首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Zhong H  Yun D  Zhang C  Yang P  Fan H  He F 《Electrophoresis》2008,29(11):2372-2380
In this study, ampholyte-free liquid-phase IEF (LIEF) was combined with narrow pH range 2-DE and SDS-PAGE RP-HPLC for comprehensive analysis of mouse liver proteome. Because LIEF prefractionation was able to reduce the complexity of the sample and enhance the loading capacity of IEF strips, the number of visible protein spots on subsequent 2-DE gels was significantly increased. A total of 6271 protein spots were detected after integrating five narrow pH range 2-DE gels following LIEF prefractionation into a single virtual 2-DE gel. Furthermore, the pH 3-5 LIEF fraction and the unfractionated sample were separated by pH 3-6 2-DE and identified by MALDI-TOF/TOF MS, respectively. In parallel, the pH 3-5 LIEF fraction was also analyzed by SDS-PAGE RP-HPLC MS/MS. LIEF-2-DE and LIEF-HPLC could obviously improve the separation efficiency and the confidence of protein identification, which identified a higher number of low-abundance proteins and proteins with extreme physicochemical characteristics or post-translational modifications compared to conventional 2-DE method. Furthermore, there were 207 proteins newly identified in mouse liver in comparison with previously reported large-scale datasets. It was observed that the combination of LIEF-2-DE and LIEF-HPLC was effective in promoting MS-based liver proteome profiling and could be applied on similar complex tissue samples.  相似文献   

2.
The use of cup-loading for sample application has become widely used in two-dimensional electrophoresis (2-DE) for resolution of basic proteins, but no side-by-side quantitative study has been published which compares cup-loading with the alternative passive and active rehydration methods to fully promote one type of loading method over another. Replicate 2-D gels from each loading method were quantitatively evaluated for gel-to-gel reproducibility using IPG 6-11 strips and semipreparative protein loads (300 microg). Gels were stained with SYPRO Ruby and analyzed with PDQuest. An inexpensive home-made assembly for cup-loading was used with the Protean IEF Cell for separation of whole cell extracts from the archaeon, Sulfolobus solfataricus. Cup-loading was determined to be far superior for IPG 6-11 separations than active or passive rehydration methods. Cup-loading consistently produced the greatest number of detectable spots, the best spot matching efficiency (56%), lowest spot quantity variations (28% coefficient of variation, CV), and the best-looking gels qualitatively. The least satisfactory results were obtained with active rehydration, followed closely by passive rehydration in off-line tubes. Passive rehydration experiments, performed using an on-line isoelectric focusing (IEF) tray, produced comparable spot numbers to cup-loading (84%), with 55% of the spots having higher intensity but 10% more spot quantity variance than cup-loading.  相似文献   

3.
Cerebrospinal fluid (CSF) is in close proximity to the brain and changes in the protein composition of CSF may be indicative of altered brain protein expression in neurodegenerative disorders. Analysis of brain-specific proteins in CSF is complicated by the fact that most CSF proteins are derived from the plasma and tend to obscure less abundant proteins. By adopting a prefractionation step prior to two-dimensional gel electrophoresis (2-DE), less abundant proteins are enriched and can be detected in complex proteomes such as CSF. We have developed a method in which liquid-phase isoelectric focusing (IEF) is used to prefractionate individual CSF samples; selected IEF fractions are then analysed on SYPRO-Ruby-stained 2-D gels, with final protein identification by matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOFMS). To optimise the focusing of the protein spots on the 2-D gel, the ampholyte concentration in liquid-phase IEF was minimised and the focusing time in the first dimension was increased. When comparing 2-D gels from individual prefractionated and unfractionated CSF samples it is evident that individual protein spots are larger and contain more protein after prefractionation of CSF. Generally, more protein spots were also detected in the 2-D gels from prefractionated CSF compared with direct 2-DE separations of CSF. Several proteins, including cystatin C, IgM-kappa, hemopexin, acetyl-coenzyme A carboxylase-alpha, and alpha-1-acid glycoprotein, were identified in prefractionated CSF but not in unfractionated CSF. Low abundant forms of posttranslationally modified proteins, e.g. alpha-1-acid glycoprotein and alpha-2-HS glycoprotein, can be enriched, thus better resolved and detected on the 2-D gel. Liquid-phase IEF, as a prefractionation step prior to 2-DE, reduce sample complexity, facilitate detection of less abundant protein components, increases the protein loads and the protein amount in each gel spot for MALDI-MS analysis.  相似文献   

