首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Several triazine pesticides, such as atrazine, are much more soluble in several organic solvents, such as chloroform, than in water. Our recent research was aimed at analyzing this class of pesticides using tyrosinase OPEE (organic phase enzyme electrodes), exploiting their inhibiting action on the tyrosinase enzyme when operating in water-saturated chloroform medium. In this work we studied the response of a tyrosinase inhibition enzyme sensor to several triazinic (simazine, propazine, terbuthylazine) and benzotriazinic (azinphos-ethyl and azinphos-methyl) pesticides (LOD=0.5×10−9 mol l−1). Recovery trials were also performed in vegetal matrixes (corn, barley, lentils). Lastly, the effect of the solvent (chloroform or water) on the inhibition process was investigated via Hill’s equation and the diffusion of analyte from the solvent to the enzyme membrane.  相似文献   

2.
A tyrosinase (Tyr) screen-printed biosensor based on the electroreduction of enzymatically generated quinoid products was electrochemically characterized and optimized for determination of carbamates and organophosphorus pesticides. A composite electrode prepared by screen-printing a cobalt (II) phthalocyanine (CoPc) modified cellulose-graphite composite on a polycarbonate support was employed as electrochemical transducer. The Tyr biosensor was prepared by immobilization of enzyme on the composite electrode surface by cross-linking with glutaraldehyde and bovine serum albumin. Parameters affecting the biosensor response such as response time, enzyme loading, concentration and pH of the buffer solution were optimized utilizing catechol as substrate. The maximum response for o-quinone enzymatically generated was obtained after 2 min of reaction. A good reproducibility and high operational stability were found for Tyr biosensor (60 units) at 50 mM phosphate buffer, pH 6.50. Under these conditions, the useful lifetime of biosensor was 10 days. After 15 days, the biosensor could be used with 20% of the initial value. Inhibition studies on the o-quinone steady-state current (at −0.20 V versus Ag/AgCl) were performed to investigate the inhibition kinetics of the pesticides in the enzymatic activity of mushroom tyrosinase. The results shown that the methyl parathion and carbofuran can lead to competitive inhibition process of the enzyme, while diazinon and carbaryl act as mixed inhibitors. Linear relationships were found for methyl parathion (6-100 ppb), diazinon (19-50 ppb), carbofuran (5-90 ppb) and carbaryl (10-50 ppb). Analysis of natural river water samples spiked with 30 ppb of each pesticide showed recoveries between 92.50% and 98.50% and relative standard deviations of 2%.  相似文献   

3.
The determination of diuron, atrazine, desisopropylatrazine (DIA) and desethylatrazine (DEA) were investigated using conductometric tyrosinase biosensor. Tyrosinase was immobilised on the biosensor sensitive part by allowing it to mix with bovine serum albumin (BSA) and then cross-linking in saturated glutaraldehyde (GA) vapour for 30 min. The determination of pollutants in a solution was performed by comparison of the output signal (i.e percentage of the enzymatic activity) of the biosensor before and after contact with pollutants. The measurement of the enzymatic activity was performed using 4-chlorophenol, phenol and catechol substrates and response times ranging from 1 to 5 min were observed. A 4-chlorophenol substrate was used to detect pesticides. A 30 min contact time of the biosensor in the pollutant solution was used. Under the experimental conditions employed, detection limits for diuron and atrazine were about 1 ppb and dynamic range of 2.3-2330 and 2.15-2150 ppb were obtained for diuron and atrazine, respectively. A relative standard deviation (n=3) of the output signal was estimated to be 5% and a slight drift of 1.5 μS h−1 was observed. The 90% of the enzyme activity was still maintained after 23 days of storage in a buffer solution at 4 °C.  相似文献   

