首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Sample injection in microchip-based capillary zone electrophoresis (CZE) frequently rely on the use of electric fields which can introduce differences in the injected volume for the various analytes depending on their electrophoretic mobilities and molecular diffusivities. While such injection biases may be minimized by employing hydrodynamic flows during the injection process, this approach typically requires excellent dynamic control over the pressure gradients applied within a microfluidic network. The current article describes a microchip device that offers this needed control by generating pressure gradients on-chip via electrokinetic means to minimize the dead volume in the system. In order to realize the desired pressure-generation capability, an electric field was applied across two channel segments of different depths to produce a mismatch in the electroosmotic flow rate at their junction. The resulting pressure-driven flow was then utilized to introduce sample zones into a CZE channel with minimal injection bias. The reported injection strategy allowed the introduction of narrow sample plugs with spatial standard deviations down to about 45 μm. This injection technique was later integrated to a capillary zone electrophoresis process for analyzing amino acid samples yielding separation resolutions of about 4–6 for the analyte peaks in a 3 cm long analysis channel.  相似文献   

2.
Li Y  DeVoe DL  Lee CS 《Electrophoresis》2003,24(1-2):193-199
Isoelectric focusing (IEF) separations, in general, involve the use of the entire channel filled with a solution mixture containing protein/peptide analytes and carrier ampholytes for the creation of a pH gradient. Thus, the preparative capabilities of IEF are inherently greater than most microfluidics-based electrokinetic separation techniques. To further increase sample loading and therefore the concentrations of focused analytes, a dynamic approach, which is based on electrokinetic injection of proteins/peptides from solution reservoirs, is demonstrated in this study. The proteins/peptides continuously migrate into the plastic microchannel and encounter a pH gradient established by carrier ampholytes originally present in the channel for focusing and separation. Dynamic sample introduction and analyte focusing in plastic microfluidic devices can be directly controlled by various electrokinetic conditions, including the injection time and the applied electric field strength. Differences in the sample loading are contributed by electrokinetic injection bias and are affected by the individual analyte's electrophoretic mobility. Under the influence of 30 min electrokinetic injection at constant electric field strength of 500 V/cm, the sample loading is enhanced by approximately 10-100 fold in comparison with conventional IEF.  相似文献   

3.
Morales MC  Lin H  Zahn JD 《Lab on a chip》2012,12(1):99-108
Sample pre-concentration can be a critical element to improve sensitivity of integrated microchip assays. In this work a converging Y-inlet microfluidic channel with integrated coplanar electrodes was used to investigate transverse DNA and protein migration under uniform direct current (DC) electric fields to assess the ability to concentrate a sample prior to other enzymatic modifications or capillary electrophoretic separations. Employing a pressure-driven flow to perfuse the microchannel, negatively charged samples diluted in low and high ionic strength buffers were co-infused with a receiving buffer of the same ionic strength into a main daughter channel. Experimental results demonstrated that, depending of the buffer selection, different DNA migration and accumulation dynamics were seen. Charged analytes could traverse the channel width and accumulate at the positive bias electrode in a low electroosmotic mobility, high electrophoretic mobility, high ionic strength buffer or migrated towards an equilibrium position within the channel in a high electroosmotic mobility, high electrophoretic mobility, low ionic strength buffer. The various migration behaviours are the result of a balance between the electrophoretic force and a drag force induced by a recirculating electroosmotic flow generated across the channel width due to the bounding walls. Under continuous flow conditions, DNA samples were concentrated several-fold by balancing these transverse electrokinetic forces. The electrokinetic trapping technique presented here is a simple technique which could be expanded to concentrate or separate other analytes as a preconditioning step for downstream processes.  相似文献   

4.
A microchip structure for field amplification stacking (FAS) was developed, which allowed the formation of comparatively long, volumetrically defined sample plugs with a minimal electrophoretic bias. Up to 20-fold signal gains were achieved by injection and separation of 400 microm long plugs in a 7.5 cm long channel. We studied fluidic effects arising when solutions with mismatched ionic strengths are electrokinetically handled on microchips. In particular, the generation of pressure-driven Poiseuille flow effects in the capillary system due to different electroosmotic flow velocities in adjacent solution zones could clearly be observed by video imaging. The formation of a sample plug, stacking of the analyte and subsequent release into the separation column showed that careful control of electric fields in the side channels of the injection element is essential. To further improve the signal gain, a new chip layout was developed for full-column stacking with subsequent sample matrix removal by polarity switching. The design features a coupled-column structure with separate stacking and capillary electrophoresis (CE) channels, showing signal enhancements of up to 65-fold for a 69 mm long stacking channel.  相似文献   

