首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Inorganic arsenic (As) displays extreme toxicity and is a class A human carcinogen. It is of interest to both analytical chemists and environmental scientists. Facile and sensitive determination of As and knowledge of the speciation of forms of As in aqueous samples are vitally important. Nearly every nation has relevant official regulations on permissible limits of drinking water As content. The size of the literature on As is therefore formidable. The heart of this review consists of two tables: one is a compilation of principal official documents and major review articles, including the toxicology and chemistry of As. This includes comprehensive official compendia on As speciation, sample treatment, recommended procedures for the determination of As in specific sample matrices with specific analytical instrument(s), procedures for multi-element (including As) speciation and analysis, and prior comprehensive reviews on arsenic analysis. The second table focuses on the recent literature (2005–2013, the coverage for 2013 is incomplete) on As measurement in aqueous matrices. Recent As speciation and analysis methods based on spectrometric and electrochemical methods, inductively coupled plasma-mass spectrometry, neutron activation analysis and biosensors are summarized. We have deliberately excluded atomic optical spectrometric techniques (atomic absorption, atomic fluorescence, inductively coupled plasma-optical emission spectrometry) not because they are not important (in fact the majority of arsenic determinations are possibly carried out by one of these techniques) but because these methods are sufficiently mature and little meaningful innovation has been made beyond what is in the officially prescribed compendia (which are included) and recent reviews are available.  相似文献   

2.
Vanadium is recognized worldwide as the most abundant metallic constituent in petroleum. It is causing undesired side effects in the refining process, and corrosion in oil-fired power plants. Consequently, it is the most widely determined metal in petroleum and its derivatives. This paper offers a critical review of analytical methods based on atomic spectrometric techniques, particularly flame atomic absorption spectrometry (FAAS), electrothermal atomic absorption spectrometry (ET AAS), inductively coupled plasma optical emission spectrometry (ICP OES), inductively coupled plasma mass spectrometry (ICP-MS). In addition an overview is provided of the sample pretreatment and preparation procedures for vanadium determination in petroleum and petroleum products. Also included are the most recent studies about speciation and fractionation analysis using atomic spectrometric techniques.  相似文献   

3.
Performances of two atomic detectors, Inductively Coupled Plasma-Mass Spectrometry (ICP-MS) and Atomic Fluorescence Spectrometry (AFS) have been compared for arsenic speciation in environmental samples. Instrumental couplings, based on the use of high performance liquid chromatography (HPLC), hydride generation (HG), and the two atomic detectors were used for the speciation of arsenite, arsenate, dimethylarsinic acid and monomethylarsonic acid. Optionally, arsenobetaine was also determined using on-line ultraviolet (UV) photooxidation. The detection limits ranging from 0.1 to 0.3 mug l(-1) (as As) and the precision >10% RSD obtained with HPLC-(UV)-HG-AFS were comparable with those obtained with HPLC-(UV)-HG-ICP-MS. Both instrumental coupling were applied to the NRCC-TORT-1 and several environmental samples, such as seawater, freshwater, sediments, bivalves and bird eggs, taken from two areas with different degrees of pollution. No influence of the sample matrix was observed on the results using external calibration and standard additions methods, for both coupled techniques.  相似文献   

4.
Mercury and arsenic are two elements of undoubted importance owing to their toxic character. Although speciation of these elements has been developed separately, in this work for the first time the speciation of As and Hg using two atomic fluorescence detectors in a sequential ensemble is presented. A coupling based on the combination of high-performance liquid chromatography (where mercury and arsenic species are separated) and two atomic fluorescence detectors in series, with several online treatments, including photooxidation (UV) and hydride generation, has allowed the determination of mercury and arsenic compounds simultaneously. The detection limits for this device were 16, 3, 17, 12 and 8 ng mL–1 for AsIII, monomethylarsinic acid, AsV, Hg2+ and methylmercury, respectively. This coupling was compared with an analogous one based on inductively coupled plasma–mass spectrometry (ICP-MS) detection, with detection limits of 0.7, 0.5, 0.8, 0.9 and 1.1 ng mL–1, respectively. Multispeciation based on ICP-MS exhibits better sensitivity than the coupling based on tandem atomic fluorescence, but this second device is a very robust system and exhibits obvious advantages related to the low cost of acquisition and maintenance, as well as easy handling, which makes it a suitable system for routine laboratories.  相似文献   

