首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 526 毫秒
1.
Matrix‐assisted laser desorption/ionization mass spectrometry (MALDI‐MS) is a high throughput, easy to use analytical technique. The simple sample preparation of this technique and its tolerance to the presence of contaminants are among its advantages. In contrast, depending on the matrix used, MALDI can ionize and generates ions in the low m /z range that complicate the interpretation of the spectra of low molecular weight compounds. To address this issue, one can envisage the use of tunable ionic matrices that can reduce the low m /z interferents. In this work, the ionic matrices triethylammonium α‐cyano‐4‐hydroxycinnamate and diisopropylammonium α‐cyano‐4‐hydroxycinnamate were used to directly analyze 14 pharmaceutical drugs in different formulations (coated tablets, noncoated tablets, capsules, and solutions). This methodology enabled the detection of their active compounds with minimum sample preparation, thus providing a straightforward approach for the forensic analysis of pharmaceutical drugs in the quest for detecting counterfeits. LDI‐MS experiments were also performed, and the active ingredient in all of the medicines analyzed were detected. However, MALDI‐MS spectra for the medicines analyzed herein showed less or no fragmentation than LDI‐MS, which makes the analysis easier.  相似文献   

2.
The need of cellular and sub‐cellular spatial resolution in laser desorption ionization (LDI)/matrix‐assisted LDI (MALDI) imaging mass spectrometry (IMS) necessitates micron and sub‐micron laser spot sizes at biologically relevant sensitivities, introducing significant challenges for MS technology. To this end, we have developed a transmission geometry vacuum ion source that allows the laser beam to irradiate the back side of the sample. This arrangement obviates the mechanical/ion optic complications in the source by completely separating the optical lens and ion optic structures. We have experimentally demonstrated the viability of transmission geometry MALDI MS for imaging biological tissues and cells with sub‐cellular spatial resolution. Furthermore, we demonstrate that in conjunction with new sample preparation protocols, the sensitivity of this instrument is sufficient to obtain molecular images at sub‐micron spatial resolution. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

3.
In spite of the growing acceptance of matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry for the analysis of a wide variety of compounds, including polymers and proteins, its use in analyzing low‐molecular‐weight molecules (<1000m/z) is still limited. This is mainly due to the interference of matrix molecules in the low‐mass range. Here the derivatized fullerenes covalently bound to silica particles with different pore sizes are applied as thin layer for laser desorption/ionization (LDI) mass spectrometric analysis. Thus, an interference of intrinsic matrix ions can be eliminated or minimized in comparison with the state‐of‐the‐art weak organic acid matrices. The desorption/ionization ability of the developed fullerene–silica materials depends on the applied laser power, sample preparation and pore size of the silica particles. Thus, fullerene–silica serves as an LDI support for mass spectrometric analysis of molecules (<1500 Da). The performance of the fullerene–silica is demonstrated by the mass analysis of variety of small molecules such as carbohydrates, amino acids, peptides, phospholipids and drugs. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

4.
The practice of laser desorption/ionization (LDI) mass spectrometry continues to evolve. In the most commonly adopted manifestation of LDI, matrix assisted LDI, attention continues to be directed towards novel sample application strategies and modifications to the sample plate. Specifically, researchers continue to explore adaptations to the conventional, stainless steel sample plate that is the centerpiece of conventional LDI. Numerous variants of LDI‐MS have been reported based on modifications of the plate surface, but none of these is widely adopted, either by end‐users or by instrument manufacturers. Further, at this time, advances in surface engineering have had only modest impact on day‐to‐day operation. In this article, we review and discuss some of the numerous, but scattered reports on novel LDI strategies with an emphasis on modified sample support substrates and plates. We discuss and highlight innovations that have the potential to markedly enhance the utility of LDI‐MS.  相似文献   

5.
A novel matrix of isoliquiritigenin (ISL), a flavonoid with a chalcone structure (4,2′,4′-trihydroxychalcone), was demonstrated to be advantageous in the analysis of neutral oligosaccharides by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS). With ISL as a matrix, adequate signal for an analyte can be obtained in much lower matrix concentrations and laser intensity compared to commonly used MALDI matrices. Four different sample preparation methods were tested, and the dried droplet method exhibited the best performance on MALDI-TOF-MS analysis of oligosaccharides with ISL as a matrix. For the analysis of carbohydrates, compared with popular matrices such as 2,5-dihydroxybenzoic acid (DHB) and 2,4,6-trihydroxyacetophenone (THAP), ISL exhibited outstanding matrix properties as follows: (1) higher homogeneity of crystallization thus allowing automatic data acquisition, (2) better spectral quality in terms of resolution and signal to noise ratio (S N−1), (3) better salt tolerance, (4) higher sensitivity, and (5) enough fragmentation yield to use LIFT-TOF/TOF MS to get richer structural information. In addition, reliable quantitative analysis of oligosaccharides with a good linearity over two concentration orders (1–100 pmol μL−1) and good reproducibility of the signal intensity (RSD less than 15%) were achieved using this matrix. These results give a new outlook on high-speed analysis of neutral carbohydrates by MALDI-TOF MS.  相似文献   

