首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 245 毫秒
1.
A pre-column derivatization high-performance liquid chromatographic method for glyphosate analysis has been developed. Derivatization of glyphosate was performed with 4-chloro-3,5-dinitrobenzotrifluoride (CNBF). In pH 9.5 H3BO3-Na2B4O7 media, the reaction of glyphosate with CNBF completed at 60 °C for 30 min. The labeled glyphosate was separated on a Kromasil C18 column (250 mm × 4.6 mm, 5 μm) at room temperature and UV detection was applied at 360 nm. The separation of labeled glyphosate was achieved within 15 min by gradient elution mode. Compared to other pre-column derivatization, this derivatization was performed more mildly, the derivative was more stable, and the detection limits of a few reagents were higher than CNBF, except 9-fluorenylmethyl chloroformate (FMOC-Cl) using fluorescence and mass spectrometry, however, this reagent avoid to be removed after derivatization like FMOC-Cl. The detection limit of glyphosate was 0.009 mg L−1 (S/N = 3) without preconcentration and reach MRL, which is set at the level of 0.1 mg L−1 in China. The method linearity correlation coefficient was 0.9999, in concentrations ranging from 0.3 to 48.5 mg L−1. The proposed method has been applied to the quantitative determination of glyphosate in environmental water with recoveries of 91.80-100.20% and R.S.D. of 2.27-6.80, depending on the sample investigated.  相似文献   

2.
This paper describes selenium determination based on Se0 preconcentration in the imprinted polymer (synthesized with 2.25 mmol SeO2, 4-vinylpyridine and 1-vinylimidazole) with subsequent detection on-line in HG-FAAS. During the synthesis, SeO2 is reduced to Se (0). Therefore, there are no MIP neither IIP in the present work, thus we denominated: AIP, i.e., atomically imprinted polymers. For the optimization of analytical parameters Doehlert design was used. The method presented limit of detection and limit of quantification of 53 and 177 ng L−1, respectively, and linear range from 0.17 up to 6 μg L−1 (r = 0.9936). The preconcentration factor (PF), consumptive index (CI) and concentration efficiency (CE) were 232; 0.06 mL and 58 min−1 respectively. The proposed method was successfully applied to determine Se in Brazil nuts (0.33 ± 0.03 mg kg−1), apricot (0.46 ± 0.02 mg kg−1), white bean (0.47 ± 0.03 mg kg−1), rice flour (0.47 ± 0.02 mg kg−1) and milk powder (0.22 ± 0.01 mg kg−1) samples. It was possible to do 12 analyzes per hour. Accuracy was checked and confirmed by analyzing certified reference material (DORM-2, dogfish muscle), and samples precision was satisfactory with RSD lower than 10%.  相似文献   

3.
Two miniature and compact optoelectronic devices fabricated by means of integration of light emitting diodes have been developed for turbidimetric and nephelometric measurements. These devices are operating according to paired-emitter-detector-diode (PEDD) principle. The detectors have been characterized using bovine serum albumin and Exton protein assay as a model analyte and a model analytical method, respectively. The developed detectors have been adapted for measurements under conditions of flow injection analysis (FIA). Under optimized conditions the turbidimetric flow system offers the range of linear response up to 400 mg L−1 with the detection limit at 20 mg L−1. The linear range and detection limit found for optimized nephelometric FIA system are 15–500 mg L−1 and 8 mg L−1, respectively. The PEDD-based FIA systems with the detector operating according to both modes of measurements have been successfully applied for urinalysis offering total protein determination at physiological and pathological levels with high throughput (over 60 injections per hour).  相似文献   

4.
A sequential injection analysis (SIA) using lab-on-valve with air segmentation and spectrophotometric detection was designed for copper(II) determination. It is based on the reaction of copper(II) and 2-carboxy-2′-hydroxy-5′-sulfoformazyl benzene (Zincon) in a weak alkaline solution between the air zones. Beer's Law was obeyed over the range of 0.1-2.0 mg L−1 copper(II) with a correlation coefficient 0.9985 and a slope of 0.2893 absorbance unit/mg L−1. The relative standard deviation was 2.0% for a series of 10 measurements of 0.5 mg L−1 copper(II) solution. The detection limit (3 S/N) and the limit of quantification (LOQ) were 0.05 and 0.17 mg L−1 respectively. This method has been successfully applied to determination of copper(II) in wastewater with a sample throughput of 120 h−1. The method is superior to the batchwise method in that it provides fully automation, rapidity, less reagents and sample consumption with little waste generation.  相似文献   

