首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 328 毫秒
1.
In this work, we investigate the electrochemical activity of dopamine (DA) and uric acid (UA) using both a bare and a modified carbon paste electrode as the working electrode, with a platinum wire as the counter electrode and a silver/silver chloride (Ag/AgCl) as the reference electrode. The modified carbon paste electrode consists of multi-walled carbon nanotubes (>95%) treated with α-cyclodextrine, resulting in an electrode that exhibits a significant catalytic effect toward the electro-chemical oxidation of DA in a 0.2-M Britton–Robinson buffer solution (pH 5.0). The peak current increases linearly with the DA concentration within the molar concentration ranges of 2.0 × 10−6 to 5.0 × 10−5 M and 5.0 × 10−5 to 1.9 × 10−4 M. The detection limit (signal to noise >3) for DA was found to be 1.34 × 10−7 M, respectively. In this work, voltammetric methods such as cyclic voltammetry, chronoamperometry, chronocuolometry, differential pulse and square wave voltammetry, and linear sweep and hydrodynamic voltammetry were used. Cyclic voltammetry was used to investigate the redox properties of the modified electrode at various scan rates. The diffusion coefficient (D, cm2 s−1 = 3.05 × 10−5) and the kinetic parameters such as the electron transfer coefficient (α = 0.51) and the rate constant (k, cm3 mol−1 s−1 = 1.8 × 103) for DA were determined using electrochemical approaches. By using differential pulse voltammetry for simultaneous measurements, we obtained two peaks for DA and UA in the same solution, with the peak separation approximately 136 mV. The average recovery was measured at 102.45% for DA injection.  相似文献   

2.
A p-duroquinone (tetramethyl-p-benzoquinone) modified carbon paste electrode (DMCPE) was employed to study the electrocatalytic reduction of nitrite in aqueous solutions using cyclic voltammetry (CV), double potential-step chronoamperometry, and differential pulse voltammetry (DPV). It has found that under an optimum condition (pH 1.00), the reduction of nitrite at the surface of DMCPE occurs at a potential of about 660 mV less negative than that of an unmodified carbon paste electrode (CPE). The catalytic rate constant, kh, based on Andrieux and Saveant theoretical model was calculated as for scan rate 10 mV s-1. Also, the apparent diffusion coefficient, D app, was found as 2.5 × 10–10 and 3.61 × 10–5 cm2 s-1 for p-duroquinone in carbon paste matrix and nitrite in aqueous buffered solution, respectively. The values for αnα were estimated to be −0.65 and −0.19 for the reduction of nitrite at the surface of DMCPE and CPE, respectively. The electrocatalytic reduction peak currents showed a linear dependence on the nitrite concentration, and a linear analytical curve was obtained in the ranges of 5.0 × 10–5 M to 8.0 × 10–3 M and 6.0 × 10–6 M to 8.0 × 10–4 M of nitrite concentration with CV and DPV methods, respectively. The detection limits (2σ) were determined as 2.5 × 10–5 M and 4.3 × 10–6 M by CV and DPV methods. This method was also applied as a simple, selective and precise method for determination of nitrite in real samples (the weak liquor from the wood and paper factory of Mazandaran province in Iran) by using a standard addition method.  相似文献   

3.
 A novel ion-selective sensor for procaine hydrochloride has been proposed and applied successfully to analysis of pharmaceutical preparations. The sensor is based on modification of the Ag-electrode of an AT-cut piezoelectric quartz crystal with a PVC membrane containing procaine tetraphenylborate. A linear relation between the logarithm of the response frequency and the logarithm of the procaine hydrochloride concentration was found experimentally and could be explained by combination of a modified Sauerbrey equation and the Freundlich isotherm. The detection range was from 8.3 × 10−8 to 5.0 × 10−3 M with a detection limit of 8.3 × 10−8 M. The selectivity of the sensor and the influence of experimental parameters such as solution pH and detection time were investigated. Received February 10, 1999. Revision October 10, 1999.  相似文献   

