首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 967 毫秒
1.
The efficiencies and performances of silver nanoparticle loaded activated carbon modified with 2-(4-isopropylbenzylideneamino)thiophenol (IPBATP-Ag-NP-AC) and activated carbon modified with IPBATP (IPBATP-AC), as new sorbents, were evaluated for separation and preconcentration of Cu2+, Zn2+, Co2+, Cd2+ and Pb2+ ions from real environmental samples. The retained metals content was reversibly eluted using 5?mL of CH3COOH (6.0?mol?L?1) and/or 10?mL of 4.0?mol?L?1 HNO3 for IPBATP-Ag-NP-AC and IPBATP-AC, respectively. The experimental parameters influence the recoveries of metal ions including pH, amounts of ligand and supports, condition of eluents, sample and eluent flow rates of has been investigated. The preconcentration factors were found to be 100 for Zn2+, Cd2+, Co2+, Cu2+ and 50 for Pb2+ ions using IPBATP-Ag-NP-AC, and 50 for Zn2+, Cd2+, Co2+, Cu2+ and 25 for Pb2+ ions using IPBATP-AC. The detection limit of both SPE-based sorbents was between 1.6–2.5?ng?mL?1 for IPBATP-AC and 1.3–2.5?ng?mL?1 for IPBATP-Ag-NP-AC. The proposed methods have been successfully applied for the extraction and determination of the understudy metal ions content in some real samples with extraction efficiencies higher than 90% and relative standard deviations (RSD) lower than 2.4%.  相似文献   

2.
A stable chelating resin matrix was prepared by covalently linking resorcinol with polyurethane foam matrix through a –N=N– group. Preconcentration and determination of trace Ag+ and Hg2+ ions from samples of different origin, using Res-PUF, were studied. Various conditions influencing the sorption of these metal ions onto Res-PUF were optimized. The kinetics of sorption of the Ag+ and Hg2+ by Res-PUF were found to be fast, reached equilibrium in few minutes (5–10?min) and followed a first-order rate equation with an overall rate constant k in 0.102 and 0.267/min, respectively. Study of the variation of the sorption of the tested metal ions with temperature yielded average values for ΔG, ΔH and ΔS of ?3.94, ?22.02 and ?58.37, respectively. The mean free sorption energy (E) computed from the Dubinin–Radushkevich (D–R) isotherm was found to be equal to 8.91 kJ/mol, which reflects the chelation sorption process. The capacities of the foam material were 0.15 and 0.07?mmol/g for Ag+ and Hg2+, respectively. Preconcentration factors of?>?50 were achieved (RSD?≈?5.99). The proposed preconcentration procedure was applied successfully to the determination of trace metal ions in natural and wastewater samples.  相似文献   

3.
Multiwalled carbon nanotubes chemically functionalized with 2-((3-silylpropylimino) methyl) phenol (SPIMP-MWCNT) and successfully applied for the solid phase extraction (SPE) of some metal ions in food samples. The influences of the analytical parameters including pH, amounts of solid phase, eluent conditions (type, volume and concentrations), sample volume and interference of some metal ions on the recoveries of ions Cu2+, Pb2+, Fe2+, Ni2+ and Zn2+ ion were investigated. The metal ions retained on SPIMP-MWCNT was eluted using 6?mL of 4?mol?L?1 HNO3 solution and their content was determined by flame atomic absorption spectrometry (FAAS) with recoveries more than 95% and relative standard deviations (n?=?5) between 2.4–3.4% for both reproducibility and repeatability. The detection limit of this metal ions was between 1.0–2.6?ng?mL?1 (3S b , n?=?10) and their preconcentration factor was 100, while their loading capacity was above 32.9?mg?g?1 of SPIMP-MWCNT. The proposed method was successfully applied for the preconcentration and determination of analytes in different samples.  相似文献   