5.
Tang Y  Wu M 《Talanta》2005,65(3):794-798
A method of quickly determining ascorbic acid and sorbic acid by capillary zone electrophoresis with ultraviolet detection was developed. The choice of background electrolyte, wavelength, injection time and applied voltage were discussed. Ascorbic acid and sorbic acid were well separated in 80 mmol L−1 boric acid-5 mmol L−1borax (pH = 8.0) in 5 min at the detecting wavelength of 270 nm. Under the optimum condition, the method has linear ranges of 2.54-352.00 mg L−1 for ascorbic acid and 1.08-336.39 mg L−1 for sorbic acid with the detection limit of 1.70 mg L−1 for ascorbic acid and 0.54 mg L−1 for sorbic acid, respectively. Other organic acids in fruit juices have no effect on the detection. This method is very feasible and simple and can be used to detect ascorbic acid and sorbic acid in fruit juices.  相似文献   

6.
Melchert WR  Rocha FR 《Talanta》2005,65(2):461-465
Nitrate determination in waters is generally carried out with cadmium filings and carcinogenic reagents or by reaction with phenolic compounds in highly concentrated sulfuric acid medium. In this work, it was developed a green analytical procedure for nitrate determination in natural waters based on direct spectrophotometric measurements in ultraviolet, using a flow-injection system with an anion-exchange column for separation of nitrate from interfering species. The proposed method employs only one reagent (HClO4) in a minimum amount (equivalent to 18 μL concentrated acid per determination), and allowed nitrate determination within 0.50-25.0 mg L−1, without interference of up to 200.0 mg L−1 humic acid; 1.0 mg L−1 NO2; 200.0 mg L−1 PO43−; 75.0 mg L−1 Cl; 50.0 mg L−1 SO42− and 15.0 mg L−1 Fe3+. The detection limit (99.7% confidence level) and the coefficient of variation (n = 20) were estimated as 0.1 mg L−1 and 0.7%, respectively. The results obtained for natural water samples were in agreement with those achieved by the reference method based on nitrate reduction with copperized cadmium at the 95% confidence level.  相似文献   

7.
Li Zhang  Shouzhuo Yao 《Talanta》2010,82(3):984-78
A novel method was developed for the analysis of four β-blockers, namely sotalol, carteolol, bisoprolol, and propranolol, in human urine by coupling carrier-mediated liquid phase microextraction (CM-LPME) to high performance liquid chromatography (HPLC). By adding an appropriate carrier in organic phase, simultaneous extraction and enrichment of hydrophilic (sotalol, carteolol, and bisoprolol) and hydrophobic (propranolol) drugs were achieved. High enrichment factors were obtained by optimizing the compositions of the organic phase, the acceptor solution, the donor solution, the stirring rate, and the extraction time. The linear ranges were from 0.05 to 10.0 mg L−1 for sotalol and carteolol, and from 0.05 to 8.0 mg L−1 for bisoprolol and propranolol. The limits of detection (S/N = 3) were 0.01 mg L−1 for sotalol, carteolol, and bisoprolol, and 0.005 mg L−1 for propranolol. The relative standard deviations were lower than 6%. The developed method exhibited high analyte preconcentration and excellent sample clean-up effects with little solvent consumption and was found to be sensitive and suitable for simultaneous determination of the above four drugs spiked in human urine. Furthermore, the successful analysis of propranolol in real urine specimens revealed that the determination of β-blockers in human urine is feasible using the present method.  相似文献   

8.
Poachanee Norfun 《Talanta》2010,82(1):202-207
A reverse flow injection analysis (rFIA) spectrophotometric method has been developed for the determination of aluminium(III). The method was based on the reaction of Al(III), quercetin and cetyltrimethylammonium bromide (CTAB), yielding a yellow colored complex in an acetate buffer medium (pH 5.5) with absorption maximum at 428 nm. The rFIA parameters that influence the FIA peak height have been optimized in order to obtain the best sensitivity and minimum reagent consumption. A linear relationship between the relative peak height and Al(III) concentrations were obtained over the concentration range of 0.02-0.50 mg L−1 with a correlation coefficient of 0.9998. The limit of detection (LOD, defined as 3σ) and limit of quantification (LOQ, defined as 10σ) were 0.007 and 0.024 mg L−1, respectively. The repeatability was 1.10% (n = 11) for 0.2 mg L−1 Al(III). The proposed method was applied to the determination of Al(III) in tap water samples with a sampling rate of 60 h−1. Results obtained were in good agreement with those obtained by the official ICP-MS method at the 95% confidence level.  相似文献   

