首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
An analytical method for the determination of bisoprolol in human plasma has been developed based on liquid chromatography-tandem mass spectrometry (LC-MS/MS). The analyte and internal standard (IS) diphenhydramine were cleaned up by protein precipitation with acetonitrile, reconstituted in mobile phase and separated by reversed-phase high-performance liquid chromatography (HPLC) using methanol:10 mm ammonium acetate:formic acid (70:30:0.1 v/v/v) as mobile phase. Detection was carried out by multiple reaction monitoring (MRM) on an LC-MS/MS system and was completed within 2.5 min. The assay was linear over the range 0.5-100 ng/mL with a limit of quantitation (LOQ) of 0.5 ng/mL. The intra- and inter-day precision levels were within 5.54 and 9.95%, respectively, while the accuracy was in the range 89.4-113%. This method has been utilized in a pharmacokinetic study, where healthy volunteers were treated with an oral dose of 5 mg bisoprolol.  相似文献   

2.
李芳  李佳杨  张华燕  郭兴杰 《色谱》2008,26(6):766-768
采用直链淀粉手性固定相高效液相色谱法在正相条件下直接拆分了比索洛尔对映异构体。分别以异丙醇、乙醇为有机改性剂,考察了流动相的组成与配比、流速及柱温等因素对比索洛尔对映体分离的影响。确定了比索洛尔对映体的最佳拆分条件:流动相正己烷-乙醇-二乙胺(体积比为88∶12∶0.1),流速0.6 mL/min,检测波长270 nm,柱温20 ℃。该方法可快捷、简便地拆分比索洛尔对映体。  相似文献   

3.
荧光法测定尿中的富马酸比索洛尔   总被引:2,自引:0,他引:2  
建立了直接测定尿中富马酸比索洛尔的荧光分光光度法。荧光强度与富马酸比索洛尔含量在100-1000ng/mL范围内呈线性关系。检测限20ng/mL。对浓度100ng/mL与500ng/mL的标准溶液进行测定,其回收率分别为95.6%和99.6%,相对标准偏差为5.6%和2.3%,可用于 尿中富马酸比索洛尔含量的测定。  相似文献   

4.
A sensitive HPLC method with pre-column fluorescence derivatization using 4-Fluoro-7-Nitrobenzofurazan (NBD-F) has been developed for the determination of gabapentin in pharmaceutical preparations. The method is based on the derivatization of gabapentin with (NBD-F) in borate buffer of pH 9.5 to yield a yellow, fluorescent product. The HPLC separation was achieved on a Inertsil C(18) column (250 mm × 4.6 mm) using a mobile phase of methanol water (80:20, v/v) solvent system at 1.2 mL/min flow rate. Mexiletine was used as the internal standard. The fluorometric detector was operated at 458 nm (excitation) and 521 nm (emission). The assay was linear over the concentration range of 5 50 ng/mL. The method was validated for specificity, linearity, limit of detection, limit of quantification, precision, accuracy, robustness. Moreover, the method was found to be sensitive with a low limit of detection (0.85 ng/mL) and limit of quantitation (2.55 ng/mL). The results of the developed procedure for gabapentin content in capsules were compared with those by the official method (USP 32). Statistical analysis by t- and F-tests, showed no significant difference at 95 confidence level between the two proposed methods.  相似文献   

5.
This work describes two high-performance liquid chromatographic methods for the individual determination of bisoprolol and metoprolol in human plasma. Analytical methods involve two different liquid-liquid extractions of human plasma, with diethyl ether for bisoprolol and with dichloromethane for metoprolol, coupled with a similar Nucleosil C(18) reversed-phase HPLC column. Fluorimetric detection was used to identify both beta-blockers. Retention times for bisoprolol and metoprolol were 8.7 and 3.2 min, respectively. Linear regressions for the calibration curves were linear at a concentration range of 6.25-200 ng/mL. Intra- and inter-day precision coefficients of variations and accuracy bias were acceptable (within 15%) over the entire range for both drugs. Average recovery was 89% for metoprolol and 98% for bisoprolol. Once the methods had been validated, analytical error functions were established as standard deviation (SD; ng/mL) = 2.216 + 3.608 x 10(-4)C(2) (C = theoretical concentration value) and SD-(ng/mL) = 0.408 + 0.378 x 10(-1)C for bisoprolol and metoprolol, respectively. The methods developed and their associated analytical error functions will be suitable for pharmacokinetic studies and for determination of plasma concentration if posology individualization of these drugs is needed.  相似文献   

