首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
Room temperature ionic liquids (RTILs), 1‐n‐butyl‐3‐methylimidazolium tetrafluoroborate, [bmim]BF4, and multiwalled carbon nanotubes (MWCNTs) were used for improvement of a praseodymium carbon paste ion selective sensor response. [bmim]BF4 can be a better binder than mineral oils. MWCNTs have a good conductivity which helps the transduction of the signal in carbon paste electrode. The characteristics of these electrodes as potentiometric sensors were evaluated and compared with PVC membrane sensor. The results indicate that potentiometric sensor constructed with ionic liquid shows an increase in performance in terms of Nernstian slope, selectivity, response time, and response stability compared to Pr(III) PVC membrane sensor.  相似文献   

2.
In this paper, a survey has been undertaken to clarify the possible reasons for the electrocatalytic activity obtained by the presence of ionic liquid in carbon paste electrode (CPE). For this purpose, the effect of the addition of traces of ionic liquid to conventional CPE was investigated. Fe(CN)63?/4? was used as a probe and two ionic liquids, namely n‐octylpyridinum hexafluorophosphate and 1‐octyl‐3‐methylimidazolium hexaflourophosphate were tested for their electrocatalytic activity. The reasons for this electrocatalytic behavior were evaluated and it was found that different factors such as increase in the ionic conduction of the binder, decrease in the resistance of the modified electrode, increase in ion exchange properties of the electrode and the inherent catalytic activity of ionic liquids are responsible for the considerable improved electrochemical response obtained in the presence of traces of ionic liquid.  相似文献   

3.
A room temperature ionic liquid N‐butylpyridinium hexafluorophosphate (BPPF6) was used as a binder to make an ionic liquid modified carbon paste electrode (IL‐CPE), which showed good characteristics such as simple preparation procedure, fast electrochemical response and good conductivity. The electrochemical oxidation of ascorbic acid (AA) on the new IL‐CPE was carefully studied. The oxidation peak potential of AA on the IL‐CPE appeared at 109 mV (vs. SCE), which was about 338 mV decrease of the overpotential compared to that obtained on the traditional carbon paste electrode (CPE) and the oxidation peak current was increased for about four times. The electrochemical parameters of AA on the IL‐CPE were calculated with the charge transfer coefficient (α) and the electrode reaction rate constant (ks) as 0.87 and 0.800 s?1, respectively. Based on the relationship of the oxidation peak current and the concentration of AA a sensitive analytical method was established with cyclic voltammetry. The linear range for AA determination was in the range from 1.0×10?5 to 3.0×10?3 mol/L with the linear regression equation as Ip (μA)=?2.52–0.064C (μmol/L) (n=13, γ=0.9942) and the detection limit was calculated as 8.0×10?6 mol/L (3σ). The proposed method was free of the interferences of coexisting substances such as dopamine (DA) and amino acids etc., and successfully applied to the vitamin C tablets determination.  相似文献   

4.
An ionic liquid N‐hexylpyridinium hexafluorophosphate (HPPF6) modified carbon paste electrode was fabricated for the sensitive voltammetric determination of adenosine in this paper. Carbon ionic liquid electrode (CILE) was prepared by mixing graphite powder and HPPF6 together and the CILE was characterized by scanning electron microscopy (SEM) and electrochemical methods. The electrochemical behaviors of adenosine on the CILE were studied carefully. Compared with the traditional carbon paste electrode (CPE), a small negative shift of the oxidation peak potential appeared with greatly increase of the oxidation peak current, which indicated the presence of ionic liquid in the carbon paste not only as the binder but also as the modifier and promoter. Under the optimal conditions the oxidation peak current increased with the adenosine concentration in the range from 1.0×10?6 mol/L to 1.4×10?4 mol/L with the detection limit of 9.1×10?7 mol/L (S/N=3) by differential pulse voltammetry. The proposed method was applied to the human urine samples detection with satisfactory results.  相似文献   

