首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A speedy and selective ultra‐HPLC‐MS/MS method for simultaneous determination of deoxynivalenol (DON), 3‐acetyldeoxynivalenol (3‐ADON), 15‐ADON, nivalenol and fusarenon X in traditional Chinese medicines (TCMs) was developed. The method was based on one‐step sample cleanup using reliable homemade cleanup cartridges. A linear gradient mobile‐phase system, consisting of water containing 0.2% aqueous ammonia and acetonitrile/methanol (90:10, v/v) at a flow rate of 0.4 mL/min, and an Acquity UPLC HSS T3 column (100 mm×2.1 mm, 1.8 μm) were employed to obtain the best resolution of the target analytes. [13C15]–DON was used as the internal standard to accomplish as accurate as possible quantitation. The established method was further validated by determining the linearity (R2≥0.9990), sensitivity (LOQ, 0.29–0.99 μg/kg), recovery (88.5–119.5%) and precision (RSD≤15.8%). It was shown to be a suitable method for simultaneous determination of DON, 3‐ADON, 15‐ADON, nivalenol and fusarenon X in various TCM matrices. The utility and practical impact of the method was demonstrated using different TCM samples.  相似文献   

2.
Rapid, simple and reliable HPLC/DAD and LC‐ESI‐MS methods for the simultaneous determination of baicalin and forsythin in the traditional Chinese medicinal preparation Shuanghuanglian oral liquid were described and validated. The separation condition for HPLC/DAD was optimized using a BDS hypersil C18 column (Thermo, 2.1 × 150 mm, particle size 5 μm) by gradient elution using methanol‐0.2 % ammonium acetate as the mobile phase. The suitable detection wavelength was set at 277 nm for the quantitative analysis of baicalin and forsythin in this method. Some operational parameters of the ESI interface were optimized, negative m/z 445[M?H]? for baicalin and negative m/z 593[M+CH3COO]? for forsythin, positive m/z 447[M+H]+ for baicalin and positive m/z 552[M+NH 4]+ for forsythin, respectively. These HPLC/DAD and LC‐ESI‐MS methods were validated in terms of recovery, linearity, accuracy and precision (intra‐ and inter‐day validation). These methods can be used as a complementary method for the commercial quality control of Shuanghuanglian oral liquid and its pharmaceutical preparations.  相似文献   

3.
β‐Asarone (BAS), a phenylpropanoid from Acorus calamus Linn., has shown biological effects in the management of cognitive impairment conditions such as Alzheimer's disease. The present paper describes a selective and sensitive liquid chromatography–tandem mass spectrometric method (HPLC‐MS/MS) using electrospray ionization source (ESI) for quantification of BAS in rat plasma. Briefly, the plasma samples were pre‐treated using a simple solid‐phase extraction method. The separation of BAS and the internal standard, caffeine, was achieved on an Agilent Zorbax XDB C18 column (50 × 2.1 mm i.d., 5 µm) using 0.2 mL/min isocratic mobile phase flow. The detection was performed using an Applied Biosystems Hybrid Q‐Trap API 2000 mass spectrometer equipped with an ESI source operated in positive mode. Also, the developed bioanalytical method was validated as per the US FDA bioanalytical guidelines over the concentration range of 9.79–4892.50 ng/mL (r2 ≥ 0.9951) for BAS from rat plasma. The mean percentage recovery (n = 3) for the low, middle and high quality control samples was 86.92 ± 3.89, 85.30 ± 1.09 and 87.24 ± 4.03%, respectively. The applicability of the validated HPLC‐MS/MS method was demonstrated by successful measurement of BAS from plasma following oral administration of Acorus calamus rhizome extracts to three female albino Wistar rats. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

4.
Luteoloside is a potential anticarcinogenic component isolated from Lonicera japonica, a traditional Chinese medicine (TCM). This study details the development and validation of a sensitive and accurate HPLC‐ESI‐MS/MS method for the quantification of luteoloside in dog plasma. Sample pretreatment includes simple protein precipitation using methanol–acetonitrile (1:1, v/v). A Phenomenex Gemini C18 column (2.0 × 50 mm, i.d., 3.5 µm) was used to separate luteoloside and internal standard by gradient mode with mobile phase consisting of water containing 0.1% formic acid and methanol containing 0.1% formic acid at a flow rate of 0.40 mL/min with a column temperature of 25°C. The detection was performed by positive ion electrospray ionization (ESI) in multiple reaction monitoring mode. The calibration curves were linear (R > 0.995) over the concentration range 1.0–2000 ng/mL and the lower limit of quantification was 1.0 ng/mL. The intra‐day and inter‐day precisions (RSD) were all <15%, accuracies (RE) were within the range of ±15%, and recoveries were between 85.0 and 115%. The validated HPLC‐ESI‐MS/MS method was successfully applied to determine plasma concentrations of luteoloside after intravenous administration of luteoloside at a dose level of 20 mg/kg. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

