首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Summary Room temperature ionic liquids (RTIL) are molten salts with melting points well below room temperature. 1-butyl-3-methylimidazolium chloride is a typical example of such RTIL. It was used as a solvent to dissolve permethylated-β-cyclodextrin (BPM) and dimethylated-?cyclodextrin (BDM) to prepare stationary phases for capillary columns in gas chromatography for chiral separation. The RTIL containing columns were compared to commercial columns containing the same chiral selectors. A set of 64 chiral compounds separated by the commercial BPM column was tested on the RTIL BPM column. Only 21 were enantioresolved. Similarly, a set of 80 compounds separated by the commercial BDM column was passed on the RTIL BDM column with only 16 positive separations. It is proposed that the imidazolium ion pair could make an inclusion complex with the cyclodextrin cavity, blocking it for chiral recognition. All the chiral compounds recognized by the RTIL columns had their asymmetric carbon that was part of a ring structure. The retention factors of the derivatized solutes were lower on the RTIL columns than those obtained on the commercial equivalent column. The peak efficiencies obtained with the RTIL capillary were significantly higher than that obtained with the commercial column. These observations may contribute to the knowledge of the mechanism of cyclodextrin-based GC enantioselective separations.  相似文献   

2.
Chen Z  Ozawa H  Uchiyama K  Hobo T 《Electrophoresis》2003,24(15):2550-2558
We describe beta- and gamma-cyclodextrins (beta- and gamma-CD)-modified monolithic columns prepared by sol-gel process and chemical modifications. The monolithic silica column was fabricated inside a fused-silica capillary with 100 microm inner diameter by sol-gel process. The monolithic silica matrix was chemically modified chiral selectors of beta- or gamma-CDs with a spacer of 3-glycidoxypropyltrimethoxysilane by on-column reactions. Gamma-CD-modified monolithic column has successfully been applied for the separation of dansyl amino acid enantiomers. Beta-CD-modified monolithic column has been used for the separation of the positional isomers of o-, m-, and p-cresols and the enantioseparation of racemates of benzoin and several dansyl amino acids by capillary electrochromatography, respectively. For the separation of neutral positional isomers, a positive electric field was applied. However, for the separation of negatively charged analytes, a negative electric field was applied at the inlet of column. The separation efficiency of 5.0 x 10(4) theoretical plates/m for dansyl-L-threonine was obtained at electric field strength of -300 V/cm in the mobile phase of 50 mM 2-(N-morpholino)ethanesulfonic acid (MES)-Tris/methanol (70/30) buffer at pH 7.0. L-enantiomers were eluted as the first peak. Scanning electron micrograph showed that monolithic columns have the morphology of continuous skeleton and large through-pores.  相似文献   

3.
Wang Y  Zeng Z  Guan N  Cheng J 《Electrophoresis》2001,22(11):2167-2172
A novel open-tubular capillary electrochromatography (OT-CEC) column coated with 2,6-dibutyl-beta-cyclodextrin (DB-beta-CD) was prepared using sol-gel technique. In the sol-gel approach, owing to the three-dimensional network of sol-gel and the strong chemical bond between the stationary phase and the surface of capillary columns, good chromatographic characteristics and unique selectivity in separating isomers were shown. We achieved high efficiencies of 5-14 x 10(4) plates/m for the isomeric nitrophenols using the sol-gel-derived DB-beta-CD columns. The migration time reproducibility of the separation of the isomeric nitrophenols was better than 2.2% over five runs and 4.5% from column to column. These sol-gel-coated DB-beta-CD columns have shown improved separations of isomeric aminophenols, isomeric dihydroxybenzenes and isomeric nitrophenols, in comparison with the sol-gel matrix capillary column. The influences of buffer pH and methanol solvent on separation were investigated. The chiral resolution of enantiomers such as ibuprofen and binaphthol was explored primarily.  相似文献   