5.
Burguera M  Burguera J 《Talanta》1997,44(9):1581-1604
A literature search on the speciation of arsenic in environmental and biological samples shows an increasing interest of many researchers in the subject. Because of the low level of arsenic species in real samples, many problems related with its speciation remain unresolved: species instability during sampling, storage and sample treatment, incomplete recovery of all species, matrix interferences, lack of appropriate certified reference materials and of sensitive analytical methods, etc. These aspects are underlined in this paper. The continued development of new analytical procedures pretending to solve some of these problems claim for an up-to-date knowledge of the recent publications. Therefore, this paper pretends to review the latest publications on the chemical speciation of arsenic, emphasizing the increasing activity in the development of accurate and precise analytical methods. In most of the cases, separation and preconcentration is necessary, followed by element-specific detection for sensitivity improvement. Hydride generation following separation procedures (e.g., ion-exchange or high performance liquid chromatography) coupled to atomic absorption or atomic emission detectors proved to have sufficient sensitivity to monitor arsenic exposure, although restricts the analysis to hydride-forming species. Modified procedures including some kind of heating in the presence of highly oxidizing agents have proved successful to completely decompose the arsenic containing compounds to arsenate and so to extend the range of compounds which can be determined by these methods. On-line arrangements have the additional advantage of avoiding excessive sample handling, although some of them involve numerous steps and others are too costly to be recommended for routine use. The analytical figures of merits, specially detection limits are given for most of the methods in order to afford comparison and judge possible applicability. These studies, which have been approached in many different ways, would lead to knowledge that are determinant in the understanding of the cycle of this element in environment and of its physiological and toxicological behavior in the living organisms.  相似文献   

6.
In the past decade, the lab-on-valve (LOV) system, as the third-generation of the flow-injection analysis technique, has exhibited powerful capability in instrument miniaturization and on-line sample pretreatment.This review presents and discusses the state of the art in the progress of the LOV system in the determination of metal species in two parts:
miniaturization of analytical instrumentations; and,
sample-processing front-ends.
As a miniaturized analytical set-up, LOV incorporates detection techniques for the determination of metal species (e.g., spectrophotometry, electrochemical detection and atomic spectrometry). However, coupling LOV sample pretreatment with atomic or mass spectrometric detectors provides high-sensitivity determination or speciation of metal species.We also discuss future perspectives of the LOV system in metal determination and/or speciation.  相似文献   

7.
Abstract

Kinetic studies of uptake of metal ions by the Chelex batch technique were made to determine Cd, Cu and Pb speciation in model solutions, a snow sample and a river surface water sample. Inductively-coupled plasma mass spectrometry (ICP-MS) and graphite furnace atomic absorption spectrometry (GFAAS) were used for direct determination of these metals. ICP-MS with the solution nebulization technique minimized contamination and adsorption problems involved in the discrete sampling technique of GFAAS, and hence, gave more precise and accurate results. Also, ICP-MS allowed collection of many more data points than GFAAS and was able to resolve components with similar rates of dissociation, which could not always be resolved by GFAAS with its discrete sampling technique. ICP-MS was therefore preferable to GFAAS for kinetic studies of metal speciation. The kinetic data were analyzed by the iterative deconvolution method. The applicability of the Chelex batch technique to metal speciation was validated by analysis of model solutions containing these metal ions with or without EDTA, NTA and fulvic acid. Use of the Chelex batch technique for Cd, Cu and Pb speciation in snow and river surface water samples revealed a number of kinetically distinguishable components of these metals (as complexes) ranging from one to three, probably present as aquo ions or inorganic complexes in the snow sample, and bound to macromolecules/and or colloidal materials in the river surface water sample.  相似文献   

