首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到10条相似文献,搜索用时 156 毫秒
1.
Lead isotope ratios, viz. 207Pb/206Pb and 208Pb/206Pb, of the commercially available certified reference materials (CRMs) issued in Japan are presented with an objective to provide a data set, which will be useful for the quality assurance of analytical procedures, instrumental performance and method validation of the laboratories involved in environmental lead isotope ratio analysis. The analytical method used in the present study was inductively coupled plasma quadrupole mass spectrometry (ICPQMS) preceded by acid digestion and with/without chemical separation of lead from the matrix. The precision of the measurements in terms of the relative standard deviation (RSD) of triplicated analyses was 0.19% and 0.14%, for 207Pb/20Pb and 208Pb/206Pb, respectively. The trueness of lead isotope ratio measurements of the present study was tested with a few CRMs, which have been analyzed by other analytical methods and reported in various literature. The lead isotopic ratios of 18 environmental matrix CRMs (including 6 CRMs analyzed for our method validation) are presented and the distribution of their ratios is briefly discussed.  相似文献   

2.
Certified reference materials (CRMs) play a critical role in validating the accuracy of nutrient data for food samples. A number of available food CRMs of differing matrix composition have assigned concentrations for various nutrients, along with associated uncertainty intervals (UIs) for those values. These CRMs have been used extensively in the United States Department of Agriculture’s (USDA) ongoing National Food and Nutrient Analysis Program (NFNAP) to monitor the accuracy of assays of key foods and nutrients consumed in the United States. A total of 690 assigned values for individual nutrients, including proximates, vitamins, macroelements, microelements, fatty acids, amino acids, and selected phytochemicals (e.g., carotenoids), were compiled from the certificates of analysis for 63 CRMs, and the specified UI in each case was expressed as a percentage of the assigned certified or reference concentration. Across all nutrients, 63.5% of the UIs were less than 10% of the assigned value, 25.5% were 10–20%, and 11% were greater than 20% of the assigned value. The UIs for proximates, minerals, and trace elements were most consistently less than 10% of the assigned value. The relative uncertainties were significantly higher for vitamins, suggesting greater challenges in measuring and certifying these components. These high UIs (greater than 10% assigned value) in the best available reference materials are likely to be indicative of the precision and accuracy that can be obtained by current measurement systems for these components. These data suggest that care must be taken in choosing CRMs to monitor food composition analysis, including evaluating what levels of uncertainty are required in assigned values and which analytical measurement systems for food components need closer examination and improvement. Electronic supplementary material The online version of this article (doi:) contains supplementary material, which is available to authorized users. Presented at ‘BERM-10’, April 2006, Charleston, SC, USA.  相似文献   

3.
Increasing numbers of clinical laboratories are transitioning away from flame and electrothermal AAS methods to those based on ICP-MS. Still, for many laboratories, the choice of instrumentation is based upon (a) the element(s) to be determined, (b) the matrix/matrices to be analyzed, and (c) the expected concentration(s) of the analytes in the matrix. Most clinical laboratories specialize in measuring Se, Zn, Cu, and Al in serum, and/or Pb, Cd, Hg, As, and Cr in blood and/or urine, while other trace elements (e.g., Pt, Au etc.) are measured for therapeutic purposes. Quantitative measurement of elemental species is becoming more widely accepted for nutritional and/or toxicological screening purposes, and ICP-MS interfaced with separation techniques, such as liquid chromatography or capillary electrophoresis, offers the advantage of on-line species determination coupled with very low detection limits. Polyatomic interferences for some key elements such as Se, As, and Cr require instrumentation equipped with dynamic reaction cell or collision cell technologies, or might even necessitate the use of sector field ICP-MS, to assure accurate results. Nonetheless, whatever analytical method is selected for the task, careful consideration must be given both to specimen collection procedures and to the control of pre-analytical variables. Finally, all methods benefit from access to reliable certified reference materials (CRMs). While a variety of reference materials (RMs) are available for trace element measurements in clinical matrices, not all can be classified as CRMs. The major metrological organizations (e.g., NIST, IRMM, NIES) provide a limited number of clinical CRMs, however, secondary reference materials are readily available from commercial organizations and organizers of external quality assessment schemes.  相似文献   

4.
Matrix certified reference materials (CRMs) are playing an increasingly important role in environmental monitoring in Japan. The National Metrology Institute of Japan (NMIJ)/National Institute of Advanced Industrial Science and Technology (AIST) has been developing matrix CRMs for environmental monitoring since 2001, and has issued nine kinds of CRMs as NMIJ CRMs. The development of the CRMs was conducted in NMIJ in cooperation with candidate material producers. The isotope dilution mass spectrometry (IDMS) was principally adopted to give reliable certified values. Meanwhile, two or more analytical methods, whose levels of accuracy were well evaluated, were applied to avoid any possible analytical bias. Two typical certification processes, the certification of river water CRMs for trace element analysis and that of marine sediment CRMs for PCB and organochlorine pesticide analysis, are outlined as examples. Presented at -- “BERM-10” -- April 2006, Charleston, SC, USA.  相似文献   

5.
Certified reference materials (CRMs) are important quality assurance tools in the laboratory. It is, however, not certain they are always used properly. Several guidelines are available on the use of CRMs, but appear to be mostly unknown. The users thus get very little help on the way to proper use. Many of the problems with CRMs are well known, but that does not mean they have disappeared. Better use of CRMs will require the involvement of producers and analytical societies, e.g. the AOAC. Editors of international analytical journals could have a great influence on how CRM results and other QA data are treated in publications.  相似文献   