4.
Molecular organic cages as shape-persistent organic molecules with permanent and accessible cavities have attracted a lot of interest because of their importance as host-guest systems. Herein, we report a chiral porous organic cage (POC) CC9 diluted with a polysiloxane OV-1701 to fabricate a CC9-coated capillary column, which was used for the high-resolution gas chromatographic separation of organic compounds, including positional isomers and racemates. On the CC9-coated capillary column, a large number of racemic compounds such as chiral alcohols, esters, ethers and epoxides can be resolved without derivatization. By comparing the chiral recognition ability of the CC9-coated column with the commercially available β-DEX 120 column and the POC CC3-R coated column recently reported by our group, the CC9-coated column offered good resolution during the separation of some racemates, that were not separated using the β-DEX 120 column or POC CC3-R coated column. Therefore, the CC9-coated column can be complementary to the β-DEX 120 column and CC3-R coated column. The results indicated that the CC9-coated column exhibited great potential for application in the separation of positional isomers and enantiomers with great selectivity, high resolution and good reproducibility.  相似文献   

5.
The ionic liquid SLB-IL111 column, available from Supelco Inc., is a novel fused capillary gas chromatography (GC) column capable of providing enhanced separations of fatty acid methyl esters (FAMEs) compared to the highly polar cyanopropyl siloxane columns currently recommended for the separation of cis- and trans isomers of fatty acids (FAs), and marketed as SP-2560 and CP-Sil 88. The SLB-IL111 column was operated isothermal at 168°C, with hydrogen as carrier gas at 1.0 mL/min, and the elution profile was characterized using authentic GC standards and synthetic mono-unsaturated fatty acids (MUFAs) and conjugated linoleic acid (CLA) isomers as test mixtures. The SLB-IL111 column provided an improved separation of cis- and trans-18:1 and cis/trans CLA isomers. This is the first direct GC separation of c9,t11- from t7,c9-CLA, and t15-18:1 from c9-18:1, both of which previously required complimentary techniques for their analysis using cyanopropyl siloxane columns. The SLB-IL111 column also provided partial resolution of t13/t14-18:1, c8- from c6/c7-18:1, and for several t,t-CLA isomer pairs. This column also provided elution profiles of the geometric and positional isomers of the 16:1, 20:1 and 18:3 FAMEs that were complementary to those obtained using the cyanopropyl siloxane columns. However, on the SLB-IL111 column the saturated FAs eluted between the cis- and trans MUFAs unlike cyanopropyl siloxane columns that gave a clear separation of most saturated FAs. These differences in elution pattern can be exploited to obtain a more complete analysis of complex lipid mixtures present in ruminant fats.  相似文献   

6.
将β-环糊精的2,6-位引入乙氧乙基,3-位引入三氟乙酰基,合成了新的环糊精衍生物2,6-二-O-乙氧乙基-3-O-三氟乙酰基-β-环糊精,并采用静态法涂渍毛细管气相色谱柱,考察了毛细管柱的柱性能和分离性能。结果表明,该固定相对G rob试剂、苯的二取代位置异构体氯甲苯、硝基甲苯和溴甲苯以及10种手性化合物如α-取代丙酸酯化合物、1-(2′-硝基苯基)-乙醇、α-甲基-对氯苯乙腈和丙炔醇酮乙酸酯等具有良好的分离效果。其中,对α-甲磺酰基丙酸酯对映体的拆分效果最好;对α-取代丙酸的甲酯衍生物的分离效果优于乙酯衍生物;对α-羟基取代丙酸酯的分离效果优于α-卤代丙酸酯。  相似文献   