5.
In this work 12 different ionic liquids (ILs) have been used added as co‐binders in the preparation of modified carbon paste electrodes (IL–CPEs) used for the voltammetric analysis of dopamine in Britton‐Robinson buffer. The ionic liquids studied were selected based on three main criteria: (1) increasing chain length of alkyl substituents (studying 1‐ethylimidazolium and ethyl, propyl, butyl, hexyl and decylmethylimidazolium bis(trifluoromethylsulfonyl)imide ionic liquids); (2) nature of the counter ion (dicyanamide, bis(trifluoromethylsulfonyl)imide and hexafluorophosphate) in 1‐butyl‐3‐methylimidazolium ionic liquids; and (3) cation ring structures (1‐butyl‐3‐methylimidazolium, 1‐butyl‐1‐methylpiperidinium, 1‐butyl‐1‐methylpyrrolidinium and 1‐butyl‐3‐methylpyridinium) in bis(trifluoromethylsulfonyl)imide or hexafluorophosphate (1‐butyl‐3‐methylimidazolium or 1‐butyl‐3‐methylpyridinium as cations) ionic liquids. The use of IL as co‐binders in IL–CPE results in a general enhancement of both the sensitivity and the reversibility of dopamine oxidation. In square wave voltammetry experiments, the peak current increased up to a 400 % when 1‐ethyl‐3‐methylimidazolium bis(trifluoromethylsulfonyl)imide was used as co‐binder, as compared to the response found with the unmodified CPE. Experimental data provide evidence that electrostatic and steric effects are the most important ones vis‐à‐vis these electrocatalytic effects on the anodic oxidation of dopamine on IL–CPE. The relative hydrophilicity of dicyanamide anions reduced the electrocatalytic effects of the corresponding ionic liquids, while the use of 1‐ethyl‐3‐methylimidazolium hexafluorophosphate or 1‐ethyl‐3‐methylimidazolium bis(trifluoromethylsulfonyl)imide (two relatively small and highly hydrophobic ionic liquids) as co‐binders in IL–CPE resulted in the highest electrocatalytic activity among all of the IL–CPE studied.  相似文献   

6.
A novel and effective potentiometric sensor for the rapid determination of Cd2+ based on carbon paste electrode consisting of the room temperature ionic liquid 1‐butyl‐3‐methylimidazolium hexafluorophosphate, multiwalled carbon nanotubes, silica nanoparticles and ionophore was constructed. The prepared composite has a low potential drift, high selectivity and fast response time, which leads to a more stable potential signal. A linear dynamic range of 4.50×10?9–1.00×10?1 mol L?1 with a detection limit of 2.00×10?9 mol L?1 was obtained. The modified electrode was successfully applied to the accurate determination of trace amounts of Cd2+ in environmental and biological samples.  相似文献   

7.
This paper describes the development of screen-printed (SPE) and carbon paste (CPE) sensors for the rapid and sensitive quantification of naphazoline hydrochloride (NPZ) in pharmaceutical formulations. This work compares the electroactivity of conventional carbon paste and screen-printed carbon paste electrodes towards potentiometric titration of NPZ. The repeatability and accuracy of measurements performed in the analysis of these pharmaceutical matrices using new screen printed sensors were evaluated. The influence of the electrode composition, conditioning time of the electrode and pH of the test solution, on the electrode performance were investigated. The drug electrode showed Nernstain responses in the concentration range from 1 × 10(-6) to 1 × 10(-2) mol L(-1) with slopes of 57.5 ± 1.3 and 55.9 ± 1.6 mV per decade for SPE and CPE, respectively, and was found to be very precise and usable within the pH range 3-8. These sensors exhibited a fast response time (about 3 s for both SPE and CPE, respectively), a low detection limit (3.5 × 10(-6) and 1.5 × 10(-6) M for SPE and CPE, respectively), a long lifetime (3 and 2 months for SPE and CPE, respectively) and good stability. The selectivity of the electrode toward a large number of inorganic cations, sugars and amino acids was tested. It was applied to potentiometric determination of NPZ in pure state and pharmaceutical preparation under batch conditions. The percentage recovery values for the assay of NPZ in tablets (relative standard deviations ≤0.3% for n = 4) were compared well with those obtained by the official method.  相似文献   

8.
Direct electrochemical reduction of p-nitrophenol(PNP)was investigated on a room temperature ionic liquid N-butylpyridinium hexafluorophosphate(BPPF6)modified carbon paste electrode(CILE).The cathodic peak potential was positively shifted and the peak currents were increased compared to that obtained on traditional carbon paste electrode(CPE).The results indicated that the presence of ionic liquid BPPF6 on the electrode surface showed excellent catalytic ability to the electrochemical reduction of PNP.The electrochemical behaviors of PNP on the CILE were investigated by cyclic voltammetry and the conditions such as the scan rate,the buffer pH,the substrate concentration were optimized.The electrochemical parameters were further calculated with the results of the electron transfer number(n),the charge-transfer coefficient(α)and the surface concentration(ΓΥ)as 1.76,0.37 and 2.47×10-9 mol/cm2,respectively,for the selected reducfive peak.The results indicated that PNP showed all irreversible adsorption-controlled electrode process on the CILE.  相似文献   

