首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
A sensitive and selective routine method for the simultaneous determination of prostaglandin E1 (PGE1), prostaglandin E0 (PGE0) and 15-keto-prostaglandin E0 (15-keto-PGE0) in human plasma is described using deuterated internal standards. The analytes were isolated from acidified human plasma by solid-phase extraction by means of Bond Elut C18 cartridges and derivatized to the pentafluorobenzyl (PFB) ester methoxime. The analytes were purified on Bond Elut Si cartridges and converted to the trimethylsilyl (TMS) ether. Quantitation was achieved by gas chromatography-negative-ion chemical-ionization tandem mass spectrometry. The precursor ion [M-PFB]- = [P]- carried more than 80% of the total ion current. Collision activated decomposition (CAD) of [P]- resulted in characteristic product ions of which the [P-2(CH3)3SiOH]- ion (PGE1) and the [P-(CH3)3SiOH]- ion (PGE0 and 15-keto-PGE0) were used for quantitation. The lower limit of quantitation (LLQ) was 2 pg/ml (PGE1 and PGE0) and 10 pg/ml (15-keto-PGE0) extracted from 2 ml of human plasma. Linear calibration curves were obtained over the concentration range 2-100 pg/ml (PGE1 and PGE0) and 10-500 pg/ml (15-keto-PGE0). In all cases, the precision and accuracy were < 17%. The present method has been applied successfully to pharmacokinetic and clinical studies in humans.  相似文献   

2.
Koster EH  Bruins CH  de Jong GJ 《The Analyst》2002,127(5):598-602
On-fiber derivatization was used for solid-phase microextraction (SPME) in order to increase the detectability and extractability of drugs in biological samples. Amphetamine, which was used as a model compound, was derivatized with pentafluorobenzoyl chloride (PFBCl) and subjected to gas chromatography with electron capture or mass spectrometric detection. Extraction was performed by direct immersion of a 100 microm polydimethylsiloxane-coated fiber into buffered human urine. On-fiber derivatization was performed either after or simultaneously with extraction. The former procedure gave cleaner chromatograms but the latter turned out to be superior with respect to linearity and repeatability. For the on-fiber derivatization of amphetamine an excess of reagent is required. Because a considerable part of the PFBCl loaded on to the fiber is used up by reaction with matrix compounds and water, a reagent loading time of 5 min was needed to obtain a linear range (r = 0.9756) from 250 pg mL(-1) to 15 ng mL(-1). Due to an interfering matrix compound, the limit of detection was also found to be dependent on the reagent loading time, i.e., the limit of detection for a PFBCl loading time of 5 min is 250 pg mL(-1) whereas that for a 1 min loading time it is 100 pg mL(-1). The relative standard deviation (n = 7) of the method was about 11% at an amphetamine concentration of 1 ng mL(-1). The applicability of the method for the determination of drugs in biological samples is shown.  相似文献   

3.
The anti-diuretic neurohypophysial hormone Vasopressin (Vp) and its synthetic analogue Desmopressin (Dp, 1-desamino-vasopressin) have received considerable attention from doping control authorities due to their impact on physiological blood parameters. Accordingly, the illicit use of Desmopressin in elite sport is sanctioned by the World Anti-Doping Agency (WADA) and the drug is classified as masking agent. Vp and Dp are small (8-9 amino acids) peptides administered orally as well as intranasally. Within the present study a method to determine Dp and Vp in urinary doping control samples by means of liquid chromatography coupled to quadrupole high resolution time-of-flight mass spectrometry was developed. After addition of Lys-Vasopressin as internal standard and efficient sample clean up with a mixed mode solid phase extraction (weak cation exchange), the samples were directly injected into the LC-MS system. The method was validated considering the parameters specificity, linearity, recovery (80-100%), accuracy, robustness, limit of detection/quantification (20/50 pg mL(-1)), precision (inter/intra-day<10%), ion suppression and stability. The analysis of administration study urine samples collected after a single intranasal or oral application of Dp yielded in detection windows for the unchanged target analyte for up to 20 h at concentrations between 50 and 600 pg mL(-1). Endogenous Vp was detected in concentrations of approximately 20-200 pg mL(-1) in spontaneous urine samples obtained from healthy volunteers. The general requirements of the developed method provide the characteristics for an easy transfer to other anti-doping laboratories and support closing another potential gap for cheating athletes.  相似文献   