5.
It is well known that sample introduction via electrokinetic mode leads to a bias in conventional CE, which is proportional to the difference of electrophoretic mobilities between species. In electrophoretic separation chips using the gated injection mode, flow distribution at the crossjunction, which is linked to the electric field strength distribution during the loading step, induces an additional contribution to species discrimination. This second-order bias has a similar effect on quantitation like usual electrokinetic bias: the higher the analyte's apparent mobility, the larger the amount injected into the separation channel. The present paper assesses by numerical simulations the influence of several parameters, namely the injected amount, the electric field distribution, and the analyte-apparent Peclet number on this second-order bias.  相似文献   

6.
An interface design is presented that facilitates automated sample introduction into an electrokinetic microchip, without perturbing the liquids within the microfluidic device. The design utilizes an interface flow channel with a volume flow resistance that is 0.54-4.1 x 10(6) times lower than the volume flow resistance of the electrokinetic fluid manifold used for mixing, reaction, separation, and analysis. A channel, 300 microm deep, 1 mm wide and 15-20 mm long, was etched in glass substrates to create the sample introduction channel (SIC) for a manifold of electrokinetic flow channels in the range of 10-13 microm depth and 36-275 microm width. Volume flow rates of up to 1 mL/min were pumped through the SIC without perturbing the solutions within the electrokinetic channel manifold. Calculations support this observation, suggesting a leakage flow to electroosmotic flow ratio of 0.1:1% in the electrokinetic channels, arising from 66-700 microL/min pressure-driven flow rates in the SIC. Peak heights for capillary electrophoresis separations in the electrokinetic flow manifold showed no dependence on whether the SIC pump was on or off. On-chip mixing, reaction and separation of anti-ovalbumin and ovalbumin could be performed with good quantitative results, independent of the SIC pump operation. Reproducibility of injection performance, estimated from peak height variations, ranged from 1.5-4%, depending upon the device design and the sample composition.  相似文献   

7.
Hybrid microfluidic/nanofluidic devices offer unique capabilities for manipulating and analyzing minute volumes of expensive or hard-to-obtain samples. Here, multilayer poly-(methyl methacrylate) microchips, with multiple spatially isolated microfluidic channels interconnected by nanocapillary array membranes (NCAMs), are fabricated using an adhesive contact printing process. The NCAMs, positioned between the microfluidic channel layers, add functionality to the inter-microchannel fluid transfer unit operation. They do so because the transport of specific analytes through the NCAM can be controlled by adjusting the ionic strength, the polarity of the applied bias, the surface charge density, and the pore size. A simplified, floating injection technique for NCAM-coupled nanofluidic devices is described and compared with conventional biased injection. In the floating injection approach, a voltage is applied across the injection channel and the slight electric field extension at the cross-section is used to transfer analytes through the nanopores to the separation channel. Floating injection excels in plug reproducibility, separation resolution, and operation simplicity, although it decreases assay throughput relative to biased injection. Floating injection can avoid the uneven distribution of analytes in the microfluidic channel that sometimes results from biased injection because of the volume mismatch between NCAM nanopore transport capacity and the supply of fluid. Moreover, the pressure-driven flow caused by the mismatch of the EOFs in the microfluidic channels connected by an NCAM must be considered when using NCAMs with pore diameters below 50 nm.  相似文献   

8.
Liu J  Yang S  Lee CS  DeVoe DL 《Electrophoresis》2008,29(11):2241-2250
In situ photopolymerized polyacrylamide (PAAm) gel plugs are used as hydrodynamic flow control elements in a multidimensional microfluidic system combining IEF and parallel SDS gel electrophoresis for protein separations. The PAAm gel plugs offer a simple method to reduce undesirable bulk flow and limit reagent/sample crosstalk without placing unwanted constraints on the selection of separation media, and without hindering electrokinetic ion migration in the complex microchannel network. In addition to improving separation reproducibility, the discrete gel plugs integrated into critical regions of the chip enable the use of a simple pressure-driven sample injection method which avoids electrokinetic injection bias. The gel plugs also serve to greatly simplify operation of the spatially multiplexed system by eliminating the need for complex external fluidic interfaces. Using an FITC-labeled Escherichia coli cell lysate as a model system, the use of gel plugs is shown to significantly enhance separation reproducibility in a chip containing five parallel CGE channels, with an average variance in peak elution time of only 4.1%.  相似文献   