8.
A simple and efficient method for separation and determination of inorganic arsenic (iAs) and organic arsenic (oAs) in drinking, natural and wastewater was developed. If arsenic is present in water prevailing forms are inorganic acids of As(III) and As(V). oAs can be found in traces as monomethylarsenic acid, MMA(V), and dimethylarsenic acid, DMAs(V). Three types of resins: a strong base anion exchange (SBAE) and two hybrid (HY) resins: HY-Fe and HY-AgCl, based on the activity of hydrated iron oxides and a silver chloride were investigated. It was found that the sorption processes (ion exchange, adsorption and chemisorptions) of arsenic species on SBAE (ion exchange) and HY resins depend on pH values of water. The quantitative separation of molecular and ionic forms of iAs and oAs was achieved by SBAE and pH adjustment, the molecular form of As(III) that exists in the water at pH <8.0 was not bonded with SBAE, which was convenient for direct determination of As(III) concentration in the effluent. HY-Fe resin retained all arsenic species except DMAs(V), which makes possible direct measurements of this specie in the effluent. HY-AgCl resin retained all iAs which was convenient for direct determination of oAs species concentration in the effluent. The selective bonding of arsenic species on three types of resins makes possible the development of the procedure for measuring and calculation of all arsenic species in water. In order to determine capacity of resins the preliminary investigations were performed in batch system and fixed bed flow system. Resin capacities were calculated according to breakthrough points in a fixed bed flow system which is the first step in designing of solid phase extraction (SPE) module for arsenic speciation separation and determination. Arsenic adsorption behavior in the presence of impurities showed tolerance with the respect to potential interference of anionic compounds commonly found in natural water. Proposed method was established performing standard procedures: with external standard, certified reference material and standard addition method. Two analytical techniques: the inductively coupled plasma mass spectrometry (ICP-MS) and atomic absorption spectroscopy-hydride generation (AAS-GH) were comparatively applied for the determination of arsenic in all arsenic species in water. ICP-MS detection limit was 0.2 μg L−1 and relative standard deviation (RSD) of all arsenic species investigated was between 3.5 and 5.1%.  相似文献   

9.
This review focuses on the determination of uranium using spectroanalytical techniques that are aimed at total determination such as flame atomic absorption spectrometry (FAAS), electrothermal atomic absorption spectrometry (ETAAS), inductively coupled plasma optical emission spectrometry (ICP-OES); and inductively coupled plasma mass spectrometry (ICP-MS) that also enables the determination of uranium isotopes. The advantages and shortcomings related to interferences, precision, accuracy, sample type and equipment employed in the analysis are taken into account, as well as the complexity and costs (i.e., acquisition, operation and maintenance) associated with each of the techniques. Strategies to improve their performance that employ separation and/or preconcentration steps are considered, with an emphasis given to solid-phase extraction because of its advantages compared to other preconcentration procedures.  相似文献   

10.
It is known that arsenic has different toxicological properties dependent upon both its oxidation state for inorganic compounds, as well as the different toxicity levels exhibited for organic arsenic compounds. The field of arsenic speciation analysis has grown rapidly in recent years, especially with the utilization of high-performance liquid chromatography (HPLC) coupled to inductively coupled plasma mass spectrometry (ICP-MS), a highly sensitive and robust detector system. Complete characterization of arsenic compounds is necessary to understand intake, accumulation, transport, storage, detoxification and activation of this element in the natural environment and living systems. This review describes the essential background and toxicity of arsenic in the environment, and more importantly, some currently used chromatographic applications and sample handling procedures necessary to accurately detect and quantify arsenic in its various chemical forms. Applications and work using only HPLC-ICP-MS for arsenic speciation of environmental and biological samples are presented in this review.  相似文献   

11.
An evolved-gas separation/flame Zeeman atomic absorption spectrometric approach is demonstrated for the speciation and determination of arsenic in oyster tissue. No digestion is needed and separation of inorganic arsenic compounds having similar boiling points is achieved. A stoichiometric or air-rich acetylene/air flame for atomic absorption spectrometry is not generally suitable for arsenic determination because of severe ultraviolet absorption interference at 193.7 nm and low sensitivity; polarized flame Zeeman atomic absorption spectrophotometry with a fuel-rich flame is suitable for the detection of traces of arsenic. The evolved-gas separation/Zeeman atomic absorption approach is simple, based on commercially available instrumentation, and useful for the selective determination of major arsenic compounds. Data are given to demonstrate optimal conditions and to show application to oyster tissue.  相似文献   