4.
We describe a miniaturized instrument capable of performing 2-DE. Our miniaturized device is able to perform IEF and polyacrylamide slab gel electrophoresis (PASGE) in the same unit. It consists of a compartment for a first-dimensional IEF gel, which is connected to a second-dimensional PASGE gel. The focused samples are automatically transferred from the IEF gel to the PASGE gel by electromigration. Our preliminary experiments show that the device is able to focus and separate a mixture of proteins in approximately 1 h, excluding the time required for the staining procedure. On average, the gel-to-gel retardation factor (Rf) variation was 6.2% (+/-0.9%) and pI variation was 2.5% (+/-0.6%). Separated protein spots were excised from stained gels, digested with trypsin, and further identified by MS, thus enabling direct proteomic analysis of the separated proteins.  相似文献   

5.
Raman B  Cheung A  Marten MR 《Electrophoresis》2002,23(14):2194-2202
While a variety of software packages are available for analyzing two-dimensional electrophoresis (2-DE) gel images, no comparisons between these packages have been published, making it difficult for end users to determine which package would best meet their needs. The goal here was to develop a set of tests to quantitatively evaluate and then compare two software packages, Melanie 3.0 and Z3, in three of the fundamental steps involved in 2-DE image analysis: (i) spot detection, (ii) gel matching, and (iii) spot quantitation. To test spot detection capability, automatically detected protein spots were compared to manually counted, "real" protein spots. Spot matching efficiency was determined by comparing distorted (both geometrically and nongeometrically) gel images with undistorted original images, and quantitation tests were performed on artificial gels with spots of varying Gaussian volumes. In spot detection tests, Z3 performed better than Melanie 3.0 and required minimal user intervention to detect approximately 89% of the actual protein spots and relatively few extraneous spots. Results from gel matching tests depended on the type of image distortion used. For geometric distortions, Z3 performed better than Melanie 3.0, matching 99% of the spots, even for extreme distortions. For nongeometrical distortions, both Z3 and Melanie 3.0 required user intervention and performed comparably, matching 95% of the spots. In spot quantitation tests, both Z3 and Melanie 3.0 predicted spot volumes relatively well for spot ratios less than 1:6. For higher ratios, Melanie 3.0 did much better. In summary, results suggest Z3 requires less user intervention than Melanie 3.0, thus simplifying differential comparison of 2-DE gel images. Melanie 3.0, however, offers many more optional tools for image editing, spot detection, data reporting and statistical analysis than Z3. All image files used for these tests and updated information on the software are available on the internet (http://www.umbc.edu/proteome), allowing similar testing of other 2-DE image analysis software packages.  相似文献   

6.
Experimental variability in 2-DE is well documented, but little attention has been paid to variability arising from postexperimental quantitative analyses using various 2-DE software packages. The performance of two 2-DE analysis software programs, Phoretix 2D Expression v2004 (Expression) and PDQuest 7.2 (PDQuest), was evaluated in this study. All available background subtraction and smoothing algorithms were tested using both data generated from one single 2-DE gel image, thus excluding experimental variance, and with authentic sets of replicate gels (n = 5). A slight shift of the image boundaries (the "cropping area") caused both programs to induce variance in protein spot quantification of otherwise identical gel images. The resulting variance for PDQuest (CV(mean) = 8%) was approximately twice that for Expression (CV(mean) = 4%). In authentic sets of replicate 2-DE gels (n = 5), the experimental variance confounded the software-induced variance to some extent. However, Expression still outperformed PDQuest, which exhibited software-induced variance as high as 25% of the total observed variance. Surprisingly, the complete omission of background subtraction algorithms resulted in the least amount of software-based variance. These data indicate that 2-DE gel analysis software constitutes a significant source of the variance observed in quantitative proteomics, and that the use of background subtraction algorithms can further increase the variance.  相似文献   