5.
6.
Tolnaftate, a thionoester anti‐fungal drug, was subjected to alkaline hydrolysis to produce methyl(m‐tolyl)carbamic acid and β ‐naphthol (tolnaftate impurity A). N‐Methyl‐m‐toluidine, tolnaftate impurity D, was synthesized and structurally elucidated along with tolnaftate alkaline degradation products using IR, H1NMR and MS. Two stability‐indicating HPTLC and RP‐HPLC methods were developed and validated, for the first time, for determination of tolnaftate, its alkaline degradation products and toxic impurities in the presence of methyl paraben, as a preservative in Tinea Cure® cream. The proposed HPTLC method depended on separation of the studied components on TLC silica gel F254 plates using hexane–glacial acetic acid (8:2, v/v) as a developing system and scanning wavelength of 230 nm. The proposed RP‐HPLC method was based on separation of the five components on an Eclipse plus C18 column. The mobile phase used was acetonitrile–water containing 1% ammonium formate (40:60, v/v), with a flow rate of 1 mL/min and detection wavelength of 230 nm. The proposed methods allowed the assay of tolnaftate toxic impurities, β ‐naphthol and N‐methyl‐m‐toluidine, down to 2%, allowing tracing of β ‐naphthol that could be absorbed by the skin causing systemic toxic effects, unlike tolnaftate, indicating the high significance of such determination. International Conference on Harmonization guidelines were followed for validation.  相似文献   

7.
A new robust high‐performance liquid chromatography/electrospray ionization mass spectrometry (HPLC/ESI‐MS)‐based screening method for angiotensin‐converting enzyme (ACE)‐inhibiting substances in crude samples is described. The ACE assay is carried out in a typical offline setup by incubation of the samples with ACE and angiotensin I (AI), followed by stopping the reaction with acetonitrile containing val5‐AI serving as internal standard (I.S.). AI and the product angiotensin II (AII) are extracted from the incubation mixture by turbulent‐flow chromatography (TFC) applied in backflush mode as online solid‐phase extraction and are directly quantified by ESI(+)‐MS. The presence of ACE inhibitors (ACEi) is detected by an increase in AI signal intensity and a corresponding decrease of AII signal, as compared to the blank assay. The overall time of analysis of the TFC/ESI‐MS method was 5 min, thus making the described setup suitable for a rapid screening method. The assay was validated using a known ACE inhibitor and the IC50 values found were in good accordance with a common HPLC/UV method and literature data. The method was successfully applied for the screening of size‐exclusion chromatography fractions of the venom of the pitviper Bothrops moojeni. Three of 18 analyzed fractions inhibited ACE, due to peptides present as components of this snake venom. These compounds were extracted from the two most‐active fractions by means of TFC and isolated by means of HPLC. Three peptides with ACE inhibitory activity were characterized and their structures were elucidated with ESI‐MS/MS‐based de novo sequencing to be ZKWPPGKVPP, ZKWPRPGPEIPP and ZNWPRPGPEIPP, respectively (Z = pyroglutamic acid). Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

8.
Rapid, simple and reliable HPLC/UV and LC‐ESI‐MS/MS methods for the simultaneous determination of five active coumarins of Angelicae dahuricae Radix, byakangelicol (1), oxypeucedanin (2), imperatorin (3), phellopterin (4) and isoimperatorin (5) were developed and validated. The separation condition for HPLC/UV was optimized using a Develosil RPAQUEOUS C30 column using 70% acetonitrile in water as the mobile phase. This HPLC/UV method was successful for providing the baseline separation of the five coumarins with no interfering peaks detected in the 70% ethanol extract of Angelicae dahuricae Radix. The specific determination of the five coumarins was also accomplished by a triple quadrupole tandem mass spectrometer equipped with an electrospray ionization source (LC‐ESI‐MS/MS). Multiple reaction monitoring (MRM) in the positive mode was used to enhance the selectivity of detection. The LC‐ESI‐MS/MS methods were successfully applied for the determination of the five major coumarins in Angelicae dahuricae Radix. These HPLC/UV and LC‐ESI‐MS/MS methods were validated in terms of recovery, linearity, accuracy and precision (intra‐ and inter‐day validation). Taken together, the shorter analysis time involved makes these HPLC/UV and LC‐ESI‐MS/MS methods valuable for the commercial quality control of Angelicae dahuricae Radix extracts and its pharmaceutical preparations. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