6.
A new, simple, and reproducible method for determination of carboxylic acid metabolite of clopidogrel in human plasma has been developed. After liquid-liquid extraction in acidic medium with chloroform, samples were quantified on a Nova-pak C(8), 5 microm column using a mixture of 30 mM K(2)HPO(4)-THF-acetonitrile (pH = 3, 79:2:19, v/v/v) as mobile phase with UV detection at 220 nm. The flow rate was set at 0.9 mL/min. Ticlopidine was used as internal standard and the total run time of analysis was about 12 min. The method was linear over the range of 0.2-10 microg/mL of clopidogrel metabolite in plasma (r(2) > 0.999). The within-day and between-day precision values were in the range 1.0-4.8%. The limit of quantification of the method was 0.2 microg/mL. The method was successfully used to study the pharmacokinetics of clopidogrel in healthy volunteers.  相似文献   

7.
张荣  刘昌辉  王宁生  宓穗卿 《色谱》2008,26(1):80-83
建立了一种快速、高效的以睾酮作为探针药物评价细胞色素P450 3A4(CYP3A4)酶活性的高效液相色谱-紫外检测方法。采用的色谱柱为Phenomenex C18柱(4.6 mm×150 mm,5 μm),梯度洗脱,流速1.0 mL/min,紫外检测波长245 nm,柱温30 ℃。睾酮与大鼠肝微粒体温孵后,过已活化好的C18固相萃取小柱,收集甲醇洗脱液,于37 ℃水浴中通N2吹干,用50%甲醇复溶后进样分析测定。研究结果表明,6β-羟基睾酮的 保留时间为11.60 min,线性范围为0.5~32 μg/mL,最低检出质量浓度为0.02 μg/mL,提取率为88.41%~92.73%,方法的回收率为99.07%~101.30%;睾酮的保留时间为19.27 min,线性范围为0.5~40 μg/mL,最低检出质量浓度为0.01 μg/mL,提取率为89.59%~92.66%,方法的回收率为96.50%~98.03%。两者的日内、日间相对标准偏差均小于10%,温孵体系中的其他内源性物质不干扰测定。该方法快速、稳定、灵敏度高,适合体外睾酮及其代谢物6β-羟基睾酮的测定,可应用于体外CYP3A4酶活性的评价及酶动力学的研究。  相似文献   

8.
A novel precolumn derivatization reversed-phase high-performance liquid chromatography method with fluorescence detection is described for the determination of ranitidine in human plasma. The method was based on the reaction of ranitidine with 4-fluoro-7-nitrobenzo-2-oxa-1,3-diazole forming yellow colored fluorescent product. The separation was achieved on a C(18) column using methanol-water (60:40, v/v) mobile phase. Fluorescence detection was used at the excitation and emission of 458 and 521 nm, respectively. Lisinopril was utilized as an internal standard. The flow rate was 1.2 mL/min. Ranitidine and lisinopril appeared at 3.24 and 2.25 min, respectively. The method was validated for system suitability, precision, accuracy, linearity, limit of detection, limit of quantification, recovery and robustness. Intra- and inter-day precisions of the assays were in the range of 0.01-0.44%. The assay was linear over the concentration range of 50-2000 ng/mL. The mean recovery was determined to be 96.40 ± 0.02%. This method was successfully applied to a pharmacokinetic study after oral administration of a dose (150 mg) of ranitidine.  相似文献   