4.
A simple sensor based on bare carbon ionic liquid electrode was fabricated for simultaneous determination of dihydroxybenzene isomers in 0.1 mol L−1 phosphate buffer solution (pH 6.0). The oxidation peak potential of hydroquinone was about 0.136 V, catechol was about 0.240 V, and resorcinol 0.632 V by differential pulse voltammetric measurements, which indicated that the dihydroxybenzene isomers could be separated absolutely. The sensor showed wide linear behaviors in the range of 5.0 × 10−7–2.0 × 10−4 mol L−1 for hydroquinone and catechol, 3.5 × 10−6–1.535 × 10−4 mol L−1 for resorcinol, respectively. And the detection limits of the three dihydroxybenzene isomers were 5.0 × 10−8, 2.0 × 10−7, 5.0 × 10−7 mol L−1, respectively (S/N = 3). The proposed method could be applied to the determination of dihydroxybenzene isomers in artificial wastewater and the recovery was from 93.9% to 104.6%.  相似文献   

5.
A ferrocenedicarboxylic acid modified carbon paste electrode was constructed and used as a fast and sensitive tool for the determination of captopril at trace level. It has been shown by direct current cyclic voltammetry and double step chronoamperometry that ferrocenedicarboxylic acid can catalyze the oxidation of captopril in aqueous buffer solution and produces a sharp oxidation peak current at about +0.49 vs. Ag/AgCl reference electrode. The square wave voltammetric peak currents of the electrode increased linearly with the corresponding captopril concentration in the range of 3.0 × 10−7–1.4 × 10−4M with a detection limit of 9.1 × 10−8 M. The influence of pH and potential interfering substances on the determination of captopril were studied. Electrochemical impedance spectroscopy was used to study the charge transfer properties at the electrode–solution interface. Finally, the sensor was examined as a selective, simple, and precise new electrochemical sensor for the determination of captopril in real samples, such as drug and urine, with satisfactory results.  相似文献   

6.
The electrocatalytic oxidation of glutathione (GSH) has been studied at the surface of ferrocene-modified carbon paste electrode (FMCPE). Cyclic voltammetry (CV), double potential step chronoamperometry, and differential pulse voltammetry (DPV) techniques were used to investigate the suitability of incorporation of ferrocene into FMCPE as a mediator for the electrocatalytic oxidation of GSH in buffered aqueous solution. Results showed that pH 7.00 is the most suitable for this purpose. In the optimum condition (pH 7.00), the electrocatalytic ability of about 480 mV can be found and the heterogeneous rate constant of catalytic reaction was calculated as . Also, the diffusion coefficient of glutathione, D, was found to be 3.61 × 10–5 cm2 s−1. The electrocatalytic oxidation peak current of glutathione at the surface of this modified electrode was linearly dependent on the GSH concentration and the linear analytical curves were obtained in the ranges of 3.2 × 10–5 M–1.6 × 10–3 M and 2.2 × 10–6 M–3.5 × 10–3 M with cyclic voltammetry and differential pulse voltammetry methods, respectively. The detection limits (3σ) were determined as 1.8 × 10–5 M and 2.1 × 10–6 M using CV and DPV, respectively. Finally, the electrocatalytic oxidation of GSH at the surface of this modified electrode can be employed as a new method for the voltammetric determination of glutathione in real samples such as human plasma.  相似文献   

7.
A kind of erbium hexacyanoferrate (ErHCF)-modified carbon ceramic electrodes (CCEs) fabricated by mechanically attaching ErHCF samples to the surface of CCEs derived from sol–gel technique was proposed. The resulting modified electrodes exhibit well-defined redox responses with the formal potential of +0.215 V [vs saturated calomel electrode (SCE)] at a scan rate of 20 mV s−1 in 0.5 M KCl (pH 7) solution. The voltammetric characteristics of the ErHCF-modified CCEs were investigated by voltammetry. Attractively, the ErHCF-modified CCEs presented good electrocatalytic activity with a marked decrease in the overvoltage about 400 mV for l-cysteine oxidation. The calibration plot for l-cysteine determination was linear at 5.0 × 10−6–1.3 × 10−4 M with a linear regression equation of I(A) = 0.558 + 0.148c (μM) (R 2 = 0.9989, n = 20), and the detection limit was 2 × 10−6 M (S/N = 3). At last, the ErHCF-modified CCEs were used for amperometric detection of l-cysteine in real samples.  相似文献   