7.
Oh-Ishi M  Satoh M  Maeda T 《Electrophoresis》2000,21(9):1653-1669
A two-dimensional gel electrophoresis (2-DE) method that uses an agarose isoelectric focusing (IEF) gel in the first dimension (agarose 2-DE) was compared with an immobilized pH gradient 2-DE method (IPG-Dalt). The former method was shown to produce significant improvements in the 2-D electrophoretic separation of high molecular mass proteins larger than 150 kDa, up to 500 kDa, and to have a higher loading capacity, as much as 1.5 mg proteins in total for micropreparative runs. The extraction medium found best in this study for agarose 2-DE of mammal tissues was 6 M urea, 1 M thiourea, 0.5% 2-mercaptoethanol, protease inhibitor cocktail (Complete Mini EDTA-free), 1% Triton X-100 and 3% 3-[(3-cholamidopropyl)dimethylammonio]-1-propanesulfonate (CHAPS). Trichloroacetic acid (TCA) treatment of the agarose gel after IEF is to be carefully weighed beforehand, because some high molecular mass proteins were less likely to enter the second-dimensional polyacrylamide gel after TCA fixation, and proteins such as mouse skeletal muscle actin gave pseudospots in the agarose 2-DE patterns without TCA fixation. As a good compromise we suggest fixation of proteins in the agarose gel with TCA for one hour or less. The first-dimensional agarose IEF gel containing Pharmalyte as a carrier ampholyte was 180 mm in length and 2.5-4.8 mm in diameter. The gel diameter was shown to determine the loading capacity of the agarose 2-DE, and 1.5 mg liver proteins in total were successfully separated by the use of a 4.8 mm diameter agarose gel.  相似文献   

8.
Stastná M  Slais K 《Electrophoresis》2005,26(18):3586-3591
Two-dimensional gel isoelectric focusing (2-D gel IEF) is presented as the combination of the same separation method used consecutively in two directions of the same gel. In this new method, after completion of IEF process in the first dimension the gel was cut into the separate strips, each containing selected analytes together with the appropriate part of the original broad pH gradient, and the strips were rotated by 90 degrees (with regard to the first IEF) and left to diffuse overnight. After diffusion the strips were subjected to the second IEF. During the second IEF, the corresponding narrow part of pH gradient in each strip was restored again, however, now along the strip. The progress of the separation process can be monitored visually by using colored low-molecular-weight isoelectric point (pI) markers loaded into the gel simultaneously with proteins. The unique properties of IEF, focusing and resolution power were enhanced by using the same technique twice. Two forms of beta-lactoglobulin (pI values 5.14 and 5.31, respectively) non-separated in the first IEF were successfully separated in the second dimension at relatively low voltage (330 V) with the resolution power comparable to the high-resolution gels requiring the high voltage during the run and long separation time. Glucose oxidase loaded as diluted solution into ten positions across the gel was finally focused into a single band during 2-D gel IEF. Since the first and second IEF are carried out on the same gel, no losses and contamination of analyte occur. The suggested method can be used for separation/fractionation of complex biological mixtures, similarly as other multidimensional separation techniques applied in proteomics, and can be followed by further processing, e.g., mass spectrometry analysis. The focusing properties of IEF could be useful especially in separation of mixtures, where components are at low concentration levels.  相似文献   

9.
The isoforms distribution of the glycoprotein antithrombin III (ATIII) derived from human plasma was investigated by means of isoelectric focusing (IEF) in polyacrylamide gels with immobilized pH gradients (IPG) and two-dimensional gel electrophoresis (2-DE) as well as capillary electrophoretic methods. It turned out that the presence of high concentrations of chaotropics (urea, thiourea) and zwitterionic detergents (3-[(3-cholamidepropyl)dimethylammonio]-1-propanesulfonate (CHAPS)) was decisive for attaining good resolution of the protein isoforms. Resolution by IPG-IEF was obtained with excellent reproducibility and pI differences down to 0.01 pH units could be distinguished. ATIII-alpha and ATIII-beta-fractions preseparated by heparin affinity chromatography showed an analogous but shifted spot pattern consisting each of one major and three minor isoforms. The main isoforms of ATIII-alpha and ATIII-beta exhibit pI values of 5.18 and 5.32, respectively, both values determined in the presence of high concentrations of urea. The pI difference of 0.14 pH units correspond to the effect of two sialic acids absent in ATIII-beta. The formation and occurrence of ATIII dimers and trimers turned out to be dependent on the sample preparation. The results obtained by 2-DE were compared with those of capillary zone electrophoresis (CZE) and capillary IEF (CIEF). Quantitative analysis regarding the CZE separated isoforms of plasma derived ATIII yielded a content of about 70% ATIII-alpha main isoform and about 6.6% of ATIII-beta. The pI values of ATIII determined by CIEF with internal calibration were in fair agreement with the pI values of the main isoforms achieved with 2-DE.  相似文献   