6.
New data on sample preparation and matrix selection for the fast screening of androgenic anabolic steroids (AAS) by matrix‐assisted laser desorption/ionisation time‐of‐flight mass spectrometry (MALDI‐TOF‐MS) is presented. The rapid screening of 15 steroids included in the World Anti‐Doping Agency (WADA) prohibited list using MALDI was evaluated. Nine organic and two inorganic matrices were assessed in order to determine the best matrix for steroid identification in terms of ionisation yield and interference by characteristic matrix ions. The best results were achieved for the organic matrices 2‐(4‐hydroxyphenylazo)benzoic acid (HABA) and trans‐3‐indoleacrylic acid (IAA). Good signals for all the steroids studied were obtained for concentrations as low as 0.010 and 0.050 µg/mL on the MALDI sample plate for the HABA and IAA matrices, respectively. For these two matrices, the sensitivity achieved by MALDI is comparable with the sensitivity achieved by gas chromatography/mass spectrometry (GC/MS), which is the conventional technique used for AAS detection. Furthermore, the accuracy and precision obtained with MALDI are very good, since an internal mass calibration is performed with the matrix ions. For the inorganic matrices, laser fluences higher than those used with organic matrices are required to obtain good MALDI signals. When inorganic matrices were used in combination with glycerol as a dispersing agent, an important reduction of the background noise was observed. Urine samples spiked with the study compounds were processed by solid‐phase extraction (SPE) and the screening was consistently positive. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

7.
High‐throughput metabolic analysis is of significance in diagnostics, while tedious sample pretreatment has largely hindered its clinic application. Herein, we designed FeOOH@ZIF‐8 composites with enhanced ionization efficiency and size‐exclusion effect for laser desorption/ionization mass spectrometry (LDI‐MS)‐based metabolic diagnosis of gynecological cancers. The FeOOH@ZIF‐8‐assisted LDI‐MS achieved rapid, sensitive, and selective metabolic fingerprints of the native serum without any enrichment or purification. Further analysis of extracted serum metabolic fingerprints successfully discriminated patients with gynecological cancers (GCs) from healthy controls and also differentiated three major subtypes of GCs. Given the low cost, high‐throughput, and easy operation, our approach brings a new dimension to disease analysis and classification.  相似文献   

8.
For matrix‐assisted laser desorption/ionization (MALDI) mass spectra, undesirable ion contamination can occur due to the direct laser excitation of substrate materials (i.e., laser desorption/ionization (LDI)) if the samples do not completely cover the substrate surfaces. In this study, comparison is made of LDI processes on substrates of indium and silver, which easily emit their own ions upon laser irradiation, and conventional materials, stainless steel and gold. A simultaneous decrease of ion intensities with the number of laser pulses is observed as a common feature. By the application of an indium substrate to the MALDI mass spectrometry of alkali salts and alkylammonium salts mixed with matrices, 2,5‐dihydroxybenzoic acid (DHB) or N‐(4‐methoxybenzylidene)‐4‐butylaniline (MBBA), the mixing of LDI processes can be detected by the presence of indium ions in the mass spectra. This method has also been found to be useful for investigating the intrinsic properties of the MALDI matrices: DHB samples show an increase in the abundance of fragment ions of matrix molecules and cesium ions with the number of laser pulses irradiating the same sample spot; MBBA samples reveal a decrease in the level of background noise with an increase in the thickness of the sample layer. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