4.
Védrine C  Fabiano S  Tran-Minh C 《Talanta》2003,59(3):535-544
An amperometric enzyme sensor using tyrosinase, also called polyphenol oxidase (PPO), was constructed for determination of phenolic compounds and herbicides. The enzyme was entrapped in a conducting polymer, poly 3,4-ethylenedioxythiophene (PEDT), electrochemically generated on a glassy carbon electrode. Several experimental parameters in the electropolymerisation process and working conditions were determined to optimise biosensor performances. Mono-phenol and di-phenol were tested in oxygenated solutions, by amperometric measurements at −200 mV (vs. SCE) in a batch system. The limit of detection of these molecules ranges from 5 to 500 nM. Detection of herbicides was obtained from the inhibition of tyrosinase electrode responses. The limit of detection for atrazine and diuron was 1 and 0.5 mg l−1 respectively. These data suggest that PEDT film is a promising PPO immobilisation method.  相似文献   

5.
Amperometric screen-printed biosensor arrays for detection of pesticides (organophosphates and carbamates) and phenols have been developed. Cholinesterases (AChE and BChE), tyrosinase (TYR), peroxidases (SBP, soybean and HRP, horseradish) and cellobiose dehydrogenase (CDH) were combined on the same array consisting of one Ag/AgCl reference electrode surrounded by eight radially distributed working electrodes of either carbon or platinum. Mainly cross-linking with glutaraldehyde was employed for enzyme immobilisation. The substrates for the enzymes were acetylthiocholine for cholinesterases (ChEs), cellobiose for CDH and hydrogen peroxide for peroxidases. Hydrogen peroxide was generated in the presence of glucose by co-immobilised glucose oxidase (GOx). All measurements were performed in an electrochemical steady state system specially constructed for eight channel screen-printed electrode arrays. The achieved relative standard deviation values calculated for different enzyme substrates (10 measurements) were typically below 7% and one assay was completed within less than 10 min. The detection limits for pesticides and phenols were in the nanomolar and micromolar ranges, respectively. The developed biosensor array was evaluated on wastewater samples. To simplify interpretation of results, the measured data were treated with multivariate analysis-principal component analysis (PCA).  相似文献   

6.
Chronoamperometric assays based on tyrosinase and glucose oxidase (GOx) inactivation have been developed for the monitoring of Cr(III) and Cr(VI). Tyrosinase was immobilized by crosslinking on screen-printed carbon electrodes (SPCEs) containing tetrathiafulvalene (TTF) as electron transfer mediator. The tyrosinase/SPCTTFE response to pyrocatechol is inhibited by Cr(III). This process, that is not affected by Cr(VI), allows the determination of Cr(III) with a capability of detection of 2.0 ± 0.2 μM and a reproducibility of 5.5%. GOx modified screen-printed carbon platinised electrodes (SPCPtEs) were developed for the selective determination of Cr(VI) using ferricyanide as redox mediator. The biosensor was able to discriminate two different oxidation states of chromium being able to reject Cr(III) and to detect the toxic species Cr(VI). Chronoamperometric response of the biosensor towards glucose decreases with the presence of Cr(VI), with a capability of detection of 90.5 ± 7.6 nM and a reproducibility of 6.2%. A bipotentiostatic chronoamperometric biosensor was finally developed using a tyrosinase/SPCTTFE and a GOx/SPCPtE connected in array mode for the simultaneous determination of Cr(III) and Cr(VI) in spiked tap water and in waste water from a tannery factory samples.  相似文献   

7.
Shi H  Yang Y  Huang J  Zhao Z  Xu X  Anzai J  Osa T  Chen Q 《Talanta》2006,70(4):852-858
An amperometric choline biosensor was developed by immobilizing choline oxidase (ChOx) in a layer-by-layer (LBL) multilayer film on a platinum (Pt) electrode modified with Prussian blue (PB). 6-O-Ethoxytrimethylammoniochitosan chloride (EACC) was used to prepare the ChOx LBL films. The choline biosensor was used at 0.0 V versus Ag/AgCl to detect choline and exhibited good characteristics such as relative low detection limit (5 × 10−7 M), short response time (within 10 s), high sensitivity (88.6 μA mM−1 cm−2) and a good selectivity. The results were explained based on the ultrathin nature of the LBL films and the low operating potential that could be due to the efficient catalytic reduction of H2O2 by PB. In addition, the effects of pH, temperature and applied potential on the amperometric response of choline biosensor were evaluated. The apparent Michaelis-Menten constant was found to be (0.083 ± 0.001) ×10−3 M. The biosensor showed excellent long-term storage stability, which originates from a strong adsorption of ChOx in the EACC multilayer film. When the present choline biosensor was applied to the analysis of phosphatidylcholine in serum samples, the measurement values agreed satisfactorily with those by a hospital method.  相似文献   