10.
The human milk fat globule membrane protein composition is still largely unknown, although it counts for 2-4% of the total milk protein content and contains several important biologically active components. The aim of this work was to create a two-dimensional electrophoresis (2-DE) map of the human milk fat globule membrane proteins, both integral and membrane-associated, and to identify and characterize as many protein components as possible. A new protocol for the solubilization and extraction of the human milk fat globule membrane proteins with a double extraction procedure is presented, and the results compared with the extraction methods reported in the literature. The proteins were separated, in the first dimension, by isoelectric focusing (IEF) in the pH range 3-10 on strips of 13 cm length and, in the second dimension, by Sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) on 11.5% T homogeneous gels. A reproducible 2-DE map of integral and membrane-associated proteins was obtained and the first 23 spots, representing the major components, were identified by matrix assisted laser desorption/ionization-time of flight (MALDI-TOF) mass spectrometric analysis and/or by amino acid sequencing.  相似文献   

11.
Ruan Y  Wan M 《Electrophoresis》2007,28(18):3333-3340
The separation of integral and peripheral membrane proteins is still a challenge, although many achievements have been made in the 2-DE-based membrane proteomics. Using a human breast cancer cell line, MCF-7, we investigated the influences of Tris, reducing reagents, cup loading, and SDS on membrane protein solubilization and separation by 2-DE. The addition of Tris to the sample solution improved the solubilization of the membrane-enriched fraction, and the best-quality gel patterns were obtained at 20 mM Tris. Tributylphosphine (TBP), a reducing agent, was not optimum in the 2-DE process because it not only decreased the solubilization of hydrophobic proteins but also caused some proteins, such as hsp60, prohibitin, and actin, to be resolved to a string of spots. However, when combined with DTT, TBP could improve the resolution of 2-DE patterns. Cup loading significantly facilitated the entrance of membrane proteins into IPG strips and over 1000 protein spots with high resolution were visualized. Adopting this strategy, an ATP synthase alpha chain was resolved into two adjacent spots for the first time in 2-DE gel patterns through the adding DTT in the middle of the IEF. A high SDS concentration in the equilibration buffer enhanced the transfer and increased the staining intensity of 50% of the protein spots in the gels, but also resulted in losses of some spots.  相似文献   

12.
Despite its excellent resolving power, 2-DE is of limited use when analyzing cellular proteomes, especially in differential expression studies. Frequently, fewer than 2000 protein spots are detected on a single 2-D gel (a fraction of the total proteome) regardless of the gel platform, sample, or detection method used. This is due to the vast number of proteins expressed and their equally vast dynamic range. To exploit 2-DE unique ability as both an analytical and a preparative tool, the significant sample prefractionation is necessary. We have used solution isoelectric focusing (sIEF) via the ZOOM IEF Fractionator (Invitrogen) to generate sample fractions from complex bacterial lysates, followed by parallel 2-DE, using narrow-range IPG strips that bracket the sIEF fractions. The net result of this process is a significant enrichment of the bacterial proteome resolved on multiple 2-D gels. After prefractionation, we detected 5525 spots, an approximate 3.5-fold increase over the 1577 spots detected in an unfractionated gel. We concluded that sIEF is an effective means of prefractionation to increase depth of field and improve the analysis of low-abundance proteins.  相似文献   