9.
An analytical method, based on a column coupling capillary ITP and CZE in a hydrodynamically closed separation mode hyphenated with the detection in the modular arrangement, was developed in this work. Analytical possibilities of this approach are demonstrated on the direct and ultrasensitive quantitative determination of quinine (QUI) in diluted real multicomponent ionic matrices (beverages, urine). The detection cell interface, with the rectangular arrangement of the optical channels inside, connected the separation capillary with the LIF detector via optical fibers in the on‐column detection arrangement. ITP enabled the direct large volume (30 μL) injections of the diluted real matrices with an on‐line sample pretreatment (preseparation, preconcentration) so that no external sample preparation (except for the dilution) was necessary for the separation of the analyte in the multicomponent ionic matrices. Due to the ITP sample preconcentration and intrinsic sensitivity of the LIF detection, very low concentration LOD (as low as 77 pg/mL), were reached at the same time. This was ca. two orders lower than the corresponding LOD achieved by the same 2D separation system with UV absorbance detection. Compared to the single column CE‐LIF methods applied for this model analyte and matrix, this method was found to be superior in terms of concentration LOD, with acceptable selectivity and benefits of the on‐line sample preparation. A food control and bioanalytical application clearly illustrates great practical possibilities and routine use of the proposed modular ITP–CZE–LIF technique.  相似文献   

10.
Matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry (MALDI‐TOF MS) is an excellent analytical technique for rapid analysis of a variety of molecules with straightforward sample pretreatment. The performance of MALDI‐TOF MS is largely dependent on matrix type, and the development of novel MALDI matrices has aroused wide interest. Herein, we devoted to seek more robust MALDI matrix for herbal saponins than previous reported, and ginsenoside Rb1, Re, and notoginsenoside R1 were used as model saponins. At the beginning of the present study, 2,5‐dihydroxybenzoic acid (DHB) was found to provide the highest intensity for saponins in four conventional MALDI matrices, yet the heterogeneous cocrystallization of DHB with analytes made signal acquisition somewhat “hit and miss.” Then, graphene oxide (GO) was proposed as an auxiliary matrix to improve the uniformity of DHB crystallization due to its monolayer structure and good dispersion, which could result in much better shot‐to‐shot and spot‐to‐spot reproducibility of saponin analysis. The satisfactory precision further demonstrated that minute quantities of GO (0.1 μg/spot) could greatly reduce the risk of instrument contamination caused by GO detachment from the MALDI target plate under vacuum. More importantly, the sensitivity and linearity of the standard curve for saponins were improved markedly by DHB‐GO composite matrix. Finally, the application of detecting the Rb1 in complex biological sample was exploited in rat plasma and proved it applicable for pharmacokinetic study quickly. This work not only opens a new field for applications of DHB‐GO in herbal saponin analysis but also offers new ideas for the development of composite matrices to improve MALDI MS performance.  相似文献   

11.
The performance of a matrix‐assisted laser desorption/ionization (MALDI) ionic liquid matrix (ILM) consisting of α‐cyano‐4‐hydroxycinnamic acid (CHCA) and aniline (ANI) was evaluated to assess whether it could offer possible advantages over conventional matrices. Ultraviolet (UV), Fourier transform infrared (FTIR), nuclear magnetic resonance (NMR) and laser desorption/ionization mass spectrometry (LDI‐MS) experiments were carried out with the aim of confirming the structure of the ANI‐CHCA ILM. Different model analytes such as amino acids, peptides, proteins, lipids, phospholipids, synthetic polymers, and sugars were tested. Mass spectra with similar or improved signal‐to‐noise (S/N) ratio (compared to CHCA) were invariably obtained demonstrating the potential of this ILM as a general purpose matrix. Furthermore, protein identification by peptide mass fingerprinting (PMF) and database search was facilitated compared to CHCA since higher scores and increased sequence coverage were observed. Finally, a complex lipid mixture (i.e. a raw extract of a milk sample) analysed by MALDI‐MS showed improved S/N ratio, a reduced chemical noise and a limited formation of matrix‐clusters. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

12.
A sample preparation method that is suitable for sensitive detection of underivatized oligosaccharides by matrix‐assisted laser desorption/ionization mass spectrometry (MALDI‐MS) has been investigated. As compared with the conventional dried‐droplet or ethanol (EtOH) recrystallization method, superior mass spectra in terms of ion yield and signal‐to‐noise (s/n) ratio were obtained when methanol (MeOH) was used as a solvent for the mixture of matrix and oligosaccharides. Based on these results, a new sample preparation method, named the ‘reverse thin layer method’, was developed. This method comprises two steps: first, complete drying of the oligosaccharide solution on the MALDI target plate; and second, deposition of the matrix dissolved in a small amount of MeOH. Using this method, a relatively homogeneous matrix crystal was generated and higher yields of both positive and negative ions were obtained from oligosaccharides compared with conventional methods. Notably, the method can be applied to various matrices including both solid and liquid matrices. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