7.
A number of chiral oxime compounds have been synthesised and their gas chromatographic analysis on both a polyethelene glycol phase column and two chiral column phases was investigated. Of particular interest to this work is the observation of dynamic interconversion behaviour, both in a single dimensional analysis, and by using comprehensive two-dimensional gas chromatography (GC × GC). A number of non-chiral compounds were studied as a means to understand the nature of the behaviour observed. As expected, the achiral compound on both the wax column and the chiral column generated two isomeric compounds—the E and Z isomers. On the wax column, a characteristic interconversion zone representing the dynamic process was observed, with extent of interconversion dependent on the conditions used. For the chiral compounds, two isomers and the interconversion zone were exhibited on the wax column, however on the chiral column 4 isomeric peaks were found—the (R) and (S) enantiomers of each of the E and Z isomers. In the case of the chiral column, the extent of interconversion was negligible, and this appears to correlate with the use of low polarity columns. In order to encourage dynamic interconversion, a polyethylene glycol column was coupled to the chiral column, by placing it either before or after the chiral column. In this case a monitor detector was employed between the two columns in order to isolate the effects of the first column from the behaviour on the second. In a further study, the most appropriate column arrangement from the earlier study was placed into a comprehensive two-dimensional gas chromatography instrument, with a wax-phase column in the second dimension. The unique location of peaks for each of the molecules in 2D space and patterns for the interconversion processes is interpreted phenomenologically.  相似文献   

8.
Three commercially available chiral capillary columns, Chirasil-Dex, BGB-176SE, and BGB-172, have been evaluated for the separation into enantiomers of the 19 chiral polychlorinated biphenyls (PCB) congeners stable at room temperature. The enantiomers of 15 chiral PCBs were, at least to some extent, separated using these beta-cyclodextrin based columns. Multidimensional techniques, such as heart-cut multi-dimensional gas chromatography (heart-cut MDGC) and comprehensive two-dimensional gas chromatography (GC x GC), were investigated for their ability to solve coelution problems with other PCBs present in commercial mixtures and real-life samples. Heart-cut MDGC improved the separation as compared to one-dimensional GC, and enantiomeric fractions of the investigated chiral PCBs could be determined free from interferences. However, limitations on the number of target compounds that can be transferred to the second column in a single run and, therefore, the time consumption, have led to the evaluation of GC x GC as an alternative for this type of analysis. With GC x GC, two column set-ups were tested, both having a chiral column as first-dimension column, and two different polar stationary phase columns in the second dimension. On using both column combinations, congeners 84, 91, 95, 132, 135, 136, 149, 174, and 176 could be determined free from coelutions with other PCBs. Results on the application of heart-cut MDGC to food samples such as milk and cheese are given, as well as the first results on the application of GC x GC to this type of samples.  相似文献   

9.
合成了一种手性离子液体L-丙氨酸叔丁酯双三氟甲烷磺酰亚胺(L-AlaC4NTf2), 将其作为新型气相色谱固定相, 并与OV-1701按不同比例混合, 考察了它们的色谱性能. 研究结果表明, 该离子液体作为手性固定相的热稳定性高于175 ℃; 平均McReynolds常数为665; 在容量因子为1.02时, 理论塔板数可达每米1095块; 其对烷烃、醇类、酮类、芳香族化合物、位置异构体以及一些手性化合物具有良好的分离效果.  相似文献   

10.
Porous organic cages composed of discrete cage molecules have attracted considerable recent attention as gas adsorption materials and separation media. In this study, we report a homochiral porous organic cage CC5 with a large cavity and pore windows as a novel stationary phase for high‐resolution gas chromatographic separations. The capillary column was prepared by a static coating method. A large number of racemic compounds have been resolved on the coated capillary column, including derivatized amino acids, alcohols, alcohol amines, esters, ethers, ketones, and epoxides. It is interesting that the CC5‐coated capillary column exhibits significant chiral recognition complementarity to a commercial β‐DEX 120 column and a previously reported homochiral porous organic cage CC3‐R‐coated column, which could expand the range of the analytes amenable to separation on porous organic cage‐based capillary columns. Moreover, the fabricated column also shows excellent selectivity for the separation of positional isomers, including the challenging ethylbenzene and xylene isomers. Experimental results demonstrate an excellent separation performance and stability of the CC5‐coated column, making it promising for gas chromatography applications.  相似文献   