12.
Nowadays, reliable and robust detectors can be considered standard laboratory instrumentation, which, for most of the elements provide quantitation limits in the lower ng/g range. Despite these advances in detector technology, sample preparation is by far the most important error source in modern analytical method development and can be judged as the "Achilles' heel" of any analytical process regarding reliability of the obtained results and time consumption. The aim of the present review is to highlight modern trends for tin and arsenic speciation, as these analytes can be considered as models for challenges in modern method development in this field. First background information, legislative aspects and current needs are elucidated. Then the role of sample treatment within the process of method development in speciation is discussed, followed by a presentation of modern extraction techniques, matching the requirements for arsenic and tin speciation analysis: to provide mild conditions in order to ensure species preservation, to improve species recovery, to enhance sample throughput and to be suitable for hyphenation with chromatographic separation systems. The review includes applications on tin and arsenic speciation, covering the period of 2001-2006.  相似文献   

13.
This article reviews the most recent literature addressing the analytical methods applied for trihalomethanes (THMs) determination in water samples. This analysis is usually performed with gas chromatography (GC) combined with a preconcentration step. The detectors most widely used in this type of analyses are mass spectrometers (MS) and electron capture detectors (ECD). Here, we review the analytical characteristics, the time required for analysis, and the simplicity of the optimised methods. The main difference between these methods lies in the sample pretreatment step; therefore, special emphasis is placed on this aspect. The techniques covered are direct aqueous injection (DAI), liquid-liquid extraction (LLE), headspace (HS), and membrane-based techniques. We also review the main chromatographic columns employed and consider novel aspects of chromatographic analysis, such as the use of fast gas chromatography (FGC). Concerning the detection step, besides the common techniques, the use of uncommon detectors such as fluorescence detector, pulsed discharge photoionization detector (PDPID), dry electrolytic conductivity detector (DELCD), atomic emission detector (AED) and inductively coupled plasma-mass spectrometry (ICP-MS) for this type of analysis is described.  相似文献   

14.
An analytical procedure for selenium speciation of analysis of selenourea (SeU), selenoethionine (SeE), selenomethionine (SeM), Se(VI), Se(IV), dimethylselenide (dMeSe) and dimethyldiselenide (dMedSe) was developed, based on two complementary liquid chromatography (LC) techniques coupled with inductively coupled plasma-mass spectrometry (ICP-MS). Specifically, strong anion exchange (SAX) chromatography coupled with ICP-MS was used for the separation and quantification of all the earlier mentioned Se compounds, except for the two methyl selenides, which could be separated and determined by reversed phase chromatography coupled with ICP-MS. This procedure was applied to a soil sample from the warm springs area of Thermopyles (Greece). For leaching the Se species from the soil sample, four extraction methods, using water at ambient temperature, hot water, methanol and 0.5 M HCl, were tested for their efficiency of extracting the different Se species. The speciation results obtained by the LC-ICP-MS methods were compared with those obtained by voltammetric techniques. The determination of total selenium in the sample was achieved by graphite furnace atomic absorption spectrometry, as well as by ICP-atomic emission spectrometry, after suitable digestion of the sediment sample.  相似文献   

15.
Arsenic speciation analysis   总被引:2,自引:0,他引:2  
Gong Z  Lu X  Ma M  Watt C  Le XC 《Talanta》2002,58(1):77-96
Nearly two dozen arsenic species are present in the environmental and biological systems. Differences in their toxicity, biochemical and environmental behaviors require the determination of these individual arsenic species. Considerable analytical progresses have been made toward arsenic speciation analysis over the last decade. Hyphenated techniques involving a highly efficient separation and a highly sensitive detection have become the techniques of choice. Methods based on high-performance liquid chromatography separation with inductively coupled plasma mass spectrometry, hydride generation atomic spectrometry, and electrospray mass spectrometry detection have been shown most useful for arsenic speciation in environmental and biological matrices. These hyphenated techniques have resulted in the determination of new arsenic species, contributing to a better understanding of arsenic metabolism and biogeochemical cycling. Methods for extracting arsenic species from solid samples and for stabilizing arsenic species in solutions are required for obtaining reliable arsenic speciation information.  相似文献   