9.
The ferrocene/NaY zeolite composites (Fc/NaY) are introduced on the surface of a glassy carbon electrode together with the hydrophobic ionic liquid 1‐butyl‐3‐methylimidazolium hexafluorophosphate (BMIMPF6). The modified electrode thus constructed exhibits a pair of reversible redox peaks corresponding to ferrocene. Additionally the peak separation remains almost constant (58–75 mV) and the value of the ratio ipa/ipc is close to 1 for scan rates in the range from 10 to 1000 mV s?1. The effects of the scan rate, aqueous supporting electrolytes, hydrophobic ionic liquid and the contents of ferrocene encapsulated by electrochemistry are investigated. The extrazeolite electron transfer process is discussed. Furthermore, the Fc/NaY/IL‐modified electrode shows good mediation towards oxidation of ascorbic acid, dopamine, hydroquinone, and catechol.  相似文献   

10.
A novel pH sensing membrane was developed that consists of the ionic liquid n-cetylpyridinium hexafluorophosphate (CPFP), poly(vinyl chloride), and quinhydrone. The membrane is stable and flexible and can be easily deposited on the electrode. Electrochemical impedance spectroscopy was used to study the interfacial charge transfer of this membrane. Compared to a traditional plasticizer-based membrane electrode, the new electrode possesses excellent potentiometric characteristics for monitoring pH, such as a response time of less than 10 s, high sensitivity, stability, and reproducibility. The response is almost Nernstian, with a slope of ?57.5?±?0.2 mV pH?1 in the pH range from 2 to 9.5. The new electrode was used for direct monitoring of pH in real food samples.
Figure
A novel pH sensing membrane consisted of ionic liquid n-cetylpyridinium hexafluorophosphate, poly(vinyl chloride) and quinhydrone was developed. This membrane was stable and flexible, which could be easily deposited onto the electrode surface. Electrochemical impedance spectroscopy study shows that the ionic liquid-based membrane possesses fast charge transfer. Compared to the traditional plasticizer-based membrane electrode, the ionic liquid-based membrane electrode possessed very excellent potentiometric characteristics for pH monitoring. The pH sensor exhibited an almost Nernstian response with the slope of -57.5 mV pH-1 in the pH range from 2 to 9.5. Furthermore, the developed electrode was successfully applied to measure pH in the packaged beverages. Using ionic liquid as a novel plasticizer for preparation of polymer-based pH sensing membrane with excellent potentiometric performance  相似文献   

11.
In this paper two kinds of ionic liquids (ILs) were used for the construction of a myoglobin (Mb) electrochemical biosensor. Firstly a hydrophilic ionic liquid of 1‐ethyl‐3‐methylimidazolium tetrafluoroborate (EMIMBF4) was used as binder to prepare a carbon ionic liquid electrode (CILE), then a Nafion and hydrophobic ionic liquid of 1‐butyl‐3‐methylimidazolium hexafluorophosphate (BMIMPF6) composite film was applied on the surface of the CILE. The direct electrochemistry of Mb in the Nafion‐BMIMPF6/CILE was achieved with the cathodic and anodic peak potentials located at ?0.345 V and ?0.213 V (vs. SCE). The formal potential (E°′) was located at ?0.279 V, which was the characteristic of Mb FeIII/FeII redox couples. The electrochemical behaviors of Mb in the Nafion‐ionic liquid composite film modified CILE were carefully investigated. The Mb modified electrode showed good electrocatalytic behaviors to the reduction of trichloroacetic acid (TCA) and NaNO2. Based on the Nafion‐BMIMPF6/Mb/CILE, a new third generation reagentless biosensor was constructed.  相似文献   