8.
Polymerization of pyrrole and 2-aminobenzoic acid has been investigated, and a functionalized stable film of poly(pyrrole-2-aminobenzoic acid) (PP2ABA) has been obtained electrochemically onto platinum electrode. Different cyclic voltammetric behavior is obtained for polypyrrole and PP2ABA during electrosynthesis. Fourier-transformed infrared spectrometry and surface-enhanced Raman spectrometry measurements on the two films have confirmed the presence of carboxylate group in the films. The enzyme, glucose oxidase, was covalently immobilized on a conducting PP2ABA film, and amperometric response was measured as a function of concentration of glucose at a potential of 0.7 V vs Ag/AgCl in 0.1 M phosphate buffer at pH 6.2. The effect of polymeric film thickness, pH, and possible interferents were investigated. The linear range of the calibration curve is from 3 to 40 mM with a sensitivity of 0.058 μA mM−1 cm−2 and a limit of detection of 0.5 mM. The apperent Mishaelis–Menten constant K M is calculated to be 1 × 10−2 mM, and the response time is 5 s.  相似文献   

9.
A square wave adsorptive stripping voltammetric (SWAdSV) method was developed for the determination of proflavine. The electrochemical behaviour of proflavine was investigated by cyclic (CV) and square wave voltammetry (SWV) at the hanging mercury drop electrode (HMDE) and carbon paste electrode (CPE). Different parameters were tested to optimize the conditions of the determination. Better results were obtained by square wave voltammetry using CPE where two oxidation and a reduction peak, appeared, at 0.19, 0.94 and 0.20 V, respectively. The peak at 0.19 V is quasi-reversible and deposition dependent. Linearity was observed in the range of (0.2–23.4) × 10−8 M (r = 0.998) during the anodic scan and in the range of (1.17–117) × 10−8 M (r = 0.999) during the cathodic scan. The second peak at 0.94 V is irreversible and deposition independent. The linearity of this peak was observed in the range of (1.29–11.7) × 10−8 M (r = 0.998). The method was applied to the analysis of bovine serum and gave satisfactory results. Correspondence: S. Th. Girousi, Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University, Thessaloniki 54124, Greece  相似文献   

10.
The electrochemical behaviors of metol on an ionic liquid N-butylpyridinium hexafluorophosphate modified carbon paste electrode (IL-CPE) were studied in this paper. The results indicated that a pair of well-defined quasi-reversible redox peaks of metol appeared with the decrease of overpotential and the increase of redox peak current, which was the characteristics of electrocatalytic oxidation. The electrocatalytic mechanism was discussed and the electrochemical parameters were calculated with results of the charge-transfer coefficient (α) as 0.45, the electrode reaction rate constant (k s) as 4.02 × 10−3 s−1, and the diffusion coefficient (D) as 6.35 × 10−5 cm2/s. Under the optimal conditions, the anodic peak current was linear with the metol concentration in the range of 5.0 × 10−6 ∼ 1.0 × 10−3 mol/L (n = 11, γ = 0.994) and the detection limit was estimated as 2.33 × 10−6 mol/L (3σ). The proposed method was successfully applied to determination of metol content in synthetic samples and photographic solutions.  相似文献   

11.
The voltammetric behavior of strychnine has been studied with a pyrolytic graphite (PG) electrode. The redox process taking place at the PG electrode is discussed. The cyclic voltammetric response has also been evaluated with respect to various experimental conditions, such as scan rate, pH of the supporting electrolyte, strychnine concentrations and accumulation time. A highly sensitive voltammetric method for the determination of strychnine is consequently developed. The linear calibration is in the range of 1×10−6 M – 1.1×10−4 M, with the limit of detection (LOD) being 1×10−8 M. The precision is excellent with a relative standard deviation (RSD) of 2.3%. The proposed cyclic voltammetric methodology has been applied to the determination of strychnine in the extract of Strychno nux-vomica seeds using the standard addition method. Consistent results have been obtained from both the electrochemical approach described here and the previously reported HPLC method.  相似文献   

12.
A novel procedure was developed for the determination of trace cerium on the basis of anodic adsorption voltammetry of the Ce(III)–alizarin complexon (ALC) complex at a carbon paste electrode (CPE). The procedure is convenient to determine cerium individually in the presence of other rare earths because there is a 100 mV difference between the peak potentials of Ce(III)–ALC and other rare earth(III)–ALC complexes in a supporting electrolyte of 0.08 M HAc–NaAc and 0.012 M potassium biphthalate (pH 4.7) when performing linear-scanning from −0.2 to 0.8 V (vs. SCE) at 100 mV/s. The second-order derivative peak currents are directly proportional to the Ce(III) concentration over a range of 6.0 × 10−9–3.0 × 10−7 M. The detection limit is as low as 2.0 × 10−9 M (S/N = 3) for a 120 s preconcentration. An RSD of 3.5% was obtained for 15 determinations of Ce(III) at a concentration of 4.0 × 10−8 M on the same CPE surface. The method was applied successfully to the determination of cerium in samples of rare earth nodular graphite cast iron.  相似文献   