4.
A sensitive derivatization and extraction method is proposed for the determination of hydroxy-PCBs in urine. Phenolic hydroxyl groups of PCBs were allowed to react with five different reagents such as iodomethane, iodoethane, iodopropane, BSTFA and MTBSTFA. Propylated products at 100 °C for 30 min showed the best sensitivity with mass selective detector. Extraction recoveries and relative standard deviations of hydroxy-PCBs by SPE using C2 column were in the range of 78.0-112.3% and 2.5-9.6%, respectively. Instrumental detection limits for derivatized hydroxy-PCBs were in the range of 1-2 pg and were 10-1000 times more sensitive than those of non-derivatized hydroxy-PCBs. The correlation coefficients of the linear regression curves exceed 0.99, and the intra- and inter-day precisions were evaluated by RSDs within 10% at the concentrations of 0.4 and 4.0 ng/mL.  相似文献   

5.
Clenbuterol (CBL) is a potent beta(2)-adrenoceptor agonist used for the management of respiratory disorders in the horse. The detection and quantification of CBL can pose a problem due to its potency, the relatively low dose administered to the horse, its slow clearance and low plasma concentrations. Thus, a sensitive method for the quantification and confirmation of CBL in racehorses is required to study its distribution and elimination. A sensitive and fast method was developed for quantification and confirmation of the presence of CBL in equine plasma, urine and tissue samples. The method involved liquid-liquid extraction (LLE), separation by liquid chromatography (LC) on a short cyano column, and pseudo multiple reaction monitoring (pseudo-MRM) by electrospray ionization quadrupole time-of-flight tandem mass spectrometry (ESI-QTOF-MS/MS). At very low concentrations (picograms of CBL/mL), LLE produced better extraction efficiency and calibration curves than solid-phase extraction (SPE). The operating parameters for electrospray QTOF and yield of the product ion in MRM were optimized to enhance sensitivity for the detection and quantification of CBL. The quantification range of the method was 0.013-10 ng of CBL/mL plasma, 0.05-20 ng/0.1 mL of urine, and 0.025-10 ng/g tissue. The detection limit of the method was 13 pg/mL of plasma, 50 pg/0.1 mL of urine, and 25 pg/g of tissue. The method was successfully applied to the analysis of CBL in plasma, urine and various tissue samples, and in pharmacokinetic (PK) studies of CBL in the horse. CBL was quantified for 96 h in plasma and 288 h in urine post-administration of CLB (1.6 micro g/kg, 2 x daily x 7 days). This method is useful for the detection and quantification of very low concentrations of CBL in urine, plasma and tissue samples.  相似文献   

6.
A novel analytical approach has been developed and shown to be capable of detecting the isomers of oestradiol in the low ppt (pg mL(-1)) range in bovine serum and urine. Following extractive derivatisation the analytes were detected as their 3-pentafluorobenzoyl 17-trimethylsilyl ether derivatives by gas chromatography-mass spectrometry/mass spectrometry (GC-MS/MS), using electron capture negative ion chemical ionisation. The isomers of oestradiol were quantified in both blank and post-administration urine and serum samples, with a view to setting action/threshold levels for these compounds, to allow discrimination between normal samples and samples from animals treated with growth promoting ear implants. A non-parametric statistical assessment of the data resulted in proposed action levels (with a false positive probability of 1 in 1000) of 1.6 and 2.7 ng mL(-1) for 17alpha-oestradiol, in male and female urine, respectively, and 40 and 44 pg mL(-1) for 17beta-oestradiol, in male and female urine, respectively. An action level of 20 pg mL(-1) was proposed for 17alpha- and 17beta-oestradiol in male serum. In female serum the proposed action levels were 40 and 20 pg mL(-1) for 17alpha- and 17beta-oestradiol, respectively.  相似文献   

7.
A simple, selective and very sensitive assay is described for the quantification of physostigmine in blood, plasma and urine. The most appropriate solid phase column was selected after a systematic investigation of nine types of phase. The conditions for solid phase extraction were optimized using [3H]physostigmine so that the overall recoveries were greater than 90%. Physostigmine was retained on alkaline treated cyanopropyl columns and eluted into the minimum volume of methanol, obviating the need for an evaporation step. Extracted samples were quantified by HPLC with a three electrode coulometric detection system. The limit of detection was 50 pg/mL for a 0.5 mL plasma sample. The precision (CV) for 0.5 mL plasma samples containing 50 pg was 8.1%. Application of the method to plasma, blood and urine samples is presented.  相似文献   