13.
The structural influence of graphene oxide (GO) on laser desorption/ionization mass spectrometry (LDI‐MS) analysis of small molecules was systematically investigated by using size‐fractionated GO. For fractionation of GO, pH‐assisted centrifugation, sequential vacuum filtration, and sonochemical cutting processes were employed and the size‐fractionated GO was thoroughly characterized to understand their size‐dependent optochemical properties. Then, the fractionated GO was applied to the analysis of various small molecules by LDI‐MS to investigate the relationship between their optochemical properties and LDI‐MS performance. We found that large GO sheets (>0.5 μm) were more prone to fragmentation under laser irradiation during LDI‐MS analysis than small GO sheets (<0.5 μm). In this regard, the LDI‐MS analysis efficiency of various small molecules was significantly improved by using nanosized GO (NGO) as a matrix without background interference. In particular, NGO was successfully applied to the sensitive detection of hydrophobic pollutant molecules without requiring any surface‐functionalization, enrichment, and separation process. Therefore, the present study could provide important basic information and be a practical tool for the development of simple and efficient LDI‐MS platforms by using GO derivatives.  相似文献   

14.
We have employed mixtures of two differently sized (average diameters: 3.5 and 14 nm) gold nanoparticles (Au NPs) as selective probes and matrices for the determination of aminothiols using surface‐assisted laser desorption/ionization mass spectrometry (SALDI‐MS). When using 38 and 150 pM solutions of the 3.5‐ and 14‐nm Au NPs, respectively, as the probe and matrix, SALDI‐MS provided limits of detection (signal‐to‐noise ratio = 3) of 2, 20, and 44 nM for 1.0 mL solutions of glutathione (GSH), cysteine (Cys), and homocysteine, respectively. The signal intensities of these analytes varied by less than 20% for SALDI‐MS analyses recorded over 50 sample spots; in contrast, they varied by as much as 60% when using a conventional matrix (2,5‐dihydroxybenzoic acid). We validated the practicality of this approach – with its advantages of sensitivity, reproducibility, rapidity, and simplicity – through the analysis of GSH in MCF‐7 cell lysates and Cys in plasma. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

15.
We describe here an optimization study of the sample preparation conditions for sensitive detection of peptides by matrix‐assisted laser desorption/ionization mass spectrometry (MALDI‐MS). Among many factors in the conditions, we varied the percent acetonitrile in the peptide solution, the percent acetonitrile in the matrix solution and the α‐cyano‐4‐hydroxycinnamic acid (CHCA) concentration in the matrix solution. CHCA was chosen because it is the most frequently used matrix for analyzing peptides. The well‐established dried‐droplet method was employed for sample deposition. The examined range of the concentration of CHCA was from 0.01 to 10 mg/ml, and the MeCN content of the solvent for matrix/analyte was 10% to 50%. The indicator for the detection sensitivity was the S/N ratio of the peaks of peptides used. Highly increased sensitivity (100‐ to 1000‐fold) was observed for the optimal CHCA concentration of 0.1 mg/ml in 20% MeCN/0.1% aq. trifluoroacetic acid (TFA), as compared with the conventional concentration (10 mg/ml) in 50% MeCN/0.1% aq. TFA. For example, the limit of detection of human ACTH 18–39 was 10 amol/well for the optimal condition but 10 fmol/well for the conventional condition. The optimal condition (0.1 mg/ml CHCA in 20% MeCN/0.1% aq. TFA) was verified with five model peptides and provided significant improvement in sensitivity (by two to three orders of magnitude) compared with the conventional conditions. Optimizing the CHCA concentration and solvent composition significantly improved the detection sensitivity in the analysis of peptides by MALDI‐MS. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

16.
High-throughput quantitative bioanalysis by LC/MS/MS   总被引:8,自引:0,他引:8  
This review article discusses the most recent significant advances in the sample preparation and mass spectrometry aspects of high-throughput bioanalysis by LC/MS/MS for the quantitation of drugs, metabolites and endogenous biomolecules in biological matrices. The introduction and implementation of automated 96-well extraction has brought about high-throughput approaches to the biological sample preparation techniques of solid-phase extraction, liquid-liquid extraction and protein precipitation. The fast-flow on-line extraction technique is a different high-throughput approach that has also significantly speeded up analysis by LC/MS/MS. The use of pierceable caps for biological tubes further enhances the analysis speed and improves the safety in handling biological samples. The need for adequate chromatographic separation in order to eliminate interferences due to metabolites and/or matrix effects in LC/MS/MS is discussed. To highlight our limited understanding of atmospheric pressure ionization mass spectrometry, results from recent investigations that appear to be counter-intuitive are presented. Looking ahead to the future, multiplexed LC/MS/MS systems and capillary LC are presented as areas that can bring about further improvements in analysis speed and sensitivity to quantitative bioanalysis by LC/MS/MS.  相似文献   