4.
In the present paper, we used single-stranded poly-T (100% thymine bases) and poly-C (100% cytosine bases) nucleic acids as DNA probes for selective and sensitive individual electrochemical determination of Hg2+ and Ag+, respectively, on the multi-walled carbon nanotube paste electrodes (MWCNTPEs) using [Fe(CN)6]3?/4? as electroactive labels. In the presence of Hg2+ and Ag+, the probe–Hg2+/Ag+ interactions through T–Hg2+–T and C–Ag+–C complexes formation could cause the formation of a unimolecular hybridized probe. This structure of probe led to its partial depletion from electrode surface and facilitation of electron transfer between [Fe(CN)6]3?/4? redox couple and electrode surface, resulting in the enhanced differential pulse voltammetry (DPV) oxidation current of [Fe(CN)6]3?/4? at the probe-modified electrode surface. We applied the difference in the oxidation peak currents of [Fe(CN)6]3?/4? before and after Hg2+/Ag+–DNA probe bonding (?I) for electrochemical determination of these heavy metal ions. Detection limits were 8.0?×?10?12 M and 1.0?×?10?11 M for Hg2+ and Ag+ ions determination, respectively. The biosensors were utilized to determine the weight percent of toxic metals, i.e., silver and mercury in dental amalgam filling composition. The results of their practical applicability in analysis of the amalgam sample were satisfactory.  相似文献   

5.
In this study, a carbon paste electrode modified with a novel 1-(3-aminopropyl) imidazole functionalised crosslinked chlorosulfonated poly(styrene)-divinyl benzene polymer was used for selective and sensitive determination of the trace amounts of Pb2+, Cu2+ and Hg2+ ions by square wave anodic stripping voltammetry. The effect of some parameters such as paste composition, pH, preconcentration time, reduction potential and time, type of supporting electrolyte and potential scan rate on the determination of metal ions were investigated to find the optimal conditions. The effective open-circuit accumulation of the studied metal ions was succeeded only by the modification of the carbon paste electrode with functional polymer. For 6 min open-circuit preconcentration, the detection limit of Pb2+, Cu2+ and Hg2+ was found to be 5, 9 and 14 µgL?1, respectively at 100 mVs?1. The results confirmed that the lower concentration levels of these trace metal ions can be determined with the increase of preconcentration time and/or potential scan rate. Good detection limits and large dynamic concentration ranges were also obtained for their binary and ternary mixtures. The optimised method was successively applied to determine the concentration of Pb2+, Cu2+ ions in the tap water sample and Cu2+ ion in the waste water sample in the presence of possible interfering species (RSD<1%, recoveries 96–110% for 4 min preconcentration).  相似文献   

6.
 本文报道了一种合成硫杂冠醚聚合物的新方法。以聚(2′-氯乙基-2,3-环硫丙基醚)为预聚物与二巯基化合物通过大分子反应直接环化,一步法合成了四种以聚硫醚为主链的新型硫杂冠醚聚合物(PD1-PD4)。并测定了它们对Ag+、Au3+)、Pd2+、Pt4+、Cu2+、Hg2+、Zn2+、Cd2+、Pb2+、Mg2+、K+、Ns+等金属离子的络合性能。结果表明:它们除不络合K+、Na+、Mg2+、Pb2+外,对其它八种离子有不同程度的络合,其中对Ag+、Au3+、Pd2+等贵金属离子的络合容量较高。  相似文献   

7.
A solid phase extraction system for separation and preconcentration of trace amounts of Pb(II), Ni(II), Cd(II) and Cu(II) is proposed. The procedure is based on the adsorption of Pb2+, Ni2+, Cd2+ and Cu2+ ions on a column of 1-(2-pyridylazo)-2-naphthol (PAN) immobilised on surfactant-coated clinoptilolite prior to their determinations by Flame Atomic Absorption Spectroscopy (FAAS). The effective parameters including pH, sample volume, sample flow rate and eluent flow rate were also studied. The analytes collected on the column were eluted with 5 mL of 1 mol L?1 nitric acid. A concentration factor of 180 can be achieved by passing 900 mL of sample through the column. The detection limits (3 s) for Cd, Cu, Pb and Ni were found to be 0.28, 0.12, 0.44 and 0.46 µg L?1, respectively. The relative SDs at 10 µg L?1 (n = 10) for analytes were in the range of 1.2–1.4%. The method was applied to the determination of Pb, Ni, Cd and Cu in water samples.  相似文献   

