首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
The voltammetric determination of synthetic antioxidant 2,6‐di‐tert‐butyl‐4‐methylphenole (BHT) was studied using linear‐sweep voltammetry (LSV) and cyclic voltammetry (CV) with a gold electrode and performed in isopropanol media containing either 0.1 mol L?1 H2SO4 or 0.1 mol L?1 LiClO4 as supporting electrolyte. The results obtained have revealed that the most reliable detection was acquired in acidic media (isopropanol–H2SO4) whereas the use of isopropanol? LiClO4 solution exhibited poorer reproducibility due to possible passivation of the electrode. Real samples of biodiesel mixture were analyzed without any special sample treatment or separation and results were compared with those obtained by FTIR‐spectroscopy.  相似文献   

2.
《Electroanalysis》2006,18(23):2337-2342
The voltammetric behavior of α‐tocopherol in the presence of vegetable oil is studied at a polypyrrole modified Pt electrode in a 1,2‐dichloroethane‐ethanol medium with cyclic voltammetry. Cyclic voltammogram of α‐tocopherol showed a well‐defined oxidation peak; the peak potential shifting toward less positive and a much higher peak current obtained at a polypyrrole modified electrode than that obtained at the unmodified Pt electrode. An electroanalytical method for the determination of α‐tocopherol based on its electrochemical oxidation at the polypyrrole modified Pt electrode is developed. Using differential pulse voltammetry, the peak currents were found to increase linearly with the α‐tocopherol concentration over the range of 5.0 to 300 μM, with a sensitivity of 5.38×10?2 A L mol?1 and the limit of detection of 1.5 μM (S/N=3), the detection time being about 90 s for each assay. The interference of other synthetic antioxidants such as TBHQ, BHA and BHT to the analysis of α‐tocopherol was investigated. The developed method is applied to the quantification of tocopherols in six vegetable oils, showing that the results are in good agreement with those by HPLC method.  相似文献   

3.
The electrochemical properties of hydrazine studied at the surface of a carbon paste electrode spiked with p‐bromanil (tetrabromo‐p‐benzoquinone) using cyclic voltammetry (CV), double potential‐step chronoamperometry and differential pulse voltammetry (DPV) in aqueous media. The results show this quinone derivative modified carbon paste electrode, can catalyze the hydrazine oxidation in an aqueous buffered solution. It has been found that under the optimum conditions (pH 10.00), the oxidation of hydrazine at the surface of this carbon paste modified electrode occurs at a potential of about 550 mV less positive than that of a bar carbon paste electrode. The electrocatalytic oxidation peak current of hydrazine showed a linear dependent on the hydrazine concentrations and linear analytical curves were obtained in the ranges of 6.00×10?5 M–8.00×10?3 M and 7.00×10?6 M–8.00×10?4 M of hydrazine concentration with CV and differential pulse voltammetry (DPV) methods, respectively. The detection limits (3σ) were determined as 3.6×10?5 M and 5.2×10?6 M by CV and DPV methods. This method was also used for the determination of hydrazine in the real sample (waste water of the Mazandaran wood and paper factory) by standard addition method.  相似文献   

4.
《Electroanalysis》2006,18(17):1722-1726
The electrochemical properties of L ‐cysteic acid studied at the surface of p‐bromanil (tetrabromo‐p‐benzoquinone) modified carbon paste electrode (BMCPE) in aqueous media by cyclic voltammetry (CV) and double step potential chronoamperometry. It has been found that under optimum condition (pH 7.00) in cyclic voltammetry, the oxidation of L ‐cysteic acid at the surface of BMCPE occurs at a half‐wave potential of p‐bromanil redox system (e.g., 100 mV vs. Ag|AgCl|KClsat), whereas, L ‐cysteic acid was electroinactive in the testing potential ranges at the surface of bare carbon paste electrode. The apparent diffusion coefficient of spiked p‐bromanil in paraffin oil was also determined by using the Cottrell equation. The electrocatalytic oxidation peak current of L ‐cysteic acid exhibits a linear dependency to its concentration in the ranges of 8.00×10?6 M–6.00×10?3 M and 5.2×10?7 M–1.0×10?5 M using CV and differential pulse voltammetry (DPV) methods, respectively. The detection limits (2σ) were determined as 5.00×10?6 M and 4.00×10?7 M by CV and DPV methods. This method was used as a new, selective, rapid, simple, precise and suitable voltammetric method for determination of L ‐cysteic acid in serum of patient's blood with migraine disease.  相似文献   