9.
10.
Ding‐Zhi‐Xiao‐Wan (DZXW) is a famous traditional Chinese medicine (TCM) formula, which is composed of four herbs, Ginseng Radix, Poria, Polygala Radix and Acori Tatarinowii Rhizoma. It has been popularly used for the treatment of emotional disease, like Alzheimer's disease, Parkinson's disease, depression, anxiety, forgetfulness and neurasthenia. In this research, a high‐performance liquid chromatography coupled with ion‐trap tandem mass spectrometry (HPLC‐IT‐MSn) method along with a high‐performance liquid chromatography coupled with quadrupole time‐of‐flight mass spectrometry (HPLC‐Q‐TOF‐MS) method in negative ion mode was established to investigate the major constitutions in DZXW. The extracts were prepared by ultra‐sonication in ethyl acetate, n‐butanol, 95% ethanol and deionized water sequentially as well as in deionized water directly. A Kromasil C18 column was used to separate the extracts of DZXW. Acetonitrile and 0.1% aqueous formic acid (V/V) were used as the mobile phase. A total of 64 components were characterized, including 16 triterpenoids, 14 Polygala saponins, 10 oligosaccharide esters, 6 sucrose esters, 2 xanthone C‐glycosides and 16 ginsenosides.  相似文献   

11.
A rapid, selective and sensitive high‐performance liquid chromatography–tandem mass spectrometry (HPLC‐MS/MS) method was developed to determine meloxicam in beagle dog plasma. Sample pretreatment involved a one‐step protein precipitation with methanol of 0.1 mL plasma. Analysis was performed on a Venusil ASB‐C18 column with mobile phase consisting of methanol–water (containing 0.1% formic acid) (75:25, v/v). The detection was performed on a triple quadrupole tandem mass spectrometer by multiple reaction monitoring mode via electrospray ionization source. Each plasma sample was chromatographed within 4.1 min. The linear calibration curves for meloxicam was obtained in the concentration range of 10.3–4.12 × 103 ng/mL (r ≥ 0.99). The intra‐ and inter‐day precisions (relative standard deviation) were ≤ 15%, and accuracy (relative error) was within ±7.3%. The method herein described was fully validated and successfully applied to the pharmacokinetic study of meloxicam tablets in beagle dog.  相似文献   

12.
Heterophyllin B (HB) is a cyclic octapeptide isolated from Pseudostellaria heterophylla. HB is used as the quality control index for evaluating P. heterophylla in the Chinese Pharmacopoeia. A rapid and sensitive LC‐ESI‐MS/MS method was developed and validated for the analysis of HB in rat plasma. Sample preparation consisted of a solid‐phase extraction step for the removal of interference and preconcentration of the target analyte HB and the internal standard N‐acetylcysteine before chromatographic analysis by MS/MS detection. The separation of HB and N‐acetylcysteine was performed using a Hypersil GOLDTM C18 column and a mixture of methanol–water (60:40, v/v) containing 10 mmol/L ammonium formate and 0.1% formic acid as the mobile phase. The determination step was optimized in the selected reaction monitoring mode for the highly selective and sensitive quantitation of HB in rat plasma. Intra‐ and inter‐assay precision (as relative standard deviation) was ≤9.1%, and accuracy was between 92.6 and 102.7%. The validated method was successfully applied to quantify HB concentrations up to 7 h after tail intravenous injections of 2.08, 4.16 and 8.32 mg/kg HB in rats. The LC‐MS/MS method identified the relevant pharmacokinetic parameters of HB and its studied analog. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