8.
In this research, the graphene with excellent dispersity is prepared successfully by introducing gold nanoparticle to separate the individual sheets. Various techniques are adopted to characterize the prepared graphene and graphene-gold nanoparticle composite materials. This fabricated new composite material is used as the support material to construct a novel tyrosinase based biosensor for detection of bisphenol A (BPA). The electrochemical performances of the proposed new enzyme biosensor were investigated by differential pulse voltammetry (DPV) method. The proposed biosensor exhibited excellent performance for BPA determination with a wide linear range (2.5 × 10−3–3.0 μM), a highly reproducible response (RSD of 2.7%), low interferences and long-term stability. And more importantly, the calculated detection limit of the proposed biosensor was as low as 1 nM. Compared with other detection methods, this graphene-gold nanoparticle composite based tyrosinase biosensor is proved to be a promising and reliable tool for rapid detection of BPA for on-site analysis of emergency BPA related pollution affairs.  相似文献   

9.
An amperometric nicotine inhibition biosensor has been substantially simplified and used for determination of nicotine in tobacco sample. Besides the use of single enzyme choline oxidase to replace bienzyme, the use of 1,4-benzoquinone as an electron mediator makes it possible to avoid the use of oxygen or hydrogen peroxide sensor as the internal transducer. Choline oxidase was immobilized on the carbon paste electrode through cross-linking with bovine serum albumin (BSA) by glutaraldehyde. In the presence of choline oxidase and its endogenous cofactor flavin-ademine dinneleotide (FAD), choline was oxidized into betaine while FAD was reduced to FADH2 which subsequently reduced 1,4-benzoquinone into hydroquinone. The later was finally oxidized at a relatively low potential of +450 mV versus saturated calomel electrode (SCE). Nicotine inhibits the activity of enzyme with an effect of decreasing of oxidation current. The experimental conditions were optimized. The electrode has a linear response to choline within 1.25×10−4 to 1.25×10−3 mol l−1. The nicotine measurements were carried out in 0.067 mol l−1phosphate buffer of pH 7.4 at an applied potential of 450 mV versus SCE. The electrode provided a linear response to nicotine over a concentration range of 2.0×10−5 to 9.2×10−4 mol l−1 with a detection limit of 1.0×10−5 mol l−1. The system was applied to the determination of nicotine in tobacco samples.  相似文献   

10.
We have developed a quartz crystal microbalance (QCM) biosensor for the determination of organophosphorus and carbamate pesticides. A change in resonant frequency is observed as a result of mass adsorption, and we have used this as the basis for sensor development. Specifically, we have used a two-enzyme system (acetylcholine-esterase and choline oxidase) which converts acetylcholine to betaine producing hydrogen peroxide as a by-product. In a third enzyme reaction (peroxidase), the peroxide is able to oxidise benzidines (3,3′-diaminobenzidine) into an insoluble product that precipitates out and can adsorb to surfaces. Non-ionic surfactants have been used for the first time to enhance the surface deposition of suspended precipitate, thereby improving sensor sensitivity. Pesticides are known to inhibit esterase activity (thereby reducing the amount of QCM-detectable precipitate produced). We have shown that the QCM-enzyme sensor system can be used to determine carbaryl and dichlorvos down to 1 ppm.  相似文献   

11.
《Analytical letters》2012,45(7):1106-1127
Abstract

In recent years several inhibition biosensors have been proposed for the analysis of aqueous solutions of phytodrugs. We recently built an inhibition OPEE (organic phase enzyme electrode) based on the inhibition of tyrosinase for the analysis of triazine, carbamate, and organophosphate pesticides operating in water-saturated chloroform. It was possible to determine the concentration of these pesticides contained in lipophilic or aqueous samples by relating it to the inhibiting action measured directly in water, or in water-saturated chloroform, after using the same solvent to extract the pesticides themselves.