8.
This study reports a simple and rapid high-performance liquid chromatographic (HPLC) method for the determination of the insecticide diazinon (O,O-diethyl-O[2-isopropyl-6-methylpyridimidinyl] phosphorothioate), its metabolites diazoxon (O,O-diethyl-O-2-isopropyl-6-methylpyridimidinyl phosphate) and 2-isopropyl-6-methyl-4-pyrimidinol, the insecticide chlorpyrifos (O,O-diethyl-O[3,5,6-trichloro-2-pyridinyl] phosphorothioate) and its metabolites chlorpyrifos-oxon (O,O-diethyl-O[3,5,6-trichloro-2-pyridinyl] phosphate), and TCP (3,5,6-trichloro-2-pyridinol) in rat plasma and urine samples. The method is based on using C18 Sep-Pak cartridges for solid-phase extraction and HPLC with a reversed-phase C18 column and programmed UV detection ranging between 254 and 280 nm. The compounds are separated using a gradient of 1% to 80% acetonitrile in water (pH 3.0) at a flow rate ranging between 1 and 1.5 mL/min in a period of 16 min. The limits of detection ranged between 50 and 150 ng/mL, and the limits of quantitation were 100 to 200 ng/mL. The average percentage recovery of five spiked plasma samples were 86.3 +/- 8.6, 77.4 +/- 7.0, 82.1 +/- 8.2, 81.8 +/- 8.7, 73.1 +/- 7.4, and 80.3 +/- 8.0 and from urine were 81.8 +/- 7.6, 76.6 +/- 7.1, 81.5 +/- 7.9, 81.8 +/- 7.1, 73.7 +/- 8.6, and 80.7 +/- 7.7 for diazinon, diazoxon, 2-isopropyl-6-methyl-4-pyrimidinol, chlorpyrifos, chlorpyrifos-oxon, and TCP, respectively. The relationship between the peak area and concentration was linear over a range of 200 to 2,000 ng/mL. This method was applied in order to analyze these chemicals and metabolites following dermal administration in rats.  相似文献   

9.
Bisphenol A (BPA) is employed in the synthesis of polycarbonate plastics and epoxy resins and is widely used in consumer products including as a coating for the inside of almost all food and beverage containers and thermal-imaging paper. Bisphenol A is considered to have important health implications because it possesses weak estrogenic activity and can leach from storage containers resulting in its consumption by both humans and animals. It is metabolized in the body and excreted into urine as a glucuronide derivative. In this report, we present an accurate, selective, sensitive, and reproducible high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) method for the quantitation of BPA in human urine, which is not prone to exogenous contamination. BPA-glucuronide is hydrolyzed enzymatically, extracted with toluene, derivatized with dansyl chloride, and the BPA-(dansyl)(2) derivative is analyzed using reversed-phase HPLC/MS/MS. Calibration was linear to 50 ng/mL with a limit of quantitation of 50 pg/mL and a limit of detection of 5 pg/mL.  相似文献   

10.
建立高效液相色谱串联质谱法同时测定大鼠尿液中的6种苯二氮卓类药物(BZDs).以乙酸乙酯为萃取溶剂,经液-液萃取前处理后检测.以地西泮为内标,流动相为甲醇-0.01%甲酸+5 mmol/L甲酸铵,梯度洗脱,柱温为40℃;流速为0.3 mL/min;进样量为2 μL,质谱采用电喷雾离子源正离子模式(ESI+).8-溴-1...  相似文献   

11.
A capillary electrophoretic method for a high-sensitivity analysis of cyanide has been developed. Cyanide was derivatized with 2,3-naphthalenedialdehyde and taurine to give a fluorescent product of 1-cyanobenz[f]isoindole. This compound was detected with high sensitivity by fluorescence detection. The detection limit was 0.1 ng/mL, and the calibration curve was linear over the range 0.1-200 ng/mL. The precision of the migration time of within-run assays (n = 6) of 1 ng/mL cyanide standard solution was 0.14%. The precision of the peak area for the same runs was 1.0%. This method was applicable to blood analysis. Detection of the cyanide derivative by UV was also examined.  相似文献   

12.
A new analytical method for determining 6-chloronicotinic acid (6-ClNA) in human urine is proposed. 6-ClNA is the main metabolite in warm-blooded animals after exposure to the insecticide imidachloprid. 6-ClNA was extracted from human urine using solid phase extraction (SPE) with laboratory-made cartridges of Amberlite XAD-4. A clean-up step and a derivatization process were carried out prior to gas chromatography-tandem mass spectrometric (GC-MS-MS) determination. A study on the influence of pH in the extraction process revealed that it affects the analyte extraction efficiency. A working pH zone was defined between 0.8 and 2.8. Calibration curves were studied in the concentration range of 0.5-100 ng mL(-1) and showed good linearity. Limits of detection and determination of the method were 16 and 56 pg mL(-1) respectively. The mean recovery at 10 and 100 ng mL(-1) was between 97.2 and 102.1% and the repeatability was lower than 5.4% in all cases. The analysis of urine samples of five agricultural workers from Almería (Spain) did not detect the metabolite.  相似文献   