9.
An HPLC method was developed and validated for the determination of ethacridine lactate in human urine. Solid-phase extraction cartridges were used to extract urine samples. Separation was carried out on a C(18) column maintained at 30 degrees C with methanol-0.05% sodium dodecylsulfonate (70:30, v/v, pH 3) as mobile phase at a flow rate of 1.0 mL/min. Detection was at UV 272 nm. The calibration curve was linear in the concentration range of 4-4000 ng/mL, with linear correlation coefficient r equal to 0.9998. The limit of detection for the assay was 1.1 ng/mL. The within-day accuracy ranged from 94.8 to 101.6% and precision from 2.3 to 5.4%. The between-day accuracy ranged from 96.8 to 102.6% and precision from 4.0 to 5.3%. The absolute recovery was 95.4-101.2%. Urine samples were stable for at least 15 days if stored in the dark at -20 degrees C. This simple and accurate method allows the sensitive determination of ethacridine lactate in human urine. It was successfully applied to assess the urine level of ethacridine lactate in women received intra-amniotic injection.  相似文献   

10.
A high-performance liquid chromatography method with fluorescence detection (HPLC-FLD) for the determination of levofloxacin in human plasma is described. Neutralized with phosphate buffer (pH 7.0), the sample (0.1 mL) was extracted with dichlormethane (1 mL). After voltex-mixing and centrifuged at 3000g for 6 min at 4 degrees C, the upper aqueous layer was aspirated using a micro vacuum pump and the organic layer was directly transferred to a clean test tube without pipetting. The organic solvent was evaporated and the residues were reconstituted with the mobile phase. Levofloxacin and terazosin (internal standard, IS) were chromatographically separated on a C(18) column with a mobile phase containing phosphate buffer (pH 3.0, 10 mm), acetonitrile and triethylamine (76:24:0.076, v/v/v) at a flow rate of 1 mL/min. The analytes were detected using fluorescence detection at an excitation and emission wavelength of 295 and 440 nm, respectively. The linear range of the calibration curves was 0.0521-5.213 microg/mL for levofloxacin with a lower limit of quantitation (0.0521 microg/mL). The retention times of levofloxacin and terazosin were 2.5 and 3.1 min, respectively. Within- and between-run precision was less than 12 and 11%, respectively. Accuracy ranged from -6.3 to 4.5%. The recovery ranged from 86 to 89% at the concentrations of 0.0521, 0.5213 and 5.213 microg/mL. The present HPLC-FLD method is sensitive, efficient and reliable. The method described herein has been successfully used for the pharmacokinetic and bioequivalence studies of a levofloxacin formulation product after oral administration to healthy Chinese volunteers.  相似文献   

11.
Trimetazidine and internal standard [1-(2,4,5-trimethoxybenzyl)piperazine] were isolated from plasma by protein precipitation with trifluoroacetic acid. The neutralized supernatant was separated on a C(8) column with methanol-aqueous 0.11% triethylamine adjusted to pH 3.3 with formic acid (1:4, v/v) at a flow rate of 0.85 mL/min. The separation was achieved within 8 min and the column ef fluent was transferred into an ion trap analyzer via an atmospheric pressure chemical ionization interface. The mass analyzer was used in the selected reaction monitoring mode, to enhance detection selectivity. The method was fully validated with a quantitation limit for trimetazidine of 1.5 ng/mL. The method was successfully applied to assess bioequivalence of two immediate and two modified commercially available pharmaceutical formulations containing 20 and 35 mg of trimetazidine, respectively.  相似文献   

12.
A highly sensitive liquid chromatographic-tandem mass spectrometric method (LC-MS-MS) is developed to quantitate ranolazine in human plasma. The analyte and internal standard tramadol are extracted from plasma by liquid-liquid extraction using diethyl ether-dichloromethane (60:40 v/v), and separated on a Zorbax extend C(18) column using methanol-10mM ammonium acetate (60:40 v/v, pH 4.0) at a flow of 1.0 mL/min. Detection is carried out by multiple reaction monitoring on a QtrapTM LC-MS-MS system with an electrospray ionization interface. The assay is linear over the range 10-5000 ng/mL with a limit of quantitation of 10 ng/mL and a lower limit of detection (S/N > 3) of 1 ng/mL. Intra- and inter-day precision are < 3.1% and < 2.8%, respectively, and the accuracy is in the range 96.7-101.6%. The validated method is successfully used to analyze the drug in samples of human plasma for pharmacokinetic studies.  相似文献   