In the present investigation, attention was focused above all on two points of particular interest: on the study of potential interferents, i.e., of other inhibitors of the tyrosinase enzyme consisting above all, when operating in aqueous solution, of different heavy metal ions or several carboxylic acids, such as cinnamic, sorbic, or benzoic acids, which can apparently interfere in inhibition analysis of pesticides in aqueous matrixes; in the second place, on a detailed comparison of the results of the analysis of triazine, organophosphate, and carbamate pesticides in the presence of the above-mentioned interferents operating both in aqueous solution and in water-saturated chloroform.  相似文献   

12.
A new biosensor for detection of phenols, based on tyrosinase immobilization with alumina sol-gel on Sonogel-Carbon transducer, has been developed. The electrode was prepared using high energy ultrasounds directly applied to the precursors. The alumina sol-gel provided a microenvironment for retaining the native structure and activity of the entrapped enzyme and a very low mass transport barrier to the enzyme substrates. Phenols are oxidized by tyrosinase biosensor to form a detectable product, which was determined at −300 mV vs. Ag/AgCl reference electrode. For phenol, the sensor exhibited a fast response which resulted from the porous structure and high enzyme loading of the sol-gel matrix. The linear range was from 5 × 10−7 M to 3 × 10−5 M, with a detection limit of 3 × 10−7 M. The stability of the biosensor was also evaluated.  相似文献   

13.
Developing a biosensor which is capable of simultaneously monitoring l-Dopa levels in multiple samples besides requiring small reaction volume is of great value. The present study describes the detection of l-Dopa using tyrosinase enzyme extracted from Amorphophallus campanulatus and immobilized on the surface of the microplate wells. Among the different approaches used for immobilizing tyrosinase onto the microplate wells, glutaraldehyde treatment was found to be most effective. Besides enzyme activity, ESEM–EDS (environmental scanning electron microscope–energy dispersive system) and Atomic Force Microscopy (AFM) were also carried out to confirm the immobilization of tyrosinase enzyme onto the microplate well surface. This immobilized biocomponent was then integrated with an optical transducer for l-Dopa detection and it showed good reproducibility. The sensing property of the system was studied by measuring the initial rate of dopachrome formation at 475 nm. The calibration plot gave a linear range of detection from 10–1000 μM and the detection limit was calculated to be 3 μM. The immobilized biocomponent was stable for 41 days and was reused up to nine times. Spiked samples (blood plasma) were also analyzed using this biocomponent. This microplate based biosensor thus provides a convenient system for detection of multiple samples in a single run.  相似文献   

14.
Engin Asav 《Talanta》2009,78(2):553-987
In this study, a new biosensor based on the inhibition of tyrosinase for the determination of fluoride is described. To construct the biosensor tyrosinase was immobilized by using gelatine and cross-linking agent glutaraldehyde on a Clark type dissolved oxygen (DO) probe covered with a teflon membrane which is sensitive for oxygen. The phosphate buffer (50 mM, pH 7.0) at 30 °C were established as providing the optimum working conditions. The method is based on the measurement of the decreasing of dissolved oxygen level of the interval surface that related to fluoride concentration added into reaction medium in the presence of catechol. Inhibitor effect of fluoride results in decrease in dissolved oxygen concentration. The biosensor response depends linearly on fluoride concentration between 1.0 and 20 μM with a response time of 3 min.In the characterization studies of the biosensor some parameters such as reproducibility, substrate specificity and storage stability were carried out. From the experiments, the average value (x), Standard deviation (S.D) and coefficient of variation (C.V %) were found as 10.5 μM, ± 0.57 μM, 5.43%, respectively for 10 μM fluoride standard.  相似文献   