13.
A high through-put miniaturised separation-quantification method for the heterocyclic aromatic amine 2-amino-1-methyl-6-phenylimidazo[4,5-b]pyridine (PhIP) in urine was developed. The limit of detection was of 0.65 fmol (0.14 pg) injected or 65 pM. Heterocyclic aromatic amines are mutagenic and carcinogenic compounds formed at low levels in protein-rich food during cooking. Due to the low concentrations and the high complexity of the matrix in which they exist (food, blood, and urine), and the often small sample volumes (capillary blood; urine, blood and milk from small animals), very sensitive and selective analytical methods are required for their detection. Miniaturization was accomplished by micro solid-phase extraction in capillaries with blue chitin as solid-phase, coupled on-line (in-capillary) to capillary electrophoresis with nanospray tandem mass spectrometric detection. This new technique provided a total analysis time of only 15 min, including extraction and separation, together with low sample and solvent consumption. Blue chitin showed high tolerance towards the urine matrix. Urine collected 12h after consumption of fried chicken contained 1.8 nmol L(-1) (0.40 pg microL(-1)) of PhIP.  相似文献   

14.
A high performance liquid chromatographic (HPLC) method for the analysis of aflatoxin M1 (AFM1) in urine is described. Urine samples were treated with saturated lead acetate and AFM1 was extracted with chloroform. After washing with water to remove impurities the compound was derivatized with trifluoroacetic acid and the AFM1 derivative was analyzed quantitatively by HPLC. The sample pretreatment is simple and more selective. A good line correlation between AFM1 peak height and its concentration was obtained when AFM1 content was in the range of 50-400 pg. The ratio of recovery was 87.42%. Sensitivity is 0.01 ppb. The method is applicable to trace analysis. Results in urine of residents who live in the high/low liver cancer incidence area in Fushui county were the same as that of previous epidemiological investigation.  相似文献   

15.
建立了QuEChERS前处理结合气相色谱-质谱快速测定职业工人尿液中8种多溴联苯醚同系物的分析方法。尿液样在氯化钠和无水硫酸镁的脱水与盐析作用下以正己烷-丙酮混合液提取,采用C18去除提取液中的杂质,并采用气相色谱-负化学源质谱法在选择离子监测模式下测定,内标法定量。三至七溴联苯醚在1~100 pg/μL(十溴联苯醚为10~1 000 pg/μL)范围内线性关系良好,相关系数均大于0.999。待测物在3个加标水平下的平均回收率为91.7%~110.2%,相对标准偏差(RSD)小于10%。多溴联苯醚的检出限为0.3~36 pg/m L。该方法简单快速,灵敏度和选择性较高,适合职业工人体内污染物暴露水平监测。  相似文献   

16.
2CC‐NBOMe {4‐chloro‐2,5‐dimethoxyphenethyl‐N‐[(2‐methoxyphenyl) methyl] ethanamine} and 25I‐NBOMe {2‐(4‐iodo‐2,5‐dimethoxyphenyl)‐N‐[(2‐methoxyphenyl) methyl] ethanamine} are of a class of N‐benzyl phenethylamine derivatives whose synthesis was first reported in the scientific literature in 2011. Recent reports from ‘personal drug experience websites’ and in the popular press indicate these drugs are the latest in a series of designer ‘Bath Salt’ drugs of abuse. The presented high‐performance liquid chromatography triple quadrupole mass spectrometry (HPLC/MS/MS) method was developed for the detection and quantification of 2CC‐NBOMe and 25I‐NBOMe in serum of intoxicated emergency department patients. The assay applies 2‐?(2,?5‐?dimethoxyphenyl)‐?N‐?(2‐?methoxybenzyl) ethanamine (25H‐NBOMe) as the internal standard. Samples were extracted using solid‐phase extraction columns. The chromatographic separation was performed on a Luna 3 µ C8(2) 100 Å, 100 × 2.0 mm, column. Detection was accomplished by multiple‐reaction monitoring via an electrospray ionization source operating in the positive ionization mode. The calibration curves were linear over the investigated concentration range, 30–2000 pg/mL, with a lower limit of detection of 10 pg/mL for both 2CC‐NBOMe and 25I‐NBOMe. The method proved suitable for serum clinical toxicology testing. Two severely intoxicated emergency department patients were determined to have serum concentrations of 250 and 2780 pg/mL of 25I‐NBOMe using the presented method. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