5.
《Electroanalysis》2006,18(12):1193-1201
A chemically modified carbon paste electrode with 2,7‐bis(ferrocenyl ethyl)fluoren‐9‐one (2,7‐BFEFMCPE) was employed to study the electrocatalytic oxidation of ascorbic acid in aqueous solution using cyclic voltammetry, differential pulse voltammetry and chronoamperometry. The diffusion coefficient (D=1.89×10?5 cm2 s?1), and the kinetic parameter such as the electron transfer coefficient, α (=0.42) of ascorbic acid oxidation at the surface of 2,7‐BFEFMCPE was determined using electrochemical approaches. It has been found that under an optimum condition (pH 7.00), the oxidation of ascorbic acid at the surface of such an electrode occurs at a potential about 300 mV less positive than that of an unmodified carbon paste electrode. The catalytic oxidation peak currents show a linear dependence on the ascorbic acid concentration and linear analytical curves were obtained in the ranges of 8.0×10?5 M–2.0×10?3 M and 3.1×10?5 M–3.3×10?3 M of ascorbic acid with correlation coefficients of 0.9980 and 0.9976 in cyclic voltammetry and differential pulse voltammetry, respectively. The detection limits (2δ) were determined to be 2.9×10?5 M and 9.0×10?6 M with cyclic voltammetry and differential pulse voltammetry, respectively. This method was also examined for determination of ascorbic acid in pharmaceutical preparations.  相似文献   

6.
A carbon paste electrode spiked with 1‐[4‐ferrocenyl ethynyl) phenyl]‐1‐ethanone (4FEPE) was constructed by incorporation of 4FEPE in graphite powder‐paraffin oil matrix. It has been shown by direct current cyclic voltammetry and double step chronoamperometry that this electrode can catalyze the oxidation of tryptophan (Trp) in aqueous buffered solution. It has been found that under optimum condition (pH 7.00), the oxidation of Trp at the surface of such an electrode occurs at a potential about 200 mV less positive than at an unmodified carbon paste electrode. The kinetic parameters such as electron transfer coefficient, α and rate constant for the chemical reaction between Trp and redox sites in 4FEPE modified carbon paste electrode (4FEPEMCPE) were also determined using electrochemical approaches. The electrocatalytic oxidation peak current of Trp showed a linear dependent on the Trp concentrations and linear calibration curves were obtained in the ranges of 6.00×10?6 M–3.35×10?3 M and 8.50×10?7 M–6.34×10?5 M of Trp concentration with cyclic voltammetry (CV) and differential pulse voltammetry (DPV) methods, respectively. The detection limits (3σ) were determined as 1.80×10?6 M and 5.60×10?7 M by CV and DPV methods. This method was also examined as a selective, simple and precise new method for voltammetric determination of tryptophan in real sample.  相似文献   

