首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 32 毫秒
1.
A rapid and stereospecific HPLC micromethod to quantify flurbiprofen enantiomers was developed. Both flurbiprofen enantiomers and indomethacin, used as internal standard, were extracted with methylene chloride from 100 microL of acidified plasma. The resolution of the R- and S-forms was performed on a bonded vancomycin chiral stationary phase (Chirobiotic V) with 20% of tetrahydrofuran in ammonium nitrate (100 mM, pH 5) as mobile phase. Calibration curves were linear in the range 0.5-10 microg/mL for both enantiomers. A good accuracy (< or = 5%) was obtained for all quality controls, with intra-day and inter-day variation coefficients equal or less than 7.7%. Recovery of both enantiomers was found in the range 77.4-86.3%. The lower limit of quantitation was 0.25 microg/mL for both enantiomers, without interference of endogenous components. This validated micromethod has been successfully applied for quantifying R- flurbiprofen and S- flurbiprofen in rat plasma.  相似文献   

2.
Direct reversed-phase high-performance liquid chromatographic methods were developed for the separation of enantiomers of eighteen unnatural β-amino acids, including several β-3-homo-amino acids. The direct separations of the underivatized analytes were performed on chiral stationary phases containing macrocyclic glycopeptide antibiotics such as teicoplanin (Chirobiotic T and T2), teicoplanin aglycone (Chirobiotic TAG), vancomycin (Chirobiotic V and V2), and ristocetin A (Chirobiotic R) as chiral selectors. The effects of the organic modifier, mobile phase composition and pH on the separations were investigated. A comparison of the separation performances of the macrocyclic glycopeptide stationary phases revealed that the Chirobiotic T2 column exhibited better selectivity than the Chirobiotic T column for the separation of β-3-homo-amino acid enantiomers; vancomycin or ristocetin A exhibited lower selectivity. The elution sequence was determined in some cases: the S enantiomers eluted before the R enantiomers, with the exception of the Chirobiotic R column, where the elution sequence R < S was observed.  相似文献   

3.
A high-performance liquid chromatographic method for chiral separation of ketoprofen racemate was developed. (R)- and (S)-ketoprofen enantiomers were separated on a LiChrosorb NH2 column (250 mm × 4.6 mm, i.d 5 µm) at 20 °C, using 2-propanol/potassium dihydrogen phosphate buffer (pH 6.0, 0.05 M) (50:50 v/v). Containing vancomycin as the mobile phase, at a flow rate of 0.8 ml min?1 and detection wavelength of UV, the detector was set at 310 nm. Under these conditions, ketoprofen enantiomers could be separated with a selectivity factor (α) of 2.172 and a resolution (Rs) of 4.78 using extremely low concentrations of the vancomycin chiral additive.  相似文献   

4.
Berkecz  R.  Ilisz  I.  Forr&#;  E.  F&#;l&#;p  F.  Armstrong  D. W.  P&#;ter  A. 《Chromatographia》2006,63(13):S29-S35
Direct reversed-phase high-performance liquid chromatographic methods were developed for the separation of enantiomers of β-lactams. The enantiomers of 7 aryl-substituted β-lactams were separated on chiral stationary phases containing the macrocyclic glycopeptide antibiotic teicoplanin (Chirobiotic T) and teicoplanin aglycone (Chirobiotic TAG) at 10-°C increments in the range 5–45 °C, using different compositions of 0.1% aqueous triethylammonium acetate (pH 4.1)/methanol (v/v) as mobile phase. The mobile phase composition and temperature were varied to achieve baseline resolutions in a single chromatographic run. The dependence of the natural logarithms of the selectivity factors ln α on the inverse of temperature, 1/T, was used to determine the thermodynamic data on the enantiomers. The thermodynamic data revealed that all the compounds in this study undergo separation via the same enthalpy-driven chiral recognition mechanism. The different methods were compared in systematic chromatographic examinations. The effects of the organic modifier, the mobile phase composition and the temperature on the separation were investigated.  相似文献   