13.
Due to their poor solubility during IEF membrane proteins cannot be separated and analyzed satisfactorily with classical 2-DE. A more efficient method for such hydrophobic proteins is the benzyldimethyl-n-hexadecylammonium chloride (16-BAC)/SDS-PAGE, but the corresponding protocol is intricate and time-consuming. We now developed an easy-to-handle electrophoresis method in connection with a novel device which enables reproducible separation of ionic solubilized membrane proteins using individually rehydrated plastic sheet gel strips. These strips are suitable for the first dimension in a 2-D 16-BAC/SDS system and can be handled easily; this is demonstrated by the separation of membrane proteins of human embryonic kidney (HEK293) cells.  相似文献   

14.
Zhou S  Mann CJ  Dunn MJ  Preedy VR  Emery PW 《Electrophoresis》2006,27(5-6):1147-1153
We report a method to quantify the specific radioactivity of proteins that have been separated by 2-DE. Gels are stained with SyproRuby, and protein spots are excised. The SyproRuby dye is extracted from each spot using DMSO, and the fluorescence is quantified automatically using a plate reader. The extracted gel piece is then dissolved in hydrogen peroxide and radioactivity is quantified by liquid scintillation counting. Gentle agitation with DMSO for 24 h was found to extract all the SyproRuby dye from gel fragments. The fluorescence of the extract was linearly related to the amount of BSA loaded onto a series of 1-D gels. When rat muscle samples were run on 2-DE gels, the fluorescence extracted from 54 protein spots showed a good correlation (r = 0.79, p < 0.001) with the corresponding spot intensity measured by conventional scanning and image analysis. DMSO extraction was found not to affect the amount of radioactive protein left in the gel. When a series of BSA solutions of known specific radioactivity were run on 2-DE gels, the specific radioactivity measured by the new method showed a good correlation (r = 0.98, p < 0.01, n = 5) with the specific radioactivity measured directly before loading. Reproducibility of the method was measured in a series of 2-DE gels containing proteins from the livers of rats and mice that had been injected with [35S]methionine. Variability tended to increase when the amount of radioactivity in the protein spot was low, but for samples containing at least 10 dpm above background the CV was around 30%, which is comparable to that obtained when measuring protein expression by conventional image analysis of SyproRuby-stained 2-DE gels. Similar results were obtained whether spots were excised manually or using a spot excision robot. This method offers a high-throughput, cost-effective and reliable method of quantifying the specific radioactivity of proteins from metabolic labelling experiments carried out in vivo, so long as sufficient quantities of radioactive tracer are used.  相似文献   

15.
Single proteins separated by 2-DE often show multiple spots spreading along the first dimension. In many cases, such charge trains are explained by isoform differences or by putative post-translational modifications including phosphorylation, glycosylation and others. We now report that individual spots of such charge trains on 2-D gels in fact often represent the same protein, but, apparently due to conformational changes, segregate to different isoelectric points. If MS analysis reveals protein identity, we therefore suggest integrating all individual spots within a charge train for quantification. Especially in quality control of pharmaceutical proteins, the integration of the spot groups of all active contents is preferable in order to obtain reproducible and reasonable quantitative results. However, most commercial software packages for gel analysis integrate the signals spot-wise. We provide an improved quantification tool for proteins with charge train groups. This calculation can be implemented using the MATLAB software and the self-developed "Correct Integration Software System" or the commercial software package Delta2D.  相似文献   

16.
With the growing importance of proteomics in biomedical and pharmaceutical sciences a need has emerged for computing tools that are capable of digitally visualizing and analyzing protein spot patterns within two-dimensional electrophoresis (2-DE) gel. Matching programs need to meet requirements such as interlaboratory comparison and the comparison of samples from different origins. For such research purposes, we have developed the CAROL system that implements new algorithms for spot detection and matching, which enable researchers to take a different approach to protein spot identification and comparison. The present short communication discusses how the system deals with uncertain geometric spot information that arises from streaks and complex spot regions and how this can be amplified for the matching procedure.  相似文献   

17.
Practical approaches to the use of multivariate data analysis of 2-DE protein patterns are demonstrated by three independent strategies for the image analysis and the multivariate analysis on the same set of 2-DE data. Four wheat varieties were selected on the basis of their baking quality. Two of the varieties were of strong baking quality and hard wheat kernel and two were of weak baking quality and soft kernel. Gliadins at different stages of grain development were analyzed by the application of multivariate data analysis on images of 2-DEs. Patterns related to the wheat varieties, harvest times and quality were detected on images of 2-DE protein patterns for all the three strategies. The use of the multivariate methods was evaluated in the alignment and matching procedures of 2-DE gels. All the three strategies were able to discriminate the samples according to quality, harvest time and variety, although different subsets of protein spots were selected. The explorative approach of using multivariate data analysis and variable selection in the analyses of 2-DEs seems to be promising as a fast, reliable and convenient way of screening and transforming many gel images into spot quantities.  相似文献   

