleanup was optimised regarding its main parameters. After extraction with hexane-acetone (50:50), three different sorbents (alumina/ENVI-Florisil, ENVI-Carb and ENVI-Carb II/PSA) were assayed for the cleanup step. Analytes were eluted with hexane-ethyl acetate (80:20) and determined by gas chromatography and electron capture detection followed by gas chromatography-mass spectrometry. ENVI-Carb and ENVI-Carb II/PSA provided colourless eluates but fewer interferent compounds were found in ENVI-Carb II/PSA chromatograms, so this system was selected to carry out the purification of the extracts. The analytical recoveries obtained with this method were close to 100% in most cases with relative standard deviations lower than 10%. These percentages were similar to those obtained with the Soxhlet extraction procedure, which shows the method suitable for the determination of organochlorine pesticides in animal feed material. The method was also validated with the analysis of a certified reference material (CRM-115 BCR), and the results obtained were in good accordance with the certified values.  相似文献   

14.
In this article, a new method for simultaneous determination of six phthalate esters was developed by a combination of electrospun nylon6 nanofibers mat‐based solid phase extraction with high performance liquid chromatography‐ultraviolet detector (HPLC‐UV). The six phthalate esters were dimethyl phthalate (DMP), diethyl phthalate (DEP), butyl benzyl phthalate (BBP), di‐n‐butyl phthalate (DBP), di‐(2‐ethylhexyl) phthalate (DEHP) and dioctyl phthalate (DOP). Under optimized conditions, all target analytes in 50 mL environmental water samples could be completely extracted by 2.5 mg nylon6 nanofibers mat and eluted by 100 µL solvent. Compared with C18 cartridges solid phase extraction, C18 disks solid phase extraction and national standard method (China), nylon6 nanofibers mat‐based solid phase extraction was advantageous in aspects of simple and fast operation, low consumption of extraction materials and organic solvents. The four methods were applied to analysis of environment water samples. All the results indicated that the determination values of target compounds with the proposed method were consistent with C18 cartridges and C18 disks solid phase extraction method, and the new method was better than the national standard method in aspects of recovery, LOD and precision. Therefore, nylon6 nanofibers mat has great potential as a novel material for solid phase extraction.  相似文献   

15.
The decrement of equilibrium extraction time without losing extraction efficiency in solid-phase microextraction (SPME) was achieved using nano-structured coating. Polyaniline (PANI) was used as an extraction phase for the comparison of extraction capacity and equilibrium extraction time of nano- and micro-structured coatings. Polychlorinated biphenyls (PCBs) were used as model compounds to examine the extraction properties of nano- and micro-structured coatings. The results revealed that nano-structured PANI coating showed higher extraction rate and shorter desorption time than micro-structured coating, because of the larger surface area. In order to evaluate the extraction capability of prepared nano-structured PANI coating, headspace-SPME method was used for the determination of PCBs in sediment samples by GC-electron capture detector. The proposed method was validated using the certified reference material.  相似文献   

16.
The feasibility of different clean-up procedures was studied for the determination of polycyclic aromatic hydrocarbons (PAHs) in biota samples such as oysters, mussels and fish liver. In this sense, once the samples were extracted--essentially with acetone and in a microwave system--and before they could be analysed by gas chromatography-mass spectrometry (GC-MS), three different approaches were studied for the clean-up step: solid phase extraction (SPE), microwave-assisted saponification (MAS) and gel permeation chromatography (GPC). The main aim of this work was to maximise the recoveries of PAHs and to minimise the presence of interfering compounds in the last extract. In the case of SPE, Florisil cartridges of 1, 2 and 5 g, and silica cartridges of 5 g were studied. In that case, and with oysters and mussels, microwave-assisted extraction and 5 g Florisil cartridges provided good results. In addition, the concentrations obtained for Standard Reference Material (SRM) NIST 2977 (mussel tissue) were in good agreement with the certified values. In the case of microwave-assisted saponification, the extracts were not as clean as those obtained with 5 g Florisil and this fact lead to overestimate the concentration of the heaviest PAHs. Finally, the cleanest extracts were obtained by GPC. The method was successfully applied to mussels, oysters and hake liver, and the results obtained for NIST 2977 (mussel tissue) were within the confidence interval of the certified reference material for most of the certified analytes.  相似文献   