13.
The voltammetric behavior of tannic acid (TA) on a single-wall carbon nanotubes (SWNTs) modified glassy carbon electrode has been investigated by cyclic voltammetry. TA can generate a well-defined anodic peak on the modified electrode at around 0.42 V (vs. SCE) in 0.10 M phosphate buffer solutions (pH = 4.0). The electrochemical reaction involves 1e transfer, accompanied by one proton. The electrode process is controlled by adsorption. The parameters affecting the response of TA, such as solution pH, accumulation time and accumulation potential are optimized for the determination of TA. Under the optimum conditions, the peak current changes linearly with the TA concentration in the range of 5.0 × 10−8–1.0 × 10−6 M. The lowest detectable concentration of TA is 8.0 × 10−9 M after 180 s accumulation. This method has been successfully applied to the determination of TA in tea and beer samples. In addition, the influence of potential interferents is examined. In the presence of bovine serum albumin, the peak current of TA decreases linearly due to the formation of a super-molecular complex.  相似文献   

14.
Molecular wires containing copper(II) (CuMW), in the form of the coordination polymer (Cu(II)4(bpp)4(maa)8(H2O)2).2H2O (bpp=1,3-bis(4-pyridyl)propane, maa=2-methylacrylic acid), and multiwalled carbon nanotubes (CNT) have been combined to prepare a paste electrode (CuMW/CNT/PE). The voltammetric response of the CuMW/CNT/PE to metformin (MET) was significantly greater than that of electrodes prepared from other materials, because of both the surface effect of CuMW and CNT and coordination of MET with the Cu(II) ion in the CuMW. A novel voltammetric method for determination of MET is proposed. In pH 7.2 Britton–Robinson buffer, using single sweep voltammetry, the second-order derivative peak current for oxidation of MET at 0.97 V (relative to SCE) increased linearly with MET concentration in the range 9.0 × 10−7–5.0 × 10−5 mol L−1 and the detection limit was 6.5 × 10−7 mol L−1. Figure When a combination of molecular wires containing copper(II) (CuMW) and multiwalled carbon nanotubes (CNT) was used to prepare a paste electrode (CuMW/CNT/PE) the voltammetric response to metformin (curve c) was significantly higher than that at a carbon/PE (curve a) or a CNT/PE (curve b), because of the amplification effect of CNT and CuMW. A novel voltammetric method is proposed for determination of MET  相似文献   

15.
A highly sensitive hydroxylamine (HA) electrochemical sensor is developed based on electrodeposition of gold nanoparticles with diameter of 8 nm on the pre-synthesized polypyrrole matrix and formed gold nanoparticles/polypyrrole (GNPs/PPy) composite on glassy carbon electrode. The electrochemical behavior and electrocatalytic activity of the composite-modified electrode are investigated. The GNPs/PPy composite exhibits a distinctly higher electrocatalytic activity for the oxidation of HA than GNPs with twofold enhancement of peak current. The enhanced electrocatalytic activity is attributed to the synergic effect of the highly dispersed gold metal particles and PPy matrix. The overall numbers of electrons involved in HA oxidation, the electron transfer coefficient, catalytic rate constant, and diffusion coefficient are investigated by chronoamperometry. The sensor presents two wide linear ranges of 4.5 × 10−7–1.2 × 10−3 M and 1.2 × 10−3–19 × 10−3 M with the detection limit of 4.5 × 10−8 M (s/n = 3). In addition, the proposed electrode shows excellent sensitivity, selectivity, reproducibility, and stability properties.  相似文献   