9.
Polychlorotrifluoroethylene (PCTFE) in the form of beads was applied, as packing material for flow injection on-line column preconcentration and separation systems coupled with flame atomic absorption spectrometry (FAAS). Its performance characteristics were evaluated for trace copper determination in environmental samples. The on-line formed complex of metal with diethyldithiophosphate (DDPA) was sorbed on the PCTFE surface. Isobutyl methyl ketone (IBMK) at a flow rate of 2.8 mL min−1 was used to elute the analyte complex directly into the nebulizer-burner system of spectrophotometer. The proposed sorbent material reveal, excellent chemical and mechanical resistance, fast adsorption kinetics permitting the use of high sample flow rates up to 15 mL min−1 without loss of retention efficiency. For copper determination, with 90 s preconcentration time the sample frequency was 30 h−1, the enhancement factor was 250, which could be further improved by increasing the loading (preconcentration) time. The detection limit (3s) was cL = 0.07 μg L−1, and the precision (R.S.D.) was 1.8%, at the 2.0 μg L−1 Cu(II) level. For lead determination, the detection limit was cL = 2.7 μg L−1, and the precision (R.S.D.) 2.2%, at the 40.0 μg L−1 Pb(II) level. The accuracy of the developed method was evaluated by analyzing certified reference materials and by recovery measurements on spiked natural water samples.  相似文献   

10.
A single strand hollow fiber membrane (SSHFM) was developed for the on-line sample preparation for the flow based colorimetric determination of free iron levels in fruit juices. The SSHFM, as used, could separate Fe2+ from some spectrophotometric interfering agents in the fruit juice, such as pigments, solid suspensions and polysaccharides. The screening process was likely to have been primarily based on dialysis, wherein only ions or molecules that are smaller than the pores of the membrane can diffuse through while relatively larger molecules or particles could not. Two flow modes, a continuous and stopped flow, were studied. Factors that influenced the sensitivity (%dialysis) of the method, such as the flow rate, sample volume, flow direction and stopped flow time, were optimized. The stopped flow mode was found to be relatively more sensitive than the continuous flow mode and displayed a linear range of 1-30 mg L−1 Fe2+, a limit of detection of 0.5 mg L−1, and a % relative standard deviation of less than 2% (n = 8) for the analysis of 10 mg L−1 Fe2+ spiked grape juice samples. A sample throughput of 24 samples h−1, was attained without any further sample treatment.  相似文献   

11.
Manuela Kim 《Talanta》2007,72(3):1054-1058
A simple and sensitive HPLC post-derivatization method with colorimetric detection has been developed for the determination of N-nitroso glyphosate in samples of technical glyphosate. Separation of the analyte was accomplished using an anionic exchange resin (2.50 mm × 4.00 mm i.d., 15 μm particle size, functional group: quaternary ammonium salt) with Na2SO4 0.0075 M (pH 11.5) (flow rate: 1.0 mL min−1) as mobile phase. After separation, the eluate was derivatized with a colorimetric reagent containing sulfanilamide 0.3% (w/v), [N-(1-naphtil)ethilendiamine] 0.03% (w/v) and HCl 4.5 M in a thermostatized bath at 95 °C. Detection was performed at 546 nm. All stages of the analytical procedure were optimized taking into account the concept of analytical minimalism: less operation times and costs; lower sample, reagents and energy consumption and minimal waste. The limit of detection (k = 3) calculated for 10 blank replicates was 0.04 mg L−1 (0.8 mg kg−1) in the solid sample which is lower than the maximum tolerable accepted by the Food and Agriculture Organization of the United Nations.  相似文献   

12.
A multi-pumping flow system (MPFS) for the spectrophotometric determination of dissolved orthophosphate and dissolved organic phosphorus in wastewater samples is proposed. The determination of orthophosphate is based on the vanadomolybdate method. In-line ultraviolet photo-oxidation is employed to mineralise organic phosphorus to orthophosphate prior to detection. A solenoid valve allows the deviation of the flow towards the UV-lamp to carry out the determination of organic phosphorus.Calibration was found to be linear up to 20 mg P L−1, with a detection limit (3sb/S) of 0.08 mg P L−1, an injection throughput of 75 injections h−1 and a repeatability (R.S.D.) of 0.6% for the direct determination of orthophosphate. On the other hand, calibration graphs were linear up to 40 mg P L−1, with a detection limit (3sb/S) of 0.5 mg P L−1, an injection throughput of 11 injections h−1 and a repeatability (R.S.D.) inferior to 2.3% for the procedures involving UV photo-oxidation.  相似文献   