6.
Two freshwater sediments certified reference materials (CRMs) for 16 polycyclic aromatic hydrocarbons (PAHs) have been developed by the Institute for Environmental Reference Materials (IERM) of Ministry of Environmental Protection (MEP) in China. The methodology for preparing the CRMs of PAHs in sediments is described in this paper. The collected natural sediment samples were air-dried, ground, homogenised, packed, sterilised and tested on stability and homogeneity. Homogeneity results showed that the between-unit variation was confirmed to be below 4.5% for each compound. Stability was assessed after storage of samples for 16 months at temperature less than 30°C and in shade. The certification of the natural sediment matrix CRMs for PAHs was based on the agreement of results using different analytical techniques including gas chromatography/mass spectrometry (GC/MS) and reversed-phase liquid chromatography (LC) by no less than eight collaborating laboratories including IERM. Results of the homogeneity showed that the calculated ubb′ was 0.9–2.5% for environmental river standard-4 (ERS-4) and 9–2.3% for environmental lake standard-1 (ELS-1), whereas stability results of total 16 PAHs indicated that the calculated urel,lts was 4.2% for ERS-4 and 2.2% for ELS-1. Certified values of 16 PAHs in ERS-4 varied from 8.5 to 167 μg/kg and ranged from 0.036 to 2.8 mg/kg in ELS-1.The good comparability, together with the independent confirmation of the assigned mass fraction by using different methods, confirmed that the CRMs are suitable for the method validation and quality control in soil or sediments analysis.  相似文献   

7.
Two marine sediment certified reference materials, NMIJ CRM 7304-a and 7305-a, have been issued by the National Metrology Institute of Japan in the National Institute of Advanced Industrial Science and Technology (NMIJ/AIST) for the determination of polychlorinated biphenyls (PCBs) and organochlorine pesticides (OCPs). The raw materials of the CRMs were collected from a bay near industrial activity in Japan. Characterization of these CRMs was conducted by NMIJ, where the sediments were analyzed using multiple analytical methods such as pressurized liquid extraction (PLE), microwave-assisted extraction (MAE), saponification, Soxhlet extraction, supercritical fluid extraction (SFE), and ultrasonic extraction; the target compounds were determined by one of the primary methods of measurements, isotope dilution–mass spectrometry (ID-MS). Certified values have been provided for 14 PCB congeners (PCB numbers 3, 15, 28, 31, 70, 101, 105, 138, 153, 170, 180, 194, 206, 209) and 4 OCPs (γ-HCH, 4,4′-DDT, 4,4′-DDE, 4,4′-DDD) in both CRMs. NMIJ CRM 7304-a has concentrations of the contaminants that are a factor of 2–15 greater than in CRM 7305-a. Both CRMs have information values for PCB homolog concentrations determined by collaborative analysis using a Japanese official method for determination of PCBs. The total PCB concentrations in the CRMs are approximately 920 and 86 μg kg−1 dry mass respectively. Electronic supplementary material Supplementary material is available in the online version of this article at and is accessible for authorized users.  相似文献   

8.
An analytical protocol for the determination of the extractable phosphorus contents in freshwater sediments has been harmonized through interlaboratory studies in the frame of the Standards Measurements and Testing Program of the European Commission. A homogeneous and stable sediment reference material has been prepared and certified on the basis of this protocol named SMT protocol, and will be available in spring of 2001. The SMT protocol, together with the reference material, are useful tools in the field of water management, especially at a time when quality assurance and data comparability are of paramount importance in laboratory analysis. The knowledge of the bioavailable forms of phosphorus is important not only for sediments but also for sludge and soils. Therefore, the SMT protocol could be extended to these materials and new CRMs could be prepared. The SMT protocol was used in a study of a reservoir, which allowed to calculate the P stock, therefore helping to predict the restoration delay of the lake. The paper describes the protocol and the CRM, and gives a brief outline of the case study. Received: 14 November 2000 / Revised: 25 January 2001 / Accepted: 31 January 2001  相似文献   

9.
A certified matrix reference material (CRM) for the measurement of benzene in ambient air has been developed at Laboratoire National de Métrologie et d’Essais. The production of these CRMs was conducted using a gravimetric method fully traceable to the International System of Units. The CRMs were prepared by sampling an accurate mass of a gaseous primary reference material of benzene, using a high-precision laminar flowmeter and a mass flow controller, with a PerkinElmer sampler filled with Carbopack™ X sorbent. The relative standard deviations obtained for the preparation of a batch of 20 tubes loaded with 500 ng of benzene were below 0.2%. Each CRM is considered independent from the others and with its own certified value and an expanded uncertainty estimated to be within 0.5%, lower than the uncertainties of benzene CRMs already available worldwide. The stability of these materials was also established up to 12 months. These CRMs were implemented during proficiency testing, to evaluate the analytical performances of seven French laboratories involved in benzene air monitoring.  相似文献   

10.
An analytical protocol for the determination of the extractable phosphorus contents in freshwater sediments has been harmonized through interlaboratory studies in the frame of the Standards Measurements and Testing Program of the European Commission. A homogeneous and stable sediment reference material has been prepared and certified on the basis of this protocol named SMT protocol, and will be available in spring of 2001. The SMT protocol, together with the reference material, are useful tools in the field of water management, especially at a time when quality assurance and data comparability are of paramount importance in laboratory analysis. The knowledge of the bioavailable forms of phosphorus is important not only for sediments but also for sludge and soils. Therefore, the SMT protocol could be extended to these materials and new CRMs could be prepared. The SMT protocol was used in a study of a reservoir, which allowed to calculate the P stock, therefore helping to predict the restoration delay of the lake. The paper describes the protocol and the CRM, and gives a brief outline of the case study.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号