17.
A simplified extraction method was developed for extracting high molecular weight polycyclic aromatic hydrocarbons (PAHs) from river sediments. The samples were extracted 3 times with 5 mL of solvent (toluene:methanol, 9 : 1, v/v) at 100 °C, 10 minutes for each extraction. After clean‐up and concentration, extracts were analyzed by gas chromatography coupled with mass spectrometer (GC‐MS). The extraction efficiency and accuracy was evaluated by the standard reference material (SRM‐1941b). Comparing to certified values, the average recoveries of high molecular weight PAHs with 3, 4, 5 and 6 fused benzene rings were 72.9∼113.2 % (R.S.D. 2.3∼6.3 %) except those of dibenz[a,h]anthracene (206.2±4.6 %). The average recoveries for PAHs spiked sediment samples were comparable with accelerated solvent extraction (ASE) and Soxhlet methods. The simple extraction method consumes less solvent, fewer amount of sample than those of conventional methods. The lowest quantitation limit of PAHs is 1.1 μg/kg.  相似文献   

18.
Microwave extraction of phthalate esters from marine sediment and soil   总被引:3,自引:0,他引:3  
Summary As part of an on-going ASEAN+)-Canada Cooperative Programme on Marine Science, microwave-assisted solvent extraction has been employed for the extraction of six phthalate esters from marine sediment and soil samples. Five of the six esters studied are among the United States Environmental Protection Agency's list of top priority pollutants. The effects of extraction solvent, extraction temperature, duration of extraction and extraction volume on the mean recoveries of the six phthalate esters were quantitatively evaluated by means of an analysis of variance, followed by testing the differences among the level means for each condition with least significant difference method. Microwave-assisted solvent extraction allowed comparable or higher recoveries of the six phthalate esters (70.1–91.0%) in comparison with conventional soxhlet (65.5–89.5%) and sonication (64.6–88.6%). The precision of results by microwave-assisted solvent extraction was improved significantly compared to the conventional techniques. The microwave extraction system has many advantages over the soxhlet and sonication extraction, e.g., no laborious clean-up procedure, lower usage of hazardous organic solvent, and larger sample throughput. The technique has been employed for the analysis of native marine sediment and soil samples in Singapore.  相似文献   

19.
Methyl mercury was determined by gas chromatography, microwave induced plasma, atomic emission spectrometry (GC-MIP-AES) using two different methods. One was based on extraction of mercury species into toluene, pre-concentration by evaporation and butylation of methyl mercury with a Grignard reagent followed by determination. With the other, methyl mercury was extracted into dichloromethane and back extracted into water followed by in situ ethylation, collection of ethylated mercury species on Tenax and determination. The accuracy of the entire procedure based on butylation was validated for the individual steps involved in the method. Methyl mercury added to various types of soil samples showed an overall average recovery of 87.5%. Reduced recovery was only caused by losses of methyl mercury during extraction into toluene and during pre-concentration by evaporation. The extraction of methyl mercury added to the soil was therefore quantitative. Since it is not possible to directly determine the extraction efficiency of incipient methyl mercury, the extraction efficiency of total mercury with an acidified solution containing CuSO4 and KBr was compared with high-pressure microwave acid digestion. The solvent extraction efficiency was 93%. For the IAEA 356 sediment certified reference material, mercury was less efficiently extracted and determined methyl mercury concentrations were below the certified value. Incomplete extraction could be explained by the presence of a large part of inorganic sulfides, as determined by x-ray absorption near-edge structure spectroscopy (XANES). Analyses of sediment reference material CRM 580 gave results in agreement with the certified value. The butylation method gave a detection limit for methyl mercury of 0.1 ng g(-1), calculated as three times the standard deviation for repeated analysis of soil samples. Lower values were obtained with the ethylation method. The precision, expressed as RSD for concentrations 20 times above the detection limit, was typically 5%.  相似文献   

20.
A new extraction method for the determination of tributyltin (TBT), dibutyltin (DBT) and monobutyltin (MBT) in sediments based on extraction with tartaric acid and methanol has been developed. Tin species were extracted from sediment samples using focused microwave technology, then ethylated with sodium tetraethylborate (NaBEt4) and analyzed by isotope dilution (ID) gas chromatography-mass spectrometry (GC-MS). The advantages of such methodology in comparison with other established extraction methods for the routine speciation analysis of organotin compounds are discussed with respect to sulfur interferences co-extracted from complex matrices.Interferences from elemental sulfur are normally found with acetic acid extraction, but with tartaric acid extraction these interferences were eliminated, demonstrating selective extraction.The accuracy of the analytical procedure was established by analyzing a certified reference material (CRM) (PACS-2, marine sediment) and comparing the results to the certified values. Good agreement between determined and certified values for butyltin compounds was obtained. Finally, some complex sediment samples collected from San Vicente's Bay, Chile, were analyzed with the proposed methodology, demonstrating its potential value for monitoring butyltins in environmental samples with high concentrations of sulfur compounds.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号