13.
A simple, specific and sensitive sequential injection analysis (SIA) system based on non-immunoassay fluorescent detection has been developed for the determination of urinary albumin. The specific binding of the dye Albumin Blue 580 (AB 580) to albumin in urine generated high emission fluorescent signals. The excitation and emission wavelengths were set at 590 and 610 nm, respectively. The analytical range was obtained from 1 to 100 mg L−1, with a detection limit of 0.3 mg L−1 (S/N = 3). The SIA system gave high precision with relative standard deviations (R.S.D.s) of 0.9% and 1.4% when evaluated with 15 and 100 mg L−1 albumin (n = 15), respectively. The method exhibited good reproducibility, as assessed by performing four analytical curves on different days, and intra-run CVs (2.3-3.3%) and inter-run CVs (3.8%) were obtained. Rapid operation was achieved with a sample throughput of 37 h−1. This method was successfully applied to the determination of urinary albumin, and the method was highly correlated with the immunoturbidimetric method (r2 = 0.965; n = 72).  相似文献   

14.
Silva SG  Rocha FR 《Talanta》2010,83(2):559-564
A flow system designed with solenoid micro-pumps is proposed for fast and greener spectrophotometric determination of free glycerol in biodiesel. Glycerol was extracted from samples without using organic solvents. The determination involves glycerol oxidation by periodate, yielding formaldehyde followed by formation of the colored (3,5-diacetil-1,4-dihidrolutidine) product upon reaction with acetylacetone. The coefficient of variation, sampling rate and detection limit were estimated as 1.5% (20.0 mg L−1 glycerol, n = 10), 34 h−1, and 1.0 mg L−1 (99.7% confidence level), respectively. A linear response was observed from 5 to 50 mg L−1, with reagent consumption estimated as 345 μg of KIO4 and 15 mg of acetylacetone per determination. The procedure was successfully applied to the analysis of biodiesel samples and the results agreed with the batch reference method at the 95% confidence level.  相似文献   

15.
An on-line system with vapour generation (VG) and Fourier transform infrared (FTIR) spectrometric detection has been developed for the determination of free ammonium and organic nitrogen in agrochemical formulations containing hydrolyzed proteins. Commercial samples were digested, in batch mode, with sulphuric acid and the obtained solution was alkalinized on-line to transform the NH4+ to NH3 that was continuously monitored by FTIR. Free ammonium was determined in the same system after simple dilution of undigested samples with water. Different gas phase separators were assayed in order to introduce gaseous NH3 into a home made IR gas cell of 10 cm pathlength, where the corresponding FTIR spectra were acquired by accumulating 10 scans per spectrum. The 967.0 cm−1 band was used for the quantification of ammonia. The figures of merit of the proposed method involve a linear range up to 100 mg L−1, a limit of detection (3σ) of 1.4 mg L−1 of N, a limit of quantification (10σ) of 4.8 mg L−1 of N, a precision (R.S.D.) of 3.0% for 10 replicate determinations of a 10.0 mg L−1 of N and a sample measurement frequency of 60 h−1. The method was successfully applied to the determination of free ammonium and total N in commercial amino acid formulations and results compare well with those obtained by the Kjeldhal method.  相似文献   

16.
In this study a method for the determination of cadmium in fuel alcohol using solid-phase extraction with a flow injection analysis system and detection by flame atomic absorption spectrometry was developed. The sorbent material used was a vermicompost commonly used as a garden fertilizer. The chemical and flow variables of the on-line preconcentration system were optimized by means of a full factorial design. The selected factors were: sorbent mass, sample pH, buffer concentration and sample flow rate. The optimum extraction conditions were obtained using sample pH in the range of 7.3-8.3 buffered with tris(hydroxymethyl)aminomethane at 50 mmol L−1, a sample flow rate of 4.5 mL min−1 and 160 mg of sorbent mass. With the optimized conditions, the preconcentration factor, limit of detection and sample throughput were estimated as 32 (for preconcentration of 10 mL sample), 1.7 μg L−1 and 20 samples per hour, respectively. The analytical curve was linear from 5 up to at least 50 μg L−1, with a correlation coefficient of 0.998 and a relative standard deviation of 2.4% (35 μg L−1, n = 7). The developed method was successfully applied to spiked fuel alcohol, and accuracy was assessed through recovery tests, with recovery ranging from 94% to 100%.  相似文献   