5.
Direct and indirect reversed-phase (RP) high-performance liquid chromatographic methods were developed for the separation of enantiomers of 18 unnatural beta-amino acids, including several beta-3-homo amino acids. The direct separations of the underivatized analytes were performed on chiral stationary phases (CSPs) containing macrocyclic glycopeptide antibiotic teicoplanin (Chirobiotic T column) and teicoplanin aglycone (Chirobiotic TAG column). The indirect method involved pre-column derivatization with a new chiral derivatizing agent (CDA), (S)-N-(4-nitrophenoxycarbonyl)phenylalanine methoxyethyl ester ((S)-NIFE), and subsequent separation of diastereomers on Discovery C18 and Hyperpep 300 C18 columns. The different methods were compared in systematic chromatographic examinations. The effects of organic modifier, mobile phase composition, pH and flow rate on the separation were investigated.  相似文献   

6.
Summary An easy and rapid enantioselective separation for assay of racemic thalidomide on an immobilized α1-acid glycoprotein chiral stationary phase (GPA CSP) is described. The effects of tetrahydrofuran (THF) as organic modifier, buffer concentration to control the ionic strenth, and mobile phase pH were studied. These variations have consequences in terms of chromatographic retention (k), resolution (R s), selectivity (α), and peak asymmetry (USP tailing factor). The main condition affecting chromatographic retention was mobile phase pH. At pH 4.5, no separation of thalidomide enantiomers was achieved whereas at pH 7.9 chiral separation was optimum. Peak tailing was directly related to changes in pH and to addition of THF as mobile phase modifier. Results also indicated that the resolution factor is THF concentration-dependent, and that the separation factor (α) is the best parameter for evaluating enantioselectivity. The best mobile phase was pH 7.0, 30 mM ammonium acetate containing 0.3% THF. Under these conditions validation including linearity, recovery, and precision was performed. The suitability of this method has been successfully proved in a limited in-vivo study after intravenous administration of thalidomide to a New Zealand male rabbit.  相似文献   

7.
Summary Reversed-phase high-performance liquid chromatographic methods were developed for the separation of the enantiomers of five glycine and twelve alanine analogues. The enantioselective separation involved two methods. The direct separations were performed on chiral stationary phases containing a macrocyclic glycopeptide antibiotic: teicoplanin (Chirobiotic T column), ristocetin A (Chirobiotic R column) or chiral crown ether (Crownpak CR(+) column). The indirect methods involved pre-column derivatization with the chiral derivatizing agents 2,3,4,6-tetra-O-acetyl-β-D-glucopyranosyl isothiocyanate andN-α-(2,4-dinitro-5-fluorophenyl)-L-alaninamide (Marfey's reagent). The different methods were compared in systematic chromatographic examinations. The effects of organic modifier content, mobile phase composition, pH and flow rate on the separation were investigated. Presented at Balaton Symposium '01 on High-Performance Separation Methods, Siófok, Hungary, September 2–4, 2001  相似文献   

8.
The peak compression effect has been applied to improve quantification limits in chiral capillary electrochromatography (CEC). A stationary phase based on the chiral selector vancomycin (Chirobiotic V) was used for separations of the enantiomers of mianserin. By adding solvents with a low dielectric constant, e.g. 2-propanol or tetrahydrofuran, to the sample solution, peak compression could be induced. The plate numbers for the minor enantiomer increased from approximately 100,000 to 1.4-1.6 million plates/m, when the composition of the mobile phase was adjusted so that the analyte eluted within either one of two system zones originating from the sample solution. A 10-fold improvement in the quantification limit for the minor enantiomer was obtained compared to elution under non-focused conditions.  相似文献   

9.
Berkecz  R.  T&#;r&#;k  R.  Ilisz  I.  Forr&#;  E.  F&#;l&#;p  F.  Armstrong  D. W.  P&#;ter  A. 《Chromatographia》2006,63(13):S37-S43