18.
Manabe T  Jin Y 《Electrophoresis》2007,28(12):2065-2079
Previously, we have reported on the analysis of human plasma proteins on a nondenaturing micro-2-DE (mu2-DE) gel, using in-gel digestion followed by MALDI-MS and PMF [1]. Many of the spots on the mu2-DE gel showed apparent masses much larger than the calculated masses of their assigned polypeptides, suggesting noncovalent or covalent interactions between the polypeptides. In the present study, we aimed to further analyze the plasma protein spots on a nondenaturing mu2-DE gel, on which protein/polypeptide interactions have been suggested. The proteins in the spots were extracted under alkaline conditions and subjected to 3-D separation using SDS-PAGE in microslab gel format (muSDS gel) with or without the sample treatment of reduction-alkylation. The clear bands in each lane of the muSDS gels demonstrated the successful extraction of proteins from the relevant gel spot and visualized the relative contents of the polypeptides in the spot. Most of the bands were assigned by in-gel digestion followed by MALDI-MS and PMF (MASCOT/Swiss-Prot). The large discrepancy between the apparent mass value of a protein spot and the estimated mass values of the polypeptide bands on a nonreducing muSDS gel strongly suggested noncovalent polypeptide interactions. The differences in the polypeptide separation patterns on the muSDS gels, between with and without the treatment of reduction-alkylation, confirmed polypeptide disulfide bonding. The method employed here, aiming to integrate information on the proteins separated on nondenaturing 2-DE gels with that on the interactions between polypeptides, would help the comprehensive understanding of complex protein systems.  相似文献   

19.
The quantitative attributes of human leukocyte proteins detected by silver staining two-dimensional electrophoresis (2-DE) gels were studied by using computer-assisted data analysis. Experiments included (a) analysis of replicate patterns of the same sample, (b) analysis of different dilutions of the same sample, and (c) analysis of samples from different individuals. Over 200 proteins were observed to have coefficients of variation (CV) less than or equal to 15% when data from replicate patterns were analyzed. In contrast, 8 proteins had CV values of less than or equal to 15% when data from different samples were analyzed. The dilution experiment showed that a majority of the proteins detected with some consistency (i.e., observed in at least 80% of the patterns) have a linear relationship between the amount of protein loaded onto a 2-DE gel and the spot volume in the final 2-DE pattern. The slope of the curves and the deviation from linearity were found to be quite protein-specific. These results indicate that optimization of sample purity and minimization of staining protocol variables are required to limit the background quantitative variability between and within 2-DE runs to a level that will allow detection of quantitative changes indicative of biological responses.  相似文献   

20.
The goal of integrative top–down proteomics (i.e., two-dimensional gel electrophoresis [2DE] coupled with liquid chromatography and tandem mass spectrometry [LC/MS/MS]) is a routine analytical approach that fully addresses the breadth and depth of proteomes. To accomplish this, there should be no addition, removal, or modification to any constituent proteoforms. To address two-decade old claims of protein losses during front–end proteome resolution using 2DE, here we tested an alternate rehydration method for immobilized pH gradient strips prior to isoelectric focusing (IEF; i.e., faceup compared to facedown) and quantitatively assessed losses during the front–end of 2DE (rehydration and IEF). Using a well-established high-resolution, quantitative 2DE protocol, there were no detectable proteoform losses using the alternate faceup rehydration method. Although there is a <0.25% total loss of proteoforms during standard facedown rehydration, it is insignificant in terms of having any effect on overall proteome resolution (i.e., total spot count and total spot signal). This report is another milestone in integrative top–down proteomics, disproving long-held dogma in the field and confirming that quantitative front–end 2DE/LC/MS/MS is currently the only method to broadly and deeply analyze proteomes by resolving their constituent proteoforms.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号