17.
In this study a method for the determination of low concentrations of silver in waters using solid-phase extraction with a flow injection analysis system and detection by flame atomic absorption spectrometry (FAAS) was developed. Moringa oleifera seeds were used as a biosorbent material. Chemical and flow variables of the on-line preconcentration system such as sample pH and flow rate, preconcentration time, eluent concentration and sorbent mass were studied. The optimum preconcentration conditions were obtained using sample pH in the range of 6.0-8.0, preconcentration time of 4 min at a flow rate of 3.5 mL min− 1, 0.5 mol L− 1 HNO3 eluent at a flow rate of 4.5 mL min− 1 and 35 mg of sorbent mass. With the optimized conditions, the preconcentration factor, precision, detection limit and sample throughput were estimated as 35 (for preconcentration of 14 mL sample), 3.8% (5.0 μg L− 1, n = 7), 0.22 μg L− 1 and 12 samples per hour, respectively. The developed method was successfully applied to mineral water and tap water, and accuracy was assessed through analysis of a certified reference material for water (APS-1071 NIST) and recovery tests, with recovery ranging from 94 to 101%.  相似文献   

18.
We report about the use of carbon paste electrode modified with kaolinite for analytical detection of trace lead(II) in domestic water by differential pulse voltammetry. Kaolinite clay was modified with tripolyphosphate (TPP) by impregnation method. The results show that TPP in kaolinite clay plays an important role in the accumulation process of Pb(II) on the modified electrode surface. The electroanalytical procedure for determination of Pb(II) comprised two steps: chemical accumulation of the analyte under open-circuit conditions, followed by electrochemical detection of the pre-concentrated species using differential pulse voltammetry. The analytical performance of this system has been explored by studying the effects of preconcentration time, carbon paste composition, pH, supporting electrolyte concentration, as well as interferences due to other ions. The calculated detection limit based on the variability of a blank solution (3sb criterion) for 10 measurements was 8.4 × 10−8 mol L−1, and the sensitivity determined from the slope of the calibration graph was 0.910 mol L−1. The reproducibility (RSD) for five replicate measurements at 1.0 mg L−1 lead level was 1.6%. The results indicate that this electrode is sensitive and effective for the determination of Pb2+.  相似文献   

19.
A simple chiral high-performance liquid chromatography (HPLC) method with ultraviolet (UV) and circular dichroism (CD) detection was developed and validated for measuring benalaxyl enantiomers using (R,R) Whelk-O 1 column. The effects of mobile phase composition and column temperature on the entioseparation were investigated. A CD detector was used to determine the elution order of the enantiomers. Excellent resolution was easily obtained using n-hexane-polar organic alcohols mobile phase. The chiral recognition mechanism was also discussed. Based on the developed chiral HPLC method, enantioselective analysis methods for this fungicide in environment matrix (soil and water) were developed and validated. Good linearities were obtained over the concentration range of 0.25-25 mg L−1 for both enantiomers. Liquid-liquid extraction and solid phase extraction (SPE) were used for the enrichment and cleanup of soil and water samples. Recoveries for the two enantiomers were 79-91% at 0.02, 0.04 and 0.2 mg kg−1 levels from soil, and 89-101% at 0.0025, 0.01 and 0.05 mg L−1 levels from water. Run-to-run and day-to-day assay precisions were below 10% for both enantiomers at concentrations of 0.5, 1 and 5 mg L−1. Individual detection limits of the two enantiomers were both 2 ng. Limits of detection (LOD) were 0.004 mg kg−1 in soil and 0.001 mg L−1 in water.  相似文献   

20.
Zhifeng Tu  Lijun Zhang  Qun He  Jianping Shi  Ru Gao 《Talanta》2010,80(3):1205-1747
A new method that utilizes 1-(2-aminoethyl)-3-phenylurea-modified silica gel as a solid-phase extractant has been developed for preconcentration of trace Sc(III) prior to the measurement by inductively coupled plasma atomic emission spectrometry (ICP-AES). Experimental conditions for effective adsorption of trace level of Sc(III) were optimized using batch and column procedures in detail. The optimum pH value for the separation of Sc(III) on the new sorbent was 4 and complete elution of Sc(III) from the sorbent surface was carried out using 1.0 mL of 0.1 mol L−1 HCl. Common coexisting ions did not interfere with the separation and determination of the analyte. The maximum static adsorption capacity of the sorbent at optimum conditions was found to be 32.5 mg g−1 while the time of 95% adsorption was less than 2 min. The detection limit of present method was found to be 0.091 μg g−1, and the relative standard deviation (RSD) was lower than 3.0% (n = 8). The method was successfully applied for the preconcentration of trace Sc(III) in the environmental samples with satisfactory results.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号