8.
In the present study, the ?5-(4-dimethylaminobenzylidene)rhodanin-modified SBA-15? was applied as stable solid sorbent for the separation and preconcentration of trace amounts of cobalt ions in aqueous solution. SBA-15 was modified by ?5-(4-dimethylaminobenzylidene)rhodanin reagent. The sorption of Co2+ ions was done onto modified sorbent in the pH range of 6.8–7.9 and desorption occurred in 5.0 mL of 3.0 mol L?1 HNO3. The results exhibit a linear dynamic range from 0.01 to 6.0 mg L?1 for cobalt. Intra-day (repeatability) and inter-day (reproducibility) for 10 replicated determination of 0.06 mg L?1 of cobalt was ±1.82% and ?±1.97%?. Detection limit was 4.2 µg L?1 (3Sb, n = 5) and preconcentration factor was 80. The effects of the experimental parameters, including the sample pH, flow rates of sample and eluent solution, eluent type and interference ions were studied for the preconcentration of Co2+. The proposed method was applied for the determination of cobalt in standard samples, water samples and agricultural products.  相似文献   

9.
A new poly(p‐phenylene ethynylene) derivative with pendant 2,2′‐bipyridyl groups and glycol units (PPE‐bipy) has been prepared, and its metal ion sensing properties were investigated. The polymer of PPE‐bipy exhibited high selectivity for Hg2+ as compared with Li+, Na+, K+, Ba2+, Ca2+, Mg2+, Al3+, Mn2+, Ag+, Zn2+, Pb2+, Ni2+, Cd2+, Cu2+, Co,2+ and Fe3+ in THF/EtOH (1:1, v/v) solution. The fluorescence of PPE‐bipy was efficiently quenched by Hg2+ ions, and the detection limit was found to be 8.0 nM in a THF/EtOH (1:1, v/v) solvent system. PPE‐bipy also showed a selective chromogenic behavior toward Hg2+ ions by changing the color of the solution from slight yellow to colorless, which can be detected with the naked eye. © 2008 Wiley Periodicals, Inc. J Polym Sci Part A: Polym Chem 46: 1998–2007, 2008  相似文献   

10.
Trace amounts of Fe3+, Pb2+, Cu2+, Ni2+, Co2+ and Zn2+ ions were efficiently enriched following complexation with silica-gel chemically functionalized with 2-((3-silylpropylimino)methyl)-5-bromophenol. The enriched metal ions efficiently eluted with 6?mL of 4.0?mol?L?1 nitric acid and their metal contents were determined by flame atomic absorption spectrometry (FAAS). The influences of the analytical parameters and experimental variables on the recoveries of the metal ions under study were investigated and optimized. The method has high sorption preconcentration efficiency even in the presence of various interfering ions. At optimum values of all variables the method is applicable for analysis of real samples with recoveries in the range of 95 to 105% with RSD lower than 4.2% and detection limits between 1.4 and 2.8?µg?L?1.  相似文献   

11.
New thiacalix[4]arenes appended with three amide functions have been prepared. Their conformations have been solved thanks to 1H NMR 2D correlation spectroscopy (COSY) and nuclear overhauser and exchange spectroscopy (NOESY). The complexation ability of these ligands towards various metal ions (Cd2 + , Pb2 + , Pd2 + , Ni2 + , Hg2 + , Hg+, Ag+, Zn2 +  and Cu2 + ) has been investigated by the UV–vis absorption and the stoichiometry of the metal–ligand complexes was determined.  相似文献   