17.
A comparison of ionization efficiency for gold and silver nanoparticles used as an active media of matrix‐less laser desorption/ionization (LDI) mass spectrometry (MS) methods was made for carboxylic acids including fatty acids. The matrix‐assisted laser desorption/ionization (MALDI)‐type targets containing monoisotopic cationic 109Ag nanoparticles (109AgNPs) and Au nanoparticles (AuNPs) were used for rapid MS measurements of 10 carboxylic acids of different chemical properties. Carboxylic acids were directly quantified in experiments with 10 000‐fold concentration change conditions ranging from 1 mg/ml to 100 ng/ml which equates to 1 μg to 100 pg of carboxylic acids per measurement spot.  相似文献   

18.
Fluorescent semiconductor quantum dots (QDs) exhibit great potential and capability for many biological and biochemical applications. We report a simple strategy for the synthesis of aqueous stable ZnSe QDs by using cysteine as the capping agent (ZnSe‐Cys QDs). The ZnSe QDs can act as affinity probes to enrich peptides and proteins via direct matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry (MALDI‐TOFMS) analysis. This nanoprobe could significantly enhance protein signals (insulin, ubiquitin, cytochrome c, myoglobin and lysozyme) in MALDI‐TOFMS by 2.5–12 times compared with the traditional method. Additionally, the ZnSe‐Cys QDs can be applied as heat absorbers (as accelerating probes) to speed up microwave‐assisted enzymatic digestion reactions and also as affinity probes to enrich lysozyme‐digested products in MALDI‐TOFMS. Furthermore, after the enrichment experiments, the solutions of ZnSe‐Cys QDs mixed with proteins can be directly deposited onto the MALDI plates for rapid analysis. This approach shows a simple, rapid, efficient and straightforward method for direct analysis of proteins or peptides by MALDI‐TOFMS without the requirement for further time‐consuming separation processes, tedious washing steps or laborious purification procedures. The present study has demonstrated that ZnSe‐Cys QDs are reliable and potential materials for rapid, selective separation and enrichment of proteins as well as accelerating probes for microwave‐digested reactions for proteins than the regular MALDI‐MS tools. Additionally, we also believe that this work may also inspire investigations for applications of QDs in the field of MALDI‐MS for proteomics. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

19.
Ke Y  Kailasa SK  Wu HF  Chen ZY 《Talanta》2010,83(1):178-184
CdS quantum dots (∼5 nm) are used as multifunctional nanoprobes as an effective matrix for large proteins, peptides and as affinity probes for the enrichment of tryptic digest proteins (lysozyme, myoglobin and cytochrome c) in laser desorption/ionization time-of-flight mass spectrometry (LDI-TOF MS). The use of CdS quantum dots (CdS QDs) as the matrix allows acquisition of high resolution LDI mass spectra for large proteins (5000-80,000 Da). The enhancement of mass resolution is especially notable for large proteins such as BSA, HSA and transferrin (34-49 times) when compared with those obtained by using SA as the matrix. This technique demonstrates the potentiality of LDI-TOF-MS as an appropriate analytical tool for the analysis of high-molecular-weight biomolecules with high mass resolution. In addition, CdS QDs are also used as matrices for background-free detection of small biomolecules (peptides) and as affinity probes for the enrichment of tryptic digest proteins in LDI-TOF-MS.  相似文献   

20.
Quaternary protoberberine alkaloids belong to a pharmaceutically important class of isoquinoline alkaloids associated with bactericidal, fungicidal, insecticidal and antiviral activities. As traditional medicine gains wider acceptance, quick and robust analytical methods for the screening and analysis of plants containing these compounds attract considerable interest. Thin‐layer chromatography (TLC) combined with matrix‐assisted laser desorption/ionization mass spectrometry (MALDI‐MS) is a powerful technique but suffers from dilution of the TLC bands resulting in decreased sensitivity and masking of signals in the low‐mass region both due to addition of matrix. This study integrates for the first time conventional silica gel TLC and laser desorption ionization mass spectrometry (LDI‐MS) thus eliminating the need for any external matrix. Successful separation of berberine (Rf = 0.56) and palmatine (Rf = 0.46) from Berberis barandana including their identification by MS are demonstrated. Furthermore, a robust electrospray ionization (ESI)‐MS method utilizing residual sample from TLC for quantification of berberine applying selected reaction monitoring and standard addition method is presented. The amount of berberine in the plant root prepared for the study was determined to be 0.70% (w/w). Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号