7.
The electrochemical behavior of L ‐cysteine studied at the surface of ferrocenedicarboxylic acid modified carbon paste electrode (FDCMCPE) in aqueous media using cyclic voltammetry, differential pulse voltammetry and double potential step chronoamperometry. It has been found that under optimum condition (pH 8.00) in cyclic voltammetry, the oxidation of L ‐cysteine occurs at a potential about 200 mV less positive than that of an unmodified carbon paste electrode. The kinetic parameters such as electron transfer coefficient, α, and catalytic reaction rate constant, kh were also determined using electrochemical approaches. The electrocatalytic oxidation peak current of L ‐cysteine showed a linear dependent on the L ‐cysteine concentration and linear analytical curves were obtained in the ranges of 3.0×10?5 M–2.2×10?3 M and 1.5×10?5 M–3.2×10?3 M of L ‐cysteine concentration with cyclic voltammetry (CV) and differential pulse voltammetry (DPV) methods respectively. The detection limits (3σ) were determined as 2.6×10?5 M and 1.4×10?6 M by CV and DPV methods.  相似文献   

8.
High intensity microwave radiation effects are demonstrated for electron transfer processes at 25 or 50-μm diameter platinum electrodes immersed in micellar sodium dodecylsulfate (SDS) solutions. First, a solution containing 2 mM Fe(CN)63− and 2 mM Fe(CN)64− in aqueous 0.1 M NaCl with and without SDS is employed to calibrate the electrode temperature and mass transport conditions. Addition of 0.1 M SDS has only a small effect on the microwave enhanced voltammetry for the Fe(CN)63-/4− system. Next, two highly water-insoluble redox systems are studied. A solution of 1 mM tert-butylferrocene in aqueous 0.1 M NaCl containing 0.1 M SDS is shown to give no current response in the absence of microwaves. In the presence of focused microwaves at a platinum disc electrode, a strong current for the one electron oxidation of tert-butylferrocene is detected presumably due to localized disruption of the micellar solution. Concentrations of tert-butylferrocene down to the micromolar level are detected. α-Tocopherol, a lipophilic vitamin and antioxidant, is soluble in aqueous 0.1 M SDS/0.1 M NaCl. In the presence of microwave radiation, a strong and concentration dependent anodic current response consistent with the two-electron oxidation of α-tocopherol is observed. A heptode array of seven individual 50 μm diameter platinum microelectrodes placed in ca. 720 μm distance of each other is shown to allow microwave enhanced currents to be increased sevenfold with each electrode exhibiting the same microwave effect.  相似文献   

9.
《Electroanalysis》2005,17(19):1740-1745
A p‐chloranil modified carbon paste electrode was constructed and the electrochemical behavior of this electrode was studied in the aqueous solution with different pH. From the E1/2–pH diagram for this compound the values of formal potential E0' and pKa of some different redox and acid‐base couples depending on the solution pH were estimated. The diffusion coefficient, D, value for p‐chloranil was estimated 1.5×10?7 cm2 s?1. It has been shown by direct current cyclic voltammetry and double potential step chronoamperometry, that this p‐chloranil incorporated carbon paste electrode, can catalyze the oxidation of ascorbic acid in the aqueous buffered solution. Under the optimum condition (pH 7.00), the oxidation of ascorbic acid at the surface of such an electrode occurs at a potential about 325 mV less positive than that at an unmodified carbon past electrode. The catalytic oxidation peak currents was linearly dependent on the ascorbic acid concentration and a linear calibration curve was obtained in the range of 7×10?5 M–4×10?3 M of ascorbic acid with a correlation coefficient of 0.9998. The limit of detection (3σ) was determined as 3.5×10 ?5 M. This method was used as simple, selective and precise voltammetric method for determination of ascorbic acid in pharmaceutical preparations.  相似文献   

10.
A novel carbon paste electrode modified with carbon nanotubes and 5‐amino‐2′‐ethyl‐biphenyl‐2‐ol (5AEB) was fabricated. The electrochemical study of the modified electrode, as well as its efficiency for electrocatalytic oxidation of levodopa (LD) and carbidopa (CD), is described. Cyclic voltammetry (CV) was used to investigate the redox properties of this modified electrode at various scan rates. The apparent charge transfer rate constant, ks, and transfer coefficient, a, for electron transfer between 5AEB and CPE were calculated as 17.3 s?1 and 0.5, respectively. Square wave voltammetry (SWV) exhibits a linear dynamic range from 2.5×10?7 to 2.0×10?4 M and a detection limit of 9.0×10?8 M for LD.  相似文献   