13.
An isocratic high-performance liquid chromatographic method with UV detection has been developed and validated for the quantitative determination of foscarnet in isoosmotic sodium chloride aqueous solution. The mobile phase consisted of mixture of methanol:water (30:70 v/v), containing 1 mm tetrahexylammonium hydrogen sulphate at pH 5.80. The analyte was separated on a reversed-phase C(18) column packed with 4 microm spherical particles of octadecylsilane. Hydrochlorothiazide was used as internal standard. UV detection at 232 nm allowed a quantification limit of 50 microg/mL. The assay was linear from 50 to 4000 microg/mL. The coefficient of variation was < or =2.52% for intra-assay precision and < or =3.49% for inter-assay precision. The deviation from the nominal value ranged from -0.57 to 0.47% for the same-day accuracy and from -0.75 to 3.06% for day-to-day accuracy.  相似文献   

14.
A selective and sensitive liquid chromatographic method was developed for the determination of fluoxetine (FLU) in plasma. FLU was isolated from plasma by liquid-liquid extraction. The chromatographic separation was performed on an analytical 250 x 3.9 mm id Novapak C18 column (4 microm particle size) with an isocratic mobile phase consisting of phosphate buffer-acetonitrile-methanol -triethylamine (58 + 30 + 10 + 2, v/v) adjusted to pH 7. Using UV detection at 226 nm, the detection limit for FLU in plasma was 3 ng/mL. No interferences were found with tricyclic antidepressant drugs, which allows this method to be used in clinical studies. The calibration curve was linear over the concentration range of 10-200 ng/mL. The average recovery was about 80% for plasma. The inter- and intraday assay coefficients of variation were <8%.  相似文献   

15.
A simple HPLC technique for determining mitragynine levels in serum was developed. The separation system consisted of a C18 column heated to 35 degrees C, a methanol-water (80:20, v/v) mobile phase, a flow rate of 0.8 mL/min and detection in the ultraviolet at 225 nm. Mitragynine, with a retention time of 10.09 min, was well resolved from any interferences in human serum and the internal standard peak. The calibration curve was linear from 0.1 to 10 microg/mL (r = 0.9995). Extraction of mitragy-nine from alkalinized serum using diethyl ether gave a high recovery (>or=85%). The intra- and inter-day precisions of the method were 4.29-5.88%RSD and 7.06-8.45%RSD, respectively. The accuracy ranged from -9.54 to +0.67%DEV. The limit of detection was 0.03 microg/mL and the lower limit of quantification was 0.1 microg/mL. Mitragynine in the stock solution was stable during 30 days of storage at 4 degrees C. This method was successfully applied to determine the pharmacokinetic characteristics of mitragynine levels in the serum of rats after it was administered orally.  相似文献   

16.
The present study describes the development and validation of a selective liquid chromatographic (LC) method for the analysis of tenofovir disoproxil fumarate (TDF) and its related substances. The gradient method uses a base deactivated C18 column (Hypersil BDS column; 25 cm×4.6 mm I.D.) maintained at a temperature of 30°C. The mobile phases consist of acetonitrile, tetrabutylammonium/phosphate buffer pH 6.0 and water: (A; 2:20:78 v/v/v) and (B; 65:20:15 v/v/v). The flow rate is 1.0 mL/min and UV detection is performed at 260 nm. Good separation of TDF and 21 impurities was achieved. A system suitability test (SST) to check the quality of separation is also specified. The developed method was further validated with respect to robustness, precision, sensitivity and linearity. The method is proved to be robust, precise, sensitive and linear between 0.1 μg/mL and 0.15 mg/mL. The limit of detection and limit of quantification are 0.03 and 0.1 μg/mL, respectively. The method was successfully applied to the quantification of related substances and assay of commercial TDF samples (bulk substances and tablets).  相似文献   