Direct reversed-phase high-performance liquid chromatographic methods were developed for the separation of the enantiomers of tricyclic β-lactams, cis-3,4-benzo-6-azabicyclo[3.2.0]heptan-7-one, cis-4,5-benzo-7-azabicyclo[4.2.0]-octan-8-one, cis-5,6-benzo-8-azabicyclo[5.2.0]nonan-9-one and new bicyclic β-amino acids, the six- and seven-membered homologues of cis-1-amino-4,5-benzocyclopentane-2-carboxylic acid (benzocispentacin), cis-1-amino-5,6-benzocyclohexane-2-carboxylic acid and cis-1-amino-6,7-benzocycloheptane-2-carboxylic acid. The direct separations of the analytes were performed on chiral stationary phase (CSP) columns containing the macrocyclic glycopeptide antibiotic teicoplanin (Chirobiotic T), teicoplanin aglycone (Chirobiotic TAG), vancomycin (Chirobiotic V), vancomycin aglycone (Chirobiotic VAG), ristocetin A (Chirobiotic R) or a new dimethylphenyl carbamate-derivatized β-cyclodextrin-based Cyclobond DMP. The results achieved with the different methods were compared in systematic chromatographic examinations. The effects of an organic modifier and of the mobile phase composition on the separation and the separation efficiency of different columns were investigated. The difference in enantioselective free energy between the aglycone CSP and the teicoplanin CSP for these β-lactams and β-amino acids ranged between 0.3 and −1.1 kJmol−1. Better enantioseparations were attained in most cases on the aglycone CSP.

  相似文献   

10.
The direct separation of the enantiomers of four 2-aminomono- or dihydroxycyclopentanecarboxylic acids and four 2-aminodihydroxycyclohexanecarboxylic acids was performed on chiral stationary phases containing macrocyclic glycopeptide antibiotics such as teicoplanin (Astec Chirobiotic T and T2), teicoplanin aglycone (Chirobiotic TAG) or ristocetin A (Chirobiotic R) as chiral selectors. The effects of the nature of organic modifiers, the pH, the mobile phase composition and the structures of the analytes on the separation were investigated. Chirobiotic TAG, and in some cases Chirobiotic T, proved to be the most useful of these columns. The elution sequence was determined in most cases.  相似文献   

11.
叶晓霞  俞雄 《分析化学》2003,31(5):522-526
以丹酰化苯甘氨酸、丹酰化苯丙氨酸、丹酰化丝氨酸、丹酯化丙氨酸为模型化合物,通过对色谱柱类型、缓冲液类型、pH和盐浓度、万古霉素用量、甲醇用量、柱温等色谱参数进行考察,建立了以万古霉素为手性流动相添加剂在普通色谱柱上进行手性分析的色谱系统,并在该系统中成功地拆分了酮洛芬对映体。  相似文献   

12.
张丹丹  王欣欣 《化学研究》2014,25(6):604-608
基于三种大环抗生素类手性固定相Chirobiotic V,T和R,利用高效液相色谱法对盐酸马布特罗对映体进行了拆分;考察了洗脱模式、流动相组成、柱温等因素对分离的影响,对分离结果进行了比较,对分离机制进行了探讨.结果表明,盐酸马布特罗对映体在Chirobiotic R手性固定相上不能实现分离,在Chirobiotic V和T手性固定相上均可实现较好的基线分离.最佳色谱条件为:新极性有机相模式,流动相甲醇-冰醋酸-三乙胺(100∶0.01∶0.01,V/V/V),流速1.0mL/min,柱温20℃;相应的分离度分别可达3.08和3.73.与此同时,盐酸马布特罗对映体与大环抗生素类固定相之间的离子相互作用是实现对映体分离的最主要分离机制.  相似文献   