12.
A new glassy carbon electrode modified with novel calix[4]‐arene derivative was prepared and then applied to the selective recognition of lead ion in aqueous media by cyclic and square wave voltammetry. A new anodic stripping peak at ? 0.92 V (vs. Ag/Ag+) in square wave voltammogram can be obtained by scanning the potential from ? 1.5 to ? 0.6 V, of which the peak current is proportional to the concentration of Pb2+. The modified electrode in 0.1 mol/L HNO3 solution showed a linear voltammetric response in the range of 2.0 × 10–8–1.0 × 10–6 mol/L and a detection limit of 6.1 × 10–9 mol/L. In the modified glassy carbon electrode no significant interference occurred from alkali, alkaline and transition metal ions except Hg2+, Ag+ and Cu2+ ions, which can be eliminated by the addition of KSCN. The proposed method was successfully applied to determine lead in aqueous samples.  相似文献   

13.
An ion-selective bulk optode (ISBO) for sensing Cu2+ and Pb2+ ions based on plasticized poly(vinyl chloride) containing 1,10-dibenzyl-1,10-diaza-18-crown-6 (DBzDA18C6) as ionophore and 1-(2-pyridylazo)-2-naphthol (PAN) as chromoionophore was prepared. The effects of DBzDA18C6/PAN and NaTPB/PAN mole ratios on the response behavior of the ISBO were investigated. The ISBO membrane shows enhanced selectivities for Cu2+ (at 530 nm) and Pb2+ (at 467 nm) over alkali, alkaline earth and other transition metal ions. The optical selectivity coefficients were measured using the separate solution method (SSM) in the two corresponding wavelengths at pH=5. The detection limit for Cu2+ and Pb2+ are 3.2×10−7 and 1.0×10−8 M, respectively.  相似文献   

14.
Sodium-dicyclohexyl- 18-crown-6 complex cation was used as carrier for the uphill transport of zinc as Zn(SCN)42? complex anion. By using L-cysteine as a metal ion acceptor in the receiving phase at the optimized pH of 7.6, the amount of zinc transport through the liquid membrane after 90 min was 97.2 ± 1.0%. The selectivity and efficiency of zinc transport from aqueous solutions containing equimolar mixtures of Ag+, Cd2+ Co2+, Cu2+, Fe2+, Ni2+, Pb2+, Pd2+, Sr2+, Bi3+, Cr3+ and Fe3+ ions was investigated. In the presence of NH2OH.HCl as a suitable masking agent in the source phase, the interfering effect of Cu2+ and Pb2+ ions was diminished drastically.  相似文献   

15.
A new class of solid‐phase extraction column prepared with grafted mercapto‐silica polymerized high internal phase emulsion particles was used for the preconcentration of trace lead. First, mercapto‐silica polymerized high internal phase emulsion particles were synthesized by using high internal phase emulsion polymerization and carefully assembled in a polyethylene syringe column. The influences of various parameters including adsorption pH value, adsorption and desorption solvents, flow rate of the adsorption and desorption procedure were optimized, respectively, and the suitable uploading sample volumes, adsorption capacity, and reusability of solid phase extraction column were also investigated. Under the optimum conditions, Pb2+ could be preconcentrated quantitatively over a wide pH range (2.0–5.0). In the presence of foreign ions, such as Na+, K+, Ca2+, Zn2+, Mg2+, Cu2+, Fe2+, Cd2+, Cl? and NO3?, Pb2+ could be recovered successfully. The prepared solid‐phase extraction column performed with high stability and desirable durability, which allowed more than 100 replicate extractions without measurable changes of performance. The feasibility of the developed method was further validated by the extraction of Pb2+ in rice samples. At three spiked levels of 40.0, 200 and 800 μg/kg, the average recoveries for Pb2+ in rice samples ranged from 87.3 to 105.2%.  相似文献   

16.
Abstract

The ensemble of 2,6-bis(2-chlorophenyl)dithiazolo[4,5-b:5',4'-e]pyridine 1 with Pd2+ ions (1?Pd2+) was prepared for the detection of cyanide ions (CN¯) in 50% aqueous methanol. Among the tested metal ions, only Pd2+ sensitively induced the red shift of the absorption bands and the complete decrease of fluorescence emission. The detection limit toward Pd2+ was 2?ppb. The ensemble 1?Pd2+ selectively and rapidly detected a low concentration of cyanide ions by a colorimetric change (40?ppb) as well as a “turn-on” fluorescent response (5?ppb). Job’s plot revealed the complex formation with 1:1 stoichiometry. The binding and replacement mode of 1?Pd2+ and CN¯ were also confirmed by 1H NMR titrations and IR analysis. In general, a fast and selective recognition of CN¯ is reported.  相似文献   