15.
A colloidal suspension of nanostructured poly(N-butyl benzimidazole)-graphene sheets (PBBIns-Gs) was used to modify a gold electrode to form a three-dimensional PBBIns-Gs/Au electrode that was sensitive to hydrogen peroxide (H2O2) in the presence of acetic acid (AcOH). The positively charged nanostructured poly(N-butyl benzimidazole) (PBBIns) separated the graphene sheets (Gs) and kept them suspended in an aqueous solution. Additionally, graphene sheets (Gs) formed “diaphragms” that intercalated Gs, which separated PBBIns to prevent tight packing and enhanced the surface area. The PBBIns-Gs/Au electrode exhibited superior sensitivity toward H2O2 relative to the PBBIns-modified Au (PBBIns/Au) electrode. Furthermore, a high yield of glucose oxidase (GOD) on the PBBIns-Gs of 52.3 mg GOD per 1 mg PBBIns-Gs was obtained from the electrostatic attraction between the positively charged PBBIns-Gs and negatively charged GOD. The non-destructive immobilization of GOD on the surface of the PBBIns-Gs (GOD-PBBIns-Gs) retained 91.5% and 39.2% of bioactivity, respectively, relative to free GOD for the colloidal suspension of the GOD-PBBIns-Gs and its modified Au (GOD-PBBIns-Gs/Au) electrode. Based on advantages including a negative working potential, high sensitivity toward H2O2, and non-destructive immobilization, the proposed glucose biosensor based on an GOD-PBBIns-Gs/Au electrode exhibited a fast response time (5.6 s), broad detection range (10 μM to 10 mM), high sensitivity (143.5 μA mM−1 cm−2) and selectivity, and excellent stability. Finally, a choline biosensor was developed by dipping a PBBIns-Gs/Au electrode into a choline oxidase (ChOx) solution for enzyme loading. The choline biosensor had a linear range of 0.1 μM to 0.83 mM, sensitivity of 494.9 μA mM−1 cm−2, and detection limit of 0.02 μM. The results of glucose and choline measurement indicate that the PBBIns-Gs/Au electrode provides a useful platform for the development of oxidase-based biosensors.  相似文献   

16.
《Electroanalysis》2017,29(7):1741-1748
The determination of lead ions by inhibition of choline oxidase enzyme has been evaluated for the first time using an amperometric choline biosensor. Choline oxidase (ChOx) was immobilized on a glassy carbon electrode (GCE) modified with multiwalled carbon nanotubes (MWCNT) through cross‐linking with glutaraldehyde. In the presence of ChOx, choline was enzymatically oxidized into betaine at –0.3 V versus Ag/AgCl reference electrode, lead ion inhibition of enzyme activity causing a decrease in the choline oxidation current. The experimental conditions were optimised regarding applied potential, buffer pH, enzyme and substrate concentration and incubation time. Under the best conditions for measurement of the lowest concentrations of lead ions, the ChOx/MWCNT/GCE gave a linear response from 0.1 to 1.0 nM Pb2+ and a detection limit of 0.04 nM. The inhibition of ChOx by lead ions was also studied by electrochemical impedance spectroscopy, but had a narrower linear response range and low sensitivity. The inhibition biosensor exhibited high selectivity towards lead ions and was successfully applied to their determination in tap water samples.  相似文献   

17.
Two amperometric enzyme biosensor systems, based on glycerol dehydrogenase/diaphorase (GDH/DP) and glycerol kinase/glycerol-3-phosphate oxidase/peroxidase (GK/GPOx/HRP), were developed and used for estimation of glycerol content in a complex biological fluids. Enzymes were immobilized on interchangeable membranes by PCS-prepolymer technique. Buffers containing ferricyanide/NAD+ or ferrocyanide/ATP were used for measurements with GDH/DP and GK/GPOx/HRP biosensor, respectively. FIA assay of glycerol biosensor was characterized by a linear range of 0.01-1 or 0.01-1.5 mM glycerol, sensitivity of 6.02 or 1.42 mA/M cm2 and with signal loss of 40% after 90 h or 30% after 16 h during continuous operation at a sample throughput of 10 injections/h for GDH/DP or GK/GPOx/HRP biosensors, respectively. Both biosensors were successfully used for off-line monitoring of glycerol during microbial transformation of glycerol to 1,3-propanediol using an automatized flow-through system. The results were consistent with those obtained with HPLC. The stability of described biosensor systems was sufficient for monitoring and control of fermentation process within 24 h. The storage stability of enzyme membranes was several months.  相似文献   