13.
A fast, selective and reproducible solid‐phase membrane microtip extraction (SPMMTE) HPLC method has been developed and validated for the analyses of ibuprofen, ketoprofen, and flurbiprofen from human plasma. The analysis was carried out on a C18 (150 × 4.6 mm; 5 μm) column. The mobile phase used was water–acetonitrile (55:45, v/v) adjusted to pH 3.0 using trifluoroacetic acid, at a flow rate 0.5 mL/min with a detection wavelength of 225 nm. The values for the capacity factors for the profen samples ranged from 0.47 to 1.50. The values for the selectivity factor (α) for ketoprofen–flurbiprofen, flurbiprofen–ibuprofen and ibuprofen–ketoprofen combinations from human plasma samples were 1.99, 1.00 and 2.10, respectively. The resolution factors (Rs) for ketoprofen–flurbiprofen, flurbiprofen–ibuprofen and ibuprofen–ketoprofen from plasma samples were 3.00, 1.50 and 4.10, respectively. The percentage recoveries of ibuprofen, ketoprofen, and flurbiprofen from human plasma were 75–85%. All of the profens were separated within 7.0 min, indicating a relatively fast method. During the development of the SPMMTE procedure the parameters of pH, contact time, desorption and types of solvents were optimized. The final method was also found to be efficient, effective and inexpensive. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

14.
LC-electrospray ionization (ESI) MS conditions were optimized for the individual chiral separation of 19 compounds of pharmaceutical interest using the macrocyclic glycopeptide-based chiral stationary phases in both polar organic and reversed-phase modes (RPM). The influence of mobile phase composition and MS additive type on sensitivity was investigated for all classes of compounds tested. Compounds with amine or amide groups were efficiently separated, ionized, and detected with the addition of 0.1% (w/w) ammonium trifluoroacetate to the solvent system in either the reversed-phase or polar organic mode (POM). Macrocyclic glycopeptide coupled column technology was initially used to screen all chiral compounds analyzed. Baseline resolution of enantiomers was then achieved with relatively short retention times and high efficiencies on Chirobiotic T, Chirobiotic V or Chirobiotic R narrow bore chiral stationary phases. The polar organic mode offered better limits of detection (as low as 100 pg/ml) and sensitivity over reversed-phase methods. An optimum flow-rate range of 200-400 microl/min was necessary for sensitive chiral LC-ESI-MS analysis.  相似文献   

15.
In this paper we studied the potentiality of nano-liquid chromatography (nano-LC) for the enantiomeric resolution of both basic and acidic compounds of pharmaceutical interest using a vancomycin modified silica stationary phase. Experiments were carried out in a fused silica capillary of 75 microm I.D. packed with chiral modified silica particles of 5 microm diameter, the detection, was done on-line at 195 nm. Enantiomeric resolution of alprenolol, atenolol, metoprolol, oxprenolol, pindolol, propranolol (basic compounds) and some acidic analytes, namely 2-[(5'-benzoyl-2'-hydroxy)phenyl]propionic acid (DF1738Y), 2-[(4'-benzoyloxy-2'-hydroxy)phenyl]propionic acid (DF1770Y), ketoprofen, indoprofen and suprofen was studied by nano-LC utilizing mobile phases containing methanol-acetonitrile-ammonium formate or acetate. The effect of mobile phase composition (buffer type and concentration, organic modifier type and concentration) on chiral resolution (Rs), retention factor (k) and retention time (tR) was also investigated. Good enantiomeric resolution was achieved for basic compounds utilizing the mobile phase containing 90% (MeCN-MeOH)/5% water/5% of 100 mM ammonium acetate pH 4.5. Acidic compounds such as DF1738Y and DF1770Y were better resolved at lower pH 3.5 while ketoprofen, indoprofen and suprofen exhibited the highest resolution at pH 4.5; in this case the mobile phase contained MeOH or MeCN (90%), 5% buffer and 5% of water. The nano-LC method was validated using R-(+)-propranolol as an internal standard finding good repeatability, detection limit, correlation coefficient and recovery and applied to the assay of a pharmaceutical formulation containing a racemic mixture of metoprolol.  相似文献   

16.
The direct enantioseparation of duloxetine and its R-enantiomer was achieved by HPLC using hydroxypropyl-β-cyclodextrin (HP-β-CD) as a chiral selector and a vancomycin chiral stationary phase (Chirobiotic V). Operational parameters, such as the concentration of HP-β-CD, buffer pH, organic modifiers, temperature and flow rate, were varied in order to achieve the desired retention time and resolution. These two enantioseparation methods developed gave a baseline resolution of the enantiomers. Finally, the HPLC-CSP method was selected to determine the enantiomeric purity of duloxetine drug substance due to its much shorter analysis time and better resolution. The limit of detection of this method was 0.06 μg mL−1.  相似文献   