11.
This work reports the preparation of monolithic zirconia chiral columns for separation of enantiomeric compounds by capillary electrochromatography (CEC). Using sol–gel technology, a porous monolith having interconnected globular-like structure with through-pores is synthesized in the capillary column as a first step in the synthesis of monolithic zirconia chiral capillary columns. In the second step, the surface of the monolith is modified by coating with cellulose tris(3,5-dimethylphenylcarbamate) (CDMPC) as the chiral stationary phase to obtain a chiral column (CDMPCZM). The process of the preparation of the zirconia monolithic capillary column was investigated by varying the concentrations of the components of the sol solution including polyethylene glycol, water and acetic acid. CDMPCZM is mechanically stable and no bubble formation was detected with the applied current of up to 30 μA. The enantioseparation behavior of the CDMPCZM columns was investigated by separating a set of 10 representative chiral compounds by varying the applied voltage and pH and organic composition of the aqueous organic mobile phases.  相似文献   

12.
Chiral covalent organic frameworks(CCOFs) featuring chirality, stability, and good porosity have attracted a considerable amount of attention due to their important applications, such as asymmetric catalysis, chiral separation, and chiral recognition. In this study, a β-cyclodextrin(β-CD) covalent organic framework(β-CD-COF) diluted with polysiloxane OV-1701 was explored as a novel chiral stationary phase(CSP) for gas chromatography(GC) separation of racemates. The β-CD-COF coated capillary colu...  相似文献   

13.
This work investigated the repeatability of column preparation for a reversed-phase C18 monolith, namely stearyl methacrylate-co-ethylene glycol dimethacrylate (SMA-EDMA). The columns were thermally polymerised using three commonly available heating devices (GC oven, hot air oven and water bath) and their chromatographic performance evaluated using micro-liquid chromatography for separation of five test compounds. Precision in terms of %RSD of retention times were 9.0, 6.5, and 12.5 using GC oven, hot air oven and water bath, respectively. Between-batch precision for the hot air oven (n = 3 days) was less than 10.4% for retention time. The SMA-EDMA monolith was applied to the separation of tocopherol homologues by capillary electrochromatography. Usually tocopherol homologues cannot be completely separated by conventional reversed-phase C8- or C18-packed bed or C18-silica based monolithic columns. Polymer monolith has been shown to give remarkable selectivity towards the tocopherols compared to the conventional microparticulate phase and silica based monolith. Successful separation of the tocopherol isomers was achieved on the SMA-EDMA monolith without any column modification.  相似文献   

14.
Two-stage capillary GC with two-stage retention index monitoring is an efficient analytical technique which can be used for detection and determination of small amounts of volatile compounds in complex mixtures of hundreds or thousands of other compounds. The system employs two capillary columns, coated with different stationary phases, connected on-line with the aid of a micro valve; the first column acts as a pre-separating unit from which unresolved fractions of interest are cut (transferred) into another column for final, interference-free separation of the compounds to be determined. This technique has been compared with selected ion monitoring capillary GC-MS using a hydrocarbon mixture as a test sample for comparing resolution, repeatability, and the practical usefulness of the techniques. Results indicate that two-stage capillary GC is very useful for mixtures containing compounds which produce mostly non-specific ions in the MS ion source whereas compounds producing specific ions can be easily analyzed by capillary GC – single ion monitoring MS even if they are not perfectly separated by a single capillary column.  相似文献   

15.
Microporous organic networks (MONs) are a new class of porous materials synthesized via Sonogashira coupling reactions between organic building blocks. Here we report an in situ synthesis approach to fabricate MONs coated capillary column for high resolution GC separation of hydrocarbons. The McReynolds constant evaluation reveals the MONs coated capillary is a non‐polar column. The MONs coated capillary column shows good resolution for GC separation of diverse important industrial hydrocarbons such as linear and branched alkanes, alkylbenzenes, pinene isomers, ethylbenzene and styrene, cyclohexane and benzene. The MONs coated capillary column gave a high column efficiency of 1542 plates per meter for hexane and good precision for replicate separations of the selected hydrocarbons with the RSDs of 0.2–0.3, 1.5–3.1, and 1.9–3.3% for retention time, peak height and peak area, respectively. The MONs coated capillary also offered better resolution than commercial Inert Cap‐1 and Inert Cap‐5 capillary columns for hexane and heptane isomers. These results reveal the potential of MONs as novel stationary phases in GC.  相似文献   