11.
We studied sensor application of a graphene oxide and hematite (α‐Fe2O3/GO) composite electrode well‐characterized by the SEM and XRD. Through differential pulse voltammetry (DPV), oxidation of dexamethasone sodium phosphate (DSP) was studied at the surface of a glassy carbon electrode (GCE) modified with graphene oxide nanosheets (GO) and the α‐Fe2O3/GO composite. The values of the transfer coefficient (α) and the diffusion coefficient (D) of DSP were 0.5961 and 4.71×10?5 cm2 s?1 respectively. In the linear range of 0.1–50 μM, the detection limit (DL) was 0.076 μM. In the second step, a GCE was modified with α‐Fe2O3/GO composite and the DSP measurement step was repeated to analyzed and compare the effects of hematite nanoparticles present on graphene oxide surfaces. According to the results, α and D were 0.52 and 2.406×10?4 cm2 s?1 respectively and the DL was 0.046 μM in the linear range of 0.1–10.0 μM. The sensor is simple, inexpensive and uses blood serum.  相似文献   

12.
A new modified carbon‐ceramic electrode was prepared by incorporating TiO2 nanoparticle into sol‐gel network by accompanying apple tissue. A mixture of fine graphite powder with 15 wt% of TiO2 nanoparticle was used for the preparation of the carbon matrix and finally modification with a known amount weighted of apple tissue. The apple tissue containing polyphenol oxidase enzyme acts as molecular recognition element. The electrocatalytic oxidation of dopamine was investigated on the surface of the nanobiocomposite modified carbon‐ceramic electrode using cyclic voltammetry, chronoamperometry and amperometry techniques. Effect of pH, scan rate, TiO2 percentage on the response of modified electrode was studied. The prepared modified electrode presented a linear range for dopamine from 5.0×10?6 to 1.2×10?3 M in buffered solutions with pH 7.4 by amperometry. The detection limit was 3.41×10?6 M dopamine. The response of the modified carbon‐ceramic electrode and unmodified carbon‐ceramic electrode was compared.  相似文献   

13.
A micellar electrokinetic capillary chromatography method with electrochemical detection (MECC‐ED) has been developed for the simultaneous determination of eight phenolic additives, including propyl gallate (PG), tert‐butylhydroquinone (TBHQ), butylated hydroxyanisole (BHA), butylated hydroxytoluene (BHT), methylparaben (MP), ethylparaben (EP), propylparaben (PP) and butylparaben (BP) in cosmetic products. Method development involved optimization of the working electrode, the pH value of running buffer, the concentration of sodium dodecyl sulfate (SDS), the separation voltage, and the sample injection time. Under the optimum conditions, all analytes can be well separated within 26 min at the separation voltage of 18 kV in a 9 mmol·L?1 sodium dodecyl sulfate (SDS) ?60 mmol·L?1 borate running buffer (pH 8.0). A 300 μm diameter carbon disk electrode generated good response at +0.90 V (vs. SCE) for all analytes. Linearity of the present method was over three orders of magnitude of analyte concentration with detection limits (S/N=3) ranging from 1.1×10?7 to 1.2×10?6 g·mL?1 for all analytes. This proposed method has been successfully applied to the simultaneous determination of the above additives in commercial cosmetics, and the assay results were satisfactory.  相似文献   

14.
《Analytical letters》2012,45(9):1763-1778
Abstract

Direct electrochemistry of alpha‐lipoic acid (ALA) was performed at a glassy carbon electrode using cyclic, differential pulse and square wave voltammetry over a wide range of pH. The oxidation of ALA is an irreversible process, pH independent, and involves the charge transfer of one electron. The diffusion coefficient of ALA was calculated from the results obtained at pH 6.9 in 0.1 M phosphate buffer and was shown to be D 0=1.1×10?5 cm2 s?1. The limits of detection (LOD) and quantification (LOQ) calculated from the results obtained at this pH are 1.8 and 6.1 µM, respectively.