9.
The ability to accurately inject small volumes of sample into microfluidic channels is of great importance in electrophoretic separations. While electrokinetic injection of nanoliter scale volumes is commonly utilized in microchip capillary electrophoresis (MCE), mobility and matrix bias makes quantitation difficult. Herein, we describe a new injection method based on the simple patterning of the crossing of channels that does not require sophisticated instrumentation. The sample volume injected into the separation channel is dependent on the ratio of the widths of the crossing channels. This injection method is capable of introducing, into a separation channel, multiple plugs of sample on a large scale. This injection technique is tested for zone electrophoresis in native and surface modified poly(dimethylsiloxane) (PDMS) chips.  相似文献   

10.
Electric field gradient focusing   总被引:1,自引:0,他引:1  
Electric field gradient focusing (EFGF) is a relatively new separation technique with promising attributes, particularly for protein analysis. The fundamental fractionation mechanism in EFGF involves a gradient in electric field along the length of a separation column. The electrophoretic force that drives charged analytes in a region of changing electric field is opposed by a constant, pressure-driven bulk fluid flow. When the electrophoretic velocity of a particular moiety is equal and opposite to the velocity of the fluid flow, the analyte focuses into a stationary band. Thus, EFGF can both concentrate and separate charged species according to electrophoretic mobility. To date, the electric field gradients needed for EFGF have been established using a number of different approaches, including channels having changing cross-sectional areas, conductivity gradients caused by the diffusion of buffer ions across a membrane, electrode arrays, and temperature gradients in buffers whose conductivities change as a function of temperature. EFGF has proven particularly effective for sample enrichment, with concentration factors of 10,000 reported. In this article we review advances in EFGF technology and discuss prospects for further improving EFGF for chemical analysis.  相似文献   

11.
Johann R  Renaud P 《Electrophoresis》2004,25(21-22):3720-3729
Selective transport and sorting of particles in microfluidic devices by electroosmosis is complicated due to superposition of uncontrolled hydrodynamic pressure contributions on the electroosmotic force. In this paper, we present a microfluidic concept for the reliable and simple separation and sorting of particles in a microchip by electroosmosis combined with pressure-driven flow. The presented device allows fluid quantities to be switched and particles to be sorted within a channel manifold using only a single power supply with fixed voltage and an electric switch. Consequently, chip operation and fluid switching procedure are greatly simplified compared to a situation, in which several independent power sources are used for flow balancing, as is the common procedure. With the triple-T channel design presented, backpressure flow disturbing the electrokinetic fluid and particle separation process is eliminated by introducing controlled opposed hydrodynamic flow of buffer from side channels. This pressure-driven flow is generated on-chip by setting up differences in the reservoir pressures in a defined manner. A detailed flow analysis based on the equivalence of fluid flow and electric current is performed and the conditions for reliable chip function are worked out.  相似文献   

12.
A novel pressure-driven sample injection method was developed as an alternative to electrokinetic injection, and electrophoretic separation was carried out on a microfabricated device employing this method. This method enables a defined volume of liquid dispensing, followed by instantaneous injection driven by pneumatic pressure, greatly simplifying the injection procedure. A particular microstructure, called a "metering chamber", has been designed for the quantitative dispensing of an ultra-low volume of sample liquid; a "hydrophobic passive valve" equipped with an air vent channel is employed for injecting a dispensed sample into the separation channel. The reproducibility of dispensing was 3.3% (n = 15), expressed by the variation of dispensed volumes. The electrophoretic separation of DNA fragments was performed using this injection method, varying the injection volumes from 0.45 to 4.0 nL, and the separation efficiencies were compared. This precise injection method, easily variable in injection volumes, is highly suitable for quantitative as well as qualitative electrophoretic analyses.  相似文献   

13.
Dielectrophoresis is an electrokinetic phenomenon that utilizes an asymmetric electric field to separate analytes based on differences in their polarizabilities relative to that of the suspending medium. One dielectrophoretic device architecture that offers interesting possibilities for particle transport without the use of external flow is the ratchet geometry. This paper describes the fabrication and evaluation of a novel dielectrophoretic ratchet device using a series of fine particles as test probes. The asymmetrical electric field required to selectively transport target analytes was produced using electroformed electrodes which offer the possibility of reducing convective heating and which can be used to construct a device in which all particles located within the fluidic channel are exposed to the applied field. Initial tests of this device were conducted using magnetite and polystyrene fine particles to demonstrate selective particle collection and a separation based on differences in the electrical properties of the analytes employed.  相似文献   