17.
卵类粘蛋白柱手性拆分酮基布洛芬   总被引:2,自引:0,他引:2  
王解静  曹桂芳  徐诗伟 《色谱》2000,18(6):536-538
 在卵类粘蛋白柱上 ,考察了酮洛芬对映体在 3种流动相体系下的保留行为 ,建立了同时分离酮洛芬及其甲酯两对对映体的较佳色谱条件。方法可用于酶法立体选择性水解或酯化过程中生成的 4种化合物的同时测定  相似文献   

18.
关瑾  杨晶  毕玉金  石爽  李发美 《色谱》2007,25(5):732-734
利用反相高效液相色谱法在大环抗生素类手性固定相万古霉素键合手性固定相(Chirobiotic V)上直接分离了泰妥拉唑对映体。考察了缓冲溶液的种类、浓度和pH值,有机改性剂的种类和浓度,柱长和柱温等对手性分离的影响。优化后的色谱条件为:Chirobiotic V色谱柱(150 mm×4.6 mm,5 μm),流动相为0.02 mol/L 醋酸铵缓冲液(pH 6.0)-四氢呋喃(体积比为93∶7),流速为0.5 mL/min,柱温为20 ℃,检测波长为306 nm。在此条件下泰妥拉唑对映体达到了基线分离,分离度达1.68;对映体保留时间的相对标准偏差分别为0.48%和0.49%(n=6),峰面积的相对标准偏差分别为0.45%和0.55%(n=6)。所建立的手性分离方法具有简便快速及重复性好等优点。  相似文献   

19.
The enantiomers of eight unusual beta(2)- and beta(3)-homoamino acids were separated on chiral stationary phases containing the macrocyclic glycopeptide antibiotic teicoplanin (Chirobiotic T or T2) or teicoplanin aglycone (Chirobiotic TAG) as chiral selectors. The effects of the organic modifier, the mobile phase composition, and temperature on the separations were investigated. Linear van't Hoff plots were observed in the studied temperature range, 280-318 K, and the changes in enthalpy, Delta(DeltaH(o)), entropy, Delta(DeltaS(o)), and free energy, Delta(DeltaG(o)) were calculated. The values of the thermodynamic parameters depended on the nature of the selectors, the structures of the analytes, and especially the positions of the substituents on the analytes. A comparison of the separation performances of the macrocyclic glycopeptide stationary phases revealed that the Chirobiotic TAG column exhibited much better selectivity for beta(2)-homoamino acids, while the separation of beta(3)-homoamino acid enantiomers was better on Chirobiotic T or T2. The elution sequence was determined in some cases and was observed to be R < S.  相似文献   

20.
A direct chiral LC‐UV method was optimized for the determination of salbutamol (SAL) β2‐agonist in environmental water. Two commercially available columns were evaluated: teicoplanin Chirobiotic‐T? (150 × 2.1 mm i.d., 5 µm) and vancomycin Chirobiotic‐V? (150 × 2.1 mm i.d., 5 µm). Finally, teicoplanin chiral stationary phase was selected for SAL enantiomer resolution. In order to preserve its integrity and maintain the column performance for longer time, the use of additives such as triethylamine (TEA) in the mobile phase was avoided. Experimental design was applied to simultaneously evaluate the influence of several parameters involved in enantiomer separation and to establish the conditions for acceptable resolution and performance in short analysis time. Optimum mobile phase was methanol–20 mM ammonium acetate buffer at pH 4.5 (98:2, v/v). A solid‐phase extraction procedure for sample pre‐concentration and clean‐up allowed the determination of chiral SAL residues in natural water samples spiked at low concentrations in the range 1.0–20 ng mL?1. Reproducible recoveries, between 77 and 98%, were obtained and matrix effect was negligible. Injection of sample solutions at low elution strength permitted the SAL enantioresolution in the natural water complex matrix with satisfactory sensitivity and precision. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号