12.
《Electroanalysis》2006,18(16):1598-1604
Four Schiff base complexes of different metal ions, M=Cr(III), Mn(III), Fe(III), and Co(III), were studied to characterize their ability as sulfate ion carriers in carbon paste electrode (CPE). The modified CPE electrode with Schiff base complex of Cr(III), N,N′‐ethylenebis(5‐hydroxysalicylideneiminato) chromium(III) Chloride, showed good response characteristics to SO42? ion. The proposed electrode exhibits a Nernstian slope of 28.9±0.4 mV per decade for SO42? ion over a wide concentration range from 1.5×10?6?4.8×10?2 M, with a detection limit of 9.0×10?7 M. The CPE electrode manifested advantages of relatively fast response time, suitable reproducibility and life time and, most important, good potentiometric selectivity relative to a wide variety of other common inorganic anions. The potentiometric response of the electrode is independent of the pH of the test solution in the pH range 4.0–9.0. The proposed electrode was used as an indicator electrode in potentiometric titration of sulfate with Ba2+ ion, the determination of zinc in zinc sulfate tablet and also determination of sulfate content of a mineral water sample.  相似文献   

13.
Direct electrochemical reduction ofp-nitrophenol (PNP) was investigated on a room temperature ionic liquid N-butylpyridinium hexafluorophosphate (BPPF6) modified carbon paste electrode (CILE). The cathodic peak potential was positively shifted and the peak currents were increased compared to that obtained on traditional carbon paste electrode (CPE). The results indicated that the presence of ionic liquid BPPF6 on the electrode surface showed excellent catalytic ability to the electrochemical reduction of PNP. The electrochemical behaviors of PNP on the CILE were investigated by cyclic voltammetry and the conditions such as the scan rate, the buffer pH, the substrate concentration were optimized. The electrochemical parameters were further calculated with the results of the electron transfer number (n), the charge-transfer coefficient (α) and the surface concentration (Гr) as 1.76, 0.37 and 2.47 × 10^-9 mol/cm^2, respectively, for the selected reductive peak. The results indicated that PNP showed an irreversible adsorption-controlled electrode process on the CILE.  相似文献   

14.
《Electroanalysis》2017,29(8):1854-1859
A carbon paste electrode modified with 1‐butyl‐3‐methylimidazolium hexafluorophosphate ionic liquid (BMIPF6) and CuO nanoparticles (CuO/NPs) (CPE/BMIPF6/CuO/NPs) was fabricated and used for square wave voltammetric analysis of levodopa in the presence of vitamin B6. The elemental analysis, SEM and XRD methods were used for characterization of synthesized CuO nanoparticle. CPE/BMIPF6/CuO/NPs exhibited high electrical conductivity toward the electro‐oxidation of levodopa at a pH=7.0 as best experimental condition. Using CPE/BMIPF6/CuO/NPs the levodopa and vitamin B6 peaks are separated and oxidized at potentials of 0.565 V and 0.835 V, respectively; hence levodopa can be detected in the presence of vitamin B6. The electrochemical response shows a linear relationship from concentration of levodopa and vitamin B6 in the ranges of 0.06‐1000 μM and 0.1‐700.0 μM, respectively. Finally, CPE/BMIPF6/CuO/NPs were applied as high performance tool for determination of levodopa and vitamin B6 in real samples.  相似文献   

15.
The electrochemical oxidation of levodopa on the surface of a carbon paste electrode modified with graphene nanosheets, 1‐(4‐bromobenzyl)‐4‐ferrocenyl‐1H‐[1,2,3]‐triazole (1,4‐BBFT) and hydrophilic ionic liquid (n‐hexyl‐3‐methylimidazolium hexafluoro phosphate) as a binder is studied. It has been found that the oxidation of levodopa at the surface of a modified electrode occurs at a potential of about 210 mV less positive than that of an unmodified carbon paste electrode (CPE). The prepared modified electrode exhibits a very good resolution of the voltammetric peaks of levodopa and cabergoline. The electrode has been applied successfully for the determination of levodopa and cabergoline in some real samples.  相似文献   

16.
Electroanalysis of benazepril HCl was successful using a carbon paste electrode modified with an ionic liquid crystal ( 1‐butyl‐1‐methylpiperidinium hexafluorophosphate) in presence of sodium dodecyl sulfate. The electrode performance was compared to ionic liquids (1‐n‐hexyl‐3‐methyl imidazolium tetrafluoroborate and 1‐butyl‐4‐methyl pyridinium tetrafluoroborate). Electrochemical determination of benazepril HCl was in the linear dynamic range of 8.89×10?7 to 1.77×10?5 mol L?1 (correlation coefficient 0.999) and LOD 7.17×10?9 mol L?1. benazepril HCl was determined using this sensor in presence of urine metabolites such as uric acid, ascorbic acid. Binary mixtures of dopamine/benazepril and amlodipine/benazepril were also determined successfully.  相似文献   