The lipoic acid content in two dietary supplements samples, a syrup containing ALA and capsules of ALA, has been determined directly at the glassy carbon electrode by differential pulse voltammetry using the standard addition method.  相似文献   

15.
A sensitive voltammetric technique has been developed for the determination of Fludarabine using amine‐functionalized multi walled carbon nanotubes modified glassy carbon electrode (NH2‐MWCNTs/GCE). Molecular dynamics simulations, an in silico technique, were employed to examine the properties including chemical differences of Fludarabine‐ functionalized MWCNT complexes. The redox behavior of Fludarabine was examined by cyclic, differential pulse and square wave voltammetry in a wide pH range. Cyclic voltammetric investigations emphasized that Fludarabine is irreversibly oxidized at the NH2‐MWCNTs/GCE. The electrochemical behavior of Fludarabine was also studied by cyclic voltammetry to evaluate both the kinetic (ks and Ea) and thermodynamic (ΔH, ΔG and ΔS) parameters on NH2‐MWCNTs/GCE at several temperatures. The mixed diffusion‐adsorption controlled electrochemical oxidation of Fludarabine revealed by studies at different scan rates. The experimental parameters, such as pulse amplitude, frequency, deposition potential optimized for square‐wave voltammetry. Under optimum conditions in phosphate buffer (pH 2.0), a linear calibration curve was obtained in the range of 2×10?7 M–4×10?6 M solution using adsorptive stripping square wave voltammetry. The limit of detection and limit of quantification were calculated 2.9×10?8 M and 9.68×10?8 M, respectively. The developed method was applied to the simple and rapid determination of Fludarabine from pharmaceutical formulations.  相似文献   

16.
《Electroanalysis》2004,16(10):860-865
The electrocatalytic oxidation of sulfite has been studied on the cobalt pentacyanonitrosylferrate modified glassy carbon electrode (CoPCNF). The CoPCNF films on the glassy carbon electrodes show an excellent electrocatalytic activity toward the oxidation of sulfite in 0.5 M KNO3. The kinetics of the catalytic reaction was investigated by using cyclic voltammetry, rotating disk electrode (RDE) voltammetry and chronoamperometry. The average value of the rate constant, K, for the catalytic reaction and the diffusion coefficient, D, were evaluated by different approaches for sulfite and found to be 2.9×102 M?1s?1 and 4.6×10?6 cm2s?1, respectively. At a fixed potential under hydrodynamic conditions (stirred solutions), the oxidation current is proportional to the sulfite concentration and the calibration plot was linear over the concentration range 5×10?6–1×10?4 M. The detection limit of the method is 3×10?6 M., low enough for the trace sulfite determination.  相似文献   

17.
The electrocatalytic oxidation of hydrazine at a carbon paste electrode spiked with acetylferrocene as a mediator was studied by cyclic voltammetry, differential pulse voltammetry, and chronoamperometry. In contrast to other ferrocenic compounds, acetylferrocene exhibits a chemical irreversible behavior, but it can act as an effective mediator for electrocatalytic oxidation of hydrazine, too. The heterogeneous electron transfer rate constant between acetylferrocene and the electrode substrate (carbon paste) and the diffusion coefficient of spiked acetylferrocene in silicon oil were estimated to be about 3.45×10?4 cm s?1 and 4.45×10?9 cm2 s?1, respectively. It has been found that under the optimum conditions (pH 7.5) the oxidation of hydrazine occurs at a potential of about 228 mV less positive than that of an unmodified carbon paste electrode. The catalytic oxidation peak current of hydrazine was linearly dependent on its concentration and the obtained linear range was 3.09×10?5 M–1.03×10?3 M. The detection limit (2σ) has been determined as 2.7×10?5 M by cyclic voltammetry. Also, the peak current was increased linearly with the concentration of hydrazine in the range of 1×10?5 M–1×10?3 M by differential pulse voltammetry with a detection limit of 1×10?5 M. This catalytic oxidation of hydrazine has been applied as a selective, simple, and precise new method for the determination of hydrazine in water samples.  相似文献   