17.
A simple, sensitive, and selective stability indicating high performance liquid chromatographic method has been developed and validated for quantitative analysis of carprofen (CPF) in presence of its degradation products. All degradation products in acid hydrolysis and photolysis were separated, identified by mass spectroscopic method and probable structures were elucidated. The forced degradation studies were performed on a bulk sample of CPF by using various methods like 0.1 M hydrochloric acid, 0.1 M sodium hydroxide, 0.33% hydrogen peroxide (H(2)O), heating at 60°C and exposure to UV light at 254 nm. A 5 μm particle octa desyl silane (ODS) column (150 mm × 4.6 mm) was used with acetonitrile-ammonium acetate (100 mM, pH-6.7) 40:60 (v/v) as a mobile phase at flow rate of 1.2 mL/min. Column oven temperature was maintained at 30°C and quantitation was achieved at 239 nm on the basis of peak area. The linear range and correlation coefficient (r(2)) was found 0.5-60 μg/mL and 0.9999 respectively. The limit of detection (LOD) and limit of quantitation (LOQ) were obtained 0.066 μg/mL and 0.20 μg/mL respectively . The proposed method was found to be suitable and accurate for quantitative analysis, stability study and characterisation of degradation product of CPF.  相似文献   

18.
Development, validation and application of an HPLC assay for new antiviral nucleoside analogues AM365 and AM188 in isolated perfused rat liver perfusate and bile were performed. An analytical column (Phenosphere-NEXT, 250 x 4.6 mm, C(18), 4 microm, Phenomenex) was used in tandem with a guard column (4 x 3 mm, C(18), Phenomenex) and operated at 25 degrees C. The mobile phase [methanol:10 mmol/L sodium orthophosphate buffer (pH 7.0), 15:85, v/v] was pumped at 1 mL/min. The signal from a diode array detector was collected from 190 to 300 nm. The chromatogram was processed at 220 and 252 nm for AM365 and AM188, respectively. The HPLC method was validated by six intraday and seven interday runs. Standard curves were linear in the range 0.125-8.00 microg/mL for AM365 and AM188, and the lower limit of quantification for AM365 and AM188 was 0.125 microg/mL. Mean interday precision and accuracy of IPL perfusate quality control samples were within 8.8%, and mean intraday precision and accuracy were within 13.1%. The assay has been successfully used in the study of metabolism and disposition of AM365 in the isolated perfused rat liver.  相似文献   

19.
A simple HPLC method with ultraviolet detection has been developed and validated for the simultaneous determination of haplamine and its metabolites (trans/cis-3,4-dihydroxyhaplamine) in rat. A liquid-liquid extraction was used to extract the compounds from rat plasma. The analysis was performed on a C(18) Nucleosil Nautilus column. The mobile phase consisted of water (A) and a mixture of methanol and acetonitrile (85:15; v/v) (B) used in gradient mode (38-40% B for 10 min, 40-58% B for 49 min, 58-38% B for 1 min, and 38% for 5 min) pumped at 1 mL/min. The calibration curves showed good linearity with correlation coefficients greater than 0.999 for the analytes in the investigated concentration range. The lower limit of detection was 0.007, 0.008 and 0.009 microg/mL and the lower limit of quantification was 0.014, 0.017 and 0.018 microg/mL for haplamine, and trans/cis-3,4-dihydroxyhaplamine, respectively. The method was applied to a preliminary pharmacokinetic study in rats. This method proved to meet fully the standards required of experimental pharmacokinetic studies and should be used in further preclinical investigation.  相似文献   

20.
A high-performance liquid chromatographic method with UV detection has been developed for the determination of saikosaponin a in rat plasma. Saikosaponin a and internal standard jujuboside A were isolated from plasma samples by solid-phase extraction. The chromatographic separation was achieved on a reversed-phase C(18) column with the mobile phase of acetonitrile-water (35:65, v/v) at a flow rate of 1 mL/min and UV detection was set at 205 nm. The standard curve for saikosaponin a was linear over the concentration range 0.25-10 microg/mL and the limit of detection was 0.05 microg/mL. The absolute recovery was greater than 82%. The precision and accuracy ranged from 3.05 to 9.59% and 95.61 to 110.00%, respectively. The validated method was used to determine saikosaponin a in plasma samples in a pharmacokinetic study of saikosaponin a administered to Sprague-Dawley rats.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号