17.
A new hemoglobin (Hb) and room temperature ionic liquid modified carbon paste electrode was constructed by mixing Hb with 1‐butyl‐3‐methylimidazolium hexafluorophosphate (BMIMPF6) and graphite powder together. The Hb modified carbon ionic liquid electrode (Hb‐CILE) was further characterized by FT‐IR spectra, scanning electron microscopy (SEM) and electrochemical impedance spectroscopy (EIS). Hb in the carbon ionic liquid electrode remained its natural structure and showed good direct electrochemical behaviors. A pair of well‐defined quasireversible redox peaks appeared with the apparent standard potential (E′) as ?0.334 (vs. SCE) in pH 7.0 phosphate buffer solution (PBS). The electrochemical parameters such as the electron transfer number (n), the electron transfer coefficient (α) and the heterogeneous electron transfer kinetic constant (ks) of the electrode reaction were calculated with the results as 1.2, 0.465 and 0.434 s?1, respectively. The fabricated Hb‐CILE exhibited excellent electrocatalytic activity to the reduction of H2O2. The calibration range for H2O2 quantitation was between 8.0×10?6 mol/L and 2.8×10?4 mol/L with the linear regression equation as Iss (μA)=0.12 C (μmol/L)+0.73 (n=18, γ=0.997) and the detection limit as 1.0×10?6 mol/L (3σ). The apparent Michaelis–Menten constant (KMapp) of Hb in the modified electrode was estimated to be 1.103 mmol/L. The surface of this electrochemical sensor can be renewed by a simple polishing step and showed good reproducibility.  相似文献   

18.
用疏水性离子液体1-丁基-3-甲基咪唑六氟磷酸([BMIM]PF6)作粘合剂制备了离子液体修饰碳糊电极(IL/CPE)。采用循环伏安法(CV)研究了维生素E(vitamin E,VE)的氧化产物生育酚红在IL/CPE和未修饰碳糊电极(CPE)上的电化学行为,结果表明生育酚红在IL/CPE上氧化过程更易于进行,峰电流响应ip也明显增加,表明IL/CPE对生育酚红的氧化还原反应具有良好的电催化作用。同时测定了电极过程的动力学参数:电荷转移系数α=0.8746,扩散系数D=1.65×10-3cm2/s,电极反应速率常数kf=6.64×10-2cm/s。采用方波伏安法(SWV)发现生育酚红氧化峰电流与其浓度在1.53×10-4mol/L~8.39×10-7mol/L范围内呈线性关系,检出限为1.58×10-8mol/L。该法可用于VE实际样品的分析测定。  相似文献   

19.
A three‐factor mixture design and response surface methodology were employed to find the optimal weight ratio of graphite powder, n‐dodecylpyridinium hexafluorophosphate and paraffin for the fabrication of a copper hexacyanoferrate modified carbon ionic liquid paste electrode (CuHCFe‐CILPE). The fabricated sensor showed electrocatalytic activity towards oxidation and reduction of hydrogen peroxide. It also was observed that the electrocatalytic activity for hydrogen peroxide oxidation was much higher than the electrocatalytic activity for hydrogen peroxide reduction. Glucose oxidase was then successfully immobilized on the surface of the proposed sensor to examine the possibility of using CuHCFe‐CILPE for the biosensor fabrication.  相似文献   

20.
A new potentiometric sensor for the rapid determination of Hg2+ based on modified carbon paste electrode consisting of room temperature ionic liquid, 1-Butyl-3-methylimidazolium hexafluorophosphate (BMIM-PF6), multi-walled carbon nanotubes (MWCNTs), alumina nanoparticles and a synthetic macrocyclic diamide ‘7,10,13-triaza-1-thia-4,16-dioxa-6,14-dioxo-2,3;17,18-dinaphtho-cyclooctadecane’ as an efficient ionophore was constructed. Prepared composite is an ideal paste because it has low drift of potential, high selectivity and fast response time (10 s), which leads to a more stable potential signal. The morphology and properties of electrodes surface were characterised by scanning electron microscopy (SEM) and electrochemical impedance spectroscopy. A linear dynamic range of 2.01–2.01 × 107 µg L?1 with detection limit of 1.40 µg L?1 Hg2+ was obtained at pH range of 2.5 to 4.5. The prepared modified electrode shows several advantages such as simple preparation method, high stability of the composite paste, high sensitivity, long-term life time (at least 13 weeks) and remarkable potentiometric reproducibility. The modified electrode was successfully applied for the accurate determination of trace amounts of Hg 2+ in environmental samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号