13.
A simple, selective and rapid HPLC‐MS/MS method was developed and validated for the determination of caderofloxacin in human plasma. Sparfloxacin was used as the internal standard (IS). After precipitation with methanol and dilution with the mobile phase, the samples were injected into the HPLC‐MS/MS system. The chromatographic separation was performed on a Zorbax XDB Eclipse C18 column (150 × 4.6 mm, 5 µm) with a mobile phase of ammonium acetate buffer (20 mm, pH 3.0)–methanol, 45:55 (v/v). The MS/MS analysis was done in positive mode. The multiple reaction monitoring transitions monitored were m/z 412.3 → 297.1 for caderofloxacin and m/z 393.2 → 292.2 for the IS. The calibration curve was linear over the range of 50.0–8000 ng/mL with an aliquot of 100 μL plasma. The precision of the assay was 2.0–9.4 and 6.6–11.5% for the intra‐ and inter‐run variability, respectively. The intra‐ and inter‐run accuracy (relative error) was 4.4–10.0 and ?1.2–4.0%. The total run time was 3.5 min. The assay was fully validated in accordance with the US Food and Drug Administration guidance. It was successfully applied to a pharmacokinetic study of caderofloxacin in healthy Chinese volunteers. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

14.
A simple and sensitive HPLC–MS/MS method was developed and fully validated for simultaneous determination of ginsenoside Rb1, ginsenoside Rg1, paeoniflorin, albiflorin and oxypaeoniflorin in rat plasma. Plasma samples were pretreated with protein precipitation using acetonitrile. The chromatographic separation was carried out on a C18 column with a gradient mobile phase consisting of acetonitrile and water (containing 0.1% formic acid). All analytes and digoxin (internal stand, IS) were quantitated through electrospray ionization in negative ion multiple reaction monitoring mode. All calibration curves exhibited good linearity (r > 0.9960) over a wide concentration range for all components. The intra‐day and inter‐day precisions (RSD) at three different levels were all <12.0% and the accuracies (RE) ranging from −6.1 to 6.2%. The extraction recoveries of the five compounds ranged from 89.2 to 97.1%. The validated method was successfully applied in a comparative pharmacokinetic study of Wen‐Yang‐Huo‐Xue soft capsule (WYHXSC) in rats. Compared with single pure component, the exposure of the investigated components, except for oxypaeoniflorin, increased after oral administration of WYHXSC in rats, which suggested a synergistic effects between the herbs in the WYHXSC preparations.  相似文献   

15.
Dipyridamole is a classic platelet inhibitor which has been a key medicine in clinical therapy of thrombosis and cerebrovascular disease. A rapid, selective and convenient method using high‐performance liquid chromatography–tandem mass spectrometry (HPLC‐MS/MS) was developed for determination of dipyridamole in human plasma. After protein precipitation of 200 μL plasma with methanol, dipyridamole and diazepam (internal standard) were chromatographed on an Ultimate? XB‐C18 (50 × 2.1 mm i.d, 3 μ) column with the mobile phase consisting of methanol–ammonium acetate (5 mM ; 80 : 20, v/v) at a flow rate of 0.25 mL/min. The detection was performed on a triple quadrupole tandem mass spectrometer by multiple reaction monitoring mode via positive eletrospray ionization source (ESI+). The retention times of dipyridamole and diazepam were 1.4 and 1.2 min, respectively. The method was validated over a concentration range of 0.0180–4.50 μg/mL (r2 ≥ 0.99) with a lower limit of quantitation (LLOQ) of 0.0180 μg/mL for dipyridamole. The intra‐ and inter‐day precisions (RSD) of the assay at all three QC levels were 1.6–12.7% with an accuracy (RE) of ?4.3–1.9%, which meets the requirements of the FDA guidance. The HPLC‐MS/MS method herein described was proved to be suitable for pharmacokinetic study of sustained‐release dipyridamole tablet in volunteers after oral administration. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