14.
In this paper, a micromixer of a new configuration is presented, consisting of a spherical chamber in the center of which an ion-selective microsphere is placed. Stratified liquid is introduced through the chamber via inlet and outlet holes under an external pressure gradient and an external electric field is directed in such a way that the resulting electroosmotic flow is directed against the pressure-driven flow, resulting in mixing. The investigation is carried out by direct numerical simulation on a super-computer. Optimal values of the applied electric field are determined to yield strong mixing. Above this optimal mixing regime, a number of instabilities and bifurcations are realized, which qualitatively coincide with those occurring during electrophoresis of an ion-selective microgranule. As shown by our calculation, these instabilities do not lead to an enhanced mixing. The resulting electroconvective vortices remain confined near the surface of the microgranule, and do not sufficiently perturb the stratified fluid flow further from the granule. On the other hand, another type of instability caused by the salt concentration gradient can generate sufficiently strong oscillations to enhance mixing. However, this only occurs when the external electric field is sufficiently high that the electroosmotic flow is comparable to the pressure-driven flow. This ultimately leads to creation of reverse flows of the liquid and cessation of the device operation. Thus, it was shown that the best mixing occurs in the absence of electrokinetic instability. Based on the data obtained, it is possible to select the necessary geometric characteristics of the micromixer to achieve the optimal mixing mode for a given set of liquids, which may be ten times more effective than passive mixers at the same flow rates. A comparison with the experimental data of the other authors confirms the effectiveness of this device and its other capabilities. Furthermore, the basic device design can be operated in other modes, for example, an electrohydrodynamic pump, a streaming current generator, or even a micro-reactor, depending on the system parameters and choice of an ion-selective granule.  相似文献   

15.
Advancement in rapid targeted chemical analysis of homemade and improvised explosive devices is critical for the identification of explosives-based hazards and threats. Gradient elution moving boundary electrophoresis (GEMBE), a robust electrokinetic separation technique, was employed for the separation and detection of common inorganic oxidizers from frequently encountered fuel-oxidizer mixtures. The GEMBE system incorporated sample and run buffer reservoirs, a short capillary (5 cm), an applied electric field, and a pressure-driven counterflow. GEMBE provided a separation format that allowed for continuous injection of sample, selectivity of analytes, and no sample cleanup or filtration prior to analysis. Nitrate, chlorate, and perchlorate oxidizers were successfully detected from low explosive propellants (e.g., black powders and black powder substitutes), pyrotechnics (e.g., flash powder), and tertiary explosive mixtures (e.g., ammonium nitrate- and potassium chlorate-based fuel-oxidizer mixtures). Separation of these mixtures exhibited detection without interference from a plethora of additional organic and inorganic fuels, enabled single particle analysis, and demonstrated semiquantitative capabilities. The bulk counterflow successfully excluded difficult components from fouling the capillary, yielding estimated limits of detection down to approximately 10 μmol/L. Finally, nitrate was separated and detected from postblast debris collected and directly analyzed from two nitrate-based charges.  相似文献   

16.
The influence of a high electric field applied on both fluid flow and particle velocities is quantified at large Peclet numbers. The experiments involved simultaneous particle image velocimetry and flow rate measurements. These are conducted in polydimethylsiloxane channels with spherical nonconducting polystyrene particles and DI water as the background flow. The high electric field tests produced up to three orders of magnitude higher electrokinetic velocities than any previous reports. The maximum electroosmotic velocity and electrophoretic velocity measured were 3.55 and 2.3 m/s. Electrophoretic velocities are measured over the range of 100 V/cm < E < 250 000 V/cm. The results are separated according to the different nonlinear theoretical models, including low and high Peclet numbers, and weak and strong concentration polarization. They show good agreement with the models. Such fast velocities could be used for flow separation, mixing, transport, control, and manipulation of suspended particles as well as microthrust generation among other applications.  相似文献   