17.
Tobacco‐specific N‐nitrosamines (TSNAs), including N′‐nitrosonornicotine, 4‐(methylnitrosamino)‐1‐(3‐pyridyl)‐1‐butanone, N′‐nitrosoanatabine, and N′‐nitrosoanabasine, have been implicated as a source of carcinogenicity in tobacco and cigarette smoke. We present a rapid and effective method comprising SPE based on tetraazacalix[2]arene[2]triazine‐modified silica as sorbent and analysis with HPLC–MS/MS for the determination of TSNAs and 4‐(methylnitrosamino)‐1‐(3‐pyridyl)‐1‐butanol (NNAL), a metabolite of 4‐(methylnitrosamino)‐1‐(3‐pyridyl)‐1‐butanone, in rabbit plasma. The linear dynamic ranges were 10–2000 pg/mL for NNAL and 4–2000 pg/mL for the four TSNAs with good correlation coefficients (>0.9965). The LODs were in the range of 0.9–3.7 pg/mL, and the LOQs were between 2.9 and 12.3 pg/mL. The accuracies of the method were also evaluated and found to be in the range of 90.1–113.3%. This method is promising to be applied to the preconcentration and determination of TSNAs and NNAL in smoke and human body fluids.  相似文献   

18.
A sensitive high-performance liquid chromatography/electrospray ionization tandem mass spectrometry (MS/MS) method was developed and validated for the simultaneous quantification of trandolapril and its metabolite trandolaprilat in human plasma using ramipril as an internal standard. Following solid-phase extraction, the analytes were separated using an isocratic mobile phase on a reversed-phase column and analyzed by MS/MS in the multiple reaction monitoring mode using the respective [M-H]- ions, m/z 429/168 for trandolapril, m/z 401/168 for trandolaprilat and m/z 415/166 for the internal standard. The method exhibited a linear dynamic range of 20-10,000 pg/mL for both trandolapril and trandolaprilat in human plasma. The lower limit of quantification was 20 pg/mL for both trandolapril and its metabolite. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. A run time of 2.0 min for each sample made it possible to analyze more than 400 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability or bioequivalence studies.  相似文献   

19.
This work relates the development of an analytical methodology to simultaneously determine three methylxanthines (caffeine, theobromine, and theophylline) in beverages and urine samples based on reversed-phase high-performance liquid chromatography. Separation is made with a Bondesil C18 column using methanol-water-acetic acid or ethanol-water-acetic acid (20:75:5, v/v/v) as the mobile phase at 0.7 mL/min. Identification is made by absorbance detection at 273 nm. Under optimized conditions, the detection limit of the HPLC method is 0.1 pg/mL for all three methylxanthines. This method is applied to urine and to 25 different beverage samples, which included coffee, tea, chocolate, and coconut water. The concentration ranges determined in the beverages and urine are: < 0.1 pg/mL to 350 microg/mL and 3.21 microg/mL to 71.2 microg/mL for caffeine; < 0.1 pg/mL to 32 microg mL and < 0.1 pg/mL to 13.2 microg/mL for theobromine; < 0.1 pg/mL to 47 microg/mL and < 0.1 pg/mL to 66.3 microg/mL for theophylline. The method proposed in this study is rapid and suitable for the simultaneous quantitation of methylxanthines in beverages and human urine samples and requires no extraction step or derivatization.  相似文献   

20.
A gas chromatography-microchip atmospheric pressure photoionization-mass spectrometric (GC-μAPPI-MS) method was developed and used for the analysis of three 2-quinolinone-derived selective androgen receptor modulators (SARMs). SARMs were analyzed from spiked urine samples, which were hydrolyzed and derivatized with N-methyl-N-(trimethylsilyl)trifluoroacetamide before analysis. Trimethylsilyl derivatives of SARMs formed both radical cations (M+•) and protonated molecules ([M + H]+) in photoionization. Better signal-to-noise ratios (S/N) were obtained in MS/MS analysis using the M+• ions as precursor ions than using the [M + H]+ ions, and therefore the M+• ions were selected for the precursor ions in selected reaction monitoring (SRM) analysis. Limits of detection (LODs) with the method ranged from 0.01 to 1 ng/mL, which correspond to instrumental LODs of 0.2–20 pg. Limits of quantitation ranged from 0.03 to 3 ng/mL. The mass spectrometric response to the analytes was linear (R ≥ 0.995) from the LOQ concentration level up to 100 ng/mL concentration, and intra-day repeatabilities were 5%–9%. In addition to the GC-μAPPI-MS study, the proof-of-principle of gas chromatography-microchip atmospheric pressure chemical ionization-Orbitrap MS (GC-μAPCI-Orbitrap MS) was demonstrated.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号