18.
We report a simple and rapid procedure that leads to incorporation of mediator and introduction of amine functionality onto the surface of screen-printed carbon electrodes (SPCE). The electrodes were doped with cobalt phthalocyanine (CoPc) by enhanced adsorption in a process that uses minimal amounts of this redox mediator as compared with CoPc loaded inks. The CoPc-doped SPCE showed a substantially increased sensitivity to hydrogen peroxide and thiocholine as compared to unmodified electrodes. This greatly facilitated their use as transducers for the construction of amperometric biosensors based on enzymes producing oxidizable products such as hydrogen peroxide or thiols. Immobilisation of enzymes including glucose oxidase, acetylcholinesterase and choline oxidase was achieved through their multi-contact electrostatic interaction with polyethyleneimine (PEI) which was electrodeposited on the surface of CoPc-doped electrodes in one step from ethanolic solution. The efficiency of enzyme immobilisation was shown to depend on the molecular weight of the PEI used, reaching a maximum for 25 kDa PEI. The biosensors shown sensitivity to glucose at 130 nA mM−1 (LOD 0.15 mM) and to acetylcholine at 70 nA mM−1 (LOD 0.10 mM) under +0.6 V. Detection of glucose has been demonstrated at +0.4 V with the sensitivity of 60 nA mM−1 and LOD of 0.33 mM. Possibility of the inhibition analysis of pesticides has been shown for acetylcholinesterase-based sensors.  相似文献   

19.
A sensitive biosensor with supramolecular architecture was designed and implemented here to detect choline. Choline oxidase and horseradish peroxidase were assembled onto the polymer of thiolated β-cyclodextrin and platinum nanoparticles modified gold electrode through 1-adamantane carboxylic acid coupling. Square wave voltammetry showed that the reduction currents at 0.38 mV had a linear relationship with the logarithms of choline concentrations in the range of 10−9-10−2 M, and the detection limit was down to 0.1 nM. Such biosensor also exhibited excellent selectivity, reproducibility and stability.  相似文献   

20.
The preparation of a tyrosinase biosensor based on the immobilization of the enzyme onto a glassy carbon electrode modified with electrodeposited gold nanoparticles (Tyr-nAu-GCE) is reported. The enzyme immobilized by cross-linking with glutaraldehyde retains a high bioactivity on this electrode material. Under the optimized working variables (a Au electrodeposition potential of −200 mV for 60 s, an enzyme loading of 457 U, a detection potential of −0.10 V and a 0.1 mol l−1 phosphate buffer solution of pH 7.4 as working medium) the biosensor exhibited a rapid response to the changes in the substrate concentration for all the phenolic compounds tested: phenol, catechol, caffeic acid, chlorogenic acid, gallic acid and protocatechualdehyde. A R.S.D. of 3.6% (n = 6) was obtained from the slope values of successive calibration plots for catechol with the same Tyr-nAu-GCE with no need to apply a cleaning procedure to the biosensor. The useful lifetime of one single biosensor was of at least 18 days, and a R.S.D. of 4.8% was obtained for the slope values of catechol calibration plots obtained with five different biosensors. The kinetic constants and the analytical characteristics were calculated for all the phenolic compounds tested. The Tyr-nAu-GCE was applied for the estimation of the phenolic compounds content in red and white wines. A good correlation of the results (r = 0.990) was found when they were plotted versus those obtained by using the spectrophotometric method involving the Folin-Ciocalteau reagent.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号