16.
Simple and sensitive electrochemical method for the determination of nitrite, based on a nano-alumina-modified glassy carbon electrode (GCE), is described. Nitrite yields a well-defined oxidation peak whose potential is 0.74 V at the nano-alumina-coated GCE in 0.1 mol L−1 phosphate buffer (pH 5.0). Compared with bare GCE, the nano-alumina-modified GCE has evident catalytic effect towards the oxidation of nitrite, and its peak current can be significantly enhanced. Some of the experimental parameters were optimized for the determination of nitrite. The oxidation peak current was proportional to nitrite concentration in the range of 5.0 × 10−8–1.1 × 10−3 mol L−1, and a detection limit of 1.0 × 10−8 mol L−1 was obtained. This method has been successfully used to the determination of nitrite in sausage sample. Furthermore, results obtained by the method have been compared with spectrophotometric method.  相似文献   

17.
 The construction of a plasticised PVC matrix-type promazinium cation-selective membrane electrode and its use in the potentiometric determination of promazine hydrochloride in pharmaceutical preparations are described. It is based on the use of the ion-associate species, formed by promazinium cation and tetraphenylborate (TPB) counter ion. The basic electrode performance characteristics are evaluated according to IUPAC recommendations. It exhibited a linear response for 1 × 10−2−1 × 10−5 M of promazine hydrochloride solutions with a cationic Nernstian slope over the pH range 2–6. Common organic and inorganic cations showed negligible interference. Direct potentiometric determination of 1 × 10−2−1 × 10−5 M aqueous promazine hydrochloride using this membrane electrode system showed an average recovery of 99.5% with a mean standard deviation of 1.5%. This electrode was successfully used for monitoring the titration of promazine hydrochloride with sodium tetraphenyl borate and for determining promazine hydrochloride in ampoules. Received June 15, 2001 Revision November 6, 2001  相似文献   

18.
A sensitive adsorptive anodic stripping procedure for the determination of trace zirconium at a carbon paste electrode (CPE) has been developed. The method is based on adsorptive accumulation of the Zr(IV)-alizarin red S(ARS) complex onto the surface of the CPE, followed by oxidation of adsorbed species. The optimal experimental conditions include the use of 0.10 mol · L−1 ammonium acetate buffer (pH 4.3), ARS, an accumulation potential of 0.20 V (versus SCE), an accumulation time of 2 min, a scan rate of 200 mV · s−1 and a second-order derivative linear scan mode. The oxidation peak for the complex appears at 0.69 V. The peak current is proportional to the concentration of Zr(IV) over the range of 1.0 × 10−9–2.0 × 10−7 mol · L−1, and the detection limit is 3 × 10−10 mol · L−1 for a 2 min adsorption time. The relative standard deviations (n = 8) for 5.0 × 10−8 and 5.0 × 10−9 mol · L−1 Zr(IV) are 3.3 and 4.8%, respectively. The proposed method was applied to the determination of zirconium in ore samples with satisfactory results.  相似文献   

19.
A single optosensing device based on lanthanide-sensitized luminescence was developed for determination of p-aminobenzoic acid (PABA). The method is based on the formation of a complex between PABA and Tb(III) immobilized on the solid phase (QAE A-25 resin) placed inside the flow cell. NaCl (1 M) was used as carrier solution and HCl (0.05 M) as eluent. The sample solutions of PABA (100 μL) containing Tb(III) and buffered at pH = 6.0 were injected into the carrier stream and the luminescence was measured at λ ex = 290 nm and λ em = 546 nm. The method shows a linear range from 0.2 to 6.0 μg mL−1 with an RSD of 1.2% (n = 10) and a sampling frequency of 22 h−1. A remarkable characteristic of the method is its high selectivity which allows it to be satisfactorily applied to the analysis of PABA in pharmaceutical samples without prior treatment. Figure Typical emission bands of Tb(III) in a solid-phase PABA–Tb(III) luminescence spectrum  相似文献   

20.
A pencil graphite electrode coated by copper (II)–carmoisine dye complex in polyaniline (emeraldine base form) matrix (termed as PGE/PA/Cu-Car) was prepared and used as copper ion-selective electrode. The introduced electrode was found to have high selectivity toward copper ion (II) and exhibited wide working concentration range, low response time, and good shelf life. The sensor electrode showed a linear Nernstian response over the range of 5.0 × 10−6 to 1.0 × 10−1 M with a slope of 29.7 ± 1 mV per decade change in concentration. A detection limit of 2.0 × 10−6 M was obtained. The optimum pH working range of the electrode was found to be 4.0–7.0.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号