17.
A novel fluorometric sensor bearing three dansyl moieties based on tris[2-(2-aminoethylthio)ethyl]amine was prepared by a simple approach using a conventional two-step synthesis. The sensor exhibits highly Hg2+-selective ON-OFF fluorescence quenching behavior in aqueous acetonitrile solutions and is shown to discriminate various competing metal ions, particularly Cu2+, Ag+, and Pb2+ as well as Ca2+, Cd2+, Co2+, Fe3+, Mn2+, Na+, Ni2+, and Zn2+, with a detection limit of 1.15 × 10−7 M or 23 ppb.  相似文献   

18.
The complexation reaction of dibenzopyridino-18-crown-6 (DBPY 18C6) with Co2+, Cu2+, Zn2+, Pb2+, Cd2+, Hg2+, and Ag+ have been studied in DMSO at 25°C by the spectrophotometric method. Murexide was used as a competitive colored ligand. The stoichiometry of metal ion-murexide and metal ions with DBPY18C6 complexes were estimated by mole ratio and continuous variation methods and emphasized by the KINFIT program. The stoichiometry of all the complexes was found to be 1: 1 (metal ion/ligand). The order of stability constants for the obtained metal ion-murexide complexes (1: 1) varies in the order Cu2+ > Cd2+ > Co2+ ∼ Pb2+ > Zn2+ > Ag+ > Hg2+. This trend shows that the transition metal ions clearly obey the Irving-Williams role. For the post-transition metal ions, the ionic radius and soft-hard behavior was the major affects in varying of this order. The dibenzopyridino-18-crown-6 complexes with the used metal ions vary as Ag+ > Pb2+ > Cu2+ > Cd2+ > Hg2+ > Zn2+ > Co2+. The article is published in the original.  相似文献   

19.
Bishnu Prasad Joshi 《Talanta》2009,78(3):903-1129
A novel fluorescent peptide sensor containing tryptophan (donor) and dansyl fluorophore (acceptor) was synthesized for monitoring heavy and transition metal (HTM) ions on the basis of metal ion binding motif (Cys-X-X-X-Cys). The peptide probe successfully exhibited a turn on and ratiometric response for several heavy metal ions such as Hg2+, Cd2+, Pb2+, Zn2+, and Ag+ in aqueous solution. The enhancements of emission intensity were achieved in the presence of the HTM ions by fluorescent resonance energy transfer (FRET) and chelation enhanced fluorescence (CHEF) effects. The detection limits of the sensor for Cd2+, Pb2+, Zn2+, and Ag+ were lower than the EPA's drinking water maximum contaminant levels (MCL). We described the fluorescent enhancement, binding affinity, and detection limit of the peptide probe for HTM ions.  相似文献   

20.
A column, solid phase extraction (SPE), preconcentration method was developed for determination of silver by using alumina coated with 1-((5-nitrofuran-2-yl)methylene)thiosemicarbazide and determination by flame atomic absorption spectrometry. The separation/preconcentration conditions for the quantitative recovery were investigated. At pH 2, the maximum sorption capacity of Ag+ was 7.5?mg?g?1. The linearity was maintained in the concentration range of 0.02–11.0?µg?mL?1 in the final solution or 0.14–1.10?×?104?ng?mL?1 in the original solution for silver. The preconcentration factor of 140 and relative standard deviation of ±1.4% was obtained, under optimum conditions. The limit of detection (LOD) was calculated as 0.112?ng?mL?1, based on 3σbl/m (n?=?8) in the original solutions. The proposed method was successfully applied to the determination trace amounts of silver in the environmental samples such as tea, rice and wheat flour, mint, and real water samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号