17.
In the present study, controlled protein adsorption on a rigid silica microparticle is investigated numerically using classical Langmuir and two-state models under electrokinetic flow conditions. The instantaneous particle locations are simulated along a straight microchannel using an arbitrary Lagrangian−Eulerian framework in the finite element method for the electrophoretic motion of the charged particle. Within the scope of the parametric study, the strength of the external electric field (E), particle diameter (Dp), the zeta potential of the particle (ζp), and the location of the microparticle away from the channel wall (H) are systematically varied. The results are also compared to the data of pressure-driven flow having a parabolic flow profile at the inlet whose maximum magnitude is set to the particle's electrophoretic velocity magnitude. The validation studies reveal that the code developed for the particle motion in the present simulations agrees well with the experimental results. It is observed that protein adsorption can be controlled using electrokinetic phenomena. The plug-like flow profile in electrokinetics is beneficial for a microparticle at every spatial location in the microchannel, whereas it is not valid for the pressure-driven flow. The electric field strength and the zeta potential of the particle accelerate the protein adsorption. The wall shear stress and shear rate are good indicators to predict the adsorption process for electrokinetic flow.  相似文献   

18.
Electrokinetic phenomena play an important role for the transport in submicrometer-size channels since the electric double layers formed at the walls can occupy a substantial part of the channel volume. This presents a theoretical difficulty and specific problems are usually treated numerically or not comprehensively. In our work we present a theoretical model that allows one to obtain analytical expressions for the transport of fluid (electro-osmotic flow), ions (electric current), and dissolved charged molecules (analytes). The model is based on the weak double layer approximation and has a wide range of validity. An important feature of this theoretical approach is that it is applicable not only to symmetric but also to asymmetric 2:1 and 1:2 electrolytes which exhibit very interesting properties in nanoscale channels. The possibility of affecting the wall electrokinetic zeta potential by applying a transverse voltage bias is analyzed. This transverse bias is used in an attempt to control the transport in the channel and such devices are often called "fluidic field-effect transistors." Our model quantifies the effect of the voltage bias on the zeta potential of the channel wall and therefore can be used for prediction of transport and optimization of separations in such fluidic devices.  相似文献   

19.
Fu LM  Lin CH 《Electrophoresis》2004,25(21-22):3652-3659
An experimental and numerical investigation into the use of high-resolution injection techniques to separate DNA fragments within electrophoresis microchips is presented. The principal material transport mechanisms of electrokinetic migration, fluid flow, and diffusion are considered, and several variable-volume injection methods are discussed. A detailed analysis is provided of a double-L injection technique, which employs appropriate electrokinetic manipulations to reduce sample leakage within the microchip. The leakage effect in electroosmotic flow (EOF) is investigated using a sample composed of rhodamine B and Cy3 dye. Meanwhile, the effects of sample leakage in capillary electrophoresis (CE) separation are studied by considering the separation of 100-base pairs (bp) DNA ladders and HaeIII-digested PhiX-174 DNA samples. The present experimental and simulation results indicate that the unique injection system employed in the current microfluidic chip has the ability to replicate the functions of both the conventional cross-channel and the shift-channel injection systems. Furthermore, applying the double-L injection method to these two injection systems is shown to reduce sample leakage significantly. The proposed microfluidic chip and double-L injection technique developed in this study have an exciting potential for use in high-resolution, high-throughput biochemical analysis applications and in many other applications throughout the micrototal analysis systems field.  相似文献   

20.
Sweeping, an on‐line sample concentration technique in CE, is the picking and accumulation of analytes by the pseudostationary phase or complexing additive. In the presence of an electric field, the analytes concentrated at the additive front that initially penetrated the sample zone. Here, we describe the sweeping of cationic alprenolol enantiomers using sulfated β‐CD and organic solvent. The separation solution contained the anionic additive while ACN was in the sample solution. With fused silica capillaries, positive polarity, and solutions buffered at pH 3, the direction of the enantiomers' effective electrophoretic mobility was the same as the electrophoretic mobility (or electrophoretic mobility without additive). When the amount of ACN in the sample was increased (i.e. 60%), the interaction between the analytes and additive became negligible. This caused the sweeping boundary to shift from the electrophoretically moving β‐CD front to the zone between the sample and separation solution. The equation that described the narrowing of injected sample zone was derived. The performance of sweeping with 60% ACN in the sample was then studied under different operating conditions (e.g. type of injection, injection time, and CD concentration). The low interaction between enantiomers and additive gave only moderate increases in sensitivity (approximately tenfold), but was improved when field enhancement was used during electrokinetic injection. With a conductivity difference (separation/sample solution) of 70 and a short injection time of 30 s at 20 kV, peak improvements of >100‐fold was easily achieved.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号