16.
Non‐aqueous capillary electrophoresis–mass spectrometry (NACE‐MS) was developed for trace analyses of β‐agonists (i.e. clenbuterol, salbutamol and terbutaline) in pork. The NACE was in 18 mM ammonium acetate in methanol–acetonitrile–glacial acetic acid (66 : 33 : 1, v/v/v) using a voltage of 28 kV. The hyphenation of CE with a time‐of‐flight MS was performed by electrospray ionization interface employing 5 mM ammonium acetate in methanol–water (80 : 20, v/v) as the sheath liquid at a flow rate of 2 μL/min. Method sensitivity was enhanced by a co‐injection technique (combination of hydrodynamic and electrokinetic injection) using a pressure of 50 mbar and a voltage of 10 kV for 12 s. The method was validated in comparison with HPLC–MS‐MS. The NACE‐MS procedure provided excellent detection limits of 0.3 ppb for all analytes. Method linearity was good (r2 > 0.999, in a range of 0.8–1000 ppb for all analytes). Precision showed %RSDs of <17.7%. Sample pre‐treatment was carried out by solid‐phase extraction using mixed mode reversed phase/cation exchange cartridges yielding recoveries between 69 and 80%. The NACE‐MS could be successfully used for the analysis of β‐agonists in pork samples and results showed no statistical differences from the values reported by the Ministry of Public Health, Thailand using HPLC‐MS‐MS method. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

17.
In the present study, an effective high performance liquid chromatography–tandem mass spectrometric (HPLC/MS/MS) method was developed and validated to simultaneously determine bupropion (BUP), quetiapine (QUE) and escitalopram (ESC) in human plasma using carbidopa as the internal standard. Chromatographic separation was achieved on a Waters Sun Fire C18 column using reversed‐phase chromatography. The MS/MS experiment was performed in positive ion multiple reaction monitoring mode to produce product ions of m/z 240.3 → 184.2 for BUP, 384.2 → 253.1 for QUE, 325.3 → 109.3 for ESC and 227.2 → 181.2 for the internal standard. The method showed good linearity (R2 ≥ 0.997), precision (relative standard deviation ≤7.5%), satisfactory intra‐ and interday accuracy (88.4–113.0%) and acceptable extraction recovery (87.2–115.0%), matrix effect (84.5.5?108.7%) and stability (92.3?103.5%). The method was successfully applied to determine the concentrations of BUP, QUE and ESC in human plasma samples. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

18.
A liquid chromatography–tandem mass spectrometric (LC‐MS/MS) method was developed and validated for the determination of GDC‐0152 in human plasma to support clinical development. The method consisted of a solid‐phase extraction for sample preparation and LC‐MS/MS analysis in the positive ion mode using TurboIonSprayTM for analysis. d7‐GDC‐0152 was used as the internal standard. A linear regression (weighted 1/concentration2) was used to fit calibration curves over the concentration range of 0.02–10.0 ng/mL for GDC‐0152. There were no endogenous interference components in the blank human plasma tested. The accuracy at the lower limit of quantitation was 99.3% with a precision (%CV) of 13.9%. For quality control samples at 0.0600, 2.00 and 8.00 ng/mL, the between‐run %CV was ≤8.64. Between‐run percentage accuracy ranged from 98.2 to 99.6%. GDC‐0152 was stable in human plasma for 363 days at ?20°C and for 659 days at ?70°C storage. GDC‐0152 was stable in human plasma at room temperature for up to 25 h and through three freeze–thaw cycles. In whole blood, GDC‐0152 was stable for 12 h at 4°C and at ambient temperature. This validated LC‐MS/MS method for determination of GDC‐0152 was used to support clinical studies. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

19.
20.
A liquid chromatography–triple quadrupole mass spectrometric (LC‐MS/MS) method was developed and validated for the determination of 5‐nitro‐5′‐hydroxy‐indirubin‐3′‐oxime (AGM‐130) in human plasma to support a microdose clinical trial. The method consisted of a liquid–liquid extraction for sample preparation and LC‐MS/MS analysis in the positive ion mode using TurboIonSprayTM for analysis. d3‐AGM‐130 was used as the internal standard. A linear regression (weighted 1/concentration) was used to fit calibration curves over the concentration range of 10–2000 pg/mL for AGM‐130. There were no endogenous interference components in the blank human plasma tested. The accuracy at the lower limit of quantitation was 96.6% with a precision (coefficient of variation, CV) of 4.4%. For quality control samples at 30, 160 and 1600 pg/mL, the between run CV was ≤5.0 %. Between‐run accuracy ranged from 98.1 to 101.0%. AGM‐130 was stable in 50% acetonitrile for 168 h at 4°C and 6 h at room temperature. AGM‐130 was also stable in human plasma at room temperature for 6 h and through three freeze–thaw cycles. The variability of selected samples for the incurred sample reanalysis was ≤12.7% when compared with the original sample concentrations. This validated LC‐MS/MS method for determination of AGM‐130 was used to support a phase 0 microdose clinical trial. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号