16.
Comprehensive two-dimensional gas chromatography (GC x GC) coupled to time-of-flight mass spectrometry (TOF-MS) was applied to improve the separation of 4-nonylphenol isomers and their biodegradation products. The structurally similar nonylphenol isomers were separated by combining a 30 m long semi-polar column and a short polar capillary. Both were coupled via a custom-made liquid nitrogen cryogenic modulator. The advanced GC resolution of coeluting isomers, additionally supported by fast scanning TOF-MS, provided clearer, non-interfered mass spectra of individual isomers. Thus, identification of components is facilitated as shown for isomeric 4-nonylphenols and metabolites of their biodegradation by Clavariopsis aquatica, an aquatic fungus. GC x GC-TOF-MS analysis enabled the separation of about 40 alkylphenol isomers included in technical 4-nonylphenol. During biodegradation the variety of emerging compounds increased with longer reaction time. The comprehensive analysis indicated a broad spectrum of hydroxylated, carboxylated nonylphenolisomers and additionally, chlorinated aromatic compounds produced and released from the fungal culture.  相似文献   

17.
李正名  么恩云 《有机化学》1985,5(6):443-449
采用涂布手性固定相的毛细管柱在气相色谱上进行手性化合物对映体的分离是近年发展起来的一种简便、快速分析的新方法。本文就分离机理,手性化合物的衍生化,构型分析和光学活性固定相等四个方面的新进展进行综述和讨论。  相似文献   

18.
An overview upon modern analytical techniques for the isolation, separation, and structural identification of the essential bioactive carotenoid bixin is given. Isolation from biological matrices is performed by matrix solid phase dispersion (MSPD). The extract is separated with shape-selective C(30 )columns. Structural assignment of the separated compounds is done by online LC-MS and capillary HPLC-NMR.  相似文献   

19.
The separation of 17 chiral sulfoxides and eight chiral sulfinate esters by gas chromatography (GC) on four derivatized cyclodextrin chiral stationary phases (CSPs) (Chiraldex G-TA, G-BP, G-PN, B-DM) is presented. Many of these compounds are structural isomers or part of a homologous series. Differences in enantioselectivity of the methyl phenyl sulfoxide isomers on the derivatized gamma cyclodextrin and the heptakis 2,6-di-O-methyl-beta-cyclodextrin (i.e. B-DM) CSPs are discussed. Under the conditions of this study, the molecular mass cut-off for the GC separation of these compounds was approximately 230. Compounds of higher molecular mass were not eluted from the CSPs at reasonable times and temperatures, but these higher molecular mass enantiomers can be separated by liquid chromatography and capillary electrophoresis. The enantiomeric separation and elution order of a sulfinate ester containing two stereogenic centers as well as 15 chiral sulfoxides is presented. The G-TA and B-DM CSPs generally gave opposite elution orders for most of the compounds studied.  相似文献   

20.
Summary Liquid and gas chromatographic separations of the pyrethroid insecticides allethrin and cypermethrin have been investigated with various achiral and chiral stationary phases. Diastercomeric and enantiomeric selectivity was observed for cypermethrin on a Pirkle-type chiral LC stationary phase, but very strong interactions and therefore long retention times prevented the separation of allethrin on this phase. Trans-allethrin isomers were separated on a chiral -cyclodextrin RP-HPLC column while cypermethrin showed some difficulties on this phase due to isomerization. Diastereomeric but no enantiomeric selectivity by GC was achieved for cypermethrin with an apolar DB 5 capillary. GC separation of the diastereomers was used to study the selective photodegradation of cypermethrin isomers after forestry applications. Chiral -cyclodextrin-based GC phases showed some enantioselectivity for cis- and trans-allethrin isomers. A separation of the eight isomers into six partially resolved peaks was achieved by GC with a coupled column consisting of chiral permethylated -cyclodextrin and DB 1701 as stationary phases. This combination was used to characterize allethrin formulations intended for indoor use and to investigate allethrin products formed by ozonolysis of thin films of the insecticide.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号