16.
The state-of-the-art of multi-element speciation in biological materials by hybrid techniques with inductively coupled plasma-mass spectrometric (ICP-MS) detection is critically reviewed with special attention to multi-metal speciation in metallothioneins (MT) and metallothionein-like proteins (MLP). The most common separation techniques used for the purpose include conventional size-exclusion chromatography (SEC) (with off-line detection) and anion-exchange (AE) or reversed-phase (RP) HPLC coupled on-line to ICP-MS. Advantages and limitations of the different commercial element-selective ICP-MS detectors, including the quadrupole (Q), double focusing (DF), and time-of-flight (TOF) mass analysers, are discussed. Procedures reported for speciation analysis, by use of hybrid techniques, for multi-metal speciation in mussel MLP and rabbit liver MT are illustrated with special emphasis on work performed in the authors' laboratory.  相似文献   

17.
A study has been conducted for the separation and the determination of arsenic species in plants using high-performance liquid chromatography–hydride generation atomic fluorescence spectrometry with emphasis on sample extraction procedures. Various extraction solvents have been applied to extract arsenic species from plants in order to investigate the uptake, transfer and accumulation processes of arsenic. The method was optimized with respect to the selection of extraction solvent, extraction time and the number of extraction steps. The analytical procedure has been validated by analyzing standard reference material GBW 82301 (peach leaves) and successfully used for the arsenic speciation in plants grown on contaminated soil near an arsenic mine. Inorganic arsenic, especially arsenate (As(V)) appears to be the major component in plants and organic arsenic species of monomethylarsenic acid and dimethylarsenic acid were detected at low concentrations.  相似文献   

18.
Speciation studies are much more important than total element determination because toxicity of many elements depends on their chemical forms. Nobody can claim that a foodstuff is very dangerous to eat by determining total arsenic due to the possibility that the arsenic could be present in non-toxic forms. Hence, speciation studies are crucial in any matrix relevant to human beings.Trace-element speciation requires sufficiently sensitive procedures to monitor each species at trace levels. One way to increase the sensitivity for elements forming volatile species is coupling high-performance liquid chromatography (HPLC) with chemical-vapor generation (CVG). This review aims to highlight not only development of HPLC-CVG techniques for ultratrace-elemental speciation in a variety of matrices but also their application. In addition, we discuss the advantages and the disadvantages of these techniques.  相似文献   

19.
The present review describes the speciation techniques of arsenic. The principal advanced techniques discussed are gas chromatography, reversed-phase liquid chromatography, ion chromatography, capillary electrophoresis. Some other techniques are also mentioned. The extraction procedures of arsenic species from unknown samples are also discussed. Arsenic speciation is summarized in tabular form and optimizing parameters are also discussed.  相似文献   

20.
Nowadays much attention is being paid to the determination of trace amounts of noble metals in geological, industrial, biological and environmental samples. The most promising techniques, such as inductively coupled plasma atomic emission spectrometry (ICP-AES), inductively coupled plasma mass spectrometry (ICP-MS) and electrothermal atomic absorption spectrometry (ETAAS) are characterized by high sensitivity. However, the accurate determination of trace noble metals has been limited by numerous interferences generated from the presence of matrix elements. To decrease, or eliminate, these interferences, the sorption preconcentration of noble metals is often used prior to their instrumental detection. A great number of hyphenated methods of noble metal determination using sorption preconcentration have been developed. This review describes the basic types of available sorbents, preconcentration procedures and preparations of the sorbent to the subsequent determination of noble metals. The specific features of instrumental techniques and examples of ETAAS, FAAS, ICP-AES, ICP-MS determinations after the sorption preconcentration of noble metals are considered. The references cited here were selected mostly from the period 1996 - 2006.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