18.
The usefulness of a C60‐fullerene modified gold (Au) electrode in mediating the oxidation of methionine in the presence of potassium ions electrolyte has been demonstrated. During cyclic voltammetry, an oxidation peak of methionine appearing at +1.0 V vs. Ag/AgCl was observed. The oxidation current of methionine is enhanced by about 2 times using a C60 modified gold electrode. The current enhancement is significantly dependent on pH, temperature and C60 dosage. Calibration plot reveals linearity of up to 0.1 mM with a current sensitivity of close to 50 mA L mol?1 and detection limit of 8.2×10?6 M. The variation of scan rate study shows that the system undergoes diffusion‐controlled process. Diffusion coefficient and rate constant of methionine were determined using hydrodynamic method (rotating disk electrode) with values of 1.11×10?5 cm2 s?1 and 0.0026 cm s?1 respectively for unmodified electrode while the values of diffusion coefficient and rate constant of methionine using C60 modified Au electrode are 5.7×10?6 cm2 s?1 and 0.0021 cm s?1 respectively.  相似文献   

19.
《Electroanalysis》2005,17(22):2043-2051
The electrochemical behavior of L ‐cysteine studied at the surface of ferrocenecarboxylic acid modified carbon paste electrode (FCMCPE) in aqueous media using cyclic voltammetry and double step potential chronoamperometry. It has been found that under optimum condition (pH 7.00) in cyclic voltammetry, the oxidation of L ‐cysteine is occurs at a potential about 580 mV less positive than that an unmodified carbon paste electrode. The kinetic parameters such as electron transfer coefficient, α and catalytic reaction rate constant, Kh were also determined using electrochemical approaches. The electrocatalytic oxidation peak current of L ‐cysteine showed a linear dependent on the L ‐cysteine concentration and linear calibration curves were obtained in the ranges of 10?5 M–10?3 M and 4.1×10?8 M–3.7×10?5 M of L ‐cysteine concentration with cyclic voltammetry (CV) and differential pulse voltammetry (DPV) methods respectively. The detection limits (2δ) were determined as 2.4×10?6 M and 2.5×10?8 M by CV and DPV methods. This method was also examined for determination of L ‐cysteine in some samples, such as Soya protein powder, serum of human blood by using recovery and standard addition methods.  相似文献   

20.
《Electroanalysis》2004,16(24):2051-2057
A conducting polymer was electrochemically prepared on a Pt electrode with newly synthesized 3′‐(4‐formyl‐3‐hydroxy‐1‐phenyl)‐5,2′ : 5′,2″‐terthiophene (FHPT) in a 0.1 M TBAP/CH2Cl2 solution. The polymer‐modified electrode exhibited a response to proton and metal ions, especially Al(III) ions. The poly[FHPT] was characterized with cyclic voltammetry, EQCM, and applied to the analysis of trace levels of Al(III) ions. Experimental parameters affecting the response of the poly[FHPT] were investigated and optimized. Other metal ions in low concentration did not interfere with the analysis of Al(III) ions in a buffer solution at pH 7.4. The response was linear over the concentration range of 5.0×10?8–7.0×10?10 M, and the detection limit was 5.0×10?10 M using the linear sweep voltammetry (LSV). Employing the differential pulse voltammetry (DPV), the response was linear over the 1.0×10?9–5.0×10?11 M range and the detection limit was 3.0×10?11 M. The relative standard deviation at 5.0×10?11 M was 7.2% (n=5) in DPV. This analytical method was successfully verified for the analysis of trace amounts of Al(III) ions in a human urine sample.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号